A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products
Intel Order Number E17409-002
Intel® Server System SR1520ML User’s Guide i

Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.
Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
* Other names and brands may be claimed as the property of others.
Copyright © 2007, Intel Corporation. All Rights Reserved
ii Intel® Server System SR1520ML User’s Guide
Disclaimer

Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm.
Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel® Server Deployment Toolkit 2.0 CD oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm
Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel® Server Deployment Toolkit 2.0 CD ou bien rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs- 010770.htm.
Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel® Server Deployment Toolkit 2.0 CD y/o en http:// support.intel.com/support/motherboards/server/sb/cs-010770.htm
Intel® Server System SR1520ML User’s Guide iii

在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。
Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
iv Intel® Server System SR1520ML User’s Guide

Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.
Intel® Server System SR1520ML User’s Guide v

vi Intel® Server System SR1520ML User’s Guide






xii Intel® Server System SR1520ML User’s Guide


xiv Intel® Server System SR1520ML User’s Guide



About this Manual
Thank you for purchasing and using the Intel® Server System SR1520ML.
This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add and replace components on the server system. For the latest version of this manual, see http:// support.intel.com/support/motherboards/server/X38ML/
Chapter 1 provides an overview of the server system. In this chapter, you will find a list of the server system features, illustrations of the product, and product diagrams to help you identify components and their locations.
Chapter 2 provides instructions on adding and replacing components. Use this chapter for step-by-step instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.
Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes how to navigate through the BIOS Setup screens, how to perform a BIOS update, and how to reset the password or CMOS. Information about the specific BIOS settings and screens is available in the Technical Product Specifications for the server board and chassis. See Table 1 on page xix for a link to the Technical Product Specifications.
At the back of this manual, you will find technical specifications, troubleshooting tips, regulatory information, complete safety information, “getting help” information, and the warranty.
Intel® Server System SR1520ML User’s Guide xvii

Your Intel® Server System SR1520ML ships with the following items.
— Two memory cooling fans
— Two system blower fans
— Two SATA cables, installed in the server system
— Two front panel / Z-U130 USB Y-cables, installed in the server system
— One front panel Y-cable, installed in the server system
xviii Intel® Server System SR1520ML User’s Guide

If you need more information about this product or information about the accessories that can be used with this server chassis, use the following resources.
Table 1. Server System References
For this Information or
Software Use this Document or Software
Technical information about the server chassis, including sub-system overviews and mechanical drawings
Intel® Server System SR1520MLTechnical Product Specification
At http://support.intel.com/support/motherboards/server/X38ML/
Technical information about the server board, including board layout, connector pin-outs, timing information, mechanical drawings and LED information
Intel® Server Board X38ML Technical Product Specification
At http://support.intel.com/support/motherboards/server/X38ML
Technical information about the server system, including connector pin- outs, timing information, mechanical drawings and LED information
Intel® Server System SR1520ML Technical Product Specification
At http://support.intel.com/support/motherboards/server/X38ML/
If you just received this product and need to install it
Intel® Server System SR1520ML Quick Start User's Guide
In the product box
Accessories or other Intel server products
Spares and Configuration Guide
Available from your Intel field representative or on the Server Configurator Tool at http://indigo.intel.com/serverconfiguratortool/ default.aspx
Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product
Tested Hardware and Operating Systems List
At http://support.intel.com/support/motherboards/server/X38ML/
Processor and DIMMs that have been tested with this produc
See http://support.intel.com/support/motherboards/server/X38ML/
For drivers Search for the word “driver” (for an extensive list of available drivers)
Search for “operating system driver” (for operating system drivers)
For firmware and BIOS updates, or for BIOS recovery
Intel® Server System SR1520ML User’s Guide xix
Firmware Updates

Table 1. Server System References
For this Information or
Software Use this Document or Software
For software to manage your Intel® server
Intel® System Management Software Software 2.0
At http://support.intel.com/support/motherboards/server/X38ML/
To make sure your system falls within the allowed power budget
Search for the phrase “Power Budget Tool”
At http://support.intel.com/support/motherboards/server/X38ML/
For diagnostics test software
Search for the word “Diagnostics”
xx Intel® Server System SR1520ML User’s Guide

This chapter briefly describes the main features of the server system. It provides product illustrations, a list of the server system features, and diagrams that show the location of important components and connections.

Figure 1. Intel® Server System SR1520ML
The Intel® Server System SR1520ML ships with two Intel® Server Boards X38ML installed in it. Each server board operates as a fully functioning server system with it’s own control panel, BIOS setup configuration, processor, memory, drives, add-in card, keyboard/mouse, and video monitor. These items are not shared by the two server boards. The two server boards share the chassis and power supply.
Since the server boards function independently, the processor and DIMM rules apply to each board independently. The two server boards do not need to use identical processors or DIMMs.

Table 2 summarizes the features of the server system.
Table 2. Feature Summary
Server board Intel® Server Board X38ML. Two per system.
Processors Processor and Front Side Bus (FSB) support
Chipset Intel® X38 chipset on each server board, consisting of:
Peripheral Interfaces External connections on each server board:
Video Each server board has an on-board video controller with 32 MB DDR2 667 video memory
LAN Two Intel® 10 / 100 / 1000 82573E Gigabit Ethernet controllers on each server board
Expansion capabilities One low-profile PCI Express* riser card for each server board. Each supports one low-profile x1, x4, x8, or x16 adapter.
Feature Description

Table 2. Feature Summary
Control panel Each server board has a control panel. Each control panel includes:
Power supply One 600-watt power supply module
System management Intel® System Management 2.0 Software
This section helps you identify the components of your server system. If you are near the system, you can also use the quick reference label on the inside of the chassis cover to assist in identifying components.
Each server board has its own control panel at the front of the server system. Each control panel includes the following buttons and LEDs.
Feature Description


A USB connector 2.0 port, 4-pin connectors
Front Panel Buttons and LED Indicators

Press to turn the system power on or off
C Power / sleep LED Green LED for system power status
Item Feature Description · Front Panel Connector

D System status / fault LED
Green / amber LED for system status.
LED Statte System State
Off System not ready
Green on System ready, no alarm
Green blink System ready but degraded by processor or DIMM error
Amber blink Non critical failure, such as non-critical power or voltabe error
Amber on Critical alarm. Critical power module failure, critical fan failure, power supply, voltage or thermal fault
E LAN1, LAN 2 Status LEDs
Green LEDs that show the status of each LAN port
LED State LAN State
On LAN link / no access
F Hard drive activity LED
Green LED that indicates hard drive activity
LED State Drive State
Green blink Drive is active
Off Drive is not active
G System reset button Press to reset the system
Figure 2. Front Controls and LEDs
Item Feature Description · Off Idle · Blinking Active

Except for the shared AC power supply, each server board has its own back panel connectors.


B. PCI Express* add-in card slot location (one for each server board)
F. NIC 2 (10 / 100 / 1000 Mb) (one for each server board)
C. NIC 1 (10 / 100 / 1000 Mb) (one for each server board)
G. USB ports 0-1 (one sets of two ports for each server board)
Figure 3. Back Panel Connectors
The LEDs at the right and left of each NIC provide the following information.
Table 3. NIC LED Descriptions

Right Off 10 Mbps connection (if left LED is on or blinking)

The server system provides locations for installing up to two fixed 2.5-inch SATA hard drives and up to two Intel® Z-U130 Value Solid State Drive (Intel® VSSD). Each server board controls one of each of these drives. No optical or floppy drive bays are available, but these devices are supported through an external USB connection. The drives must be purchased separately. The following figure shows the available options.

A. Two 2.5-inch hard drive bays, stacked on top of each other
B. Two Intel® Z-U130 Value Solid State Drive bays
Figure 4. Optional Peripherals
For instructions on installing a hard drive, see “Installing and Removing a Hard Drive” on page 15.
For instructions on installing the Intel® Z-U130 Value Solid State Drive, see the document titled Intel® Z-U130 Value Solid State Drive Mounting Kit Installation Guide for Intel® Server Systems.
maximum ambient temperature of 45oC.
See “Server System References” on page xix for an Internet link to a list of supported hardware.



B. Processor and memory air duct (two) F. Hard drive bracket (one bracket for two 2.5-inch drives)
C. Processor and heat sink (two) G. Front control panel (two)
D. PCI add-in card bracket (two) H. System blower fans (two)
Figure 5. System Components
The two Intel® Server Boards X38ML have the same connectors / components.



A. NIC1 RJ45 connector (top) I. Processor socket Q. DIMM socket B1
B. USB port 0 (bottom) USB port 1 (center)
C. NIC2 RJ45 connector K. System fan 3 S. SATA port 0
D. CMOS battery L. System fan 2 T. SATA port 1
E. Serial A DB9 connector M. System fan 1 U. SATA port 2
F. VGA connector N. Main power connector V. SATA port 3
G. POST LEDs O. DIMM socket A1 W. USB header for USB 2 and 3
H. PCI Express* x16 riser slot P. DIMM socket A2 X. Chassis intrusion header
Figure 6. Server Board Connector Locations

The two Intel® Server Boards X38ML have the same jumpers.
D
B
E
Callout Location Jumper Name Jumper Purpose
A J1A4 iBMC Boot Block Write Protect
When pins 2-3 are jumpered, the iBMC boot block is write enabled. When pins 1-2 are jumpered, the iBMC boot block is write protected. Pins 1-2 should be jumpered for normal operation.
B J1A2 BIOS Recovery Mode
When pins 2-3 are jumpered, the BIOS will be recovered on the next boot. Pins 1-2 should be jumpered for normal operation.
C J1A3 CMOS Clear When pins 2-3 are jumpered, the CMOS settings will be cleared on the next boot. Pins 1-2 should be jumpered for normal operation.
D J3A1 iBMC Force Update Mode
When pins 2-3 are jumpered, the iBMC firmware will be updated on the next boot. Pins 1-2 should be jumpered for normal operation.
E J6B1 Password Clear
When pins 2-3 are jumpered, the administrator and user passwords will be reset on the next boot. Pins 1-2 should be jumpered for normal operation.
Figure 7. Configuration Jumpers

The Intel® Server System SR1520ML provides SATA (3.0 Gb/s) support.The embedded SATA controller embedded supports both 1.5 and 3.0 Gbps data transfer rates. The Intel® RAID Technology solution, available with the ICH9R, offers data striping for higher performance (RAID Level 0) and mirroring for higher reliability (RAID Level 1).
The BIOS Setup utility provides multiple drive configuration options on the Advanced | ATA Controller setup page, some of which affect the ability to configure RAID. The “Onboard SATA Controller” option is enabled by default. When this option is enabled, the “Configure SATA as” option can be set to either IDE, AHCI, or RAID.
For assistance in navigating through the F2 BIOS Setup utility, see the Intel® Server Board X38ML Technical Product Specification.
For information about setting up RAID, see the RAID Software Guide that is included on the Intel® Server Deployment Toolkit 2.0 CD.
The server system can be mounted into a 19-inch wide by up to a 30-inch deep server cabinet. The system ships with a basic slide rail kit and supports optionsl fixed-mount and tool-less slide rail kits:
To avoid integration difficulties and possible board damage, your system must meet the requirements outlined below. For a list of qualified components, see the links under "Server System References."

Each server board must have one processor installed. Each board can use a different processor. For a list of supported processors, see http://support.intel/com/support/ motherboards/server/X38ML.
Each server supports four DDR2 667 / 800 MHz unbuffered ECC DIMMs. The maximum memory capacity is 2 GB unbuffered, 1 Gbit DDR2 memory. The minimum is one 256- MB DIMM. The four slots are partitioned into Channel A and Channel B. Channel A consists of DIMM A1 and DIMM A2. Channel Bconsists of DIMM B1 and DIMM B2. DIMM A1 is the closest to the MCH.
DIMMs must meet the following requirements:
For a complete list of supported memory DIMMs, see http://support.intel/com/support/ motherboards/server/X38ML.

removing or installing any component in this server system, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button(s), and unplug the AC power cord from the system or wall outlet.
Before working with your server product, pay close attention to the “Safety Information” on page iii.
All references to left, right, front, top, and bottom assume the reader is facing the front of the server system as it would be positioned for normal operation.

The server system must be operated with the cover in place to ensure proper cooling. You will need to remove the cover to add or replace components inside of the server.
None of the internal components are hot-swappable. Before removing the server system cover, power down the server and unplug all peripheral devices and the AC power cable.
system from sliding on your work surface.

Figure 8. Removing the Server System Cover


Figure 9. Installing the Server System Cover
must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
One SATA drive can be installed for each server board (two drives total). Both drive bays are at the right side of the chassis.

page xix for an Internet link to a list of supported hardware.
instructions first. Return to these steps when directed.

Figure 10. Removing Drive Carrier from the Server System


assembly into the server.
— Connect the power cable labeled “P4” to the bottom drive.
— Connect the power cable labeled “P3” to the top drive.


Figure 11. Installing Drive Assembly


Figure 12. Removing Drive Carrier


Figure 13. Installing the Drive Carrier
you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

cable is attached to the front panel board. The other cable is loose. This loose cable is for the Intel® VSSD.
riser assembly, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
To remove the PCI riser assembly, use the following instructions.


Figure 14. Removing PCI Riser Assembly
If you are installing an add-in card, do so before installing the PCI riser assembly into your server system.


Figure 15. Installing PCI Riser Assembly into the Server System

card, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
AF002533 A
Figure 16. Removing Riser Card from Riser Assembly
— Install an add-in card. For instructions, see “Installing a PCI Add-in Card” on page 26.

— Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 22.
AF002650 B
Figure 17. Installing Riser Card onto Riser Assembly
— Install a PCI add-in card if desired. For instructions, see “Installing a PCI Add- in Card” on page 26.
— Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 22.

you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Figure 18. Installing an Add-In Card


Figure 19. Removing an Add-In Card

Always operate your server system with the processor air duct in place. The air duct is required for proper airflow within the server system.

Figure 20. Removing the Processor Air Duct


Figure 21. Installing the Processor Air Duct
you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

The silkscreen on the board for the DIMMs displays DIMMB2, DIMMB1, DIMMA2, DIMMA1 starting from the edge of the board. DIMMA1 is the socket closest to the processor socket. See “Memory” on page 12 for a discussion of the memory requirements and options. See “Server System References” on page xix for a link to the list of tested DIMMs.
Each server board in the Intel® Server System SR1520ML provides four DIMM sockets across two banks. For each server board, Bank 1 consists of DIMM sockets A1 and B1. Bank 2 consists of DIMM sockets A2 and B2. For single-channel operation, either channel may be used and DIMM sockets within the same channel can be populated in any order. For dual-channel asymetric mode, DIMM sockets may be populated in any order.
DIMMs must meet the following requirements:
For dual-channel operation, the following conditions must be met:
For a complete list of supported memory DIMMs, see http://support.intel/com/support/ motherboards/server/X38ML.
To install DIMMs, follow these steps:


DIMM Socket B2 DIMM Socket B1 DIMM Socket A2 DIMM Socket A1
Figure 22. Installing Memory DIMMs

To remove a DIMM, follow these steps:

DIMM Socket B2 DIMM Socket B1 DIMM Socket A2 DIMM Socket A1
Figure 23. Removing Memory DIMMs

to replace your processor. If you are setting up this system for the first time, see the Quick Start User’s Guide that was included in the product box.
System References” on page xix for a link to the list of compatible processor(s).
the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. (2) Avoid moving around unnecessarily.

Figure 24. Opening the Processor Socket Handle

Figure 25. Opening the Load Plate


Figure 26. Removing the Processor
These steps assume you have just removed your heat sink and processor and your server system is powered down and unplugged. If this is not true, see “Removing the Heat Sink and Processor” on page 33 before following these steps.


Figure 27. Installing the Processor
Install the processor before installing the heat sink. For instructions, see “Installing the Processor” on page 35.


Figure 28. Installing the Heat Sink
you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
The power supply can be replaced if it fails or if one of the fans that is integrated into it fails. To replace the power supply, use the following instructions.

— From each server board, disconnect the main power cable. This connector is labeled P1 for the board on the right, and P2 for the board on the left. See letters “A” and “B” in the following figure
— From each hard drive, disconnect the power cable. The connector to the top drive is labeled P3 and the connector to the bottom drive is labeled P4. See letters “C” and “D” in the figure. .

Figure 29. Disconnecting Power Cables




— On each board, connect the main power cable. This connector is labeled P1 for the board on the right, and P2 for the board on the left. See letters “A” and “B” in Figure 29 on page 38.
— On each hard drive, connect the power cable. The connector to the top drive is labeled P3 and the connector to the bottom drive is labeled P4. See letters “C” and “D” in Figure 29 on page 38
The individual blower fans and memory cooling fans can be replaced if a fan fails. The fans that are integrated into the power supply cannot be replaced. If one of the fans in the power supply fails, the power supply must be replaced.
must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.


Figure 32. Disconnecting Cables


Figure 33. Removing Bracket and Fans


Figure 34. Removing Fan from Fan Bracket





cable.
— Main power. The cable end is labeled P1 for the server board at the right and P2 for the server board at the left. Press and hold down on the tab at the center of the connector while you pull on the connector.
— SATA_0
— Front panel · — Sys_fan_3


Figure 37. Removing the Server Board
— Install a replacement the server board. For instructions, see “Installing the Server Board” on page 48.
— Continue with the following steps to reassemble and close the server system without replacing the server board.


Figure 38. Installing the Server Board

— Main power. The cable end is labeled P1 for the server board at the right and P2 for the server board at the left. Several cables lay underneath this connector. Be sure the cables do not get pinched in the connector. See letter “A” in the following figure.
— Front panel (letter “E”)
— Sys_fan_3 (letter “D”)
— USB_2_3 (letter “C”)
— SATA_0 (letter “B”)

Figure 39. Connecting Cables to Server Board

you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.
Your server must be operated with a control panel installed.
cables.
board.


Figure 40. Removing Front Panel Board


Figure 41. Installing Front Panel Board
battery, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

The lithium battery on the server board powers the RTC in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices.
equivalent type recommended by the equipment manufacturer. Discard used batteries according to manufacturer's instructions.
batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.
apparatfabrikanten. Brukt batteri returneres apparatleverandøren.
Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.
laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.


Figure 42. Removing the CMOS Battery


Figure 43. Installing the Rack Handle


Figure 44. Removing the Rack Handle

Using the BIOS Setup Utility
This section describes the BIOS Setup Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See Table 1 on page xix for a link to the Technical Product Specification where you will find details about specific BIOS setup screens.
You can enter and start BIOS Setup under several conditions:
In the two conditions listed above, during the Power On Self Test (POST), you will see this prompt: Press to enter SETUP
In a third condition, when CMOS/NVRAM has been corrupted, you will see other prompts but not the prompt: Warning: CMOS checksum invalid Warning: CMOS time and date not set
In this condition, the BIOS will load default values for CMOS and attempt to boot.
If you are not able to access BIOS Setup, you might need to clear the CMOS memory. For instructions on clearing the CMOS, see "Clearing the CMOS".
Each BIOS Setup menu page contains a number of features. Except for those features that are provided only to display automatically configured information, each feature is associated with a value field that contains user-selectable parameters. These parameters can be changed if the user has adequate security rights. If a value cannot be changed for any reason, the feature's value field is inaccessible.

“Setup Menu Key Use” describes the keyboard commands you can use in the BIOS Setup menus.
Table 4. Setup Menu Key Use
Key to Press Description
Execute Command - The key is used to activate submenus when the selected feature is a submenu, or to display a pick list if a selected feature has a value field, or to select a sub-field for multi-valued features like time and date. If a pick list is displayed, the key will undo the pick list, and allow another selection in the parent menu.
Exit - The key provides a mechanism for backing out of any field. This key will undo the pressing of the key. When the key is pressed while editing any field or selecting features of a menu, the parent menu is re-entered. When the key is pressed in any submenu, the parent menu is re-entered. When the key is pressed in any major menu, the exit confirmation window is displayed and the user is asked whether changes can be discarded.
Left and right arrows The left and right arrow keys are used to move between the major menu pages. The keys have no affect if a submenu or pick list is displayed.
Up arrow Select Item up - The up arrow is used to select the previous value in a menu item's option list, or a value field pick list. Pressing the key activates the selected item.
Down arrow Select Item down - The down arrow is used to select the next value in a menu item's option list, or a value field pick list. Pressing the key activates the selected item.
Change Value - The minus key or the function key is used to change the value of the current item to the previous value. This key scrolls through the values in the associated pick list without displaying the full list.
Change Value - The plus key or the function key is used to change the value of the current menu item to the next value. This key scrolls through the values in the associated pick list without displaying the full list. On 106-key Japanese keyboards, the plus key has a different scan code than the plus key on the other keyboard, but it has the same effect.
Pressing on any menu invokes the general help window.
Setup Defaults - Pressing causes the following to appear:
[Yes] [No] If "Yes" is selected and the key is pressed, all Setup fields are set to their default values. If "No" is selected and the key is pressed, or if the key is pressed, the user is returned to where they were before was pressed without affecting any existing field values.
Load Optimized Defaults?

Table 4. Setup Menu Key Use
Key to Press Description
Save and Exit - Pressing causes the following message to appear:
Save Configuration and reset?
[Yes] [No] If "Yes" is selected and the key is pressed, all changes are saved and Setup is exited. If "No" is selected and the key is pressed, or the key is pressed, the user is returned to where they were before was pressed without affecting any existing values.
The upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in the upgrade file include the following:
The steps below explain how to prepare to upgrade the BIOS, including how to record the current BIOS settings and how to obtain the upgrade utility.
process may need to be followed to return the system to service. See Table 1 on page xix for a link to necessary software and instrutions.
the procedure.

Download the BIOS image file to a temporary folder on your hard drive. See Table 1 on page xix for a link to the update software.
with the BIOS image file before attempting a BIOS upgrade. The release notes contain critical information regarding jumper settings, specific fixes, or other information to complete the upgrade.
Follow the instructions in the readme file that came with the BIOS upgrade. When the update completes, remove the bootable media from which you performed the upgrade.
automatically when the BIOS update process is completed.
happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, check your settings, save your settings, and exit Setup.


Figure 45. BIOS Recovery Mode Jumper in Recovery Position
The BIOS starts the recovery process by loading and booting to the recovery image file. Then the BIOS POST screen appears and displays the progress.

If the user or administrator password(s) is lost or forgotten, moving the password clear jumper into the "clear" position clears both passwords. The password clear jumper must be restored to its original position before a new password(s) can be set.

Figure 46. Password Clear Jumper in Clear Password Position

If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to be used to reset the configuration RAM.

Figure 47. CMOS Clear Jumper in Clear CMOS Position

When performing a standard iBMC firmware update procedure, the update utility places the iBMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event that the iBMC firmware update process fails because the iBMC not in the proper update state, the server board provides a BMC Force Update jumper (J3A1) that will force the iBMC into the proper update state. The following procedure should be following if the standard iBMC firmware update process fails.


Figure 48. MiBMC Force Update Jumper in the Write Enable Position

The iBMC boot block write protect jumper (J1A4) is protection for the boot block portion of the iBMC firmware. The default position of the jumper is covering pins 1-2. This protects the boot block from being written to during an iBMC firmware update. In most cases there is no need to update the boot block. Most update utilities are not built with the authority to access this section of code.
In the unlikely event that the boot block must be written to, the J1A4 jumper must be moved to cover pins 2-3 to enable the update. Once the update is complete and the system is turned off, always remember to reposition the jumper back to ‘write-protect’ mode, covering pins pins 1-2.
the iBMC hardware. If this flash area becomes corrupted, then the iBMC may be rendered useless and inoperable. For this reason jumper protection is applied to this area of the flash so a user does not mistakenly write to this boot block.

Cable Routing
When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing.



A. Memory fan (one for each server board) C. Main power (one for each server board)
B. Blower fan (one for each server board) D. Drive power. Daisy cable (one connection to power a drive for each server board)
Figure 49. Power Cable Routing



A. Y-USB cable. One end to Intel® Z-U130 Value Solid State Drive (optoinal). The other end to the front panel. (one for each server board
C. Y-Front panel cable. One end attaches to each server board.
B. SATA to hard drive. (one for each server board)
Figure 50. Data Cable Routing

The table below lists the total wattage available from the power subsystem for each voltage. For information about calculating the power usage for your configuration, see “Calculating Power Usage.”
Table 5. Power Supply Output Capability
+3.3 V 20 Amp
+5.0 V 24 Amp
+5.0 V Standby 3 Amp
+12.0 V1 16 Amp
+12.0 V2 16 Amp
+12.0 V3 16 Amp
+12.0 V4 16 Amp
-12.0 V 0.5 Amp
Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supply to overheat and malfunction.
Voltage Maximum Current

Table 6. System Environmental Specifications
-40 ° to 70 °C.
10 ° to 30 °C, with the maximum rate of change not to exceed 10 ° C per hour
Non-operating 90% relative humidity, non-condensing at 35 °C.
2.0 g, 11 msec, 1/2 sine
Operational after an 24-inch free fall.
Acoustic noise 7 Bels in sound power for a typical office ambient temperature (65-75 °F). Your selection of peripherals may change the noise level.
Tested to 15 kilovolts (kV); no component damage.



Safety Instructions
English
The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel.

Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply.
The power button on the system does not turn off system AC power. To remove AC power from the system, you must unplug each AC power cord from the wall outlet or power supply.

The power cord(s) is considered the disconnect device to the main (AC) power. The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessible.
SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps:
1. Turn off all peripheral devices connected to the system. 2. Turn off the system by pressing the power button. 3. Unplug all AC power cords from the system or from wall outlets. 4. Label and disconnect all cables connected to I/O connectors or ports on the back of the system. 5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed.

After you have completed the six SAFETY steps above, you can remove the system covers. To do this:

For proper cooling and airflow, always reinstall the chassis covers before turning on the system. Operating the system without the covers in place can damage system parts. To install the covers:

A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts. Contact should be made with care. Consider wearing protective gloves.
The system is designed to operate in a typical office environment. Choose a site that is:

This chapter helps you identify and solve problems that might occur while you are using the system.
For any issue, first ensure you are using the latest firmware and files. Firmware upgrades include updates for BIOS, and the Baseboard Management Controller (BMC). See “Server System References” on page xix for a link to the software updates. In addition to the server firmware and files, also update any drivers used for components you have installed in your system, such as video drivers, network drivers, and SATA drivers.
Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Server System References” on page xix for a link to this software.
If you are unable to resolve your server problems on your own, see “Getting Help” on page 95 for assistance.
Before going through in-depth troubleshooting, attempt first to reset your system using one of the methods below.
Table 7. Resetting the System
To do this Press
Soft boot reset to clear the system memory and reload the operating system
Clear system memory, restart POST, and reload the operating system Reset button
Cold boot reset. Turn the system power off and then on. This clears system memory, restarts POST, reloads the operating system, and halts power to all peripherals
Reset the BMC and get it back to a stable state Remove AC power from the server for one minute
· Power off/on button

Problems that occur at initial system startup are usually caused by an incorrect installation or configuration. Hardware failure is a less frequent cause. If the problem you are experiencing is with a specific software application, see “Problems with Newly Installed Application Software” on page 92.
This section provides a more detailed approach to identifying a hardware problem and locating its source.

from the system, turn off the system and any external peripheral devices. Failure to do so can cause permanent damage to the system and/or the peripheral devices.
As POST determines the system configuration, it tests for the presence of each mass storage device installed in the system. As each device is checked, its activity light should turn on briefly. Check for the following:
Once the system boots up, the operating system prompt appears on the screen. The prompt varies according to the operating system. If the operating system prompt does not appear, see “No Characters Appear on Screen” on page 88.
This section provides possible solutions for these specific problems:

Try the solutions below in the order given. If you cannot correct the problem, contact your service representative or authorized dealer for help.
Check the following:
Check the following:

If you are using an add-in video controller board, do the following:
Check the following:
If the system cooling fans are not operating properly, it is an indication of possible system component failure.
Check the following:

Check the following:
Check the following:

System Management features require full-time “standby” power. This means some parts of the system have power going to them whenever the power cord is plugged in, even if you have turned the system power off with the power button on the front panel. If you install a PCI card with the AC power cord plugged in, a signal may be sent to command the system to boot. Before installing a PCI card, you should always:

Problems that occur when you run new application software are usually related to the software, not the server hardware. Faulty equipment is unlikely, especially if other software runs correctly.
Check the following:
If the problems persist, contact the software vendor's customer service representative.
Problems that occur after the system hardware and software have been running correctly sometimes indicate equipment failure. However, they can also be caused by file corruption or changes to the software configuration.
Check the following:
be getting corrupted by voltage spikes on your power line. If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cord.

The Microsoft* Windows* operating systems do not include all of the drivers for the Intel® chipsets, onboard NICs, and other components. See “Server System References” on page xix for a link to the current drivers and chipset files.
Check the following:
Check the following:



World Wide Web
http://support.intel.com/support/motherboards/server/X38ML
All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice).
Before calling, fill out an Issue Report Form, available at http://support.intel.com/support/ motherboards/server/X38ML.
For an updated support contact list, see http://www.intel.com/support/9089.htm/
See http://support.intel.com/support/motherboards/server/X38ML
Belgium 02 714 3182
Denmark... 38 487077
Finland 9 693 79297
France 01 41 918529
Germany... 069 9509 6099
Holland 020 487 4562
Italy 02 696 33276
Norway 23 1620 50
Spain 91 377 8166
Sweden 08 445 1251

Australia 1800 649931
Cambodia.. 63 2 636 9797 (via Philippines)
China 800 820 1100 (toll-free)
8 621 33104691 (not toll-free)
Hong Kong 852 2 844 4456
India 0006517 2 68303634 (manual toll-free. You need an IDD-equipped
Indonesia... 803 65 7249
Korea 822 767 2595
Malaysia 1 800 80 1390
Myanmar... 63 2 636 9796 (via Philippines)
New Zealand 0800 444 365
Pakistan 632 63684 15 (IDD via Philippines)
Philippines 1 800 1 651 0117
Singapore.. 65 6213-1311
Taiwan 2 2545-1640
Thailand 1 800 631 0003
Vietnam 632 6368416 (IDD via Philippines)
Domestic 0120 868686
Outside country 81 298 47 0800
Argentina.. Contact AT&T USA at 0-800 222 1288. Once connected, dial 800 843 4481
Brazil 001-916 377 0180
Easter Island Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan.. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481
telephone) · Chile

Colombia... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481
Costa Rica. Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481
(Andimate) Contact AT&T USA at 1 999 119. Once connected, dial 800 843 4481 (Pacifictel) Contact AT&T USA at 1 800 225 528. Once connected, dial 800 843 4481
Guatemala. Contact AT&T USA at 99 99 190. Once connected, dial 800 843 4481
Mexico Contact AT&T USA at 001 800 462 628 4240. Once connected, dial 800 843
Miami 1 800 621 8423
Panama Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481
Paraguay... 001 916 377 0114
Peru 001 916 377 0114
Uruguay 001 916 377 0114
Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481
Ecuador



Limited Warranty for Intel® Chassis Subassembly Products
Intel warrants that the Products (defined herein as the Intel® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and installed, will be free from defects in material and workmanship and will substantially conform to Intel's publicly available specifications for a period of three (3) years after the date the Product was purchased from an Intel authorized distributor. Software of any kind delivered with or as part of products is expressly provided "as is" unless specifically provided for otherwise in any software license accompanying the software.
If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will:
If such Product is defective, transportation charges for the return of Product to buyer within the USA will be paid by Intel. For all other locations, the warranty excludes all costs of shipping, customs clearance, and other related charges. Intel will have a reasonable time to make repairs or to replace Product or to refund the then-current value of the Product.
In no event will Intel be liable for any other costs associated with the replacement or repair of Product, including labor, installation or other costs incurred by buyer and in particular, any costs relating to the removal or replacement of any product soldered or otherwise permanently affixed to any printed circuit board.
This Limited Warranty, and any implied warranties that may exist under state law, apply only to the original purchaser of the Product.
Intel does not warrant that Products to be delivered hereunder, whether delivered stand- alone or integrated with other Products, including without limitation semiconductor components, will be free from design defects or errors known as "errata." Current characterized errata are available upon request.

This Limited Warranty does not cover damages due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing.
These warranties replace all other warranties, expressed or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel makes no expressed warranties beyond those stated here. Intel disclaims all other warranties, expressed or implied including, without limitation, implied warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not allow the exclusion of implied warranties, so this limitation may not apply.
All expressed and implied warranties are limited in duration to the limited warranty period. No warranties apply after that period. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you.
Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty. Intel is not responsible for direct, special, incidental, or consequential damages resulting from any breach of warranty under another legal theory including, but not limited to, lost profits, downtime, goodwill, damage to or replacement of equipment and property, and any costs of recovering, reprogramming, or reproducing any program or data stored in or used with a system containing this product. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights that vary from jurisdiction to jurisdiction.
Any and all disputes arising under or related to this Limited Warranty shall be adjudicated in the following forums and governed by the following laws: for the United States of America, Canada, North America, and South America, the forum shall be Santa Clara, California, USA, and the applicable law shall be that of the State of California, USA; for the Asia Pacific region, the forum shall be Singapore and the applicable law shall be that of Singapore; for Europe and the rest of the world, the forum shall be London and the applicable law shall be that of the United Kingdom.
In the event of any conflict between the English language version and any other translated version(s) of this Limited Warranty, the English language version shall control.

To obtain warranty service for this Product, you may contact Intel or your authorized distributor.
Any replacement Product is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period.
If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative. See “Getting Help” for telephone numbers.
Before returning any product, call your authorized dealer/distribution authority.



English
This document applies to Intel® server boards, Intel® server chassis (pedestal and rack- mount) and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or maintaining your Intel® server product.
In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
Your server should be integrated and serviced only by technically qualified persons.
You must adhere to the guidelines in this guide and the assembly instructions in your server manuals to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL Listing and other regulatory approvals of the product, and may result in noncompliance with product regulations in the region(s) in which the product is sold.
To avoid personal injury or property damage, before you begin installing the product, read, observe, and adhere to all of the following safety instructions and information. The following safety symbols may be used throughout the documentation and may be marked on the product and / or the product packaging.
Indicates potential hazard if indicated information is ignored.
Indicates shock hazards that result in serious injury or death if safety instructions are not followed.
Indicates hot components or surfaces.

Indicates do not touch fan blades, may result in injury.
Indicates to unplug all AC power cord(s) to disconnect AC power
This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than an ITE application, may require further evaluation.
The system is designed to operate in a typical office environment. Choose a site that is:
Reduce the risk of personal injury or equipment damage:
Please recycle battery

off the system AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are unplugged. Make sure the AC power cord(s) is/are unplugged before you open the chassis, or add or remove any non hot-plug components.
Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply.
Some power supplies in Intel® servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.
The power supply in this product contains no user-serviceable parts. Do not open the power supply. Hazardous voltage, current and energy levels are present inside the power supply. Return to manufacturer for servicing.
When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing it from the server.
To avoid risk of electric shock, turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it.
If an AC power cord was not provided with your product, purchase one that is approved for use in your country.
product as follows:

whenever accessing the inside of the product:
Unless you are adding or removing a hot-plug component, allow the system to cool before opening the covers. To avoid the possibility of coming into contact with hot component(s) during a hot-plug installation, be careful when removing or installing the hot-plug component(s).
over the fan, do not operate the system without the fan guard in place.
The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions.
Install equipment in the rack from the bottom up, with the heaviest equipment at the bottom of the rack.
Extend only one piece of equipment from the rack at a time.
You are responsible for installing a main power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the server(s).
To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it.

all procedures at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground -- any unpainted metal surface -- on your server when handling parts.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
battery, use only the battery recommended by the equipment manufacturer.
Dispose of batteries according to local ordinances and regulations.
Do not attempt to recharge a battery.
Do not attempt to disassemble, puncture, or otherwise damage a battery.
For proper cooling and airflow, operate the system only with the chassis covers installed. Operating the system without the covers in place can damage system parts. To install the covers:

Compliance Information
Product Regulatory Compliance
guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products/components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.
To help ensure EMC compliance with your local regional rules and regulations, before computer integration, make sure that the server system, power supply, and other modules have passed EMC testing using a server board with a microprocessor from the same family (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.
This is an FCC Class A device. Integration of it into a Class B system does not result in a Class B device.
This server system product, when correctly integrated per this guide, complies with the following safety and electromagnetic compatibility (EMC) regulations.
This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as: medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment, etc.), other than an ITE application, may require further evaluation.
The server system complies with the following product safety requirements:

This server system has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.

This Intel® server system product is provided with the following regulatory marks.
Table 8. Product Regulatory Compliance Markings
Regulatory Compliance Region Marking
cULus Listing Marks USA/Canada
IRAM Mark Argentina · GS Mark Germany

Table 8. Product Regulatory Compliance Markings
Regulatory Compliance Region Marking
FCC Marking (Class A) USA

EMC Marking (Class A) Canada
C-Tick Mark Australia / New Zealand
VCCI Marking (Class A) Japan

BSMI Certification Number & Class A Warning

GOST R Marking Russia
RRL MIC Mark Korea
China Compulsory Certification Mark
CE Mark Europe · Taiwan · China

Table 8. Product Regulatory Compliance Markings
Regulatory Compliance Region Marking
Recycling Other than China
CA. Lithium Perchlorate insert
Perchlorate Material - Special handling may apply. See www.dtsc.ca.gov/hazardouswaste/ perchlorate
This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material.
Country of Origin Made in XXXX
WEEE Mark · RoHS China · Recycling Mark China

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product.
Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC Class A or B limits may be attached to this computer product. Operation with noncompliant peripherals is likely to result in interference to radio and TV reception.
All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception.

Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Apparelis Numériques", NMB-003 édictee par le Ministre Canadian des Communications.
English translation of the notice above:
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled: "Digital Apparatus," ICES-003 of the Canadian Department of Communications.
This product has been tested in accordance to, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance.

English translation of the preceding notice:
This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.

The BSMI Certification Marking and EMC warning is located on the outside rear area of the product.

Following is the RRL certification information for Korea.

English translation of the notice above:
The CCC Certification Marking and EMC warning is located on the outside rear area of the product.
此为 A 级产品,在生活环境中,该产品可能会造成无 线电干扰。在这种情况下,可能需要用户对其干扰采 取可行的措施。
Regulated Specified Components
To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging or use of other components will void the UL listing and other product certifications and approvals.
Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder
If you do not have access to Intel's Web address, please contact your local Intel representative.

Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance. Due verification of random materials is required as a screening / audit to verify suppliers declarations. The server board complies with the following ecology regulatory requirements:
— Quantity limit of 0.1% by mass (1000 PPM) for Lead, Mercury, Hexavalent hromium, Polybrominated Biphenyls Diphenyl Ethers (PBB/PBDE)
— Quantity limit of 0.01% by mass (100 PPM) for Cadmium

Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back.
I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.
Invia la prima domanda: risponderanno altri possessori o il nostro team.