Manuale d’uso / di manutenzione del prodotto IOC100P del fabbricante Invacare
Vai alla pagina of 32
Dealer: This manual MUST be given to the end user. User: Before using this product, read this manual and save for future ref erence. For more information regarding Invacare products, parts, and services, please visit www.
WARNING Pneumatic Oxygen Conserver 2 Part No 1160840 WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instruct ions and .
TABLE OF CONTENTS TABLE OF CONTENTS Part No 1160840 3 Pneumatic Oxygen Conserver REGISTER YOUR PRODUCT .............................. 4 SPECIAL NOTES ............................................... 5 Receiving Inspection ................... ..........
REGISTER YOUR PRO DUCT Pneumatic Oxygen Conserver 4 Part No 1160840 REGISTER YOUR PRODUCT The benefits of registering include: 1. Safeguarding your investment. 2. Ensuring long-term maintenance and servicing of your product. 3. Receiving updates wi th product information, maintenance tips and industry news.
SPECIAL NOTES Part No 1160840 5 Pneumatic Oxygen C onserver SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage.
SPECIAL NOTES Pneumatic Oxygen Conserver 6 Part No 1160840 Disposal Instructions This device and its packaging contain no hazardous materials. No special precautions need to be taken when disposing the device and/or it’ s packaging.
SPECIAL NOTES Part No 1160840 7 Pneumatic Oxygen C onserver DANGER DO NOT SMOKE while using this device. Keep all matches, lit cigarettes or oth.
INTRODUCTION Pneumatic Oxygen Conserver 8 Part No 1160840 INTRODUCTION The oxygen conserving regulator includes a combination of low ‐ pressure regulator and an oxygen conserver, designed for use with a cylinder as an ambulatory oxygen system.
SECTION 1—GENERAL GUIDELINES Part No 1160840 9 Pneumatic Oxygen C onserver SECTION 1—GENERAL GUIDELINES When using the oxygen conserving regulator, basic precautions .
SECTION 1—GENERAL GUIDELINES Pneumatic Oxygen Conserver 10 Part No 1160840 DO NOT attempt to repair product. DO NOT immerse product in any kind of liquid. Store product in a clean area when not in use.
SECTION 1—GENERAL GUIDELINES Part No 1160840 11 Pneumatic Oxygen Conserve r DO NOT allow cylinders to tip or fall. Secure gas cylinders so they cannot fall. Ensure cylinder is always in upright position.
SECTION 1—GENERAL GUIDELINES Pneumatic Oxygen Conserver 12 Part No 1160840 DO NOT place the unit under such items as blankets, bed coverings, chair .
SECTION 2—FEATURES Part No 1160840 13 Pneumatic Oxygen Conserve r SECTION 2—FEATURES DANGER This product is not intended as a life ‐ sustaining or life ‐ supporting device. CAUTION Missing or illegible labels MUST be replaced .
SECTION 2—FEATURES Pneumatic Oxygen Conserver 14 Part No 1160840 Oxygen Pressure Gauge: Enables the user to monitor the contents of the compressed oxygen cylinder and is protected by a rubber guard.
SECTION 2—FEATURES Part No 1160840 15 Pneumatic Oxygen Conserve r FIGURE 2.2 Connection view of the IOC100P with CGA870 Connection.
SECTION 3—INSTALLING THE CONSERVING REGULATOR Pneumatic Oxygen Conserver 16 Part No 1160840 SECTION 3—INSTALLING THE CONSERVING REGULATOR WARNING DO NOT allow oil from your.
SECTION 3—INSTALLING THE CONSERVING REGULATOR Part No 1160840 17 Pneumatic Oxygen Conserve r NOTE: For information on how to operate the cylinder, cons ult your equipment pr ovider. NOTE: For this procedure, refe r to FIGURE 3.
SECTION 4—OPERATING INSTRUCTIONS Pneumatic Oxygen Conserver 18 Part No 1160840 SECTION 4—OPERATING INSTRUCTIONS DANGER NEVER smoke in an area where oxygen is being administered.
SECTION 4—OPERATING INSTRUCTIONS Part No 1160840 19 Pneumatic Oxygen Conserve r 4. Listen for leaks. If a leak is present, close the cylinder valve, check the CGA870 seal washer, and reinstall.
SECTION 4—OPERATING INSTRUCTIONS Pneumatic Oxygen Conserver 20 Part No 1160840 WARNING NO OXYGEN is delivered in between settings. To obtain desired flow, the indicating pointer MUST align with a specific number on the dial.
SECTION 4—OPERATING INSTRUCTIONS Part No 1160840 21 Pneumatic Oxygen Conserve r 12. When finished using the system, close th e oxygen supply cylinder valve and continue breathing through the nasa l cannula until no further oxygen flow is detected.
SECTION 5—REMOVING THE CONSERVING REGULATOR Pneumatic Oxygen Conserver 22 Part No 1160840 SECTION 5—REMOVING THE CONSERVING REGULATOR DANGER NEVER attempt to remove the oxygen conserving regulator from an oxygen cylinder unless the cylinder valve is completely closed .
SECTION 6—TYPICAL PRODUCT PARAMETERS Part No 1160840 23 Pneumatic Oxygen Conserve r SECTION 6—TYPICAL PRODUCT PARAMETERS OXYGEN DELIVERY: SELECTOR SWITCH POSITION LITER FLOW EQUIVALEN CY 0O F F 11 22 33 44 55 66 CONTINUOUS FLOW EMERGENCY BYPASS SETTING: Factory Preset at 2 ± .
SECTION 6—TYPICAL PRODUCT PARAMETERS Pneumatic Oxygen Conserver 24 Part No 1160840 STORAGE/ TRANSPORTATION: Maximum -40°F (-40°C), 1% RH Maximum 145°F (63°C), 44% RH SHOCK VIBRATION: Not to exce.
SECTION 6—TYPICAL PRODUCT PARAMETERS Part No 1160840 25 Pneumatic Oxygen Conserve r Oxygen Cylinder Duration The total delivery of o xygen via the conserver is re.
SECTION 7—MAINTENANCE Pneumatic Oxygen Conserver 26 Part No 1160840 SECTION 7—MAINTENANCE CAUTION DO NOT use cleaning solutions. DO NOT immerse product in any kind of liquid. All repairs MUST be done by Invacare Corporation.
SECTION 8—TROUBLESHOOTING Part No 1160840 27 Pneumatic Oxygen Conserve r SECTION 8—TROUBLESHOOTING If oxygen conserving regulator fails to function, consult the T roubleshooting guide.
NOTES Pneumatic Oxygen Conserver 28 Part No 1160840 NOTES.
NOTES Pneumatic Oxygen Conserver 29 Part No 1160840 NOTES.
LIMITED WARRANTY Pneumatic Oxygen Conserver 30 Part No 1160840 LIMITED WARRANTY PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser/user of our products.
LIMITED WARRANTY Part No 1160840 31 Pneumatic Oxygen Conserve r LIMITATIONS AND EXCLUSIONS : THE FOREGOING WARRANTY SHALL NOT APPL Y TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED O.
Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio USA 44036-2125 800-333-6900 Technical Services 800-832-4707 Distributed by Invacare All rights reserved. Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unle ss otherwise noted.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Invacare IOC100P è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Invacare IOC100P - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Invacare IOC100P imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Invacare IOC100P ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Invacare IOC100P, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Invacare IOC100P.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Invacare IOC100P. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Invacare IOC100P insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.