1 PRINTED IN U.S.A. 1212 P ART NO. 325370-000 MODELS BBCN375T754NV PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE.
2 FOREWORD The design of model BBCN375T754NV complies with the current edition of ANSI Z21.10.3/CSA 4.3 as automatic storage or automatic circulating tank type water heaters. Installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference for the materials and method of piping necessary .
3 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS W A TER HEA TER IF ANY P ART HAS BEEN UNDER W A TER. Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water .
4 INSULA TION BLANKETS Insul ation bl ankets available t o the gene ral publi c for exte rnal use on gas wa ter heater s are not requ ired for us e on your water he ater . The p urpos e of an insulat ion blan k et is to re duce th e standby hea t los s encou ntered wit h storage t ank water heate rs.
5 installed in a carpeted alcove or closet, the entire oor shall be covered by the panel. Also, see the drain requirements. THI S HE A T ER SHA LL BE LOCA TE D OR PROTECTED SO IT IS NOT SU BJECT TO PHYSIC AL DAM AGE BY A MOVIN G VEHIC LE.
6 CAUTION: IF BUILDING COLD W A TER SUPPL Y HAS A BACK-FLOW PREVENTER, CHECK V AL VE OR WA TER METER WITH CHECK V AL VE, PROVISIONS FOR THERMAL EXP ANSION OF W A TER IN THE HOT W A TER SYSTEM MUST BE PROVIDED. FIGURE 3. CIRCULA TING RETURN LINE CONNECTIONS TEMPERED W A TER LOOP , IF USED, CONNECT TO POINT "A".
7 THERMOMETERS (Not Supplied) The rmom eters sho uld be obt ained an d fie ld insta lled as sho wn in Figure 3. Thermometers are installed in the system as a means of detecting the temperature of the outlet water supply . COMBINA TION W A TER (POT ABLE) HEA TING AND SP ACE HEA TING 1 .
8 FIGURE 4. WIRING DIAGRAM AND SCHEMA TIC HEA TER WIRING All electrical work must be installed in the United States in accordance with the current edition of the National Electrical Code ANSI/NFP A No. 70, in Canada, with the current edition of Canadian Electrical Code CSA C22.
9 T ABLE 4. GAS SUPPL Y LINE SIZES (IN INCHES)* MAXIMUM CAP ACITY OF PIPE IN CUBIC FEET PER HOUR BEFORE PLACING THE HEATER IN OPERATION, CHECK FOR GAS LEAKAGE. Use soap and water solution or other material acceptable for the purpose in locating the leaks.
10 5. W ait ve (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to next step.
11 SETTING THE W A TER HEA TER TEMPERA TURE A T 120°F (49°C) (APPROX. " " MARK ON F ACE OF THE TEMPERA TURE ADJUSTING DIAL) WILL REDUCE THE RISK OF SCALDS. Some States or Provinces require settings at specic lower temperatures. Figure 6 shows the approximate water temperatures produced at various thermostat settings.
12 1. Provide complete combustion of gas. 2. Cause rapid ignition and carryover of ame across entire burner. 3. Give reasonably quiet operation during ignition, burning and extinction.
13 BLOWER MAINTENANCE For safety and satisfactory operation it is recommended that the blower be checked once a year by a competent service person. 1. MOTOR - The motor is factory oiled and sealed and requires no further maintenance. 2. WHEEL - Wheel must be clean of soot, ash or any other coating which inhibits either rotation or air ow .
14 T ANK CLEANOUT PROCEDURE The following practices will ensure longer life and enable the unit to operate at its designed efciency: 1. Once a month the heater should be ushed. Open the drain valve and allow two gallons of water to drain from the heater .
15 cold water inlet line and allow water to ow through heater and out drain valve. Don’t forget to plug vent and cap opening in Flo-Jug. 9. When ushing is completed: • Fill heater being certain to expel air from tank through a nearby hot water faucet or , if removed, the relief valve opening.
16 NOT E: Ano de must remai n install ed ( exce pt for inspe ctio n ) to avoid sh or tening ta nk life. See LI MITED WAR R ANT Y . Re place as necessary . SERVICE AND REP AIR The wate r heater req uires no sp ecial c are oth er than th e norma l mainte nance as n oted above.
17 TROUBLESHOOTING For your safety , water heater service should be performed only by a qualied service technician. Read the GENERAL SAFETY INFORMA TION section rst . PROBLEM POSSILBE MALFUNCTION SER VICE T O BE PERFORMED NOT ENOUGH OR NO HOT W A TER 1) Blower will not run.
18 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualied service technician. Read the GENERAL SAFETY INFORMA TION section rst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLEM SOLUTION Inadequate or no earth ground 1.
19 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualied service technician. Read the GENERAL SAFETY INFORMA TION section rst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLE MS OLUTION Ignition/flame failure.
20 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualied service technician. Read the GENERAL SAFETY INFORMA TION section rst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLE MS OLUTION 15 # LED ST AT US B C D E F 1.
21 NOTES.
22 NOTES.
23 Limited W arranty American W ater Heater Company , the warrantor , extends the following LIMITED WARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heat.
24 P .O. Box 1597, Johnson City , TN 37605 Phone: 800-456-9805 • Fax: 800-999-5210 www .americanwaterheater .com Copyright © 2012 American Water Heater Company .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il American Water Heater BBCN375T754NV è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del American Water Heater BBCN375T754NV - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso American Water Heater BBCN375T754NV imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul American Water Heater BBCN375T754NV ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il American Water Heater BBCN375T754NV, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del American Water Heater BBCN375T754NV.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il American Water Heater BBCN375T754NV. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo American Water Heater BBCN375T754NV insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.