Manuale d’uso / di manutenzione del prodotto SR1680MV del fabbricante Intel
Vai alla pagina of 196
In tel ® Serv er S ystem SR1680M V Service Guide A Guide for T e chnically Qu alified Assemblers of In tel® Identified Subassemb lies/Products Intel Ord er Number E748 35-004.
ii Intel ® Server System SR1680MV Service Guide Disclaimer Information in this document is provided in connection wit h Intel® products. No license, e xpress or implied, by estoppel or otherwise, to any intellectual proper ty rights is granted by this document .
Intel ® Server System SR1680MV Service Guide iii.
iv Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide v Pr e fac e About this Manual Thank you for purchasing and using the Intel ® Server System SR1680MV . This manual is written for system technici ans who are responsible for troubleshooting, upgrading, and repairing this server system.
vi Intel ® Server System SR1680MV Service Guide Pr oduct C onten ts, Or der Op tions, and Accessories Yo u r I n t e l ® Server System SR1680MV ship s with the following items: • One 1U chassis • T wo Server Boards • T wo Riser Cards • T wo 2.
Intel ® Server System SR1680MV Service Guide vii Unless otherwise indicated in the following table, once on this webpage, type the document or software name in the search field at the left side of the screen and select the option to search “This Product.
viii Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide ix Sa f ety In f orma tion Importan t Saf e ty Instructions Read all caution and safety statements in th is docu ment before performing any of the instructions. See also Intel Server Boards an d Server Chassis Safety Information on the Intel ® Server Resour ce CD and/or at http://support.
x Intel ® Server System SR1680MV Service Guide 䞡㽕ᅝܼᣛᇐ ᠻ㸠ӏԩᣛҸПࠡˈ䇋䯙 䇏ᴀ᭛ḷЁⱘ᠔᳝⊼ᛣџ乍ঞᅝܼໄᯢDŽ http://support.
Intel ® Server System SR1680MV Service Guide xi Wa r n i n g s Heed safety instructions: Before working with yo ur server product, wheth er you are using this gui de or any other resource as a re ference, pay close attention to the safety instructions.
xii Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide xiii T able o f Con ten ts Preface .............. ................. ................................ .............. ............... .............. ............. .. v About this Manual .....................
xiv Intel ® Server System SR1680MV Service Guide Removing a DIMM ............................................................................................... ....... 21 Installing a DIMM .. .........................................................
Intel ® Server System SR1680MV Service Guide xv Chapter 5: BIOS Setup a nd Configuration ........ .......................................... ........... 59 BIOS Setup Utility ......................................................................... .
xvi Intel ® Server System SR1680MV Service Guide BIOS POST Beep Codes ..................................................... ..................................... 114 Appendix C: Installation/Assembly Safety Instructions ...... ................. .....
Intel ® Server System SR1680MV Service Guide xvii Manipulación del equipo ......................................................................... ................... 145 Advertencias de alimentación y eléctricas .................................
xviii Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide xix List o f Figur es Figure 1. Intel ® Server System SR1680MV with 2.5-inch Pluggable HDDs.............................. 1 Figure 2. Layout of Server Chassis with 2.5-inch Pluggable HDDs ................
xx Intel ® Server System SR1680MV Service Guide Figure 43. Lifting the PCI Cage from the I/O Board Module ................................................... 37 Figure 44. Removing the Expansion Ca rd .................................................
Intel ® Server System SR1680MV Service Guide xxi List o f T ables Table 1. Intel ® Server System SR1680MV Feature Summary .................................................. 2 Table 2. LED Information .................................................
xxii Intel ® Server System SR1680MV Service Guide Table 43. Location and Adapt Depth for Racks .................................................... ................ 100 Table 44. Resetting the System ..................................................
Intel ® Server System SR1680MV Service Guide 1 1 Serv er S ystem F eatur es This chapter briefly describes th e main featu res of the Intel ® Server System SR1680MV.
2 Intel ® Server System SR1680MV Service Guide Ta b l e 1 summarizes the features of the server chassis. Ta b l e 1 . I n t e l ® Server S ystem SR1 680MV Featur e Summary Featu re Descrip tion Dimensions • 43.2 mm hei ght • 448 mm width • 714.
Intel ® Server System SR1680MV Service Guide 3 S ystem Ov erview Serv er Chassis Lay out Figur e 2. Lay out of S erver Chassis with 2.5-in ch Pluggable HDDs Fr ont Vie w Components The front view of this 1U server allows eas y access to 2.5-inch pluggable SA T A HDDs.
4 Intel ® Server System SR1680MV Service Guide The following introduces the front view of the server with 2.5-inch pluggable HDDs: Figure 3. Fr ont View o f Server with 2.5-inch Pluggable HDDs Back View Componen ts The server back view includes connectors, butto ns, and system LEDs of both internal and external devices.
Intel ® Server System SR1680MV Service Guide 5 Butt ons and Sys tem L EDs Fr ont P anel Butt ons and LEDs This server is equipped with system LED indicators, buttons, and two front panel USB ports located on the front panel. The front pa nel status LEDs allow co nstant monitoring of basic system functions while the server is op erating.
6 Intel ® Server System SR1680MV Service Guide The back view LEDs and buttons informatio n display details regarding the LEDs and buttons of the two I/ O boards and AC power LED. Re a r Pa n e l B u t t o n a n d LE D s Figure 6. Back View LEDs and Buttons of T wo I/O Boards The following table provides detailed LED information.
Intel ® Server System SR1680MV Service Guide 7 System Health LED Red Blinking: System has non-cr itical errors. After error condition is cleared, LED is off. On: System has critical errors. LED needs to remain active until the ne xt power-off and power-on provided that the error condition is cleared .
8 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 9 2 Har dw ar e Installations and Upgr ades Be f or e Y ou Begin Before working with your server product, pay close attention to “Safety Information” . This document provides instru ctions for adding and replacing system components.
10 Intel ® Server System SR1680MV Service Guide Sys tem R ef er ences All references to left, right, front, top, and bo ttom assume the reader is facing the front of the chassis as it would be positioned for normal operation. Po w er Off Before any replacement, you must power off the server completely .
Intel ® Server System SR1680MV Service Guide 11 Unplugging the Po wer C or d Y ou must first un plug the power cord from the AC outle t and then from the server .
12 Intel ® Server System SR1680MV Service Guide Figure 9. R emoving the Mid-T op Cov er Cen tral Pr ocessing Unit (CPU) Each installed server node pr ovides two surface mount LGA 1366 CPU s ockets designed for the Intel ® Xeon ® Proce ssor 5500 series.
Intel ® Server System SR1680MV Service Guide 13 Y ou can install single or dual processors on the motherboard according to your own needs. 1. If a SINGLE processor is intended, it is recommended that yo u install the processor on the processor 1 socket.
14 Intel ® Server System SR1680MV Service Guide Figure 12. Lifting the Pr ocessor Out of the Socke t 4. Place the PnP cap onto the load plate. Figure 13.
Intel ® Server System SR1680MV Service Guide 15 5. Close the load plate. 6. Lock the load lever . Figure 14. Closing the Load Pla te Installing the Pr ocessor Reverse the steps in “Removing the Processor” to install the processor .
16 Intel ® Server System SR1680MV Service Guide Figure 15. P ointing the Golden Corner T oward the Sock et Note: When the pr ocessor is in place, pr ess it firmly on the socket while you push down the socket lever to secur e the pr ocessor . The lever clicks on the socket indicating it is locked.
Intel ® Server System SR1680MV Service Guide 17 Figure 16. R emoving the Heatsink Installing the Hea tsink Reverse the steps in “Removing the Heatsink” to install the heatsink. Make sure you put the heatsink in the right di rection—you sh ould see the heat sink information wh en you finish the heatsink installation.
18 Intel ® Server System SR1680MV Service Guide Figure 17. L ocation o f Sys tem Memories There are 18 DIMMs on the motherboard to support processor 1 and processor 2. The DIMM sequence of 18 DIMM sockets is respectively shown in Figure 18. Figure 18.
Intel ® Server System SR1680MV Service Guide 19 Sys tem Memory Channel P opula tion R equir emen ts f or Memory RAS Modes The rules on channel population and channel ma tching vary by the RAS mode used. There are three different memory RAS modes: I ndependent Channel Mo de, Mirrored Ch annel Mode, and Lockstep Ch annel Mode.
20 Intel ® Server System SR1680MV Service Guide Note: The empty DIMM socket is marked as “-” a nd installed DIMM socket is marked as “V”. It is r ecommended to insert DIMM equally for each CPU so as to give maximizes system performance. It is highly r ecommended that all DIMMs w ith same part number be used within one motherboar d.
Intel ® Server System SR1680MV Service Guide 21 Before you remove or install any DI MMs, complete the following steps: 1. Make sure the server is not turned on or connected to the AC power . T o power off the server , see “Power Of f” . 2. Remove the chassis cover .
22 Intel ® Server System SR1680MV Service Guide Figure 20. Pr essing the Re taining Clips Outward 2. Align the notch on the DIMM to the br eak on the socket. Carefully insert the DIMM into the socket until the retaining clips snap back in place. Figur e 21.
Intel ® Server System SR1680MV Service Guide 23 Note: DIMMs fit in only one dir ection. DO NOT for ce a DIMM into the socket to avoid damaging the DIMM . Serv er Boar d Cage Module This section explains how to replace the server board cage module from the chassis.
24 Intel ® Server System SR1680MV Service Guide 3. Pull the cage tray lever along the direct ion of the arrow to remove the module. Figure 24. Pull the L ocking Lev er to R emov e the Server Boar d C.
Intel ® Server System SR1680MV Service Guide 25 L e ft and Right I/O Boar d Cage Modules The left and right I/O board cage modules share the same steps du ring the removal and installation procedures. For your reference, this section takes the st eps of removing and installing the left I/O board cage module as an example.
26 Intel ® Server System SR1680MV Service Guide R emoving the L e ft I/O Boar d Cage Module 1. Slide the locking latch alon g the dir ection of the arrow . 2. The cage tray lever springs open by itself. Figure 27. Slide the L ockin g Lat ch 3. Pull the cage tray lever along the direct ion of the arrow to remove the module.
Intel ® Server System SR1680MV Service Guide 27 P ow er Supply Module This section introduces the re placement procedure for the power supply mo dule.
28 Intel ® Server System SR1680MV Service Guide Figure 30. R emoving the P ow er Supply Module Installing the P o wer Supply Module Reverse the “Removing the Power Supply Module” steps to install the power supply module. P ow er Distribution Boar d This section introduces the replacement proc edures of the power distribution board.
Intel ® Server System SR1680MV Service Guide 29 2. Remove the mid-top co ver . T o remove the cove r , see “Mid-T op Cover” . 3. Disconnect all necessar y cable connections. Remo ving the P o wer Dis tribution Boar d 1. Lift the power distribution boa rd from the chassis.
30 Intel ® Server System SR1680MV Service Guide Pluggable SA T A Driv e 2.5-inch Pluggable SA T A HDD The sever supports up to four 2.5-inch pl uggable SA T A HDDs, two on each server board module. Four HDDs share the same remova l and installation procedure.
Intel ® Server System SR1680MV Service Guide 31 Figure 34. R elease the L ocking L ev er 4. Pull the HDD carrier locking lever ou t along the direction of the arrow . Figure 35. Pull the Locking L ever t o Remo ve the HDD Carrier 5. Loosen and remove the four securing sc rews.
32 Intel ® Server System SR1680MV Service Guide Figur e 36. Release Sc rews and Lift the HDD Up Installing a 2.5-inch Pluggable S A T A HDD Reverse the “Removing a 2.5-inch Pluggable SA T A HDD” steps to install the 2.5-inch pluggable SA T A HDD.
Intel ® Server System SR1680MV Service Guide 33 Note: Befor e you r emove or install the power supply , complete the following steps: 1. Make sure the server is not turned on or connected to the AC power . T o power off the server , see “Power Of f” .
34 Intel ® Server System SR1680MV Service Guide Figur e 39. Sys tem Fans Lo cation Note: B e f o re y o u re m o v e o r i n s t all the power supply , comp lete the following steps: 1. Make sure the server is not turned on or connected to the AC power .
Intel ® Server System SR1680MV Service Guide 35 Inst al lin g a Syste m Fa n Reverse the “Removing a System Fan” steps to install the system fan. Air Duct Note: Befor e you r emove or install the ai r duct, complete th e following steps: 1. Make sure the server is not turned on or connected to the AC power .
36 Intel ® Server System SR1680MV Service Guide Installing Air Ducts Reverse the “Removing the IOB Air Duct” steps to install the air duct. PCI-E Cage The left and right I/O board cage modules e ach include one PCI-E cage. T wo PCI-E cages on the server share the same removal and insta l lation proced ures.
Intel ® Server System SR1680MV Service Guide 37 Figure 43. Lifting the PCI Ca ge from the I/O Boar d Module 2. Loosen and remove the securing screw . 3. Pull out the expansion ca rd with the slot cover from the PCI-E cage. Figure 44. R emoving the Expansion Card 4.
38 Intel ® Server System SR1680MV Service Guide Figure 45. Securing the Slot Co ver 6. Loosen and remove the two securing screws as shown in Figure 46 .
Intel ® Server System SR1680MV Service Guide 39 Figur e 47. 10 GB IO Car d L ocatio n Figure 48 shows th e location of the InfiniBand card. Figure 48. In finiBand Card L ocation Note: Befor e you r emove or install the 10 GB IO car d, complete the following steps: 1.
40 Intel ® Server System SR1680MV Service Guide Figure 49. Lifting the Module Upwar d fr om the IO Boar d 2. Remove the I/O Expansion mod ule out of the IO board modu le.
Intel ® Server System SR1680MV Service Guide 41 Installing the IO Expansion Module Reverse the steps in the “Removing the IO Expansion Modu le” to install the IO Expansion module.
42 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 43 3 Cable Connections Connect ors and Pin 1 Loca tions Figure 51 shows the dif ferent locations of the connectors and their pin 1 locations, which can help you co nnect the cables.
44 Intel ® Server System SR1680MV Service Guide Figure 52. L ocations of Connectors and Pin 1 on I/O Boar d Cable Connections Y ou can get a clear picture on how to conn ect the cables from the following figures. Before connecting the cables, yo u must make su re there are no existing bent pin s because they will affect signal transmission.
Intel ® Server System SR1680MV Service Guide 45 Figure 53. Connecting the Sys tem Fan Cables.
46 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 47 4 Connectors, Jumpers, and L EDs Connect or and Componen t L oca tions o f Serv er Boar d Figure 54. C onnectors and Component Loca tions of Serv er Board 1. System Batter y (BH1) 2. ICH Functions Jumper (J30) 3.
48 Intel ® Server System SR1680MV Service Guide 17. Front UID LED 18. Front UID Button 19. P ower Button 20. System Health LED 21. Po wer LED 22. Front USB P or ts 23.
Intel ® Server System SR1680MV Service Guide 49 Connect or and Componen t L oca tions o f IO Boar d Figure 55. C onnectors and Componen t Loca tions of IO Boar ds Descrip tion Loca tion Descrip tion L ocation Left R ig ht Left Ri ght 1. PCI-E x8 Slots J5 J5 2.
50 Intel ® Server System SR1680MV Service Guide Connect or and Componen t L oca tions o f NIC Boar d Figure 56. C onnectors and Component L ocations o f NIC Board 1.
Intel ® Server System SR1680MV Service Guide 51 Connect ors and Componen ts o f Fr on t P anel Figure 57. C onnectors and Component Loca tions of Fr ont P anel 1. F ront V GA P or t 2 . F ront Ser ial P or t 3. NIC LED 4. F ront USB P ort 5. System Health LED 6.
52 Intel ® Server System SR1680MV Service Guide 10 GB IO Car d (Op tional Daughter Car d) Figure 58. Connect ors and Components of 10 GB IO Card 1. PCI-E 2 Connector 2.
Intel ® Server System SR1680MV Service Guide 53 In finiBand Car d (Op tional Daugh ter Car d) Figure 59. Connectors and Componen ts of In finiBand Card 1.
54 Intel ® Server System SR1680MV Service Guide Connect or and Componen t L oca tions o f HDD Backplane Figure 60. C onnectors and Components of 2.5-inch Pluggable HDD Backplane 1. HDD 0 F ail LED (CR4) 2. HDD 1 F ail LED (CR2) 3. HDD 1 Active LED (CR1) 4.
Intel ® Server System SR1680MV Service Guide 55 Connect ors and Componen t L oca tions o f PDB Figure 61. C onnectors and Component Loca tions of PDB The server board involves two system mainte nance jumpers. One is MISC jumper , and the other is an ICH functions jumper .
56 Intel ® Server System SR1680MV Service Guide Figure 62. L ocation o f MISC Jumper Jumper Functi on A Reser ved B Clear BMC P ass word C Reser ved D Reser ved E Reser ved F Reser ved G Reser ved H .
Intel ® Server System SR1680MV Service Guide 57 Figure 63. L ocation o f ICH Function Jumper Ju mper Function A Clear CMOS B Clear P assword C Recov ery RWH D BIOS Prot ect E R TC Reset.
58 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 59 5 BIOS Se tup and Con figur ation This section describes the BIOS Setup Utili ty options. Y ou can run the BIOS setup with or without an operating system present. Onboard devices are configured with the BIOS Setup utility that is embedded in flash ROM.
60 Intel ® Server System SR1680MV Service Guide Entering the BIOS Se tup Utility During the BIOS POST operation, the user is prompted to use the Del function key to enter Setup as follows: Press <F2> to run <Setup>. Press <F1 1> to enter BBS POPUP .
Intel ® Server System SR1680MV Service Guide 61 ESC Exit The ESC k ey p rovides a me chanism f or bac king out of an y field. This ke y will u ndo the pressing of the Enter key . When the ESC ke y is pressed while e diting any field or selecting features of a menu, the parent menu is re-entered.
62 Intel ® Server System SR1680MV Service Guide BIOS Se tup Utility Menu The Setup Utility menu bar di splays the five pri mary me nu selections. For detailed information and screenshots of these Setup Utility menus and their related submenus, refer to the following sections.
Intel ® Server System SR1680MV Service Guide 63 Main Menu T able 7. Main Menu of BIOS Se tup Utility BIOS Se tup Utility Main Advanced Boot Security Exit System Overview AMIBIOS V ersion :08.00.15 Build Date :02/16/09 ID :MARBLE V ALLEY005 Processor Intel(R) Xeon(R) CPU E5540 @ 2.
64 Intel ® Server System SR1680MV Service Guide Adv anced Menu T able 9. Adv anced Menu of BIOS Se tup Utility BIOS Setup Utility Main Advanc ed Boot Secur ity Exit Advanced Settings W ARNING: Setting wrong values in belo w sections may cause system to malfunction.
Intel ® Server System SR1680MV Service Guide 65 T able 10. CPU Configur ation Submenu BIOS Se tup Utility Main Advanc ed Boot Security Exit Configure advanced CPU settings Module V ersion:3 F .1 3 Manuf acturer: :Intel Intel(R) Xeon(R) CPU :E5540 @ 2.
66 Intel ® Server System SR1680MV Service Guide V02.61 © Copyright 198 5-2006, Ameri can Megatrends, Inc. T able 10. CPU Conf igura tion Submenu BIOS Setup Utility Main Advanc ed Boot Secur ity Exit Configure advanced CPU settings T able 11.
Intel ® Server System SR1680MV Service Guide 67 QPI Links Speed Slow-Mode Full-Speed* T o transition the QPI links to full-speed or leav e them in Slo w-mode . QPI F requency Auto * 4.800GT 5.866GT 6.400GT T ransition the links to the specifie d speed when transitioning the links to full-speed.
68 Intel ® Server System SR1680MV Service Guide SA T A Configur ation Submenu T able 12. SA T A Configur a tion Submenu1 BIOS Se tup Utility Main Advanc ed Boot Se cur ity Exi t SA T A Configuration .
Intel ® Server System SR1680MV Service Guide 69 T able 13. SA T A Configur a tion Submenu2 BIOS Setup Util ity Main Advanced Boot Security Exit SA T A Configuration [Enhanced] Configure SA T A AS •.
70 Intel ® Server System SR1680MV Service Guide T able 14. SA T A Configur a tion Submenu3 BIOS Se tup Utility Main Advanc ed Boot Security Exit SA T A Configuration [Enhanced] Configure SA T A AS .
Intel ® Server System SR1680MV Service Guide 71 T able 15. SA T A Configur a tion Submenu4 BIOS Setup Utility Main Advanc ed Boot Secur ity Exit SA T A Configuration [Enhanced] Configure SA T A AS .
72 Intel ® Server System SR1680MV Service Guide T able 16. SA T A Configur ation Submenu Fields Menu Fiel ds Settings Descri ption SA T A Conf ig u rati on SA T A Configuration Disabled Compatible* E.
Intel ® Server System SR1680MV Service Guide 73 Super IO Chipse t Submenu T able 17. Super IO Chipset Submenu BIOS Setup Utility Main Advanced Boot Security Exit Configure PILO T Super IO Chipset Ser.
74 Intel ® Server System SR1680MV Service Guide T able 18. SA T A Configura tion Submenu Fields Menu Fields Settings Description Adv anced/Super IO Con figura tion Serial P or t Address Disab led 3F8/IRQ4 2F8/IRQ3 3F8/IRQ4 2F8/IRQ3 Allows BIOS to select Serial P or t1 Base Address.
Intel ® Server System SR1680MV Service Guide 75 USB Con figur ation Submen u T able 19. USB Configur a tion Submenu BIOS Setup Util ity Main Advanc ed Boo t Secur ity Exit USB Configuration Module V ersion - 2.24.3-13.4 USB De vices Enabled 2 K eyb oards, 3 Mice , 1 Hub , 2 Drives Legacy USB Suppor t [Enabled] USB 2.
76 Intel ® Server System SR1680MV Service Guide USB 2.0 Controller mode FullSpeed HiSpeed* Configures the USB 2.0 contro ller in HiSpeed (480 Mbps) or FullSpeed (12Mbps) BIOS EHCI Hand-Off Disab led Enab led* This is a workaround f or operating systems witho ut EHCI hand-off suppor t.
Intel ® Server System SR1680MV Service Guide 77 USB Mass S t or age De vice Con figura tion Submenu T able 21. USB Mass S tor age Devic e Configur a tion Submenu BIOS Se tup Utility Main Advanc ed Bo.
78 Intel ® Server System SR1680MV Service Guide T able 22. USB Mass S tor age Device Con figura tion Submenu Fields Menu Fiel ds Settings Description Adv anced/USB Configur at ion USB Mass Storage Reset Delay 10 Sec 20 Sec* 30 Sec 40 Sec Number of seconds POST waits f or the USB mass storage de vice after star t unit command.
Intel ® Server System SR1680MV Service Guide 79 PCI Expr ess* Con figur a tion Submenu T able 23. PCI Express* C onfigur ation Submenu BIOS Setup Util ity Main Advanc ed Boo t Secur ity Exit PCI Express Configuration Active State P o wer-Management [Disab led] Configure PCI Express* suppor t.
80 Intel ® Server System SR1680MV Service Guide IPMI Con figur a tion Submenu T able 25. IPMI Configur ation Submenu BIOS Se tup Utility Main Advanc ed Boo t Security Exit IPMI 2.
Intel ® Server System SR1680MV Service Guide 81 T able 26. IPMI Configura tion Submenu Fields Menu Fields Settings Descrip tion Adv anced/USB Con figur ation Disab le PEF No* Ye s * Y es or No to disable PEF in BMC after e xiting SETUP . It only affects once and then will be changed to [No] when [Y es] is selected.
82 Intel ® Server System SR1680MV Service Guide View BMC Sys tem Ev ent L og Submenu T able 27. View BMC System Even t Log Submenu BIOS Se tup Utility Main Advanc ed Boot Security Exit T otal Number .
Intel ® Server System SR1680MV Service Guide 83 Remo te Access Con figur a tion Submenu T able 28. Remote Access Con figura tion Subme nu BIOS Setup Utility Main Advanc ed Boot Secur ity Exit Remote Access [Enabled] Con figure Remote Access.
84 Intel ® Server System SR1680MV Service Guide Boo t Menu T able 30. Boot Menu of BIOS Se tup Utility BIOS Se tup Utility Main Advanced Boo t Security Exit Boot Settings • Boot Settings Configuration • Boot Device Priority • Remov able De vices • CD/D VD Dr ives Configure Settings du ring System Boot.
Intel ® Server System SR1680MV Service Guide 85 Boo t Se tting Con figur a tion Submenu T able 31. Boot Se tting Con figur ation Submenu o f BIOS Setup Utility BIOS Setup Util ity Main Advanced Boo t.
86 Intel ® Server System SR1680MV Service Guide AddOn ROM Displa y Mode Fo r c e B I O S * K eep Current Set displa y mode for Option ROM. Bootup Num Lock Off On* Select P ow er-on state for Numlock. Interrupt 19 Capture Disabled* Enabled Enabled: Allo ws option ROMs to trap interrupt 19.
Intel ® Server System SR1680MV Service Guide 87 Boo t Device Priority Submenu T able 33. Boo t Device Priority Su bmenu BIOS Se tup Utility Main Advanced Boot Security Exit Boot De vice Pr iority 1st Boot De vice [Network:IBA GE Slo] 2nd Boot De vice [Network:IBA GE Slo] Specifies the boot seque nce from the av ailable de vices.
88 Intel ® Server System SR1680MV Service Guide R emov able Driv es Submenu T able 34. Remo vable Driv es Submenu BIOS Se tup Utility Main Advanced Boot Security Exit Remov able Drives 1st Drive [USB:AMI Vir tual F1] Spec ifies the boot sequence from the av ailable de vices.
Intel ® Server System SR1680MV Service Guide 89 CD/D VD Drives Submenu T able 35. CD/DVD Driv es Submenu BIOS Setup Utility Main Advanced Boot Security Exit CD/D VD D rives 1st Drive [USB:AMI Vir tual CD] Specifies the boot sequence from the av ailable de vices.
90 Intel ® Server System SR1680MV Service Guide Security Menu T able 36. Security Menu of BIOS Se tup Utility BIOS Se tup Utility Main Advanced Boot Security Exit Security Settings Super visor P assw.
Intel ® Server System SR1680MV Service Guide 91 T able 37. Security Menu Fields Menu Fields Se ttings Descrip tion Advanced/Boo t Settings Configur ation P ass word Ch eck Setup* Alwa ys Setup: Check pass word while inv oking setup . Alwa ys: Check pass word while inv oking setup as well as on each boot.
92 Intel ® Server System SR1680MV Service Guide T rusted Computing Submenu T able 38. T rusted Computing Submenu BIOS Se tup Utility Main Advanced Boot Security Exit T ruste d Computing TCG/TPM Suppor t [N o] Enable/Disable TPM TCG (TPM 1.1/ 1.2) suppor t in BIOS.
Intel ® Server System SR1680MV Service Guide 93 T able 39. T rusted Computing Submenu Fields Menu Fields Se ttings Des cription Advanced/Boo t Settings Configur ation TCG/TPM SUPPOR T No* Ye s Enab le/Disab le TPM TCG (TPM 1 .
94 Intel ® Server System SR1680MV Service Guide Exit Menu T able 40. Exit Menu of BIOS Se tup Utility BIOS Se tup Utility Main Advanced Boot Security Exit Adva nced Chipset Settings Sav e Changes and Exit Discard Changes and Exit Load Optimal Defaults Load F ailsafe Def aults Exit system setup after sa ving the changes.
Intel ® Server System SR1680MV Service Guide 95 BIOS Upda tes BIOS Requir emen ts ROM F l a s h Upda ting under DOS promp t 1. Copy AFUDOS.EXE, FBB.BA T and RomFileName.rom (ROM image) to bootable storage. 2. Plug the bootab le storage (ex: USB disk) and boot to DOS promp t (no HIMEM).
96 Intel ® Server System SR1680MV Service Guide 4. Unplug US B Disk on Key (or Floppy/CD-ROM) & T urn of f the Recovery Jumper . 5. Restart system & load BIOS default.
Intel ® Server System SR1680MV Service Guide 97 6 Embedded S A T A RAID This section provides an overview of the SA T A Software RAID options embe dded on the server board.
98 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 99 7 Installing the Rackmoun t Rail Kits This section contains the detail instructions of installing rail kit to racks for this server . Reverse the instillation steps to remove the rail. The front overview and back ov erview of rail is shown below: Figure 64.
100 Intel ® Server System SR1680MV Service Guide Figur e 65. Loca tion Of Spring Scr ew Holes T able 43. Loca tion and Adap t Dep th for Racks Pr ocedur e t o ins tall the r ail kit Note: Please follow the steps below befor e you install the rail: 1.
Intel ® Server System SR1680MV Service Guide 101 Fi g u re 6 6 . S ec u re sc re w in to th e ra il h o le 3. Position left and right rails at th e desired ‘U’ position in the racks. 4. Secure rails to the front and back of th e racks using tighten screws1 and align pin (Recommended Driver Force 7 lb-in).
102 Intel ® Server System SR1680MV Service Guide 6. Push the server to the end of rack s to let the server snap the springs. Figur e 69. Push The Serv er T o The End Of Racks 7. T ighten the thumbscrews to secure the ears of the server to the racks. Figure 70.
Intel ® Server System SR1680MV Service Guide 103 Appendix A: In tel ® Serv er Issue R eport Fo r m Issue Report Form (Rev 3.6) Note: Filling out this form complete ly is required for any escalation.
104 Intel ® Server System SR1680MV Service Guide Has the latest BMC/mBMC been tried? (Y es/No): Has the latest IMM BMC been tried? (Y es/No): Has the latest RMM Firmware been tried? (Y es/N o): Has t.
Intel ® Server System SR1680MV Service Guide 105 Add-in adapters (Example: NICs , Management Ad apters, Serial Expansion Cards, PCI-Express* Adapters, RAID Contr ollers, SCSI Contr ollers, etc.): Third party hardwar e (Exampl e: KVM, Chassis, etc.): S torage Devices (Example: SCSI, SA T A, SAS, USB, T ape, etc.
106 Intel ® Server System SR1680MV Service Guide RAID controller part number (PBA number): RAID controller firmware version: Has the latest RAID firmware been tried? (Y es/No): RAID driver version: H.
Intel ® Server System SR1680MV Service Guide 107 S teps to replicate the issue: =================== ============== ================== ============ Issue impact statements: Do you have any potential Intel system, or component pur chases that this issue is holding up? If yes, please pr ovide a brief description below .
108 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 109 Appendix B: T r oubleshoo ting This chapter helps you identify and solve problems that mi ght occur while you are using the system. For any issue, first ensure you are using the latest firmware and files.
110 Intel ® Server System SR1680MV Service Guide • Are all cables correctly connected a nd secured? • Are the processors fully seated in their sockets • Are all standoffs in the proper location.
Intel ® Server System SR1680MV Service Guide 111 4. If the operating system norm ally loads from the hard disk drive, make sure there is no other plu ggable boot de vice. 5. T urn on the system. If the power LED does not light, see “Power Light Do es Not Light” .
112 Intel ® Server System SR1680MV Service Guide • Make sure the memory DIM Ms have been populated according to the sys tem requirements. • Remove the memory DIMMs and re-seat them. • Make sure the processor(s) comply with the system requirements.
Intel ® Server System SR1680MV Service Guide 113 Sys tem Cooling Fans Do No t R o ta te Pr operly If the system cooling fans are no t operating properly , it is an indication of possible system component failure. Check the following: • Is the power-on light lit? If not, see “Power Light Does Not Light” .
114 Intel ® Server System SR1680MV Service Guide LE D I nfo r m at i o n The Intel ® Server SR6880MV includes LEDs that can aid in troublesho oting your system. A table of these LEDs with a description of their use is listed below . BIOS POST Beep Codes The table below lists the POST error beep code s.
Intel ® Server System SR1680MV Service Guide 115 In addition to the beep codes above, additio nal beep codes are provided if an Intel ® Management Module is inst alled. The Intel ® Management Module provides the following additional beep codes. T able 47.
116 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 117 Appendix C: Ins tallation/Assembly Saf e ty Ins tructions English The power supply in this product contains no user-serviceable par ts. There may be more than one supply in this product. Refer ser vicing only to qualified personnel.
118 Intel ® Server System SR1680MV Service Guide After you ha ve completed the six SAFETY steps abov e, you can remov e the system co vers . T o do this: 1. Unloc k and remo ve th e padloc k from the bac k of the system if a padlock has been installed.
Intel ® Server System SR1680MV Service Guide 119 Deutsch Benutzer können am Netzgerät dieses Produkts keine Reparaturen vornehmen. Das Produkt en thält möglicherweise mehrere Netzgeräte. W ar tungsarbeiten müssen von qualifizier ten T echnikern ausgeführ t werden.
120 Intel ® Server System SR1680MV Service Guide SICHERHEITSMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollte n Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen P eripher iegeräte a us.
Intel ® Server System SR1680MV Service Guide 121 Fr ançais Das System wurde für den Betrieb in ein er normalen Büroumgebung entwic kelt. Der Standor t sollte: • "sauber und staubfrei sein (.
122 Intel ® Server System SR1680MV Service Guide CONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l'intérieur du système, suivez les consignes suivantes: 1. Mettez hors tension tous les pér iphér iques connectés au système.
Intel ® Server System SR1680MV Service Guide 123 Español Danger d'explosion si la batter ie n'est pas remontée correctement. Remplacer uniquement av ec une batter ie du même type ou d'un type équivalent recommandé par le f abr icant.
124 Intel ® Server System SR1680MV Service Guide Nótese que el interruptor activado/desactivado en el panel frontal no desconecta l a corriente al ter na del sistema. P ara desconectarla, deberá desenchufar todos los cab les de corr iente alter na de la pared o desconectar la fuente de al imentación.
Intel ® Server System SR1680MV Service Guide 125 Italiano Si el sistema ha estado en funcionam iento, el microprocesador y el disipador de calor pueden estar aún cal ientes. T ambién con viene tener en cuenta que en el chas is o en el tablero puede haber piezas cor tantes o punzantes.
126 Intel ® Server System SR1680MV Service Guide Non modificare o uti lizzare il cav o di alimentazione in c.a . f or nito dal produttore, se non corrisponde esattamente al tipo r ichiesto . Ad ogni fonte di alimentazione corrispo nde un cav o di alimentazione in c.
Intel ® Server System SR1680MV Service Guide 127 Se il sistema è stato a lungo in funzione, il microprocessore e il dissipatore di calore potrebber o essere surriscaldati. F are attenzione alla presenza di piedi ni appuntiti e par ti taglie nti sulle schede e sul telaio .
128 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 129 Appendix D: Saf e ty In f ormation English Serv er Saf e ty In f orma tion This document applies to Intel ® server boards, Intel ® server chassis and ins talled peripherals.
130 Intel ® Server System SR1680MV Service Guide Intended Applica tion Uses This product was evaluated as Information T echnology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial ty pe locations.
Intel ® Server System SR1680MV Service Guide 131 • Conform to local occupationa l health and safety requirements when moving and lifting equipment. • Use mechanical assistance or other suita ble assistance when moving and lifting equipment. • T o reduce the weight for easier handling, remove any easily detachable components.
132 Intel ® Server System SR1680MV Service Guide • Do not access the inside of the power supp ly . There ar e no ser viceable parts in the power supply . Return to manufactur er for ser vicing. • Power down the chassis and disconn ect all power cor ds befor e adding or r eplacing any non hot-p lug component.
Intel ® Server System SR1680MV Service Guide 133 For pr oper coolin g and airflow , operate the chas sis only with the chassis covers installed. Operating the chassis without the covers in pla ce can damage chassis parts.
134 Intel ® Server System SR1680MV Service Guide Sicherheitshinw eise und V orsichtsmaßnahmen Um V erletzungen und Beschä digungen zu vermeiden, so llten Sie vor dem Beginn der Produktinstallation die nachfolgend aufgefü hrten Sicherheitshinweise und -informationen sorgfältig lesen und befolgen.
Intel ® Server System SR1680MV Service Guide 135 • Abgeschirmt von starken elek tromagnetis chen Feldern, di e durch elektrisch e Geräte erzeugt werden. • In gewittergefährdeten Gebieten sollten Sie das System an einen Überspannungsschu tz anschließen und bei einem Gewitter die T elekommunikationskabel zum Modem abziehen.
136 Intel ® Server System SR1680MV Service Guide W arnungen zu Ne tzspannung und Elektrizität Vo r s i c h t : Dur ch Betätigen der mit dem S tandby-Symbol g ekennzeichneten Netztaste wir d das System NICHT vollständig vom Netz getr ennt. Es sind weiterhin 5 V aktiv , solange das System eingesteckt ist.
Intel ® Server System SR1680MV Service Guide 137 • Schalten Sie den Se rver aus, und ziehen Sie alle Ne tzkabel ab, bevor Sie Komponenten ein- oder ausbauen, die nicht hot-plu g-fähig sind. • W enn Sie ein hot-plug-fähiges Netzteil aust auschen, ziehen Sie dessen Netzkabel ab, bevor Sie es aus dem Server ausbauen.
138 Intel ® Server System SR1680MV Service Guide Ander e Gefahr en Ba tterieaustausch Vo r s i c h t : W ir d die Batterie u nsachgemäß ausgetauscht, besteht Explosionsgefahr . V er wenden Sie als Ersatz nur die vom Gerätehersteller empfohlene Batterie.
Intel ® Server System SR1680MV Service Guide 139 Fr ançais Consignes de sécurité sur le serv eur Ce document s’applique aux cartes serveur Intel ® , au châssis de serveur Intel ® (sur pieds et sur rack) et aux périphériques installés.
140 Intel ® Server System SR1680MV Service Guide Domaines d’utilisa tion pr évus Ce produit a été testé comme équipement informa tique (ITE) et peut être installé dans des bureaux, des écoles, des sall es informatiques et des endro its commerciaux similaires.
Intel ® Server System SR1680MV Service Guide 141 Alimen ta tion et av ertissemen ts en ma tièr e d’électricité Attention: Le bouton d’alimentation, indiqué par le symbole de mise en veille, NE COUPE P AS complètement l’alimentation sec teur du système car le courant de veille 5 V r este actif lorsque le système est sous tension.
142 Intel ® Server System SR1680MV Service Guide Attention: Si le serveur a été utilisé, les pr ocesseurs et dissipateurs de ch aleur installés peuvent êtr e chauds. À moins qu e vous n’ajoutiez ou ne r etiri ez un composant connectable à chaud, laissez le système r efr oidir avant d’ouvrir les panneaux.
Intel ® Server System SR1680MV Service Guide 143 • Vérifiez tout d’abord que vous n’avez pas ou blié d’outils ou de composants détachés à l’intérieur du système. • Vérifiez que les câbles, les cartes d’ex tension et les autres composants sont correctement installés.
144 Intel ® Server System SR1680MV Service Guide Aplicaciones y usos pr evis tos Este producto ha sido ev aluado como equi po de tecnología informática (ITE) que pued e instalarse en oficinas, escuelas, salas de equipos informáticos o lugares de ámbito comercial similares.
Intel ® Server System SR1680MV Service Guide 145 • Provista de un a toma de corriente a lterna correctamente conectada a tierra. • Provista de espacio suficiente pa ra acceder a los cables de la fuente de alimentación ya que constituyen la desconexión principal de la alimentación.
146 Intel ® Server System SR1680MV Service Guide puede haber niveles de tensión, corriente y ener gía peligr oso s. Devuélvala al fabricante para r epararla.
Intel ® Server System SR1680MV Service Guide 147 de conexión en funcionamien to, tenga cuidado al extraer o instalar los componentes de conexión en funcionamiento. Precauci ón: Para evitar posibles daños, no toque las aspas en movimiento de los ventilador es.
148 Intel ® Server System SR1680MV Service Guide • Sujete las cubiertas a la car casa siguiendo las instru cciones del pr oducto. Perif éric os o dispositiv os láser Precaución: Para evitar el r.
Intel ® Server System SR1680MV Service Guide 149 简体中文 服务器安全信息 本文档适用于 Intel® 服务器主板、Intel® 服务器 机箱 (基座和 机架固定 件)和已安装.
150 Intel ® Server System SR1680MV Service Guide 预期应用使用 根据评估,本产 品为信息 技术设备 (ITE),可安装在 办公室、学校、计算机 房和类似 的商业场所。.
Intel ® Server System SR1680MV Service Guide 151 为避免电击,请 在打开服务器之前 ,关闭服务器 并断开服务器上连接的 电源线、电 信系统、网络和 调制解调器.
152 Intel ® Server System SR1680MV Service Guide 注意事项 为避免 受伤,请勿 触摸运转的 风机叶 片。如果系统的 风机 上配有防护装 置,请勿卸 下风机防护装置.
Intel ® Server System SR1680MV Service Guide 153 其他危险 替换电池 注意事项 不正确替换电池 可能导致 爆炸危险。替换 电池时, 请只使用设备生 产商推荐使 用.
154 Intel ® Server System SR1680MV Service Guide.
Intel® Server System SR1680MV Service Guide 155 Appendix E: Regula tory and Certifica tion In f orma tion Wa r n i n g : T o ensur e r egulatory compliance, you must adher e to the a ssembly instructions in this guide to ensur e and mainta in compliance with existing pr oduct certifications and appr ovals.
156 Intel® Server System SR1680MV Service Guide Pr oduct Sa fe ty Compliance • UL60950 - CSA 60950 (USA / Canada) • EN60950 (Europe) • IEC60950 (International) • CB Certificate & Report, .
Intel® Server System SR1680MV Service Guide 157 Pr oduct Ec ology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide regulatory requirem ents. A Material Declarati on Data Sheet is available for Intel products.
158 Intel® Server System SR1680MV Service Guide Pr oduct R egula tory Compliance Markings This Intel Server Chassis product if provide d with the f ollowing regulatory and safety markings. In the event there is no room for a marking(s) on th e chassis, the information is provided here in thi s guide.
Intel® Server System SR1680MV Service Guide 159 VCCI Mar k Jap a n KCC Mar k Ko r e a 인증번호 : CPU-SR1680 (A) GOST Mar k Russia MO04 BSMI Mark Ta i w a n R33025 T able 48.
160 Intel® Server System SR1680MV Service Guide UL Mark USA / Canada FCC Mark USA (FCC Mark) This device complies with Part 15 of the FCC Rules. Operation of this de vice is subject to the following .
Intel® Server System SR1680MV Service Guide 161 Multiple Po wer Cord Multiple P ow er Cord English: This unit has more than one power supply cord. To reduce the risk of electrical shock, disconnect (2) two power supply cords before servicing.
162 Intel® Server System SR1680MV Service Guide China Recycling P ackage Mark s China Recycling P ackage Marks Will be added on Package label. Other Recyclin g P ackage Mark s Will be added on Package label. Lithium P erchlorate inser t CA Perchlorate Ma terial – Special hand ling may apply.
Intel® Server System SR1680MV Service Guide 163 Rack Moun t Installa tion Guidelines Anchor the equipment rack: The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of the rack on slides.
164 Intel® Server System SR1680MV Service Guide Overcurrent protection: The server is design ed for an AC line volta ge source with up to 20 amperes of overcurrent pro tection per cord feed.
Intel® Server System SR1680MV Service Guide 165 showing certificatio n by an agency acceptable in you r r egion and for U. S. must be Listed and rated 125% of overa ll curr ent rating of the server .
166 Intel® Server System SR1680MV Service Guide Electr omagne tic C ompa tibility No tices FCC V erifica tion S ta temen t (USA) This device complies w ith Part 15 of the FCC Rules.
Intel® Server System SR1680MV Service Guide 167 ICES-003 (Canada) Cet appareil numérique respec te les limites bruits radioé lectriques applicables aux appareils numériques de Classe A prescrites da ns la norme sur le matériel brouilleur: "Apparelis Numériques", NMB-003 édictee par le Mi nistre Canadian des Communications.
168 Intel® Server System SR1680MV Service Guide BSMI (T aiwan) The BSMI Certification Marking and EMC warning is located on the outside rear area of the product. K CC (K or ea) Following is the KCC certification information for Korea. English translation of the notice above: 1.
Intel® Server System SR1680MV Service Guide 169 If you do not have access to Intel's W eb addre ss, please contact your local Intel representative. • Server Chassis: (base chass is is provided with po wer supply and fans) - UL listed. • Server board: you must use an Intel serv er board - UL recognized.
170 Intel® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 171 Appendix F: W arr anty T o obtain warranty service for this Pro duct, visit the following Intel website: http://support.
172 Intel ® Server System SR1680MV Service Guide.
Intel ® Server System SR1680MV Service Guide 173 Appendix G: Ge tting Help If you encounter an issue with your server system, follow these steps to obtain support: 1.
174 Intel ® Server System SR1680MV Service Guide.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Intel SR1680MV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Intel SR1680MV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Intel SR1680MV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Intel SR1680MV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Intel SR1680MV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Intel SR1680MV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Intel SR1680MV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Intel SR1680MV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.