User Manual EN This manual MUST be given to the user of the product. BEFORE using this product, read this manual and sa ve for future reference. Invacare ® TheraPure™ Side Entry Whirlp ool Tubs Mod.
CONTENTS Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 2 Part No. 116 7457 1 GENERAL 4 Symbols and Signal Words...................... .......................... ............................... ........................ ...................... ....
CONTENTS Part No. 1167457 3 Invacare ® TheraPure™ Side Entry Whirlpool Tubs 5 OPERATING INSTRUCTIONS 22 Overview ........................... ......................... ............................... .......................... ......................
1 GENERAL Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 4 Part No. 116 7457 1 General 1.1 Symbols and Signal Words Signal words are used in this manu al and apply to hazards or unsafe practices which co uld result in personal injury or property damage.
1 GENERAL Part No. 1167457 5 Invacare ® TheraPure™ Side Entry Whirlpool Tubs 1.2 Lim ited Warranty This warranty is extended onl y to the original purchaser/user of our products. This warranty gives you specific legal rights and you may also h ave other legal rights which vary from stat e to state.
2 SAFETY Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 6 Part No. 116 7457 2 Safety The Safety section contains important information for the safe operation and use of this product.
2 SAFETY Part No. 1167457 7 Invacare ® TheraPure™ Side Entry Whirlpool Tubs WARNING - PLUMBING Be certain all plumbing work is performed by a qualified plumber and is in compliance with local codes.
3 OVERVIEW Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 8 Part No. 116 7457 3 Overview 3.1 Features Whirlpool On/Off Button Fill Button (Push-in once to auto-fill, push-in and hold to add addit.
3 OVERVIEW Part No. 1167457 9 Invacare ® TheraPure™ Side Entry Whirlpool Tubs Whirlpool Jet Shower/Massage Wand Overflow Fill Spout Adjustment for angle of wand in cradle Flow Control Valve Shower .
3 OVERVIEW Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 10 Part No. 116 7457 3.2 Product Labeling Model 3652G Models 3602GXL Labels located inside the Cabinet Door Cabinet Door Label lo.
3 OVERVIEW Part No. 1167457 11 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 3.3 Typical Product Parameters 3602GXL 3652G Weight Tub (shipping weight) Tub (empty) Tub (filled without user) Floor.
3 OVERVIEW Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 12 Part No. 116 7457 3.4 Minimum Floor Space and Clearance Requirements Model 3602GXL Tub is shown with Model 1900 Traverse lift.
3 OVERVIEW Part No. 1167457 13 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs Model 3652G Tub is shown with Model 1900 Traverse lift. 12’ 6” to 24” 38.5” 12’ 8.5’ 36” MIN MINIMUM TUB CLEARANCE 76.5” to 94.5” 36” A l l ow f or a 38 .
3 OVERVIEW Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 14 Part No. 116 7457 3.5 Dimensions Model 3602GXL Connection Location Type C 9.5” (241 mm) from left side of tub, 5.5” (140 mm) up from floor 3/4” Cold water stub (with recommended shut off valve) D 16.
3 OVERVIEW Part No. 1167457 15 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs Model 3652G Connection Location Type C 4.625” (117 mm) from centerline, 5.
4 INSTALLATION Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 16 Part No. 116 7457 4 Installation 4.1 Preparing the Work Area 1. Determine location for t he tub installation. 2. Carefully remove the tub from the cart on and inspect for shipping damage.
4 INSTALLATION Part No. 1167457 17 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 4.2 Electrical and Plumbing Hook-up Locations on the Tub For installation details, refer to Refer to Electrical Insta llation on page 19 and Plumbing Installation on page 20.
4 INSTALLATION Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 18 Part No. 116 7457 4.3 Securing the Tub 1. Set the tub in place. 2. Ensure the plumbing and electrical hoo k-ups have been installed. 3. Mark the locations of the ancho r holes, using pre-drilled holes in l eg mounting pads as a template.
4 INSTALLATION Part No. 1167457 19 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 4.5 Electrical Installation Ensure a 15 AMP GFCI breaker is installed to protect the unit. Inse rt the plug into a pre-installe d GFCI protected hospital gra de receptacle.
4 INSTALLATION Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 20 Part No. 116 7457 4.6 Plum bing Installation 1. Refer to Electrical and Plumbing Hook-up Locations on the Tub on page 17 for the location of the hot water stub and cold water stub. 2.
4 INSTALLATION Part No. 1167457 21 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 4.7 Post Insta llation Checklist Before putting the tub into service, check the following: ❑ Water lines have been purged of any foreign matter. ❑ Both hot and cold water lines are properly connected to the tub.
5 OPERATING INSTRUCTIONS Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 22 Part No. 116 7457 5 Operating Instructions 5.1 Overview WARNINGS Read and understand ALL information in this manual BEFORE use. Clean and disinfect the tub after EACH use to avoid resident infection and contamination of the tub.
5 OPERATING INSTRUCTIONS Part No. 1167457 23 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs Perform these procedures in the following order: 1. Make sure that the t ub has been cleaned, disinfected and BEFORE use. Refer to Cleaning and Disinfecting on page 23.
5 OPERATING INSTRUCTIONS Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 24 Part No. 116 7457 1. Use the drain plug to close the drain. 2. Remove and disassemb le all jet assemblies . Lay all pieces in the botto m of the tub. • Rotate each jet ass embly counterclockwise and pull aw ay from the jet casing.
5 OPERATING INSTRUCTIONS Part No. 1167457 25 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 8. Replace the imp eller and impeller cap on each jet assembly by rotating them counterclockwise. 9. Assemble each jet assembly to the jet casings. • Position th e Sanijet® logo and RED indicator at the 11 o’clock position.
5 OPERATING INSTRUCTIONS Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 26 Part No. 116 7457 5.3 O pening/Closing the Tub Door Opening the Tub Door 1. Place one hand on top of the door handle. 2. Use the other hand to pull the safety pin o ut and release the door handle.
5 OPERATING INSTRUCTIONS Part No. 1167457 27 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 5.4 Sh oulder and Waist Straps Installation On each end of the straps, insert the lead into the round portio n of the slot in the attachment point, slide the lead up and tu rn it.
5 OPERATING INSTRUCTIONS Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 28 Part No. 116 7457 5.5 Water Temperature Setting Flow Water Thermometer - measures the temperature of wate r coming from the tub fi ll spout or shower/massage wand. Water Temperature Control Valve - sets and maintains constant temperat ure for all incoming water.
5 OPERATING INSTRUCTIONS Part No. 1167457 29 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 5.6 Fi lling the Tub 1. Close the drain with the bl ue stopper. 2. Push the tub fill button to start the auto tub fill. 3. Use the water temperature control valve to adjust the water te mp erature while watching the flow water thermometer.
5 OPERATING INSTRUCTIONS Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 30 Part No. 116 7457 5.8 Using th e Whirlpool Function 1. If the water level do es not cover the whirlpool jets, push the tub fill button to auto-fill the tub.
6 INSPECTION AND TROUBLESHOOTING Part No. 1167457 31 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 6 Inspection and Troubleshooting If any part of the system is not functioning properly, DO NOT use the system. For parts and tec hnic al service information pleas e contact ICCI Technical Service at (800) 668-2337, Extension 2.
6 INSPECTION AND TROUBLESHOOTING Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 32 Part No. 116 7457 6.2 Troubleshooting If problems are not remedied , contact technical support at 1-800-668-2337, Extension 2.
6 INSPECTION AND TROUBLESHOOTING Part No. 1167457 33 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs 6.3 Maintenance Record DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES.
6 INSPECTION AND TROUBLESHOOTING Invacare ® TheraPure™ Side Entry Whirlpool Tu bs 34 Part No. 116 7457 DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES.
6 INSPECTION AND TROUBLESHOOTING Part No. 1167457 35 Invacare ® TheraPure™ Side Entry Whirlp ool Tubs DATE MAINTENANCE PERSON TYPE OF MAINTENANCE PERFORMED NOTES.
Invacare Corporation www.invacare-cc.com USA One Invacare Way Elyria, Ohio USA 44036-2125 Canada 994 Hargrieve Road London, Ontario Canada N6E IP5 Customer Service 1-800-668-2337 Technical Support 1-800-668-2337, Extension 2 Manufacturing Location 899 Cleveland Street Elyria, Ohio 44036 © 2011 Invacare Corporation.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Invacare 3602GXL è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Invacare 3602GXL - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Invacare 3602GXL imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Invacare 3602GXL ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Invacare 3602GXL, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Invacare 3602GXL.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Invacare 3602GXL. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Invacare 3602GXL insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.