Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 1 of the Intel SR1520ML user manual
Pagina 1 · clicca per ingrandire
Pagina 1

A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products

Intel Order Number E17409-002

Intel® Server System SR1520ML User’s Guide i

Page 2 of the Intel SR1520ML user manual
Pagina 2 · clicca per ingrandire
Pagina 2

Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.

Intel server boards contain a number of high-density VLSI and power delivery components that need adequate airflow for cooling. Intel's own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.

Intel and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

* Other names and brands may be claimed as the property of others.

Copyright © 2007, Intel Corporation. All Rights Reserved

ii Intel® Server System SR1520ML User’s Guide

Disclaimer

Page 3 of the Intel SR1520ML user manual — Instrucciones de seguridad importantes
Pagina 3 · clicca per ingrandire
Pagina 3

Safety Information

Important Safety Instructions

Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/ motherboards/server/sb/cs-010770.htm.

Wichtige Sicherheitshinweise

Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der Intel® Server Deployment Toolkit 2.0 CD oder unter http://support.intel.com/support/motherboards/server/sb/cs-010770.htm

Consignes de sécurité

Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le Intel® Server Deployment Toolkit 2.0 CD ou bien rendez-vous sur le site http://support.intel.com/support/motherboards/server/sb/cs- 010770.htm.

Instrucciones de seguridad importantes

Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en el Intel® Server Deployment Toolkit 2.0 CD y/o en http:// support.intel.com/support/motherboards/server/sb/cs-010770.htm

Intel® Server System SR1520ML User’s Guide iii

Page 4 of the Intel SR1520ML user manual — Warnings
Pagina 4 · clicca per ingrandire
Pagina 4

重要安全指导

在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.htm 上的 Intel Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信息》)。

Warnings

Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.

System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components.

Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result.

Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts.

ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.

iv Intel® Server System SR1520ML User’s Guide

Page 5 of the Intel SR1520ML user manual — Warnings
Pagina 5 · clicca per ingrandire
Pagina 5

Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board.

Intel® Server System SR1520ML User’s Guide v

Page 6 of the Intel SR1520ML user manual — Warnings
Pagina 6 · clicca per ingrandire
Pagina 6

vi Intel® Server System SR1520ML User’s Guide

Page 7 of the Intel SR1520ML user manual — Table of contents
Pagina 7 · clicca per ingrandire
Pagina 7

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 8 of the Intel SR1520ML user manual — Table of contents
Pagina 8 · clicca per ingrandire
Pagina 8

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 9 of the Intel SR1520ML user manual — Table of contents
Pagina 9 · clicca per ingrandire
Pagina 9

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 10 of the Intel SR1520ML user manual — Table of contents
Pagina 10 · clicca per ingrandire
Pagina 10

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 11 of the Intel SR1520ML user manual — Table of contents
Pagina 11 · clicca per ingrandire
Pagina 11

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 12 of the Intel SR1520ML user manual — Warnings
Pagina 12 · clicca per ingrandire
Pagina 12

xii Intel® Server System SR1520ML User’s Guide

Page 13 of the Intel SR1520ML user manual — Table of contents
Pagina 13 · clicca per ingrandire
Pagina 13

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 14 of the Intel SR1520ML user manual — Warnings
Pagina 14 · clicca per ingrandire
Pagina 14

xiv Intel® Server System SR1520ML User’s Guide

Page 15 of the Intel SR1520ML user manual — Table of contents
Pagina 15 · clicca per ingrandire
Pagina 15

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 16 of the Intel SR1520ML user manual — Table of contents
Pagina 16 · clicca per ingrandire
Pagina 16

Table of contents

Safety Informationp.3Important Safety Instructionsp.3Wichtige Sicherheitshinweisep.3Consignes de sécuritép.3Instrucciones de seguridad importantesp.3Warningsp.4Prefacep.17About this Manualp.17Manual Organizationp.17Product Contentsp.18Server System Referencesp.191 Server System Featuresp.21External Component Identificationp.23System Front Panelp.23System Rearp.26Peripheral Devicesp.27Internal Componentsp.28Server Board Connectorsp.28Configuration Jumpersp.30SATA RAID Supportp.31Rack and Cabinet Mountingp.31Hardware Requirementsp.31Processorp.32Memoryp.322 Hardware Installations and Upgradesp.33Before You Beginp.33Tools and Supplies Neededp.33System Referencesp.33Removing and Installing the Server Coverp.34Removing the Server System Coverp.34Installing the Server System Coverp.35Installing and Removing a Hard Drivep.35Installing a Hard Drivep.36Removing a Hard Drivep.38Installing an Intel® Z-U130 Value Solid State Drivep.40Installing and Removing the PCI Riser Assemblyp.41Removing the PCI Riser Assemblyp.41Installing the PCI Riser Assemblyp.42Removing and Installing the PCI Riser Cardp.44Removing the PCI Riser Cardp.44Installing a PCI Riser Cardp.45Installing and Removing a PCI Add-in Cardp.46Installing a PCI Add-in Cardp.46Removing a PCI Add-in Cardp.47Removing and Installing the Processor Air Ductp.48Removing the Processor Air Ductp.48Installing the Processor Air Ductp.49Installing and Removing Memoryp.49Memory Population Rulesp.50Installing DIMMsp.50Removing DIMMsp.52Replacing the Processorp.53Removing the Heat Sink and Processorp.53Installing the Processorp.55Installing the Heat Sinkp.56Replacing the Power Supplyp.57Replacing the Fansp.60Replacing a Blower Fanp.61Replacing a Memory Cooling Fanp.64Replacing a Server Boardp.66Removing the Server Boardp.66Installing the Server Boardp.68Replacing the Front Panel Boardp.70Replacing the CMOS Batteryp.72Installing and Removing the Rack Handlesp.75Installing the Rack Handlesp.75Removing the Rack Handlesp.763 Server Utilitiesp.77Using the BIOS Setup Utilityp.77Starting Setupp.77If You Cannot Access Setupp.77Setup Menusp.77Upgrading the BIOSp.79Preparing for the Upgradep.79Recording the Current BIOS Settingsp.79Obtaining the Upgradep.80Upgrading the BIOSp.80Recovering the BIOSp.80Clearing the Passwordp.82Performing an iBMC Force Updatep.84Using the iBMC Boot Block Write Protect Jumper (J1A4)p.86Appendix A: Technical Referencep.87Cable Routingp.87Power Cable Routingp.88Data Cable Routingp.89600 W Power Supply Input Voltagesp.90600 W Power Supply Output Voltagesp.90System Environmental Specificationsp.91Appendix B: Installation/Assembly Safety Instructionsp.93Englishp.93Appendix C: Troubleshootingp.95Resetting the Systemp.95Problems following Initial System Installationp.96First Steps Checklistp.96Hardware Diagnostic Testingp.96Verifying Proper Operation of Key System Lightsp.97Confirming Loading of the Operating Systemp.97Specific Problems and Corrective Actionsp.97Power Light Does Not Lightp.98No Characters Appear on Screenp.98Characters Are Distorted or Incorrectp.99System Cooling Fans Do Not Rotate Properlyp.99Drive Activity Light Does Not Lightp.100CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Lightp.100Cannot Connect to a Serverp.100Problems with Networkp.101The server hangs when the drivers are loadedp.101Diagnostics pass but the connection failsp.101The add-in adapter stopped working without apparent causep.101System Boots when Installing PCI Cardp.101Problems with Newly Installed Application Softwarep.102Problems with Application Software that Ran Correctly Earlierp.102Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)p.103Hard Drive(s) are not Recognizedp.103Bootable CD-ROM Disk Is Not Detectedp.103Appendix D: Getting Helpp.105World Wide Webp.105Telephonep.105U.S. and Canadap.105Europep.105In Asia-Pacific regionp.106Japanp.106Latin Americap.106Appendix E: Warrantyp.109Limited Warranty for Intel® Chassis Subassembly Productsp.109Appendix F: Safety Informationp.113Englishp.113Server Safety Informationp.113Safety Warnings and Cautionsp.113Intended Application Usesp.114Site Selectionp.114Equipment Handling Practicesp.114Power and Electrical Warningsp.115Power Cord Warningsp.115System Access Warningsp.116Rack Mount Warningsp.116Electrostatic Discharge (ESD)p.117Other Hazardsp.117Battery Replacementp.117Cooling and Airflowp.117Laser Peripherals or Devicesp.117Appendix G: Regulatory and Compliance Informationp.118Product Regulatory Compliancep.118Product Safety Compliancep.118Intended Applicationp.118Product Safety Compliancep.118Product EMC Compliance - Class A Compliancep.119Certifications / Registrations / Declarationsp.120Product Regulatory Compliance Markingsp.120Electromagnetic Compatibility Noticesp.123FCC Verification Statement (USA)p.123Industry Canada (ICES-003)p.124Europe (CE Declaration of Conformity)p.124VCCI (Japan)p.124BSMI (Taiwan)p.124Korean Compliance (RRL)p.125CNCA (CCC-China)p.125Regulated Specified Componentsp.125Product Ecology Requirementsp.126End-of-Life / Product Recyclingp.127
Page 17 of the Intel SR1520ML user manual — Manual Organization
Pagina 17 · clicca per ingrandire
Pagina 17

Preface

About this Manual

Thank you for purchasing and using the Intel® Server System SR1520ML.

This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add and replace components on the server system. For the latest version of this manual, see http:// support.intel.com/support/motherboards/server/X38ML/

Manual Organization

Chapter 1 provides an overview of the server system. In this chapter, you will find a list of the server system features, illustrations of the product, and product diagrams to help you identify components and their locations.

Chapter 2 provides instructions on adding and replacing components. Use this chapter for step-by-step instructions and diagrams for installing or replacing components such as the fans, power supply, drives, and other components.

Chapter 3 provides instructions on using the utilities that are shipped with the board or that may be required to update the system. This includes how to navigate through the BIOS Setup screens, how to perform a BIOS update, and how to reset the password or CMOS. Information about the specific BIOS settings and screens is available in the Technical Product Specifications for the server board and chassis. See Table 1 on page xix for a link to the Technical Product Specifications.

At the back of this manual, you will find technical specifications, troubleshooting tips, regulatory information, complete safety information, “getting help” information, and the warranty.

Intel® Server System SR1520ML User’s Guide xvii

Page 18 of the Intel SR1520ML user manual — Product Contents
Pagina 18 · clicca per ingrandire
Pagina 18

Product Contents

Your Intel® Server System SR1520ML ships with the following items.

  • Two Intel ® Server Boards X38ML installed in the server chassis
  • One 600-watt power supply module, installed in the server chassis
  • One power cable to connect to AC power (North America only)
  • Four cooling fans, with attached cables, installed in the server system:

— Two memory cooling fans

— Two system blower fans

  • Two passive heat sinks, in the server system product box
  • Two hard drive brackets, in the server system product box
  • Two PCI Express* x16 risers, installed in the server system
  • Two processor / memory air ducts
  • Rack handles, in the server system product box
  • One front control panel board with front panel controls for two server boards, installed in the server system
  • One basic slide rail kit, in a separate box
  • Cables:

— Two SATA cables, installed in the server system

— Two front panel / Z-U130 USB Y-cables, installed in the server system

— One front panel Y-cable, installed in the server system

  • Intel ® Server Deployment Toolkit 2.0 CD that contains documentation, drivers, and utilities
  • Intel ® System Management Software 2.0 CD set. A two-CD set

xviii Intel® Server System SR1520ML User’s Guide

Page 19 of the Intel SR1520ML user manual — Server System References
Pagina 19 · clicca per ingrandire
Pagina 19

Server System References

If you need more information about this product or information about the accessories that can be used with this server chassis, use the following resources.

Table 1. Server System References

For this Information or

Software Use this Document or Software

Technical information about the server chassis, including sub-system overviews and mechanical drawings

Intel® Server System SR1520MLTechnical Product Specification

At http://support.intel.com/support/motherboards/server/X38ML/

Technical information about the server board, including board layout, connector pin-outs, timing information, mechanical drawings and LED information

Intel® Server Board X38ML Technical Product Specification

At http://support.intel.com/support/motherboards/server/X38ML

Technical information about the server system, including connector pin- outs, timing information, mechanical drawings and LED information

Intel® Server System SR1520ML Technical Product Specification

At http://support.intel.com/support/motherboards/server/X38ML/

If you just received this product and need to install it

Intel® Server System SR1520ML Quick Start User's Guide

In the product box

Accessories or other Intel server products

Spares and Configuration Guide

Available from your Intel field representative or on the Server Configurator Tool at http://indigo.intel.com/serverconfiguratortool/ default.aspx

Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product

Tested Hardware and Operating Systems List

At http://support.intel.com/support/motherboards/server/X38ML/

Processor and DIMMs that have been tested with this produc

See http://support.intel.com/support/motherboards/server/X38ML/

For drivers Search for the word “driver” (for an extensive list of available drivers)

Search for “operating system driver” (for operating system drivers)

For firmware and BIOS updates, or for BIOS recovery

Intel® Server System SR1520ML User’s Guide xix

Firmware Updates

Page 20 of the Intel SR1520ML user manual — Server System References
Pagina 20 · clicca per ingrandire
Pagina 20

Table 1. Server System References

For this Information or

Software Use this Document or Software

For software to manage your Intel® server

Intel® System Management Software Software 2.0

At http://support.intel.com/support/motherboards/server/X38ML/

To make sure your system falls within the allowed power budget

Search for the phrase “Power Budget Tool”

At http://support.intel.com/support/motherboards/server/X38ML/

For diagnostics test software

Search for the word “Diagnostics”

xx Intel® Server System SR1520ML User’s Guide

Page 21 of the Intel SR1520ML user manual — 1 Server System Features
Pagina 21 · clicca per ingrandire
Pagina 21

1 Server System Features

This chapter briefly describes the main features of the server system. It provides product illustrations, a list of the server system features, and diagrams that show the location of important components and connections.

Intel SR1520ML — 1 Server System Features diagram (page 21)
Fig. 1 · 1 Server System Features

Figure 1. Intel® Server System SR1520ML

The Intel® Server System SR1520ML ships with two Intel® Server Boards X38ML installed in it. Each server board operates as a fully functioning server system with it’s own control panel, BIOS setup configuration, processor, memory, drives, add-in card, keyboard/mouse, and video monitor. These items are not shared by the two server boards. The two server boards share the chassis and power supply.

Since the server boards function independently, the processor and DIMM rules apply to each board independently. The two server boards do not need to use identical processors or DIMMs.

Page 22 of the Intel SR1520ML user manual — 1 Server System Features
Pagina 22 · clicca per ingrandire
Pagina 22

Table 2 summarizes the features of the server system.

Table 2. Feature Summary

  • Dimensions
  • 1.67 inches high (42.42 mm)
  • 16.93 inches wide (430.02 mm)
  • 20 inches deep (508.00 mm)

Server board Intel® Server Board X38ML. Two per system.

Processors Processor and Front Side Bus (FSB) support

  • The system supports one processor on each server board. For supported Intel processors, see <a href="http://support.intel.com/" rel="nofollow noopener" target="_blank">http://support.intel.com/</a> support/motherboards/server/X38ML
  • Supports 800 / 1066 / 1333 MHz FSB
  • Memory
  • Four DIMM sockets per server board supporting stacked DDR2 667 / 800 MHz unbuffered ECC memory or non-ECC memory
  • Each server board has two memory channels with two DIMM sockets per channel
  • Support for up to 8 GB of total system memory on each server board

Chipset Intel® X38 chipset on each server board, consisting of:

  • Intel ® X38 Memory Controller Hub (MCH)
  • Intel ® I/O Controller Hub (ICH9R)

Peripheral Interfaces External connections on each server board:

  • DB9 Serial A port
  • Two RJ45 NIC connectors for 10 / 100 / 1000 Mb connections
  • Two USB 2.0 ports
  • VGA header for video output Internal connections on each server board:
  • One USB port header, which supports two USB 2.0 ports
  • One DH10 Serial B header
  • Four Serial ATA connectors with embedded RAID 0/1/10 support

Video Each server board has an on-board video controller with 32 MB DDR2 667 video memory

LAN Two Intel® 10 / 100 / 1000 82573E Gigabit Ethernet controllers on each server board

Expansion capabilities One low-profile PCI Express* riser card for each server board. Each supports one low-profile x1, x4, x8, or x16 adapter.

  • Hard drives
  • Support for up to two 2.5-inch drives. SATA (3.0 Gb/s) support
  • Support for two Intel ® Z-U130 Value Solid State Drives

Feature Description

Page 23 of the Intel SR1520ML user manual — System Front Panel
Pagina 23 · clicca per ingrandire
Pagina 23

Table 2. Feature Summary

Control panel Each server board has a control panel. Each control panel includes:

  • One USB port
  • Power / sleep button
  • Reset button
  • Power / sleep LED
  • Status LED
  • Hard drive activity LED
  • NIC1 activity LED
  • NIC2 activity LED

Power supply One 600-watt power supply module

  • Fans
  • Two memory cooling fans. Each server board controls one fan.
  • Two system blower fans. Each server board controls one fan.
  • USB
  • Each server board has two USB ports on the back panel
  • Each server board has one internal USB header, which supports two USB ports

System management Intel® System Management 2.0 Software

External Component Identification

This section helps you identify the components of your server system. If you are near the system, you can also use the quick reference label on the inside of the chassis cover to assist in identifying components.

System Front Panel

Each server board has its own control panel at the front of the server system. Each control panel includes the following buttons and LEDs.

Feature Description

Page 24 of the Intel SR1520ML user manual — External Component Identification
Pagina 24 · clicca per ingrandire
Pagina 24
Intel SR1520ML — External Component Identification diagram (page 24)
Fig. 2 · External Component Identification

A USB connector 2.0 port, 4-pin connectors

Front Panel Buttons and LED Indicators

Intel SR1520ML — External Component Identification diagram (page 24)
Fig. 3 · External Component Identification

Press to turn the system power on or off

C Power / sleep LED Green LED for system power status

Item Feature Description · Front Panel Connector

Page 25 of the Intel SR1520ML user manual — External Component Identification
Pagina 25 · clicca per ingrandire
Pagina 25

D System status / fault LED

Green / amber LED for system status.

LED Statte System State

Off System not ready

Green on System ready, no alarm

Green blink System ready but degraded by processor or DIMM error

Amber blink Non critical failure, such as non-critical power or voltabe error

Amber on Critical alarm. Critical power module failure, critical fan failure, power supply, voltage or thermal fault

E LAN1, LAN 2 Status LEDs

Green LEDs that show the status of each LAN port

LED State LAN State

On LAN link / no access

F Hard drive activity LED

Green LED that indicates hard drive activity

LED State Drive State

Green blink Drive is active

Off Drive is not active

G System reset button Press to reset the system

Figure 2. Front Controls and LEDs

Item Feature Description · Off Idle · Blinking Active

Page 26 of the Intel SR1520ML user manual — System Rear
Pagina 26 · clicca per ingrandire
Pagina 26

System Rear

Except for the shared AC power supply, each server board has its own back panel connectors.

Intel SR1520ML — System Rear diagram (page 26)
Fig. 4 · System Rear
Intel SR1520ML — System Rear diagram (page 26)
Fig. 5 · System Rear

B. PCI Express* add-in card slot location (one for each server board)

F. NIC 2 (10 / 100 / 1000 Mb) (one for each server board)

C. NIC 1 (10 / 100 / 1000 Mb) (one for each server board)

G. USB ports 0-1 (one sets of two ports for each server board)

Figure 3. Back Panel Connectors

The LEDs at the right and left of each NIC provide the following information.

Table 3. NIC LED Descriptions

Intel SR1520ML — System Rear diagram (page 26)
Fig. 6 · System Rear

Right Off 10 Mbps connection (if left LED is on or blinking)

Page 27 of the Intel SR1520ML user manual — Peripheral Devices
Pagina 27 · clicca per ingrandire
Pagina 27

Peripheral Devices

The server system provides locations for installing up to two fixed 2.5-inch SATA hard drives and up to two Intel® Z-U130 Value Solid State Drive (Intel® VSSD). Each server board controls one of each of these drives. No optical or floppy drive bays are available, but these devices are supported through an external USB connection. The drives must be purchased separately. The following figure shows the available options.

Intel SR1520ML — Peripheral Devices diagram (page 27)
Fig. 7 · Peripheral Devices

A. Two 2.5-inch hard drive bays, stacked on top of each other

B. Two Intel® Z-U130 Value Solid State Drive bays

Figure 4. Optional Peripherals

For instructions on installing a hard drive, see “Installing and Removing a Hard Drive” on page 15.

For instructions on installing the Intel® Z-U130 Value Solid State Drive, see the document titled Intel® Z-U130 Value Solid State Drive Mounting Kit Installation Guide for Intel® Server Systems.

maximum ambient temperature of 45oC.

See “Server System References” on page xix for an Internet link to a list of supported hardware.

Page 28 of the Intel SR1520ML user manual — Server Board Connectors
Pagina 28 · clicca per ingrandire
Pagina 28

Internal Components

Intel SR1520ML — Internal Components diagram (page 28)
Fig. 8 · Internal Components
Intel SR1520ML — Internal Components diagram (page 28)
Fig. 9 · Internal Components

B. Processor and memory air duct (two) F. Hard drive bracket (one bracket for two 2.5-inch drives)

C. Processor and heat sink (two) G. Front control panel (two)

D. PCI add-in card bracket (two) H. System blower fans (two)

Figure 5. System Components

Server Board Connectors

The two Intel® Server Boards X38ML have the same connectors / components.

Page 29 of the Intel SR1520ML user manual — Internal Components
Pagina 29 · clicca per ingrandire
Pagina 29
Intel SR1520ML — Internal Components diagram (page 29)
Fig. 10 · Internal Components
Intel SR1520ML — Internal Components diagram (page 29)
Fig. 11 · Internal Components

A. NIC1 RJ45 connector (top) I. Processor socket Q. DIMM socket B1

B. USB port 0 (bottom) USB port 1 (center)

C. NIC2 RJ45 connector K. System fan 3 S. SATA port 0

D. CMOS battery L. System fan 2 T. SATA port 1

E. Serial A DB9 connector M. System fan 1 U. SATA port 2

F. VGA connector N. Main power connector V. SATA port 3

G. POST LEDs O. DIMM socket A1 W. USB header for USB 2 and 3

H. PCI Express* x16 riser slot P. DIMM socket A2 X. Chassis intrusion header

Figure 6. Server Board Connector Locations

Page 30 of the Intel SR1520ML user manual — A
Pagina 30 · clicca per ingrandire
Pagina 30

Configuration Jumpers

The two Intel® Server Boards X38ML have the same jumpers.

A

D

B

E

Callout Location Jumper Name Jumper Purpose

A J1A4 iBMC Boot Block Write Protect

When pins 2-3 are jumpered, the iBMC boot block is write enabled. When pins 1-2 are jumpered, the iBMC boot block is write protected. Pins 1-2 should be jumpered for normal operation.

B J1A2 BIOS Recovery Mode

When pins 2-3 are jumpered, the BIOS will be recovered on the next boot. Pins 1-2 should be jumpered for normal operation.

C J1A3 CMOS Clear When pins 2-3 are jumpered, the CMOS settings will be cleared on the next boot. Pins 1-2 should be jumpered for normal operation.

D J3A1 iBMC Force Update Mode

When pins 2-3 are jumpered, the iBMC firmware will be updated on the next boot. Pins 1-2 should be jumpered for normal operation.

E J6B1 Password Clear

When pins 2-3 are jumpered, the administrator and user passwords will be reset on the next boot. Pins 1-2 should be jumpered for normal operation.

Figure 7. Configuration Jumpers

Page 31 of the Intel SR1520ML user manual — Hardware Requirements
Pagina 31 · clicca per ingrandire
Pagina 31

SATA RAID Support

The Intel® Server System SR1520ML provides SATA (3.0 Gb/s) support.The embedded SATA controller embedded supports both 1.5 and 3.0 Gbps data transfer rates. The Intel® RAID Technology solution, available with the ICH9R, offers data striping for higher performance (RAID Level 0) and mirroring for higher reliability (RAID Level 1).

The BIOS Setup utility provides multiple drive configuration options on the Advanced | ATA Controller setup page, some of which affect the ability to configure RAID. The “Onboard SATA Controller” option is enabled by default. When this option is enabled, the “Configure SATA as” option can be set to either IDE, AHCI, or RAID.

For assistance in navigating through the F2 BIOS Setup utility, see the Intel® Server Board X38ML Technical Product Specification.

For information about setting up RAID, see the RAID Software Guide that is included on the Intel® Server Deployment Toolkit 2.0 CD.

Rack and Cabinet Mounting

The server system can be mounted into a 19-inch wide by up to a 30-inch deep server cabinet. The system ships with a basic slide rail kit and supports optionsl fixed-mount and tool-less slide rail kits:

  • The basic slide rail kit mounts the system into a standard 19-inch wide by up to 30inch deep EIA-310D-compatible server cabinet. The product order code is AXXBASICRAIL. This kit is included with your server system.
  • A fixed mount relay rack / cabinet mount kit can be configured to mount the system into either a 2-post or 4-post rack cabinet. The product order code is AXXBRACKETS. This kit is included with your server system.
  • A tool-less full-extracting slide rail kit supports an optional cable management arm. The product order code is AXXRACKCARM. This is an optional accessory that must be ordered separately.

Hardware Requirements

To avoid integration difficulties and possible board damage, your system must meet the requirements outlined below. For a list of qualified components, see the links under "Server System References."

Page 32 of the Intel SR1520ML user manual — Memory
Pagina 32 · clicca per ingrandire
Pagina 32

Processor

Each server board must have one processor installed. Each board can use a different processor. For a list of supported processors, see http://support.intel/com/support/ motherboards/server/X38ML.

Memory

Each server supports four DDR2 667 / 800 MHz unbuffered ECC DIMMs. The maximum memory capacity is 2 GB unbuffered, 1 Gbit DDR2 memory. The minimum is one 256- MB DIMM. The four slots are partitioned into Channel A and Channel B. Channel A consists of DIMM A1 and DIMM A2. Channel Bconsists of DIMM B1 and DIMM B2. DIMM A1 is the closest to the MCH.

DIMMs must meet the following requirements:

  • If dual-channel operation is desired, Channel A and Channel B must be populated identically (i.e., same capacity)
  • Use DDR2 667 / 800 only.
  • The speed used on all the channels is the slowest DIMM in the system
  • Use ECC or non-ECC DIMMs
  • You can mix different memory technologies (size and density)
  • For single-channel mode, either channel may be used and DIMM sockets within the same channel can be populated in any order
  • For dual-channel interleaved mode, DIMM sockets may be populated in any order as long as the total memory in each channel is the same.
  • For dual-channel asymmetric mode, DIMM sockets may be populated in any order.

For a complete list of supported memory DIMMs, see http://support.intel/com/support/ motherboards/server/X38ML.

Page 33 of the Intel SR1520ML user manual — System References
Pagina 33 · clicca per ingrandire
Pagina 33

2 Hardware Installations and Upgrades

removing or installing any component in this server system, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button(s), and unplug the AC power cord from the system or wall outlet.

Before You Begin

Before working with your server product, pay close attention to the “Safety Information” on page iii.

Tools and Supplies Needed

  • Phillips* (cross head) screwdriver, #1 bit and #2 bit
  • Antistatic wrist strap and conductive foam pad (recommended)

System References

All references to left, right, front, top, and bottom assume the reader is facing the front of the server system as it would be positioned for normal operation.

Page 34 of the Intel SR1520ML user manual — Removing the Server System Cover
Pagina 34 · clicca per ingrandire
Pagina 34

Removing and Installing the Server Cover

Removing the Server System Cover

The server system must be operated with the cover in place to ensure proper cooling. You will need to remove the cover to add or replace components inside of the server.

None of the internal components are hot-swappable. Before removing the server system cover, power down the server and unplug all peripheral devices and the AC power cable.

system from sliding on your work surface.

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Turn off all peripheral devices connected to the server. Turn off the server.
3. Disconnect the AC power cord.
4. Remove the screw from the rear of the system. See letter “A” in the figure below.
5. Remove the two screws from the top of the system, at the front edge. See letter “B” in the figure.
6. Push rearward on the top cover to slide the cover about 3/4 inch, until it stops, then lift up on the cover to remove it. See letter “C”.
Intel SR1520ML — Removing the Server System Cover diagram (page 34)
Fig. 12 · Removing the Server System Cover

Figure 8. Removing the Server System Cover

Page 35 of the Intel SR1520ML user manual — Installing and Removing a Hard Drive
Pagina 35 · clicca per ingrandire
Pagina 35

Installing the Server System Cover

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Place the cover over the server system so that the side edges of the cover sit just outside of the server system sidewalls. Slide the cover forward. See letter “A” in the figure below.
3. Insert the larger screw at the rear of the system. See letter “B” in the figure.
4. Insert the two small screws on the top surface of the cover, near the front edge. See letter “C”.
Intel SR1520ML — Installing the Server System Cover diagram (page 35)
Fig. 13 · Installing the Server System Cover

Figure 9. Installing the Server System Cover

5. Reconnect all peripheral devices and the AC power cord.

Installing and Removing a Hard Drive

must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

One SATA drive can be installed for each server board (two drives total). Both drive bays are at the right side of the chassis.

Page 36 of the Intel SR1520ML user manual — Installing a Hard Drive
Pagina 36 · clicca per ingrandire
Pagina 36

page xix for an Internet link to a list of supported hardware.

Installing a Hard Drive

instructions first. Return to these steps when directed.

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server. Unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the three screws that hold the hard drive bracket to the system. See letter “A” in the figure below. For easiest access to the screws on the right side of the hard drive bracket, lift the power supply from the system.
5. Lift the drive carrier from the system. See letter “B” in the figure.
Intel SR1520ML — Installing a Hard Drive diagram (page 36)
Fig. 14 · Installing a Hard Drive

Figure 10. Removing Drive Carrier from the Server System

Page 37 of the Intel SR1520ML user manual — Installing a Hard Drive
Pagina 37 · clicca per ingrandire
Pagina 37
6. Slide the drive into the carrier, connector side last. See letter “A” in the following figure. If you are installing a drive for each server board, note which drive is on bottom and which is on top to ensure you connect the cables correctly later.
7. Use the four screws provided to attach the drive to the carrier, two screws on each side of the carrier. See letter “B” in the figure
Intel SR1520ML — Installing a Hard Drive diagram (page 37)
Fig. 15 · Installing a Hard Drive

assembly into the server.

8. Connect one blue SATA cable between each drive and the SATA_0 port on each server board if you installed two drives. Be sure to note which drive is connected to which server board.
9. Connect the power cables to the drive(s):

— Connect the power cable labeled “P4” to the bottom drive.

— Connect the power cable labeled “P3” to the top drive.

10. Set the drive assembly into place in the chassis. See letter “A” in the figure below.
11. Attach the drive assembly to the chassis with the three screws that you removed earlier. See letter “B” in the figure below.
Page 38 of the Intel SR1520ML user manual — Removing a Hard Drive
Pagina 38 · clicca per ingrandire
Pagina 38
Intel SR1520ML — Removing a Hard Drive diagram (page 38)
Fig. 16 · Removing a Hard Drive

Figure 11. Installing Drive Assembly

12. If you lifted out the power supply to access the drive bracket screws, set the power supply back into place.
13. Install the server system cover. For instructions, see “Installing the Server System Cover” .

Removing a Hard Drive

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the three screws that hold the hard drive bracket to the chassis. For easiest access to the two screws on the right side, lift the power supply from the system. See letter “A” in the figure below.
5. Lift the drive carrier from the chassis. See letter “B” in the figure.
Page 39 of the Intel SR1520ML user manual — Removing a Hard Drive
Pagina 39 · clicca per ingrandire
Pagina 39
Intel SR1520ML — Removing a Hard Drive diagram (page 39)
Fig. 17 · Removing a Hard Drive

Figure 12. Removing Drive Carrier

6. Disconnect the power and data cables from the drive.
7. Remove the four screws that attach the hard drive to the drive carrier. Lift the drive from the carrier. Store the drive in an anti-static bag.
8. If you are installing a new drive, skip the rest of these steps and instead see “Installing a Hard Drive” on page 16 . Begin with step 6.
9. Insert the screws that held the drive in the carrier into the screw locations on the carrier to store them for future use.
10. Set the drive assembly into place in the chassis. See letter “A” in the figure below.
11. Attach the drive assembly to the chassis with the three screws that you removed earlier. See letter “B” in the figure below.
Page 40 of the Intel SR1520ML user manual — Installing an Intel ® Z-U130 Value Solid State Drive
Pagina 40 · clicca per ingrandire
Pagina 40
Intel SR1520ML — Installing an Intel® Z-U130 Value Solid State Drive diagram (page 40)
Fig. 18 · Installing an Intel® Z-U130 Value Solid State Drive

Figure 13. Installing the Drive Carrier

12. If you lifted out the power supply to access the drive bracket screws, set the power supply back into place.
13. Install the server system cover. For instructions, see “Installing the Server System Cover” .

Installing an Intel ® Z-U130 Value Solid State Drive

you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Follow the instructions in the document titled Intel ® Z-U130 Value Solid State Drive Mounting Kit Installation Guide for Intel ® Server Systems .
Page 41 of the Intel SR1520ML user manual — Removing the PCI Riser Assembly
Pagina 41 · clicca per ingrandire
Pagina 41

cable is attached to the front panel board. The other cable is loose. This loose cable is for the Intel® VSSD.

5. Install the server system cover. For instructions, see “Installing the Server System Cover” .
6. Plug all peripheral devices and the AC power cable into the server.

Installing and Removing the PCI Riser Assembly

riser assembly, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Removing the PCI Riser Assembly

To remove the PCI riser assembly, use the following instructions.

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Disconnect any cables attached to any add-in cards.
5. Remove the screw from the riser asssembly bracket. See letter “A” in the following figure.
6. Lift up on the riser assembly to remove it. Use caution to gently ease the riser card from the add-in card slot so you do not damage the slot or the riser card. See letter “B” in the figure.
Page 42 of the Intel SR1520ML user manual — Installing the PCI Riser Assembly
Pagina 42 · clicca per ingrandire
Pagina 42
Intel SR1520ML — Installing the PCI Riser Assembly diagram (page 42)
Fig. 19 · Installing the PCI Riser Assembly

Figure 14. Removing PCI Riser Assembly

7. If you need to replace the PCI riser card, see “Removing and Installing the PCI Riser Card” on page 24 .
8. If you need to install or remove a PCI add-in card, see “Installing and Removing a PCI Add-in Card” on page 26 .
9. If you removed the PCI riser assembly as instructed in another procedure, continue with that procedure.

Installing the PCI Riser Assembly

If you are installing an add-in card, do so before installing the PCI riser assembly into your server system.

1. Lower the riser assembly into place over the add-in card slot. See letter “A” in the following figure, aligning the tabs on the riser assembly with the matching slot at the back of the server system, and aligning the riser card with the slot in the server board.
2. Press down uniformly until the riser card is seated on the server board.
3. Insert the screw into the riser asssembly bracket. See letter “B” in the figure.
Page 43 of the Intel SR1520ML user manual — Installing the PCI Riser Assembly
Pagina 43 · clicca per ingrandire
Pagina 43
Intel SR1520ML — Installing the PCI Riser Assembly diagram (page 43)
Fig. 20 · Installing the PCI Riser Assembly

Figure 15. Installing PCI Riser Assembly into the Server System

4. Install the server system cover. For instructions, see “Installing the Server System Cover” .
Page 44 of the Intel SR1520ML user manual — B
Pagina 44 · clicca per ingrandire
Pagina 44

Removing and Installing the PCI Riser Card

card, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Removing the PCI Riser Card

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Disconnect any cables attached to any add-in cards.
5. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 21 .
6. Remove the add-in card from the PCI riser connector if an add-in card is installed. For instructions, see “Removing a PCI Add-in Card” on page 27 .
7. Remove the two screws that attach the riser card to the riser assembly. See the following figure. Save these screws for later.

B

AF002533 A

Figure 16. Removing Riser Card from Riser Assembly

8. Install the replacement riser card. For instructions, see “Installing a PCI Riser Card” on page 25 .
9. Choose the appropriate action:

— Install an add-in card. For instructions, see “Installing a PCI Add-in Card” on page 26.

Page 45 of the Intel SR1520ML user manual — A
Pagina 45 · clicca per ingrandire
Pagina 45

— Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 22.

Installing a PCI Riser Card

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” .
4. Disconnect any cables attached to any add-in cards.
5. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 21 .
6. Remove any add-in cards from the PCI riser connector. For instructions, see “Removing a PCI Add-in Card” on page 27 .
7. Use two screws to attach the riser card to the riser assembly. See the figure below.

A

AF002650 B

Figure 17. Installing Riser Card onto Riser Assembly

8. Choose the appropriate action:

— Install a PCI add-in card if desired. For instructions, see “Installing a PCI Add- in Card” on page 26.

— Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 22.

Page 46 of the Intel SR1520ML user manual — Installing a PCI Add-in Card
Pagina 46 · clicca per ingrandire
Pagina 46

Installing and Removing a PCI Add-in Card

you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Installing a PCI Add-in Card

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 21 .
5. Remove the screw from the add-in card slot opening.
6. If a filler panel is installed over the opening at the rear of the riser assembly, remove it. Save the filler panel in case you later need to remove the add-in card.
7. Insert the add-in card into the socket in the riser assembly. Push the add-in card into place firmly until it seats in the riser card connector, but use caution so you do not twist or bend the card. See letter “A” in the figure.
8. Re-install the screw you removed in step 5. See letter “B” in the figure.
Intel SR1520ML — Installing a PCI Add-in Card diagram (page 46)
Fig. 21 · Installing a PCI Add-in Card

Figure 18. Installing an Add-In Card

Page 47 of the Intel SR1520ML user manual — Removing a PCI Add-in Card
Pagina 47 · clicca per ingrandire
Pagina 47
9. Connect any necessary cables to the add-in card. See your add-in card documentation for information.
10. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 22 .

Removing a PCI Add-in Card

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 21 .
5. Remove the screw at the rear of the riser assembly. See letter “A” in Figure 19 . Save this screw. You will use it later.
6. Pull the add-in card from the roser assembly socket. Use caution so you do not twist or bend the card. See letter “A” in the figure.
7. If you are not installing a replacement add-in card, install a filler panel over the opening at the rear of the riser assembly.
8. Re-install the screw you removed in step 5. See letter “B” in the figure.
Intel SR1520ML — Removing a PCI Add-in Card diagram (page 47)
Fig. 22 · Removing a PCI Add-in Card

Figure 19. Removing an Add-In Card

Page 48 of the Intel SR1520ML user manual — Removing the Processor Air Duct
Pagina 48 · clicca per ingrandire
Pagina 48
9. Install the PCI riser assembly into the server system. For instructions, see “Installing the PCI Riser Assembly” on page 22 .

Removing and Installing the Processor Air Duct

Always operate your server system with the processor air duct in place. The air duct is required for proper airflow within the server system.

Removing the Processor Air Duct

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” .
4. Lift the processor air duct from its location behind the two fans.
Intel SR1520ML — Removing the Processor Air Duct diagram (page 48)
Fig. 23 · Removing the Processor Air Duct

Figure 20. Removing the Processor Air Duct

Page 49 of the Intel SR1520ML user manual — Installing and Removing Memory
Pagina 49 · clicca per ingrandire
Pagina 49

Installing the Processor Air Duct

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Lower the air duct into place. Use caution so you do not pinch or disengage cables that may be near or under the air duct.
Intel SR1520ML — Installing the Processor Air Duct diagram (page 49)
Fig. 24 · Installing the Processor Air Duct

Figure 21. Installing the Processor Air Duct

5. Install the server system cover. For instructions, see “Installing the Server System Cover” .

Installing and Removing Memory

you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Page 50 of the Intel SR1520ML user manual — Installing DIMMs
Pagina 50 · clicca per ingrandire
Pagina 50

The silkscreen on the board for the DIMMs displays DIMMB2, DIMMB1, DIMMA2, DIMMA1 starting from the edge of the board. DIMMA1 is the socket closest to the processor socket. See “Memory” on page 12 for a discussion of the memory requirements and options. See “Server System References” on page xix for a link to the list of tested DIMMs.

Memory Population Rules

Each server board in the Intel® Server System SR1520ML provides four DIMM sockets across two banks. For each server board, Bank 1 consists of DIMM sockets A1 and B1. Bank 2 consists of DIMM sockets A2 and B2. For single-channel operation, either channel may be used and DIMM sockets within the same channel can be populated in any order. For dual-channel asymetric mode, DIMM sockets may be populated in any order.

DIMMs must meet the following requirements:

  • The minimum memory is one 256 MB DIMM in socket A1 on each server board. Socket A1 is the blue socket that is the closest to the senter of the server board. This provides single-channel mode for each server board,
  • Use only DIMMs with DDR2 DRAM technology.
  • Use only DDR2-667 and DDR2-800 stacked DIMM modules. The speed used on all channels is that of the slowest DIMM on the server board.

For dual-channel operation, the following conditions must be met:

  • Populate two identical DIMMs in sockets DIMMA1 and DIMM B1. These are the two blue sockets
  • Populate four identical DIMMs in each socket location.

For a complete list of supported memory DIMMs, see http://support.intel/com/support/ motherboards/server/X38ML.

Installing DIMMs

To install DIMMs, follow these steps:

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 28 .
5. Locate the DIMM sockets. See Figure 22 .
Page 51 of the Intel SR1520ML user manual — Memory Population Rules
Pagina 51 · clicca per ingrandire
Pagina 51
Intel SR1520ML — Memory Population Rules diagram (page 51)
Fig. 25 · Memory Population Rules

DIMM Socket B2 DIMM Socket B1 DIMM Socket A2 DIMM Socket A1

Figure 22. Installing Memory DIMMs

6. Make sure the clips at both ends of the DIMM socket(s) are pushed outward to the open position. See letter “A” in Figure 22 .
7. Holding the DIMM by the edges, remove it from its anti-static package.
8. Position the DIMM above the socket. Align the notch on the bottom edge of the DIMM with the key in the DIMM socket. See letter “B” in the figure.
9. Insert the bottom edge of the DIMM into the socket. See letter “C” in the figure.
10. When the DIMM correctly positioned, push down on the top edge of the DIMM until the retaining clips snap into place.
11. Make sure the clips are firmly in place. See letter “D” in the figure.
12. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 29 .
13. Install the server system cover. For instructions, see “Installing the Server System Cover” .
Page 52 of the Intel SR1520ML user manual — Removing DIMMs
Pagina 52 · clicca per ingrandire
Pagina 52

Removing DIMMs

To remove a DIMM, follow these steps:

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 28 .
5. Locate the DIMM sockets. See Figure 22 .
6. Gently spread the retaining clips at each end of the socket. See letter “A” in the following figure. The DIMM lifts from the socket. See letter “B” in the figure.
7. Holding the DIMM by the edges, lift it from the socket, and store it in an anti-static package.
8. Close the DIMM socket clips. See letter “C”.
Intel SR1520ML — Removing DIMMs diagram (page 52)
Fig. 26 · Removing DIMMs

DIMM Socket B2 DIMM Socket B1 DIMM Socket A2 DIMM Socket A1

Figure 23. Removing Memory DIMMs

Page 53 of the Intel SR1520ML user manual — Removing the Heat Sink and Processor
Pagina 53 · clicca per ingrandire
Pagina 53
9. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 29 .
10. Install the server system cover. For instructions, see “Installing the Server System Cover” .

Replacing the Processor

to replace your processor. If you are setting up this system for the first time, see the Quick Start User’s Guide that was included in the product box.

System References” on page xix for a link to the list of compatible processor(s).

the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. (2) Avoid moving around unnecessarily.

Removing the Heat Sink and Processor

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 28 .
5. Loosen the four captive screws on the corners of the heat sink.
6. Twist the heat sink slightly to break the seal between the heat sink and the processor.
7. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force the heat sink from the processor. Doing so could damage the processor.
8. Raise the processor socket handle completely. See the following figure.
Page 54 of the Intel SR1520ML user manual — Replacing the Processor
Pagina 54 · clicca per ingrandire
Pagina 54

Figure 24. Opening the Processor Socket Handle

9. Push the rear tab with your finger to slightly lift the front of the load plate. Raise the load plate completely. Raise the CPU load plate. See the following figure.
Intel SR1520ML — Replacing the Processor diagram (page 54)
Fig. 27 · Replacing the Processor

Figure 25. Opening the Load Plate

10. Lift the processor from the socket. See the following figure.
Page 55 of the Intel SR1520ML user manual — Installing the Processor
Pagina 55 · clicca per ingrandire
Pagina 55
Intel SR1520ML — Installing the Processor diagram (page 55)
Fig. 28 · Installing the Processor

Figure 26. Removing the Processor

11. Continue with the steps under “Installing the Processor” .

Installing the Processor

These steps assume you have just removed your heat sink and processor and your server system is powered down and unplugged. If this is not true, see “Removing the Heat Sink and Processor” on page 33 before following these steps.

1. Remove the processor from the packaging box and remove the protective shipping cover.
2. Orient the processor with the socket so the processor cutouts match the socket notches, then set the processor into place.
Page 56 of the Intel SR1520ML user manual — Installing the Heat Sink
Pagina 56 · clicca per ingrandire
Pagina 56
Intel SR1520ML — Installing the Heat Sink diagram (page 56)
Fig. 29 · Installing the Heat Sink

Figure 27. Installing the Processor

3. Lower the CPU load plate.
4. Lower the socket lever.
5. Install the heat sink. For instructions, see the following steps.

Installing the Heat Sink

Install the processor before installing the heat sink. For instructions, see “Installing the Processor” on page 35.

1. Remove the protective cover from the TIM on the underside of the heat sink. Do not touch the TIM.
2. Orient the heat sink over the processor as shown by Figure 28 . The fins must be positioned as shown to provide correct airflow through the system.
3. Set the heat sink over the processor, lining up the four captive screws with the four posts surrounding the processor.
4. Loosely screw in the captive screws on the heat sink corners in a diagonal manner as shown by the four circled numbers in the figure below. Do no fully tighten one screw before tightening another.
Page 57 of the Intel SR1520ML user manual — Replacing the Power Supply
Pagina 57 · clicca per ingrandire
Pagina 57
5. Gradually and equally tighten each captive screw in the same order until each is firmly tightened.
Intel SR1520ML — Replacing the Power Supply diagram (page 57)
Fig. 30 · Replacing the Power Supply

Figure 28. Installing the Heat Sink

6. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 29 .
7. Install the server system cover. For instructions, see “Installing the Server System Cover” .

Replacing the Power Supply

you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

The power supply can be replaced if it fails or if one of the fans that is integrated into it fails. To replace the power supply, use the following instructions.

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
Page 58 of the Intel SR1520ML user manual — Replacing the Power Supply
Pagina 58 · clicca per ingrandire
Pagina 58
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” .
4. Disconnect all power cables connected to the server board and peripherals. See Figure 29 :

— From each server board, disconnect the main power cable. This connector is labeled P1 for the board on the right, and P2 for the board on the left. See letters “A” and “B” in the following figure

— From each hard drive, disconnect the power cable. The connector to the top drive is labeled P3 and the connector to the bottom drive is labeled P4. See letters “C” and “D” in the figure. .

Intel SR1520ML — Replacing the Power Supply diagram (page 58)
Fig. 31 · Replacing the Power Supply

Figure 29. Disconnecting Power Cables

Page 59 of the Intel SR1520ML user manual — Replacing the Power Supply
Pagina 59 · clicca per ingrandire
Pagina 59
5. Push back on the tab for the cable harness to release the bundle of cables.
6. Lift the cable bundle from the harness.
7. Lift up on the power supply to remove it.
Intel SR1520ML — Replacing the Power Supply diagram (page 59)
Fig. 32 · Replacing the Power Supply
8. Slide the rear edge of the replacement power supply into place, lining up with the rear of the server system. See letter “A” in the following figure.
9. Set the front of the power supply down, ensuring it sits behind the metal tab in the bottom of the system. See letter “B” in the figure.
10. Push the bundle of cables into place between the drive carriers and the wall of the system.
11. Insert the cable bundle into the cable harness and then close the harness over the cables.
Page 60 of the Intel SR1520ML user manual — Replacing the Fans
Pagina 60 · clicca per ingrandire
Pagina 60
Intel SR1520ML — Replacing the Fans diagram (page 60)
Fig. 33 · Replacing the Fans
12. Route the cable with the connector labeled P2 in front of both front blower assemblies.
13. Route the cable with the connector labeled P1 in front of the right front blower assembly.
14. Connect the power cables to the server board and peripherals. See Figure 29 :

— On each board, connect the main power cable. This connector is labeled P1 for the board on the right, and P2 for the board on the left. See letters “A” and “B” in Figure 29 on page 38.

— On each hard drive, connect the power cable. The connector to the top drive is labeled P3 and the connector to the bottom drive is labeled P4. See letters “C” and “D” in Figure 29 on page 38

15. Install the server system cover. For instructions, see “Installing the Server System Cover” .
16. Plug all peripheral devices and the AC power cable into the server.

Replacing the Fans

The individual blower fans and memory cooling fans can be replaced if a fan fails. The fans that are integrated into the power supply cannot be replaced. If one of the fans in the power supply fails, the power supply must be replaced.

must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Page 61 of the Intel SR1520ML user manual — Replacing a Blower Fan
Pagina 61 · clicca per ingrandire
Pagina 61

Replacing a Blower Fan

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” .
4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 28 .
5. The fan cables are tucked underneath the main power supply cable. For ease of access, disconnect the main power supply cable on both server boards. See letter “A” in the following figure.
6. Disconnect the fan cable from each server board. See letter “B” in the figure.
Intel SR1520ML — Replacing a Blower Fan diagram (page 61)
Fig. 34 · Replacing a Blower Fan

Figure 32. Disconnecting Cables

7. Remove the five screws that hold the fan bracket in place. Save these screws. You will re-install them later. See letter “A” in the figure below.
8. Lift the fan bracket with the attached fans from the server, working it out from underneath the front panel, USB, and SATA cables. See letter “B” in the figure.
Page 62 of the Intel SR1520ML user manual — Replacing a Blower Fan
Pagina 62 · clicca per ingrandire
Pagina 62
Intel SR1520ML — Replacing a Blower Fan diagram (page 62)
Fig. 35 · Replacing a Blower Fan

Figure 33. Removing Bracket and Fans

Page 63 of the Intel SR1520ML user manual — Replacing a Blower Fan
Pagina 63 · clicca per ingrandire
Pagina 63
9. Turn the bracket over and remove the two screws that attach the failed fan to the bracket. Save these screws. You will reinstall them later. See letter “A” in the figure below.
10. Lift the fan from the bracket. See letter “B”.
Intel SR1520ML — Replacing a Blower Fan diagram (page 63)
Fig. 36 · Replacing a Blower Fan

Figure 34. Removing Fan from Fan Bracket

11. Install the replacement fan onto the bracket, using the two screws you removed in step 9.
12. Set the fan assembly into the system. Use caution to make sure you do not pinch any cables.
13. Connect the fan cables to the Fan_3 connectors on each server board.
14. Route the front panel cables and the main power cables between the blower fan and the memory cooling fans.
15. Route the left USB and SATA cables between the left blower fan and left memory cooling fan.
16. Route the right USB and SATA cables between the left side of the right memory cooling fan and the right side of the left blower fan.
17. Route the left main power cable between the the left blower fan and left memory cooling fan.
18. Route the right main power cable between the right blower fan and the right memory cooling fan.
19. Bundle the fan cables for each board together. Hold them in place under the cable for the main power cable while you connect the main power cables. Use caution to make sure you do not pinch any cables when you connect the main power supply connectors. Make sure the fan cables will not block airflow from the memory cooling fans.
Page 64 of the Intel SR1520ML user manual — Replacing a Memory Cooling Fan
Pagina 64 · clicca per ingrandire
Pagina 64
20. Install the processor air duct. For instructions. see “Installing the Processor Air Duct” on page 29 .

Replacing a Memory Cooling Fan

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” .
4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 28 .
5. (optional) The fan cables are tucked underneath the main power supply cable. For ease of access, disconnect the main power supply. See letter “A” in the following figure.
6. Follow the fan cable from the failed fan to the Y-connector. Detach the fan cable at they Y-connector. See letter “B” in the figure.
7. Remove the two screws that attach the fan to the fan bracket. Save these screws. You will re-install them later. See letter “C”.
8. Remove the fan. See letter “D”.
Intel SR1520ML — Replacing a Memory Cooling Fan diagram (page 64)
Fig. 37 · Replacing a Memory Cooling Fan
Page 65 of the Intel SR1520ML user manual — Replacing a Memory Cooling Fan
Pagina 65 · clicca per ingrandire
Pagina 65
9. Set the replacement fan into place. See letter “A” in the following figure. When correctly positioned, the fan cable extends from the top right side of the fan, at the rear.
10. Install the screws you removed in step 7 to secure the fan to the bracket. See letter “B” in the figure.
11. Connect the fan cable at the Y-connector. See letter “C”
12. If you removed the main power cable, bundle the fan cables together and hold them in place under the cable for the main power cable while you connect the main power cables. Use caution to make sure you do not pinch any cables when you connect the main power supply connectors. Make sure the fan cables will not block airflow from the memory cooling fans. See letter “D”
Intel SR1520ML — Replacing a Memory Cooling Fan diagram (page 65)
Fig. 38 · Replacing a Memory Cooling Fan
13. Install the processor air duct. For instructions. see “Installing the Processor Air Duct” on page 29 .
Page 66 of the Intel SR1520ML user manual — — USB_2_3
Pagina 66 · clicca per ingrandire
Pagina 66

Replacing a Server Board

Removing the Server Board

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 28 .
5. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 21 .
6. Detach all cables connected at the front of the server board:

cable.

— Main power. The cable end is labeled P1 for the server board at the right and P2 for the server board at the left. Press and hold down on the tab at the center of the connector while you pull on the connector.

7. Detach the cables connected at the rear of the server board:

— USB_2_3

— SATA_0

8. Remove the heat sink and the processor. For instructions, see “Removing the Heat Sink and Processor” on page 33 .
9. Remove the DIMMs. For instructions, see “Removing DIMMs” on page 32 .
10. Remove the six screws from the server board (see letter “A”) and lift the server board from the server system (see letter “B”).

— Front panel · — Sys_fan_3

Page 67 of the Intel SR1520ML user manual — Replacing a Server Board
Pagina 67 · clicca per ingrandire
Pagina 67
Intel SR1520ML — Replacing a Server Board diagram (page 67)
Fig. 39 · Replacing a Server Board

Figure 37. Removing the Server Board

11. Choose the appropriate action:

— Install a replacement the server board. For instructions, see “Installing the Server Board” on page 48.

— Continue with the following steps to reassemble and close the server system without replacing the server board.

12. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 29 .
13. Install the server system cover. For instructions, see “Installing the Server System Cover” .
14. Plug all peripheral devices and the AC power cable into the server.
15. Store the components you removed (processor, DIMMs, PCI riser assembly, server board) in anti-static bags for future use.
Page 68 of the Intel SR1520ML user manual — Installing the Server Board
Pagina 68 · clicca per ingrandire
Pagina 68

Installing the Server Board

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the processor air duct. For instructions, see “Removing the Processor Air Duct” on page 28 .
5. Remove the PCI riser assembly. For instructions, see “Removing the PCI Riser Assembly” on page 21 .
6. Place the server board into the server system as shown by letter “A” in the figure below.
7. Attach the server board with six screws. See letter “B” in the figure.
Intel SR1520ML — Installing the Server Board diagram (page 68)
Fig. 40 · Installing the Server Board

Figure 38. Installing the Server Board

8. Install the processor and the heat sink. For instructions, see “Installing the Processor” on page 35 .
9. Install the system memory. For instructions, see “Installing DIMMs” on page 30 .
Page 69 of the Intel SR1520ML user manual — Installing the Server Board
Pagina 69 · clicca per ingrandire
Pagina 69
  • Use caution when connecting cables to make sure you do not pinch any cables.
  • For data cable routing information, see “Cable Routing” on page 67 .
  • For power cable routing information, see “Cable Routing” on page 67 .
10. Connect the cables at the front of the server board.

— Main power. The cable end is labeled P1 for the server board at the right and P2 for the server board at the left. Several cables lay underneath this connector. Be sure the cables do not get pinched in the connector. See letter “A” in the following figure.

— Front panel (letter “E”)

— Sys_fan_3 (letter “D”)

11. Connect the cables at the rear of the server board.

— USB_2_3 (letter “C”)

— SATA_0 (letter “B”)

Intel SR1520ML — Installing the Server Board diagram (page 69)
Fig. 41 · Installing the Server Board

Figure 39. Connecting Cables to Server Board

Page 70 of the Intel SR1520ML user manual — Replacing the Front Panel Board
Pagina 70 · clicca per ingrandire
Pagina 70
12. Install the PCI riser assembly. For instructions, see “Installing the PCI Riser Assembly” on page 22 .
13. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” on page 29 .
14. Install the server system cover. For instructions, see “Installing the Server System Cover” .
15. Plug all peripheral devices and the AC power cable into the server.

Replacing the Front Panel Board

you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Your server must be operated with a control panel installed.

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the power supply cables from the cable harness.
5. (optional) For easier access, lift the power supply from place.

cables.

6. Remove the screw that attaches the front panel board to the server system. See letter “A” in the figure below. Save these screws. You will re-install them later.
7. Slide the front panel board rearward and then lift it from the server. See letter “B” in the figure.

board.

8. Disconnect the front panel cable and the USB cables from the front panel board. For ease of identification, the USB cables are two different colors. Note which color is attached to which server board.
Page 71 of the Intel SR1520ML user manual — Replacing the Front Panel Board
Pagina 71 · clicca per ingrandire
Pagina 71
Intel SR1520ML — Replacing the Front Panel Board diagram (page 71)
Fig. 42 · Replacing the Front Panel Board

Figure 40. Removing Front Panel Board

9. Connect the USB and front panel cables to the replacement front panel board. See letter “A” in the following figure.
10. Set the front panel board into place, inserting the two knobs on the floor of the system through the two holes in the front panel board. See letter “B” in the figure.
11. Slide the front panel board foward to match the screw holes in the board and system. Screw the front panel board into place. See letter s “C” and “D” in the figure.
Page 72 of the Intel SR1520ML user manual — Replacing the CMOS Battery
Pagina 72 · clicca per ingrandire
Pagina 72
Intel SR1520ML — Replacing the CMOS Battery diagram (page 72)
Fig. 43 · Replacing the CMOS Battery

Figure 41. Installing Front Panel Board

12. Tuck the USB and SATA cables into place under the lip at the front of the system.
13. If you removed the power supply, set it back into place.
14. Route the power cables into the cable harness.
15. Install the server system cover. For instructions, see “Installing the Server System Cover” .
16. Plug all peripheral devices and the AC power cable into the server.

Replacing the CMOS Battery

battery, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet.

Page 73 of the Intel SR1520ML user manual — Replacing the CMOS Battery
Pagina 73 · clicca per ingrandire
Pagina 73

The lithium battery on the server board powers the RTC in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices.

equivalent type recommended by the equipment manufacturer. Discard used batteries according to manufacturer's instructions.

AdvarselLithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning må kun ske med

batteri af samme fabrikat og type. Levér det brugte batteri tilbage til leverandøren.

AdvarselLithiumbatteri - Eksplosjonsfare. Ved utskifting benyttes kun batteri som anbefalt av

apparatfabrikanten. Brukt batteri returneres apparatleverandøren.

Varning: Explosionsfara vid felaktigt batteribyte. Använd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera använt batteri enligt fabrikantens instruktion.

VaroitusParisto voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan

laitevalmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo valmistajan ohjeiden mukaisesti.

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see “Removing the Server System Cover” on page 14 .
4. Remove the server's cover and locate the battery. See Figure 42 .
5. Pull back gently on the metal tab at the top of the battery.
6. Remove the battery from its socket.
Page 74 of the Intel SR1520ML user manual — Replacing the CMOS Battery
Pagina 74 · clicca per ingrandire
Pagina 74
Intel SR1520ML — Replacing the CMOS Battery diagram (page 74)
Fig. 44 · Replacing the CMOS Battery

Figure 42. Removing the CMOS Battery

7. Dispose of the battery according to local ordinance.
8. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket. The “+” sign needs to face the rear of the system.
9. Install the system cover. For instructions, see “Installing the Server System Cover” on page 15 .
10. Run the BIOS Setup utility to restore the configuration settings.
Page 75 of the Intel SR1520ML user manual — Installing the Rack Handles
Pagina 75 · clicca per ingrandire
Pagina 75

Installing and Removing the Rack Handles

Installing the Rack Handles

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
Intel SR1520ML — Installing the Rack Handles diagram (page 75)
Fig. 45 · Installing the Rack Handles
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Attach the rack handle to the server system with two screws as shown in the figure below.

Figure 43. Installing the Rack Handle

4. Repeat step 3 on the opposite side of the server.
5. Plug all peripheral devices and the AC power cable into the server.
Page 76 of the Intel SR1520ML user manual — Removing the Rack Handles
Pagina 76 · clicca per ingrandire
Pagina 76

Removing the Rack Handles

1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” on page iii .
Intel SR1520ML — Removing the Rack Handles diagram (page 76)
Fig. 46 · Removing the Rack Handles
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the two screws holding the rack handle in place, and remove the rack handle from the server system as shown in the figure below.

Figure 44. Removing the Rack Handle

4. Repeat step 3 on the opposite side of the system.
5. Plug all peripheral devices and the AC power cable into the server.
Page 77 of the Intel SR1520ML user manual — Setup Menus
Pagina 77 · clicca per ingrandire
Pagina 77

3 Server Utilities

Using the BIOS Setup Utility

This section describes the BIOS Setup Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See Table 1 on page xix for a link to the Technical Product Specification where you will find details about specific BIOS setup screens.

Starting Setup

You can enter and start BIOS Setup under several conditions:

  • When you turn on the server, after POST completes the memory test.
  • When you have moved the CMOS jumper on the server board to the "Clear CMOS" position (enabled).

In the two conditions listed above, during the Power On Self Test (POST), you will see this prompt: Press to enter SETUP

In a third condition, when CMOS/NVRAM has been corrupted, you will see other prompts but not the prompt: Warning: CMOS checksum invalid Warning: CMOS time and date not set

In this condition, the BIOS will load default values for CMOS and attempt to boot.

If You Cannot Access Setup

If you are not able to access BIOS Setup, you might need to clear the CMOS memory. For instructions on clearing the CMOS, see "Clearing the CMOS".

Setup Menus

Each BIOS Setup menu page contains a number of features. Except for those features that are provided only to display automatically configured information, each feature is associated with a value field that contains user-selectable parameters. These parameters can be changed if the user has adequate security rights. If a value cannot be changed for any reason, the feature's value field is inaccessible.

Page 78 of the Intel SR1520ML user manual — 3 Server Utilities
Pagina 78 · clicca per ingrandire
Pagina 78

“Setup Menu Key Use” describes the keyboard commands you can use in the BIOS Setup menus.

Table 4. Setup Menu Key Use

Key to Press Description

Execute Command - The key is used to activate submenus when the selected feature is a submenu, or to display a pick list if a selected feature has a value field, or to select a sub-field for multi-valued features like time and date. If a pick list is displayed, the key will undo the pick list, and allow another selection in the parent menu.

Exit - The key provides a mechanism for backing out of any field. This key will undo the pressing of the key. When the key is pressed while editing any field or selecting features of a menu, the parent menu is re-entered. When the key is pressed in any submenu, the parent menu is re-entered. When the key is pressed in any major menu, the exit confirmation window is displayed and the user is asked whether changes can be discarded.

Left and right arrows The left and right arrow keys are used to move between the major menu pages. The keys have no affect if a submenu or pick list is displayed.

Up arrow Select Item up - The up arrow is used to select the previous value in a menu item's option list, or a value field pick list. Pressing the key activates the selected item.

Down arrow Select Item down - The down arrow is used to select the next value in a menu item's option list, or a value field pick list. Pressing the key activates the selected item.

Change Value - The minus key or the function key is used to change the value of the current item to the previous value. This key scrolls through the values in the associated pick list without displaying the full list.

Change Value - The plus key or the function key is used to change the value of the current menu item to the next value. This key scrolls through the values in the associated pick list without displaying the full list. On 106-key Japanese keyboards, the plus key has a different scan code than the plus key on the other keyboard, but it has the same effect.

Pressing on any menu invokes the general help window.

Setup Defaults - Pressing causes the following to appear:

[Yes] [No] If "Yes" is selected and the key is pressed, all Setup fields are set to their default values. If "No" is selected and the key is pressed, or if the key is pressed, the user is returned to where they were before was pressed without affecting any existing field values.

Load Optimized Defaults?

Page 79 of the Intel SR1520ML user manual — Recording the Current BIOS Settings
Pagina 79 · clicca per ingrandire
Pagina 79

Table 4. Setup Menu Key Use

Key to Press Description

Save and Exit - Pressing causes the following message to appear:

Save Configuration and reset?

[Yes] [No] If "Yes" is selected and the key is pressed, all changes are saved and Setup is exited. If "No" is selected and the key is pressed, or the key is pressed, the user is returned to where they were before was pressed without affecting any existing values.

Upgrading the BIOS

The upgrade utility allows you to upgrade the BIOS in flash memory. The code and data in the upgrade file include the following:

  • On-board system BIOS, including the recovery code, BIOS Setup Utility, and strings.
  • On-board video BIOS, SATA BIOS, and other option ROMs for devices embedded on the server board.
  • OEM binary area
  • Microcode

Preparing for the Upgrade

The steps below explain how to prepare to upgrade the BIOS, including how to record the current BIOS settings and how to obtain the upgrade utility.

process may need to be followed to return the system to service. See Table 1 on page xix for a link to necessary software and instrutions.

Recording the Current BIOS Settings

1. Boot the computer and press when you see the message: Press Key if you want to run SETUP
2. Write down the current settings in the BIOS Setup program.

the procedure.

Page 80 of the Intel SR1520ML user manual — Recovering the BIOS
Pagina 80 · clicca per ingrandire
Pagina 80

Obtaining the Upgrade

Download the BIOS image file to a temporary folder on your hard drive. See Table 1 on page xix for a link to the update software.

with the BIOS image file before attempting a BIOS upgrade. The release notes contain critical information regarding jumper settings, specific fixes, or other information to complete the upgrade.

Upgrading the BIOS

Follow the instructions in the readme file that came with the BIOS upgrade. When the update completes, remove the bootable media from which you performed the upgrade.

automatically when the BIOS update process is completed.

happens, shut down the system and boot it again. CMOS checksum errors require that you enter Setup, check your settings, save your settings, and exit Setup.

Recovering the BIOS

1. Power down the system and disconnect the AC power.
2. Open the server.
3. Move the J1A2 BIOS Recovery Mode jumper from the default operation position, covering pins 1 and 2 to the BIOS Recovery position, covering pins 2 and 3 as indicated in the following diagram.
Page 81 of the Intel SR1520ML user manual — Obtaining the Upgrade
Pagina 81 · clicca per ingrandire
Pagina 81
Intel SR1520ML — Obtaining the Upgrade diagram (page 81)
Fig. 47 · Obtaining the Upgrade

Figure 45. BIOS Recovery Mode Jumper in Recovery Position

4. Inserts the BIOS recovery medium.
5. Plug in the AC power and power on the system.

The BIOS starts the recovery process by loading and booting to the recovery image file. Then the BIOS POST screen appears and displays the progress.

6. Select to boot to the EFI SHELL.
7. Run Update.NSH. The system loads and executes the flash update application. A message displays success or failure upon completion.
8. Power down the system and unplug the AC power cord.
9. Return the J1A2 BIOS Recovery Mode jumper to the default position, covering pins 1 and 2.
10. Close the server chassis.
11. Reconnect the AC power and power up the server.
Page 82 of the Intel SR1520ML user manual — Clearing the Password
Pagina 82 · clicca per ingrandire
Pagina 82

Clearing the Password

If the user or administrator password(s) is lost or forgotten, moving the password clear jumper into the "clear" position clears both passwords. The password clear jumper must be restored to its original position before a new password(s) can be set.

1. Power down the system and disconnect the AC power.
2. Open the server chassis.
3. Move the J6B1 Password Clear jumper from the normal operation position, Password Clear Protect, at pins 1 and 2 to the Password Clear Erase position, covering pins 2 and 3 as indicated in the following diagram.
Intel SR1520ML — Clearing the Password diagram (page 82)
Fig. 48 · Clearing the Password

Figure 46. Password Clear Jumper in Clear Password Position

4. Reconnect the AC power and power up the system.
5. Power down the system and disconnect the AC power.
6. Return the J6B1 Password Clear jumper to the Password Clear Protect position, covering pins 1 and 2.
Page 83 of the Intel SR1520ML user manual — Clearing the CMOS
Pagina 83 · clicca per ingrandire
Pagina 83
7. Close the server chassis.
8. Reconnect the AC power and power up the server.

Clearing the CMOS

If you are not able to access the BIOS setup screens, the CMOS Clear jumper will need to be used to reset the configuration RAM.

1. Power down the system and disconnect the AC power.
2. Open the server.
3. Move the J1A3 CMOS Clear jumper from the normal operation position, CMOS Clear by BMC, at pins 1 and 2 to the CMOS Clear Force Erase position, covering pins 2 and 3 as indicated in the following diagram.
Intel SR1520ML — Clearing the CMOS diagram (page 83)
Fig. 49 · Clearing the CMOS

Figure 47. CMOS Clear Jumper in Clear CMOS Position

4. Reconnect the AC power, power up the system.
5. When the system begins beeping, power it down and disconnect the AC power.
Page 84 of the Intel SR1520ML user manual — Performing an iBMC Force Update
Pagina 84 · clicca per ingrandire
Pagina 84
6. Return the J1A3 CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2.
7. Close the server chassis.
8. Reconnect the AC power and power up the system.

Performing an iBMC Force Update

When performing a standard iBMC firmware update procedure, the update utility places the iBMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event that the iBMC firmware update process fails because the iBMC not in the proper update state, the server board provides a BMC Force Update jumper (J3A1) that will force the iBMC into the proper update state. The following procedure should be following if the standard iBMC firmware update process fails.

1. Power down the system and disconnect the AC power.
2. Open the server.
3. Move the J3A1 iBMC Force Update jumper from the default position, covering pins 1 and 2 to the Write Enable position, covering pins 2 and 3 as indicated in the following diagram.
Page 85 of the Intel SR1520ML user manual — Performing an iBMC Force Update
Pagina 85 · clicca per ingrandire
Pagina 85
Intel SR1520ML — Performing an iBMC Force Update diagram (page 85)
Fig. 50 · Performing an iBMC Force Update

Figure 48. MiBMC Force Update Jumper in the Write Enable Position

4. Close the server system and reconnect AC power and power up the server.
5. Perform the standard iBMC firmware update procedure as documented in README.TXT file that is included in the given BMC Firmware Update package.
6. After successful completion of the firmware update process, the firmware update utility may generate an error stating that the iBMC is still in update mode.
7. Power down and remove AC power.
8. Open the server and move the jumper from the “enabled” position (pins 2-3) to the “disabled” position (pins 1-2).
9. Close the server system and reconnect AC power and power up the server.
10. Normal iBMC functionality is disabled when the force BMC update jumper is set to the “enabled” position. The server should never be run with the BMC force update jumper set in this position and should only be used when the standard firmware update process fails. This jumper should remain in the default, disabled position when the server is running normally.
Page 86 of the Intel SR1520ML user manual — Using the iBMC Boot Block Write Protect Jumper (J1A4)
Pagina 86 · clicca per ingrandire
Pagina 86

Using the iBMC Boot Block Write Protect Jumper (J1A4)

The iBMC boot block write protect jumper (J1A4) is protection for the boot block portion of the iBMC firmware. The default position of the jumper is covering pins 1-2. This protects the boot block from being written to during an iBMC firmware update. In most cases there is no need to update the boot block. Most update utilities are not built with the authority to access this section of code.

In the unlikely event that the boot block must be written to, the J1A4 jumper must be moved to cover pins 2-3 to enable the update. Once the update is complete and the system is turned off, always remember to reposition the jumper back to ‘write-protect’ mode, covering pins pins 1-2.

the iBMC hardware. If this flash area becomes corrupted, then the iBMC may be rendered useless and inoperable. For this reason jumper protection is applied to this area of the flash so a user does not mistakenly write to this boot block.

Page 87 of the Intel SR1520ML user manual — Appendix A: Technical Reference
Pagina 87 · clicca per ingrandire
Pagina 87

Appendix A: Technical Reference

Cable Routing

When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing.

Page 88 of the Intel SR1520ML user manual — Power Cable Routing
Pagina 88 · clicca per ingrandire
Pagina 88

Power Cable Routing

Intel SR1520ML — Power Cable Routing diagram (page 88)
Fig. 51 · Power Cable Routing
Intel SR1520ML — Power Cable Routing diagram (page 88)
Fig. 52 · Power Cable Routing

A. Memory fan (one for each server board) C. Main power (one for each server board)

B. Blower fan (one for each server board) D. Drive power. Daisy cable (one connection to power a drive for each server board)

Figure 49. Power Cable Routing

Page 89 of the Intel SR1520ML user manual — Data Cable Routing
Pagina 89 · clicca per ingrandire
Pagina 89

Data Cable Routing

Intel SR1520ML — Data Cable Routing diagram (page 89)
Fig. 53 · Data Cable Routing
Intel SR1520ML — Data Cable Routing diagram (page 89)
Fig. 54 · Data Cable Routing

A. Y-USB cable. One end to Intel® Z-U130 Value Solid State Drive (optoinal). The other end to the front panel. (one for each server board

C. Y-Front panel cable. One end attaches to each server board.

B. SATA to hard drive. (one for each server board)

Figure 50. Data Cable Routing

Page 90 of the Intel SR1520ML user manual — 600 W Power Supply Output Voltages
Pagina 90 · clicca per ingrandire
Pagina 90

600 W Power Supply Input Voltages

  • 100 - 127 V at 50 / 60 Hz 6.0 A
  • 200 - 240 V at 50 / 60 Hz 3.0 A

600 W Power Supply Output Voltages

The table below lists the total wattage available from the power subsystem for each voltage. For information about calculating the power usage for your configuration, see “Calculating Power Usage.”

Table 5. Power Supply Output Capability

+3.3 V 20 Amp

+5.0 V 24 Amp

+5.0 V Standby 3 Amp

+12.0 V1 16 Amp

+12.0 V2 16 Amp

+12.0 V3 16 Amp

+12.0 V4 16 Amp

-12.0 V 0.5 Amp

Exceeding a combined 90 Watts will overload the power subsystem and may cause the power supply to overheat and malfunction.

Voltage Maximum Current

Page 91 of the Intel SR1520ML user manual — System Environmental Specifications
Pagina 91 · clicca per ingrandire
Pagina 91

System Environmental Specifications

Table 6. System Environmental Specifications

-40 ° to 70 °C.

10 ° to 30 °C, with the maximum rate of change not to exceed 10 ° C per hour

Non-operating 90% relative humidity, non-condensing at 35 °C.

2.0 g, 11 msec, 1/2 sine

Operational after an 24-inch free fall.

Acoustic noise 7 Bels in sound power for a typical office ambient temperature (65-75 °F). Your selection of peripherals may change the noise level.

Tested to 15 kilovolts (kV); no component damage.

Show 8 more labels / short text on this page
Temperature · Non-operating · Operating · Humidity · Shock · Operating · Packaged · Electrostatic discharge (ESD)
Page 92 of the Intel SR1520ML user manual — System Environmental Specifications
Pagina 92 · clicca per ingrandire
Pagina 92
Page 92 of the Intel SR1520ML user manual — System Environmental Specifications
Page 93 of the Intel SR1520ML user manual — Appendix B: Installation/Assembly
Pagina 93 · clicca per ingrandire
Pagina 93

Appendix B: Installation/Assembly

Safety Instructions

English

The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel.

Intel SR1520ML — Appendix B: Installation/Assembly diagram (page 93)
Fig. 55 · Appendix B: Installation/Assembly

Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply.

The power button on the system does not turn off system AC power. To remove AC power from the system, you must unplug each AC power cord from the wall outlet or power supply.

Intel SR1520ML — Appendix B: Installation/Assembly diagram (page 93)
Fig. 56 · Appendix B: Installation/Assembly

The power cord(s) is considered the disconnect device to the main (AC) power. The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessible.

SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps:

1. Turn off all peripheral devices connected to the system. 2. Turn off the system by pressing the power button. 3. Unplug all AC power cords from the system or from wall outlets. 4. Label and disconnect all cables connected to I/O connectors or ports on the back of the system. 5. Provide some electrostatic discharge (ESD) protection by wearing an antistatic wrist strap attached to chassis ground of the system-any unpainted metal surface-when handling components. 6. Do not operate the system with the chassis covers removed.

Page 94 of the Intel SR1520ML user manual — Appendix B: Installation/Assembly Safety Instructions
Pagina 94 · clicca per ingrandire
Pagina 94

After you have completed the six SAFETY steps above, you can remove the system covers. To do this:

Intel SR1520ML — Appendix B: Installation/Assembly Safety Instructions diagram (page 94)
Fig. 57 · Appendix B: Installation/Assembly Safety Instruction…
1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s).

For proper cooling and airflow, always reinstall the chassis covers before turning on the system. Operating the system without the covers in place can damage system parts. To install the covers:

Intel SR1520ML — Appendix B: Installation/Assembly Safety Instructions diagram (page 94)
Fig. 58 · Appendix B: Installation/Assembly Safety Instruction…
1. Check first to make sure you have not left loose tools or parts inside the system. 2. Check that cables, add-in boards, and other components are properly installed. 3. Attach the covers to the chassis with the screws removed earlier, and tighten them firmly. 4. Insert and lock the padlock to the system to prevent unauthorized access inside the system. 5. Connect all external cables and the AC power cord(s) to the system.

A microprocessor and heat sink may be hot if the system has been running. Also, there may be sharp pins and edges on some board and chassis parts. Contact should be made with care. Consider wearing protective gloves.

The system is designed to operate in a typical office environment. Choose a site that is:

  • Clean and free of airborne particles (other than normal room dust).
  • Well ventilated and away from sources of heat including direct sunlight.
  • Away from sources of vibration or physical shock.
  • Isolated from strong electromagnetic fields produced by electrical devices.
  • In regions that are susceptible to electrical storms, we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm.
  • Provided with a properly grounded wall outlet.
  • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect.
Page 95 of the Intel SR1520ML user manual — Resetting the System
Pagina 95 · clicca per ingrandire
Pagina 95

Appendix C: Troubleshooting

This chapter helps you identify and solve problems that might occur while you are using the system.

For any issue, first ensure you are using the latest firmware and files. Firmware upgrades include updates for BIOS, and the Baseboard Management Controller (BMC). See “Server System References” on page xix for a link to the software updates. In addition to the server firmware and files, also update any drivers used for components you have installed in your system, such as video drivers, network drivers, and SATA drivers.

Intel provides a package called the “Platform Confidence Test” that may help with your diagnostics. See “Server System References” on page xix for a link to this software.

If you are unable to resolve your server problems on your own, see “Getting Help” on page 95 for assistance.

Resetting the System

Before going through in-depth troubleshooting, attempt first to reset your system using one of the methods below.

Table 7. Resetting the System

To do this Press

Soft boot reset to clear the system memory and reload the operating system

Clear system memory, restart POST, and reload the operating system Reset button

Cold boot reset. Turn the system power off and then on. This clears system memory, restarts POST, reloads the operating system, and halts power to all peripherals

Reset the BMC and get it back to a stable state Remove AC power from the server for one minute

· Power off/on button

Page 96 of the Intel SR1520ML user manual — Hardware Diagnostic Testing
Pagina 96 · clicca per ingrandire
Pagina 96

Problems following Initial System Installation

Problems that occur at initial system startup are usually caused by an incorrect installation or configuration. Hardware failure is a less frequent cause. If the problem you are experiencing is with a specific software application, see “Problems with Newly Installed Application Software” on page 92.

First Steps Checklist

  • Is AC power available at the wall outlet?
  • Are the power supplies plugged in? Check the AC cable(s) on the back of the chassis and at the AC source.
  • Are all cables correctly connected and secured?
  • Is the processors fully seated in its socket on the server board?
  • Are all add-in PCI boards fully seated in their slots on the server board?
  • Are all jumper settings on the server board correct?
  • Are all jumper and switch settings on add-in boards and peripheral devices correct? To check these settings, refer to the manufacturer's documentation that comes with them. If applicable, ensure that there are no conflicts-for example, two add-in boards sharing the same interrupt.
  • Are all peripheral devices installed correctly?
  • If the system has a hard disk drive, is it properly formatted or configured?
  • Are all device drivers properly installed?
  • Are the configuration settings made in Setup correct?
  • Is the operating system properly loaded? See the operating system documentation.
  • Did you press the system power on/off switch on the front panel to turn the server on (power on light should be lit)?
  • Is the system power cord properly connected to the system and plugged into a NEMA 5 15R outlet for 100-120V or a NEMA 6-15R outlet for 200-240V?
  • Are all integrated components from the tested components lists? Check the tested memory, and chassis lists, as well as the supported hardware and operating system list. See “Server System References” on page xix for links to the tested component lists.

Hardware Diagnostic Testing

This section provides a more detailed approach to identifying a hardware problem and locating its source.

Page 97 of the Intel SR1520ML user manual — Specific Problems and Corrective Actions
Pagina 97 · clicca per ingrandire
Pagina 97

from the system, turn off the system and any external peripheral devices. Failure to do so can cause permanent damage to the system and/or the peripheral devices.

1. Turn off the system and all external peripheral devices. Disconnect each device from the system, except for the keyboard and the video monitor.
2. Make sure the system power cord is plugged into a properly grounded AC outlet.
3. Make sure your video display monitor and keyboard are correctly connected to the system. Turn on the video monitor. Set its brightness and contrast controls to at least two thirds of their maximum ranges (see the documentation supplied with your video display monitor).
4. Turn on the system. If the power LED does not light, see “Power Light Does Not Light” on page 88 .

Verifying Proper Operation of Key System Lights

As POST determines the system configuration, it tests for the presence of each mass storage device installed in the system. As each device is checked, its activity light should turn on briefly. Check for the following:

  • Does the drive activity light turn on briefly? If not, see “Drive Activity Light Does Not Light” on page 90 .

Confirming Loading of the Operating System

Once the system boots up, the operating system prompt appears on the screen. The prompt varies according to the operating system. If the operating system prompt does not appear, see “No Characters Appear on Screen” on page 88.

Specific Problems and Corrective Actions

This section provides possible solutions for these specific problems:

  • Power light does not light.
  • No characters appear on screen.
  • Characters on the screen appear distorted or incorrect.
  • Cooling fans do not rotate.
  • USB diskette drive activity light does not light.
  • Hard disk drive activity light does not light.
  • USB CD-ROM drive activity light does not light.
  • There are problems with application software.
  • The bootable USB CD-ROM is not detected.
Page 98 of the Intel SR1520ML user manual — No Characters Appear on Screen
Pagina 98 · clicca per ingrandire
Pagina 98

Try the solutions below in the order given. If you cannot correct the problem, contact your service representative or authorized dealer for help.

Power Light Does Not Light

Check the following:

  • Did you press the power-on button?
  • This server system has two server boards. Did you press the power button for the correct server board?
  • Is the system operating normally? If so, the power LED might be defective or the connection from the control panel to the server board might be loose.
  • Have you securely plugged the server AC power cord into the power supply?
  • Remove all add-in cards and see if the system boots. If successful, add the cards back in one at a time with a reboot between each addition.
  • Make sure the memory DIMMs comply with the system requirements.
  • Make sure the memory DIMMs have been populated according to the system requirements.
  • Remove the memory DIMMs and re-seat them.
  • Make sure the processor complies with the system requirements.
  • Remove the processor and re-seat it.

No Characters Appear on Screen

Check the following:

  • This server system has two server boards. Is the video monitor connected to the correct server board?
  • Is the keyboard functioning? Test it by turning the “Num Lock” function on and off to make sure the Num Lock light is functioning.
  • Is the video monitor plugged in and turned on? If you are using a switch box, is it switched to the correct system?
  • Are the brightness and contrast controls on the video monitor properly adjusted?
  • Is the video monitor signal cable properly installed?
  • Does this video monitor work correctly if plugged into a different system?
  • Is the onboard video controller enabled in the BIOS?
  • Remove all add-in cards and see if the video returns. If successful, add the cards back in one at a time with a reboot between each addition.
  • Make sure the memory DIMMs comply with the system requirements.
  • Make sure the memory DIMMs have been populated according to the system requirements.
Page 99 of the Intel SR1520ML user manual — System Cooling Fans Do Not Rotate Properly
Pagina 99 · clicca per ingrandire
Pagina 99
  • Remove the memory DIMMs and re-seat them.
  • Make sure the processor(s) comply with the system requirements.
  • Make sure the processor(s) have been populated according to the system requirements.
  • Remove the processor(s) and re-seat them.

If you are using an add-in video controller board, do the following:

1. Verify that the video works using the onboard video controller.
2. Verify that the video controller board is fully seated in the server board connector.
3. Reboot the system for changes to take effect.
4. If there are still no characters on the screen after you reboot the system and POST emits a beep code, write down the beep code you hear. This information is useful for your service representative.
5. If you do not receive a beep code and characters do not appear, the video display monitor or video controller may have failed. Contact your service representative or authorized dealer for help.

Characters Are Distorted or Incorrect

Check the following:

  • Are the brightness and contrast controls properly adjusted on the video monitor? See the manufacturer's documentation.
  • Are the video monitor's signal and power cables properly installed?
  • Does this video monitor work correctly if plugged into a different system?

System Cooling Fans Do Not Rotate Properly

If the system cooling fans are not operating properly, it is an indication of possible system component failure.

Check the following:

  • Is the power-on light lit? If not, see “Power Light Does Not Light” on page 88 .
  • Are any other control panel LEDs lit?
  • Have any of the fan motors stopped? Use the server management subsystem to check the fan status.
  • Have your fans speeded up in response to an overheating situation?
  • Have your fans speeded up in response to a fan that has failed?
  • Are the fan power connectors properly connected to the server board?
  • Is the cable from the control panel board connected to the both the control panel board and to the server board?
Page 100 of the Intel SR1520ML user manual — Cannot Connect to a Server
Pagina 100 · clicca per ingrandire
Pagina 100
  • Are the power supply cables properly connected to the server board?
  • Are there any shorted wires caused by pinched-cables or have power connector plugs been forced into power connector sockets the wrong way?

Drive Activity Light Does Not Light

Check the following:

  • Are the drive's power and signal cables properly installed?
  • Are all relevant switches and jumpers on the drive set correctly?
  • Is the drive properly configured?
  • Is the drive activity light always on? If so, the signal cable may be plugged in incorrectly.

CD-ROM Drive or DVD-ROM Drive Activity Light Does Not Light

Check the following:

  • Are the CD-ROM/DVD-ROM drive's power and signal cables properly installed?
  • Are all relevant switches and jumpers on the drive set correctly?
  • Is the drive properly configured?

Cannot Connect to a Server

  • Make sure the network cable is securely attached to the correct connector at the system back panel.
  • Try a different network cable.
  • Make sure you are using the correct and the current drivers. See “Server System References” on page xix for a link to the current drivers.
  • Make sure the driver is loaded and the protocols are bound.
  • Make sure the hub port is configured for the same duplex mode as the network controller.
  • Make sure the correct networking software is installed.
  • If you are directly connecting two servers (without a hub), you will need a crossover cable.
  • Check the network controller LEDs next to the NIC connectors.
Page 101 of the Intel SR1520ML user manual — System Boots when Installing PCI Card
Pagina 101 · clicca per ingrandire
Pagina 101

Problems with Network

The server hangs when the drivers are loaded

  • Certain drivers may require interrupts that are not shared with other PCI drivers. For these drivers, it may be necessary to alter settings so that interrupts are not shared. See the documentation that came with your PCI card(s) for information on changing interrupts.

Diagnostics pass but the connection fails

  • Make sure the network cable is securely attached.
  • Make sure you specify the correct frame type in your NET.CFG file.
  • The controller stopped working when an add-in adapter was installed.
  • Make sure the cable is connected to the port from the onboard network controller.
  • Make sure your BIOS is current. See “Server System References” on page xix for a link to the current version.
  • Make sure the other adapter supports shared interrupts. Make sure your operating system supports shared interrupts.
  • Try reseating the add-in adapter.

The add-in adapter stopped working without apparent cause

  • Reseat the adater.
  • The network driver files may be corrupt or deleted. Delete and then reinstall the drivers.
  • Run diagnostics.

System Boots when Installing PCI Card

System Management features require full-time “standby” power. This means some parts of the system have power going to them whenever the power cord is plugged in, even if you have turned the system power off with the power button on the front panel. If you install a PCI card with the AC power cord plugged in, a signal may be sent to command the system to boot. Before installing a PCI card, you should always:

  • Turn off the server power by using the power button on the front of the system.
  • Unplug the AC power cord(s) from the server.
Page 102 of the Intel SR1520ML user manual — Problems with Application Software that Ran Correctly Earlier
Pagina 102 · clicca per ingrandire
Pagina 102

Problems with Newly Installed Application Software

Problems that occur when you run new application software are usually related to the software, not the server hardware. Faulty equipment is unlikely, especially if other software runs correctly.

Check the following:

  • Make sure the system meets the minimum hardware requirements for the software. See the software documentation.
  • Make sure the software is properly installed and configured for the system. See the software documentation.
  • Use only an authorized copy. Unauthorized copies often do not work.
  • If you are running the software from a USB CD-ROM or DVD-ROM, try a different disk.
  • Make sure the correct device drivers installed.

If the problems persist, contact the software vendor's customer service representative.

Problems with Application Software that Ran Correctly Earlier

Problems that occur after the system hardware and software have been running correctly sometimes indicate equipment failure. However, they can also be caused by file corruption or changes to the software configuration.

Check the following:

  • If you are running the software from a USB CD-ROM or DVD-ROM, try a different disk.
  • Check your system for a virus infection.
  • Uninstall and reinstall the software. Make sure all necessary files are installed.
  • If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard input is incorrect), a marginal power supply, or other random component failures.
  • If you suspect that a transient voltage spike, power outage, or brownout might have occurred, reload the software and try running it again. Symptoms of voltage spikes include a flickering video display, unexpected system reboots, and the system not responding to user commands.

be getting corrupted by voltage spikes on your power line. If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line, you may want to install a surge suppressor between the power outlet and the system power cord.

Page 103 of the Intel SR1520ML user manual — Bootable CD-ROM Disk Is Not Detected
Pagina 103 · clicca per ingrandire
Pagina 103

Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)

The Microsoft* Windows* operating systems do not include all of the drivers for the Intel® chipsets, onboard NICs, and other components. See “Server System References” on page xix for a link to the current drivers and chipset files.

Hard Drive(s) are not Recognized

Check the following:

  • Make sure the drive is not disabled in BIOS Setup.
  • Make sure the drive is connected correctly and that is plugged into the power supply.
  • Make sure the drive is compatible. See “Server System References” on page xix for a link to the tested drives.
  • Make sure you have not exceeded the power budget for the server. See “Server System References” on page xix for a link to software to check your power budget.
  • If using SCSI drives, verify that each SCSI ID number is unique on the SCSI bus. See your drive documentation for details on setting the SCSI ID for your drives.
  • If using ATA drives, verify that the master/slave settings are set correctly. See your drive documentation for details on setting the master/slave settings.
  • If using a RAID configuration with SCSI or SATA drives, make sure the RAID card is installed correctly.

Bootable CD-ROM Disk Is Not Detected

Check the following:

  • Make sure the BIOS is configured to allow the USB CD-ROM to be the first bootable device.
Page 104 of the Intel SR1520ML user manual — Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)
Pagina 104 · clicca per ingrandire
Pagina 104
Page 104 of the Intel SR1520ML user manual — Devices are not Recognized under Device Manager (Microsoft* Windows* Operating System)
Page 105 of the Intel SR1520ML user manual — UK .............. 870 6072439
Pagina 105 · clicca per ingrandire
Pagina 105

Appendix D: Getting Help

World Wide Web

http://support.intel.com/support/motherboards/server/X38ML

Telephone

All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice).

Before calling, fill out an Issue Report Form, available at http://support.intel.com/support/ motherboards/server/X38ML.

For an updated support contact list, see http://www.intel.com/support/9089.htm/

U.S. and Canada

See http://support.intel.com/support/motherboards/server/X38ML

Europe

Belgium 02 714 3182

Denmark... 38 487077

Finland 9 693 79297

France 01 41 918529

Germany... 069 9509 6099

Holland 020 487 4562

Italy 02 696 33276

Norway 23 1620 50

Spain 91 377 8166

Sweden 08 445 1251

UK 870 6072439

Page 106 of the Intel SR1520ML user manual — Latin America
Pagina 106 · clicca per ingrandire
Pagina 106

In Asia-Pacific region

Australia 1800 649931

Cambodia.. 63 2 636 9797 (via Philippines)

China 800 820 1100 (toll-free)

8 621 33104691 (not toll-free)

Hong Kong 852 2 844 4456

India 0006517 2 68303634 (manual toll-free. You need an IDD-equipped

Indonesia... 803 65 7249

Korea 822 767 2595

Malaysia 1 800 80 1390

Myanmar... 63 2 636 9796 (via Philippines)

New Zealand 0800 444 365

Pakistan 632 63684 15 (IDD via Philippines)

Philippines 1 800 1 651 0117

Singapore.. 65 6213-1311

Taiwan 2 2545-1640

Thailand 1 800 631 0003

Vietnam 632 6368416 (IDD via Philippines)

Japan

Domestic 0120 868686

Outside country 81 298 47 0800

Latin America

Argentina.. Contact AT&T USA at 0-800 222 1288. Once connected, dial 800 843 4481

Brazil 001-916 377 0180

Easter Island Contact AT&T USA at 800 800 311. Once connected, dial 800 843 4481 Mainland and Juan.. Contact AT&T USA at 800 225 288. Once connected, dial 800 843 4481

telephone) · Chile

Page 107 of the Intel SR1520ML user manual — In Asia-Pacific region
Pagina 107 · clicca per ingrandire
Pagina 107

Colombia... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481

Costa Rica. Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481

(Andimate) Contact AT&T USA at 1 999 119. Once connected, dial 800 843 4481 (Pacifictel) Contact AT&T USA at 1 800 225 528. Once connected, dial 800 843 4481

Guatemala. Contact AT&T USA at 99 99 190. Once connected, dial 800 843 4481

Mexico Contact AT&T USA at 001 800 462 628 4240. Once connected, dial 800 843

Miami 1 800 621 8423

Panama Contact AT&T USA at 00 800 001 0109. Once connected, dial 800 843 4481

Paraguay... 001 916 377 0114

Peru 001 916 377 0114

Uruguay 001 916 377 0114

Venezuela... Contact AT&T USA at 0 800 2255 288. Once connected, dial 800 843 4481

Ecuador

Page 108 of the Intel SR1520ML user manual — In Asia-Pacific region
Pagina 108 · clicca per ingrandire
Pagina 108
Page 108 of the Intel SR1520ML user manual — In Asia-Pacific region
Page 109 of the Intel SR1520ML user manual — Extent of Limited Warranty
Pagina 109 · clicca per ingrandire
Pagina 109

Appendix E: Warranty

Limited Warranty for Intel® Chassis Subassembly Products

Intel warrants that the Products (defined herein as the Intel® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and installed, will be free from defects in material and workmanship and will substantially conform to Intel's publicly available specifications for a period of three (3) years after the date the Product was purchased from an Intel authorized distributor. Software of any kind delivered with or as part of products is expressly provided "as is" unless specifically provided for otherwise in any software license accompanying the software.

If any Product furnished by Intel which is the subject of this Limited Warranty fails during the warranty period for reasons covered by this Limited Warranty, Intel, at its option, will:

  • REPAIR the Product by means of hardware and/or software; OR
  • REPLACE the Product with another Product; OR
  • REFUND the then-current value of the Product if Intel is unable to repair or replace the Product.

If such Product is defective, transportation charges for the return of Product to buyer within the USA will be paid by Intel. For all other locations, the warranty excludes all costs of shipping, customs clearance, and other related charges. Intel will have a reasonable time to make repairs or to replace Product or to refund the then-current value of the Product.

In no event will Intel be liable for any other costs associated with the replacement or repair of Product, including labor, installation or other costs incurred by buyer and in particular, any costs relating to the removal or replacement of any product soldered or otherwise permanently affixed to any printed circuit board.

This Limited Warranty, and any implied warranties that may exist under state law, apply only to the original purchaser of the Product.

Extent of Limited Warranty

Intel does not warrant that Products to be delivered hereunder, whether delivered stand- alone or integrated with other Products, including without limitation semiconductor components, will be free from design defects or errors known as "errata." Current characterized errata are available upon request.

Page 110 of the Intel SR1520ML user manual — Limitations of Liability
Pagina 110 · clicca per ingrandire
Pagina 110

This Limited Warranty does not cover damages due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing.

Warranty Limitations and Exclusions

These warranties replace all other warranties, expressed or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel makes no expressed warranties beyond those stated here. Intel disclaims all other warranties, expressed or implied including, without limitation, implied warranties of merchantability and fitness for a particular purpose. Some jurisdictions do not allow the exclusion of implied warranties, so this limitation may not apply.

All expressed and implied warranties are limited in duration to the limited warranty period. No warranties apply after that period. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so this limitation may not apply to you.

Limitations of Liability

Intel's responsibility under this, or any other warranty, implied or expressed, is limited to repair, replacement, or refund, as set forth above. These remedies are the sole and exclusive remedies for any breach of warranty. Intel is not responsible for direct, special, incidental, or consequential damages resulting from any breach of warranty under another legal theory including, but not limited to, lost profits, downtime, goodwill, damage to or replacement of equipment and property, and any costs of recovering, reprogramming, or reproducing any program or data stored in or used with a system containing this product. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.

This limited warranty gives you specific legal rights, and you may also have other rights that vary from jurisdiction to jurisdiction.

Any and all disputes arising under or related to this Limited Warranty shall be adjudicated in the following forums and governed by the following laws: for the United States of America, Canada, North America, and South America, the forum shall be Santa Clara, California, USA, and the applicable law shall be that of the State of California, USA; for the Asia Pacific region, the forum shall be Singapore and the applicable law shall be that of Singapore; for Europe and the rest of the world, the forum shall be London and the applicable law shall be that of the United Kingdom.

In the event of any conflict between the English language version and any other translated version(s) of this Limited Warranty, the English language version shall control.

Page 111 of the Intel SR1520ML user manual — Returning a Defective Product
Pagina 111 · clicca per ingrandire
Pagina 111

How to Obtain Warranty Service

To obtain warranty service for this Product, you may contact Intel or your authorized distributor.

  • North America and Latin America To obtain warranty repair for the product, please go to the following Web site to obtain instructions: <a href="http://support.intel.com/support/" rel="nofollow noopener" target="_blank">http://support.intel.com/support/</a> motherboards/draform.htm
  • In Europe and in Asia Contact your original authorized distributor for warranty service.

Any replacement Product is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period.

Telephone Support

If you cannot find the information you need on Intel's World Wide Web site (http:// www.intel.com/), call your local distributor or an Intel Customer Support representative. See “Getting Help” for telephone numbers.

Returning a Defective Product

Before returning any product, call your authorized dealer/distribution authority.

Page 112 of the Intel SR1520ML user manual — Appendix E: Warranty
Pagina 112 · clicca per ingrandire
Pagina 112
Page 112 of the Intel SR1520ML user manual — Appendix E: Warranty
Page 113 of the Intel SR1520ML user manual — Safety Warnings and Cautions
Pagina 113 · clicca per ingrandire
Pagina 113

Appendix F: Safety Information

English

Server Safety Information

This document applies to Intel® server boards, Intel® server chassis (pedestal and rack- mount) and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or maintaining your Intel® server product.

In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.

Your server should be integrated and serviced only by technically qualified persons.

You must adhere to the guidelines in this guide and the assembly instructions in your server manuals to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products / components will void the UL Listing and other regulatory approvals of the product, and may result in noncompliance with product regulations in the region(s) in which the product is sold.

Safety Warnings and Cautions

To avoid personal injury or property damage, before you begin installing the product, read, observe, and adhere to all of the following safety instructions and information. The following safety symbols may be used throughout the documentation and may be marked on the product and / or the product packaging.

Indicates potential hazard if indicated information is ignored.

Indicates shock hazards that result in serious injury or death if safety instructions are not followed.

Indicates hot components or surfaces.

Page 114 of the Intel SR1520ML user manual — Equipment Handling Practices
Pagina 114 · clicca per ingrandire
Pagina 114

Indicates do not touch fan blades, may result in injury.

Indicates to unplug all AC power cord(s) to disconnect AC power

Intended Application Uses

This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than an ITE application, may require further evaluation.

Site Selection

The system is designed to operate in a typical office environment. Choose a site that is:

  • Clean, dry, and free of airborne particles (other than normal room dust).
  • Well-ventilated and away from sources of heat including direct sunlight and radiators.
  • Away from sources of vibration or physical shock.
  • Isolated from strong electromagnetic fields produced by electrical devices.
  • In regions that are susceptible to electrical storms, we recommend you plug your system into a surge suppresser and disconnect telecommunication lines to your modem during an electrical storm.
  • Provided with a properly grounded wall outlet.
  • Provided with sufficient space to access the power supply cord(s), because they serve as the product's main power disconnect.

Equipment Handling Practices

Reduce the risk of personal injury or equipment damage:

  • Conform to local occupational health and safety requirements when moving and lifting equipment.
  • Use mechanical assistance or other suitable assistance when moving and lifting equipment.
  • To reduce the weight for easier handling, remove any easily detachable components.

Please recycle battery

Page 115 of the Intel SR1520ML user manual — Power Cord Warnings
Pagina 115 · clicca per ingrandire
Pagina 115

Power and Electrical Warnings

off the system AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are unplugged. Make sure the AC power cord(s) is/are unplugged before you open the chassis, or add or remove any non hot-plug components.

Do not attempt to modify or use an AC power cord if it is not the exact type required. A separate AC cord is required for each system power supply.

Some power supplies in Intel® servers use Neutral Pole Fusing. To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing.

The power supply in this product contains no user-serviceable parts. Do not open the power supply. Hazardous voltage, current and energy levels are present inside the power supply. Return to manufacturer for servicing.

When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing it from the server.

To avoid risk of electric shock, turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it.

Power Cord Warnings

If an AC power cord was not provided with your product, purchase one that is approved for use in your country.

product as follows:

  • Do not attempt to modify or use the AC power cord(s) if they are not the exact type required to fit into the grounded electrical outlets
  • The power cord(s) must meet the following criteria:
  • The power cord must have an electrical rating that is greater than that of the electrical current rating marked on the product.
  • The power cord must have safety ground pin or contact that is suitable for the electrical outlet.
  • The power supply cord(s) is/are the main disconnect device to AC power. The socket outlet(s) must be near the equipment and readily accessible for disconnection.
  • The power supply cord(s) must be plugged into socket-outlet(s) that is /are provided with a suitable earth ground.
Page 116 of the Intel SR1520ML user manual — Rack Mount Warnings
Pagina 116 · clicca per ingrandire
Pagina 116

System Access Warnings

whenever accessing the inside of the product:

  • Turn off all peripheral devices connected to this product.
  • Turn off the system by pressing the power button to off.
  • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet.
  • Disconnect all cables and telecommunication lines that are connected to the system.
  • Retain all screws or other fasteners when removing access cover(s). Upon completion of accessing inside the product, refasten access cover with original screws or fasteners.
  • Do not access the inside of the power supply. There are no serviceable parts in the power supply. Return to manufacturer for servicing.
  • Power down the server and disconnect all power cords before adding or replacing any non hot-plug component.
  • When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing the power supply from the server.

Unless you are adding or removing a hot-plug component, allow the system to cool before opening the covers. To avoid the possibility of coming into contact with hot component(s) during a hot-plug installation, be careful when removing or installing the hot-plug component(s).

over the fan, do not operate the system without the fan guard in place.

Rack Mount Warnings

The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions.

Install equipment in the rack from the bottom up, with the heaviest equipment at the bottom of the rack.

Extend only one piece of equipment from the rack at a time.

You are responsible for installing a main power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the server(s).

To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it.

Page 117 of the Intel SR1520ML user manual — Laser Peripherals or Devices
Pagina 117 · clicca per ingrandire
Pagina 117

Electrostatic Discharge (ESD)

all procedures at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground -- any unpainted metal surface -- on your server when handling parts.

Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.

Other Hazards

Battery Replacement

battery, use only the battery recommended by the equipment manufacturer.

Dispose of batteries according to local ordinances and regulations.

Do not attempt to recharge a battery.

Do not attempt to disassemble, puncture, or otherwise damage a battery.

Cooling and Airflow

For proper cooling and airflow, operate the system only with the chassis covers installed. Operating the system without the covers in place can damage system parts. To install the covers:

  • Check first to make sure you have not left loose tools or parts inside the system.
  • Check that cables, add-in boards, and other components are properly installed.
  • Attach the covers to the chassis according to the product instructions.

Laser Peripherals or Devices

  • Do not open the enclosure of any laser peripheral or device
  • Laser peripherals or devices have are not user serviceable
  • Return to manufacturer for servicing
Page 118 of the Intel SR1520ML user manual — Product Safety Compliance
Pagina 118 · clicca per ingrandire
Pagina 118

Appendix G: Regulatory and

Compliance Information

Product Regulatory Compliance

guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products/components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold.

To help ensure EMC compliance with your local regional rules and regulations, before computer integration, make sure that the server system, power supply, and other modules have passed EMC testing using a server board with a microprocessor from the same family (or higher) and operating at the same (or higher) speed as the microprocessor used on this server board. The final configuration of your end system product may require additional EMC compliance testing. For more information, please contact your local Intel representative.

This is an FCC Class A device. Integration of it into a Class B system does not result in a Class B device.

Product Safety Compliance

This server system product, when correctly integrated per this guide, complies with the following safety and electromagnetic compatibility (EMC) regulations.

Intended Application

This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as: medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment, etc.), other than an ITE application, may require further evaluation.

Product Safety Compliance

The server system complies with the following product safety requirements:

  • UL60950 - CSA 60950 (USA / Canada)
  • EN60950 (Europe)
  • IEC60950 (International)
Page 119 of the Intel SR1520ML user manual — Product EMC Compliance - Class A Compliance
Pagina 119 · clicca per ingrandire
Pagina 119
  • CB Certificate & Report, IEC60950 (report to include all country national deviations)
  • GS License (Germany)
  • GOST R 50377-92 - License (Russia)
  • Belarus License (Belarus)
  • Ukraine License (Ukraine)
  • CE - Low Voltage Directive 73/23/EEE (Europe)
  • IRAM Certification (Argentina)
  • GB4943CNCA Certification (China)

Product EMC Compliance - Class A Compliance

This server system has been tested and verified to comply with the following electromagnetic compatibility (EMC) regulations when installed in a compatible Intel® host system. For information on compatible host system(s) refer to Intel's Server Builder Web site or contact your local Intel representative.

  • FCC /ICES-003 - Emissions (USA/Canada) Verification
  • ICES-003 - (Canada)
  • CISPR 22 - Emissions (International)
  • EN55022 - Emissions (Europe)
  • EN55024 - Immunity (Europe)
  • EN61000-3-2 - Harmonics (Europe)
  • EN61000-3-3 - Voltage Flicker (Europe)
  • CE - EMC Directive 89/336/EEC (Europe)
  • VCCI Emissions (Japan)
  • AS/NZS 3548 Emissions (Australia / New Zealand)
  • BSMI CNS13438 Emissions (Taiwan)
  • GOST R 29216-91 Emissions (Russia)
  • GOST R 50628-95 Immunity (Russia)
  • Belarus License (Belarus)
  • Ukraine License (Ukraine)
  • RRL MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) (Korea)
  • GB 9254 - CNCA Certification (China)
  • GB 17625 - (Harmonics) CNCA Certification (China)
Page 120 of the Intel SR1520ML user manual — Product Regulatory Compliance Markings
Pagina 120 · clicca per ingrandire
Pagina 120

Certifications / Registrations / Declarations

  • UL Certification (US/Canada)
  • CB Certification (International)
  • CE Declaration of Conformity (CENELEC Europe)
  • GS Certification (Germany)
  • FCC/ICES-003 Class A Attestation (USA/Canada)
  • VCCI Certification (Japan)
  • C-Tick Declaration of Conformity (Australia)
  • MED Declaration of Conformity (New Zealand)
  • BSMI Certification (Taiwan)
  • GOST R Certification / License (Russia)
  • Belarus Certification / License (Belarus)
  • RRL Certification (Korea)
  • IRAM Certification (Argentina)
  • CNCA Certification (China)
  • Ecology Declaration (International)

Product Regulatory Compliance Markings

This Intel® server system product is provided with the following regulatory marks.

Table 8. Product Regulatory Compliance Markings

Regulatory Compliance Region Marking

cULus Listing Marks USA/Canada

IRAM Mark Argentina · GS Mark Germany

Page 121 of the Intel SR1520ML user manual — Certifications / Registrations / Declarations
Pagina 121 · clicca per ingrandire
Pagina 121

Table 8. Product Regulatory Compliance Markings

Regulatory Compliance Region Marking

FCC Marking (Class A) USA

Intel SR1520ML — Certifications / Registrations / Declarations diagram (page 121)
Fig. 59 · Certifications / Registrations / Declarations

EMC Marking (Class A) Canada

C-Tick Mark Australia / New Zealand

VCCI Marking (Class A) Japan

Intel SR1520ML — Certifications / Registrations / Declarations diagram (page 121)
Fig. 60 · Certifications / Registrations / Declarations

BSMI Certification Number & Class A Warning

Intel SR1520ML — Certifications / Registrations / Declarations diagram (page 121)
Fig. 61 · Certifications / Registrations / Declarations

GOST R Marking Russia

RRL MIC Mark Korea

China Compulsory Certification Mark

CE Mark Europe · Taiwan · China

Page 122 of the Intel SR1520ML user manual — Certifications / Registrations / Declarations
Pagina 122 · clicca per ingrandire
Pagina 122

Table 8. Product Regulatory Compliance Markings

Regulatory Compliance Region Marking

Ground Mark Nordic Line1"WARNING:"
Swedish on line2"Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk."
Finnish on line 3"Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan."
English on line 4"Connect only to a properly earth grounded outlet."

Recycling Other than China

CA. Lithium Perchlorate insert

Perchlorate Material - Special handling may apply. See www.dtsc.ca.gov/hazardouswaste/ perchlorate

This notice is required by California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials. This product / part includes a battery which contains Perchlorate material.

Country of Origin Made in XXXX

WEEE Mark · RoHS China · Recycling Mark China

Page 123 of the Intel SR1520ML user manual — FCC Verification Statement (USA)
Pagina 123 · clicca per ingrandire
Pagina 123

Electromagnetic Compatibility Notices

FCC Verification Statement (USA)

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E. Elam Young Parkway Hillsboro, OR 97124-6497 1-800-628-8686

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. The customer is responsible for ensuring compliance of the modified product.

Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC Class A or B limits may be attached to this computer product. Operation with noncompliant peripherals is likely to result in interference to radio and TV reception.

All cables used to connect to peripherals must be shielded and grounded. Operation with cables, connected to peripherals, that are not shielded and grounded may result in interference to radio and TV reception.

Page 124 of the Intel SR1520ML user manual — BSMI (Taiwan)
Pagina 124 · clicca per ingrandire
Pagina 124

Industry Canada (ICES-003)

Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Apparelis Numériques", NMB-003 édictee par le Ministre Canadian des Communications.

English translation of the notice above:

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled: "Digital Apparatus," ICES-003 of the Canadian Department of Communications.

Europe (CE Declaration of Conformity)

This product has been tested in accordance to, and complies with the Low Voltage Directive (73/23/EEC) and EMC Directive (89/336/EEC). The product has been marked with the CE Mark to illustrate its compliance.

VCCI (Japan)

Intel SR1520ML — VCCI (Japan) diagram (page 124)
Fig. 62 · VCCI (Japan)

English translation of the preceding notice:

This is a Class A product based on the standard of the Voluntary Control Council for Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual.

BSMI (Taiwan)

Intel SR1520ML — BSMI (Taiwan) diagram (page 124)
Fig. 63 · BSMI (Taiwan)

The BSMI Certification Marking and EMC warning is located on the outside rear area of the product.

Page 125 of the Intel SR1520ML user manual — 声明
Pagina 125 · clicca per ingrandire
Pagina 125

Korean Compliance (RRL)

Following is the RRL certification information for Korea.

Intel SR1520ML — Korean Compliance (RRL) diagram (page 125)
Fig. 64 · Korean Compliance (RRL)

English translation of the notice above:

1. Type of Equipment (Model Name): On License and Product
2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative
3. Name of Certification Recipient: Intel Corporation
4. Date of Manufacturer: Refer to date code on product
5. Manufacturer/Nation: Intel Corporation/Refer to country of origin marked on product

CNCA (CCC-China)

The CCC Certification Marking and EMC warning is located on the outside rear area of the product.

声明

此为 A 级产品,在生活环境中,该产品可能会造成无 线电干扰。在这种情况下,可能需要用户对其干扰采 取可行的措施。

Regulated Specified Components

To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to. Interchanging or use of other components will void the UL listing and other product certifications and approvals.

Updated product information for configurations can be found on the Intel Server Builder Web site at the following URL: http://channel.intel.com/go/serverbuilder

If you do not have access to Intel's Web address, please contact your local Intel representative.

  • Server Chassis: (base chassis is provided with power supply and fans) - UL listed.
  • Server board: you must use an Intel server board - UL recognized.
Page 126 of the Intel SR1520ML user manual — Product Ecology Requirements
Pagina 126 · clicca per ingrandire
Pagina 126
  • Add-in boards: must have a printed wiring board flammability rating of minimum UL94V-1. Add-in boards containing external power connectors and/or lithium batteries must be UL recognized or UL listed. Any add-in board containing modem telecommunication circuitry must be UL listed. In addition, the modem must have the appropriate telecommunications, safety, and EMC approvals for the region in which it is sold.
  • Peripheral Storage Devices: must be a UL recognized or UL listed accessory and TUV or VDE licensed. Maximum power rating of any one device is 19 watts. Total server configuration is not to exceed the maximum loading conditions of the power supply.

Product Ecology Requirements

Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. Suppliers Declarations of Conformity to the banned substances must be obtained from all suppliers; and a Material Declaration Data Sheet (MDDS) must be produced to illustrate compliance. Due verification of random materials is required as a screening / audit to verify suppliers declarations. The server board complies with the following ecology regulatory requirements:

  • All materials, parts and subassemblies must not contain restricted materials as defined in Intel’s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers – <a href="http://supplier.intel.com/ehs/environmental.htm" rel="nofollow noopener" target="_blank">http://supplier.intel.com/ehs/environmental.htm</a>
  • Europe - European Directive 2002/95/EC - Restriction of Hazardous Substances (RoHS)
  • Threshold limits and banned substances are noted below.

— Quantity limit of 0.1% by mass (1000 PPM) for Lead, Mercury, Hexavalent hromium, Polybrominated Biphenyls Diphenyl Ethers (PBB/PBDE)

— Quantity limit of 0.01% by mass (100 PPM) for Cadmium

  • China RoHS
  • All plastic parts that weigh >25gm shall be marked with the ISO11469 requirements for recycling. Example >PC/ABS<
  • EU Packaging Directive
  • German Green Dot
  • Japan Recycling
Page 127 of the Intel SR1520ML user manual — End-of-Life / Product Recycling
Pagina 127 · clicca per ingrandire
Pagina 127

End-of-Life / Product Recycling

Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back.

Fai una domanda su Intel SR1520ML

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Intel SR1520ML

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Intel SR1520ML manuale in PDF

156 pagine·4.7 MB·Server·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…