Manuale d’uso / di manutenzione del prodotto TD-7ZDW del fabbricante Amtrol
Vai alla pagina of 16
BOILER MA TE TM TOP-DOWN INDIRECT -FIRED W A TER HEA TERS WITH TOP-MOUNTED COIL The heat transfer medium should be water . If any product other than water is used, it must be a non-toxic fluid suitable for human ingestion as determined by the FDA Y our AMTROL BOILER MA TE™ has been carefully assembled and factory tested.
-2- 1. GENERAL SAFETY INFORMA TION ...................................................................................... 3 2. PRE-INST ALLA TION CHECKLIST ........................................................................................ 4 Important Steps and Decisions Required Befor e Installation 3.
-3- IMPOR T ANT GENERAL SAFETY INFORMA TION - ADDITIONAL SPECIFIC SAFETY ALER TS APPEAR IN THE FOLLOWING INSTRUCTIONS EXPLOSION HAZARD: DO NOT INST ALL TO A HIGH PRESSURE STEAM BOILER (greater than 15 psig). AN EXPLOSION COULD OCCUR. EXPLOSION HAZARD.
-4- j THIS PRODUCT MUST BE INST ALLED AND MAINT AINED BY A LICENSED PROFESSIONAL. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND ST A TE CODES OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NA TIONAL PLUMBING CODE AND THE NA TIONAL ELECTRIC CODE.
-5- TD-7Z, TD-41Z, TD-7ZDW , TD-41ZDW COMPONENTS CHECKLIST The following is a checklist of components requir ed for proper installation of these BOILER MA TE™ models, both Priority and Non-Priority: A. Separate circulator • 1 each - circulator (4-8 gpm) • 1 each - positive shut-of f weighted check valve B.
-6- A. General Installation Requir ements 1. Do not "short circuit" the boiler Do not connect boiler supply and return lines to the same section or in the same flow circuit in a boiler , because the boiler water returning from the BOILER MA TE™ will "short circuit" and exit the boiler too cold for pr oper heat transfer .
-7- B. PIPING PIPING SHOULD BE ACCOMPLISHED WITH UNIONS. Step 1 - Locate the BOILER MA TE™ near boiler . Step 2 - Connect the cold water piping. a. Shut off the cold water supply at the main shut-of f valve. b. Drain existing domestic water system. Open 1 or more system faucets to pr event vacuum.
-8- Step 5 - Connect boiler supply pipe. Figure 1. a. Shut off the cold water supply valve to the boiler , and drain it using a hose attached to the drain valve at the boiler . b. When the boiler system piping is drained, cut the piping to accommodate the supply line tee.
-9- the service switch). c. Switch of f the branch cir cuit breaker . Step 2 - Remove electrical box cover . Step 3 - Remove existing wir e fr om boiler aquastat terminal C1 and connect to terminal #2 on DPDT relay . Step 4 - Install wire fr om DPDT relay terminal #1 to boiler aquastat terminal C1.
-10-.
- 11 - The BOILER MA TE™ is intended to pr ovide a tank service life of many years. Components, however , may be subject to failur es that requir e service. Failure to use the corr ect procedur es or parts in these circumstances may make the unit unsafe.
-12- RESIDENTIAL BOILER MA TE™ CLASSIC (TD-7Z and TD-41Z) ELECTROCUTION HAZARD. THE BOILER MA TE™ MUST BE ELECTRICALL Y GROUNDED. NOTES: 1. THE BOILER MA TE™ MUST BE ELECTRI- CALL Y GROUNDED AND INST ALLED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NA TIONAL ELECTRIC CODE.
- 13 - PROBLEM CAUSE SOLUTION 1. No hot water at faucet. 1. Boiler does not operate. 1. a. Press reset button on boiler . b. Check main cut-off switch. c. Check fuse. 2. Circulator does not operate. 2. a. Check power supply . b. Check shaft coupling. c.
-14- DA TE SERVICE PERFORMED COMMENTS CONTRACTOR 9. SERVICE RECORD.
AMTROL ® BOILERMA TE ™ CLASSIC AND TOP-DOWN™ LIMITED PRODUCT WARRANTY This W arranty cannot be transferred - it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below .
West W arwick, Rhode Island 02893 Part #: 9040-628 REV B (7/04) -16-.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Amtrol TD-7ZDW è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Amtrol TD-7ZDW - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Amtrol TD-7ZDW imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Amtrol TD-7ZDW ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Amtrol TD-7ZDW, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Amtrol TD-7ZDW.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Amtrol TD-7ZDW. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Amtrol TD-7ZDW insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.