IT
Intel logo
Manuale d'uso ufficiale

Intel MPCBL0001

166 pagine·1.5 MB·Computer portatile·PDF·ENDEFRITNLJA
Intel MPCBL0001
Indice dei contenuti 11 sezioni Intel NetStructure® MPCBL0001 High Performance Single Board Computer · Thermals 12 · 17.5 Japan VCCI Class A · 17.6 Korean Class A · … MostraNascondi
Page 1 of the Intel MPCBL0001 user manual — July 2005
Pagina 1 · clicca per ingrandire
Pagina 1

July 2005

Order Number273817-007
Page 3 of the Intel MPCBL0001 user manual — Contents
Pagina 3 · clicca per ingrandire
Pagina 3

Contents

Contents

1 Introduction 11

1.1 Document Organization 11 1.2 Glossary 12

2 Features Overview 14

2.1 Application 14 2.2 Functional Description 14 2.2.1 Low Voltage Intel® Xeon™ Processor CPU-0 (U35), CPU-1 (U36) 16 2.2.2 Chipset 17 2.2.2.1 Intel® E7501 Memory Controller Hub (U22) 17 2.2.2.2 Intel® 82801CA I/O Controller Hub 3 (U7) 18 2.2.2.3 Intel® 82870P2 64-bit PCI/PCI-X Controller Hub 2 (U14, U24) 19 2.2.3 Memory (J8, J9, J10, J11) 19 2.2.3.1 Memory Ordering Rule for the MCH 20 2.2.4 I/O 20 2.2.4.1 Super I/O (U28) 20 2.2.4.2 Real-Time Clock 21 2.2.4.3 Timer0 Capabilities 21 2.2.4.4 Gigabit Ethernet (U13) 21 2.2.4.5 Fibre Channel* (U23) - Optional 22 2.2.5 PMC Connector (J25, J26, J27) 23 2.2.6 Firmware Hub (U30, U33) 23 2.2.6.1 FWH 0 (Main BIOS) 24 2.2.6.2 FWH 1 (Backup/Recovery BIOS) 24 2.2.6.3 Flash ROM Backup Mechanism 24 2.2.7 Onboard Power Supplies 25 2.2.7.1 Power Feed Fuses 25 2.2.7.2 ORing Diodes and Circuit Breaker Protection 25 2.2.7.3 -48 V to +12 V Converter 25 2.2.7.4 -48 V to +5 V/+3.3 V Converter 25 2.2.7.5 Processor Voltage Regulator Module (VRM) 25 2.2.7.6 IPMB Standby Power 26

3 Hardware Management Overview 27

3.1 Sensor Data Record (SDR) 28 3.2 System Event Log (SEL) 30 3.2.1 Temperature and Voltage Sensors 34 3.2.2 Processor Events 39 3.2.3 DIMM Memory Events 39 3.2.4 System Firmware Progress (POST Error) 39 3.2.5 Critical Interrupts 39 3.2.6 System ACPI Power State 41 3.2.7 IPMB Link Sensor 41 3.2.8 FRU Hot Swap 41 3.2.9 CPU Failure Detection 41 3.2.10 Port 80h POST Codes 42 3.3 Field Replaceable Unit (FRU) Information 43

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 3 Technical Product Specification

Page 4 of the Intel MPCBL0001 user manual — Contents
Pagina 4 · clicca per ingrandire
Pagina 4

Contents

3.4 E-Keying 44 3.5 IPMC Firmware Code 44 3.6 IPMC Firmware Upgrade Procedure 45 3.6.1 IPMC Firmware Upgrade Using KCS Interface 45 3.6.2 IPMC Firmware Upgrade via the IPMB Interface (RMCP) 46 3.6.2.1 Updating MPCBL0001 Firmware 47 3.7 OEM IPMI Commands 47 3.7.1 Reset BIOS Flash Type 47 3.7.2 Set Fibre Channel Port Selection 48 3.7.3 Get Fibre Channel Port Selection 48 3.7.4 Get HW Fibre Channel Port Selection 49 3.7.5 Set Control State 49 3.7.6 Get Control State 50 3.7.7 Get Port80 Data 50 3.8 Controls Identifier Table 50 3.9 Hot-Swap Process 51 3.9.1 Hot-Swap LED (DS10) 52 3.9.2 Ejector Mechanism 52 3.10 Interrupts and Error Reporting 53 3.10.1 Device Interrupts 53 3.10.2 Error Reporting 55 3.11 ACPI 56 3.11.1 System States and Power States 56 3.12 Reset Types 56 3.12.1 Reset Logic 57 3.12.2 Hard Reset Request 57 3.12.3 Soft Reset Request 57 3.12.4 Warm Boot 58 3.12.5 Cold Boot 59 3.12.6 Power Good 59 3.13 Watchdog Timers (WDTs) 62 3.13.1 WDT #1 62 3.13.2 WDT #2 63 3.13.3 WDT #3 63 3.14 LED Status 64 3.14.1 Health LED 64 3.14.2 OOS (Out Of Service) LED 64 3.14.3 Hot-Swap LED 64 3.14.4 IDE Drive Activity LED 65 3.14.5 User Programmable LEDs 65 3.14.6 Network Link/Speed LEDs 66 3.14.7 Ethernet Controller Port State LEDs 66 3.14.8 Fibre Channel Port State LEDs 67 3.15 FRU Payload Control 67 3.15.1 Cold Reset 68 3.15.2 Warm Reset 68 3.15.3 Graceful Reboot 68 3.15.4 Diagnostic Interrupt 69

Page 5 of the Intel MPCBL0001 user manual — Contents
Pagina 5 · clicca per ingrandire
Pagina 5

Contents

4 Connectors 70

4.1 Backplane Connectors 74 4.1.1 Power Distribution Connector (Zone 1) 74 4.1.2 Data Transport Connector (Zone 2) 75 4.1.3 Alignment Blocks 76 4.2 Front Panel Connectors 77 4.2.1 USB Connector (J12) 77 4.2.2 Serial Port Connector (J17) 77 4.2.3 Fibre Channel Small Form-Factor Pluggable (SFP) Receptacle (J34 and J35) 80 4.2.4 Fibre Channel SFP Optical Transceiver Module 80 4.2.5 PMC Connectors (J25, J26, J27) 81 4.3 On-board Connectors 84 4.3.1 IDE Connector (J24) 84

5 Addressing 85

5.1 Configuration Registers 85 5.1.1 Configuration Address Register MCH CONFIG_ADDRESS 85 5.1.2 Configuration Data Register MCH CONFIG_ADDRESS 85 5.2 I/O Address Assignments 86 5.3 Memory Map 87 5.4 IPMC Addresses 88

6 Specifications 89

6.1 Mechanical Specifications 89 6.1.1 Board Outline 89 6.1.2 Backing Plate 92 6.1.3 Component Height 92 6.2 Environmental Specifications 97 6.3 Reliability Specifications 97 6.3.1 Mean Time Between Failure (MTBF) Specifications 97 6.3.1.1 Environmental Assumptions 98 6.3.1.2 General Assumptions 98 6.3.1.3 General Notes 98 6.3.2 Power Consumption 98 6.3.3 Cooling Requirements 99 6.4 Board Layer Specifications 99 6.5 Weight 99

7 BIOS Features 100

7.1 Introduction 100 7.2 BIOS Flash Memory Organization 100 7.3 Complementary Metal-Oxide Semiconductor (CMOS) 100 7.3.1 Copying and Saving CMOS Settings 100 7.4 Redundant BIOS Functionality 101 7.5 System Management BIOS (SMBIOS) 101 7.6 Legacy USB Support 102 7.7 BIOS Updates 102 7.7.1 Language Support 103 7.8 Recovering BIOS Data 103 7.9 Boot Options 103

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 5 Technical Product Specification

Page 6 of the Intel MPCBL0001 user manual — Contents
Pagina 6 · clicca per ingrandire
Pagina 6

Contents

7.9.1 CD-ROM and Network Boot 103 7.9.2 Booting without Attached Devices 103 7.10 Fast Booting Systems 104 7.10.1 Quick Boot 104 7.11 BIOS Security Features 104 7.12 Remote Access Configuration 105

8 BIOS Setup 106

8.1 Introduction 106 8.2 Main Menu 106 8.3 Advanced Menu 107 8.3.1 CPU Configuration Submenu 108 8.3.2 IDE Configuration Submenu 109 8.3.2.1 Primary IDE Master/Slave Submenu 110 8.3.3 Floppy Configuration Submenu 112 8.3.4 SuperIO Configuration Submenu 113 8.3.5 ACPI Configuration Submenu 114 8.3.5.1 Advanced ACPI Configuration Submenu 115 8.3.6 System Management Configuration Submenu 116 8.3.7 Event Logging Configuration Submenu 117 8.3.8 Fibre Channel Routing (PICMG) Configuration Submenu 118 8.3.9 Remote Access Configuration Submenu 119 8.3.10 USB Configuration Submenu 120 8.3.10.1 USB Mass Storage Device Configuration 121 8.3.11 PCI Configuration 121 8.4 Boot Menu 122 8.4.1 Boot Settings Configuration Submenu 122 8.4.2 Boot Device Priority Submenu 123 8.4.3 Hard Disk Drive Submenu 124 8.4.4 OS Load Timeout Timer 124 8.5 Security Menu 125 8.6 Exit Menu 125

9 Error Messages 127

9.1 BIOS Error Messages 127 9.2 Port 80h POST Codes 128

10 Operating the Unit 132

10.1 BIOS Configuration 132 10.2 BIOS Image Updates 132 10.3 Procedures to Copy and Save BIOS (Including CMOS Settings) 132 10.3.1 Copying BIOS.bin from the SBC 132 10.3.2 Saving BIOS.bin to the SBC 133 10.3.3 Error Messages 133 10.4 Jumpers 134 10.5 Digital Ground to Chassis Ground Connectivity 136

11 Maintenance 137

11.1 Supervision 137 11.2 Diagnostics 137 11.2.1 In-Target Probe (ITP) 137

Page 7 of the Intel MPCBL0001 user manual — Contents
Pagina 7 · clicca per ingrandire
Pagina 7

Contents

12 Thermals 138

13 Component Technology 139

14 Warranty Information 140

14.1 Intel NetStructure® Compute Boards and Platform Products Limited Warranty 140 14.2 Returning a Defective Product (RMA) 140 14.3 For the Americas 141 14.3.1 For Europe, Middle East, and Africa (EMEA) 141 14.3.2 For Asia and Pacific (APAC) 141

15 Customer Support 143

15.1 Customer Support 143 15.2 Technical Support and Return for Service Assistance 143 15.3 Sales Assistance 143 15.4 Product Code Summary 143

16 Certifications 144

17 Agency Information—Class A 145

17.1 North America (FCC Class A) 145 17.2 Canada – Industry Canada (ICES-003 Class A) (English and French-translated) 145 17.3 Safety Instructions (English and French-translated) 145 17.3.1 English 145 17.3.2 French 146 17.4 Taiwan Class A Warning Statement 146 17.5 Japan VCCI Class A 147 17.6 Korean Class A 147 17.7 Australia, New Zealand 147

18 Agency Information—Class B 148

18.1 North America (FCC Class B) 148 18.2 Canada – Industry Canada (ICES-003 Class B) (English and French-translated) 148 18.3 Safety Instructions (English and French-translated) 148 18.3.1 English 148 18.3.2 French 149 18.4 Japan VCCI Class B 149 18.5 Korean Class B 150 18.6 Australia, New Zealand 150

19 Safety Warnings 151

19.1 Mesures de Sécurité 152 19.2 Sicherheitshinweise 154 19.3 Norme di Sicurezza 156 19.4 Instrucciones de Seguridad 158 19.5 Chinese Safety Warning 160

A Reference Documents 161

B List of Supported Commands (IPMI v1.5 and PICMG 3.0) 163

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 7 Technical Product Specification

Page 8 of the Intel MPCBL0001 user manual — Contents
Pagina 8 · clicca per ingrandire
Pagina 8

Contents

Tables

1 P64H2 Interfaces 19 2 Hardware Sensors 28 3 SEL Events Supported by the MPCBL0001 SBC 31 4 Sensor Thresholds for IPMC Firmware 1.0 35 5 Sensor Thresholds for IPMC Firmware 1.2 36 6 Sensor Thresholds for IPMC Firmware 1.7 and Above 37 7 Sensor Thresholds for IPMC Firmware 1.14 and Above 38 8 PCI Mapping for Hardware Component Subsystem 40 9 CPU Failure Behavior 42 10 FRU Multirecord Data for CPU/RAM/PMC/BIOS Version Information 43 11 PMC Data 43 12 Link Descriptors for E-Keying 44 13 Reset BIOS Flash Type 47 14 Set Fibre Channel Port Selection 48 15 Get Fibre Channel Port Selection 48 16 Get HW Fibre Channel Port Selection 49 17 Set Control State 49 18 Get Control State 50 19 Get Port80 Data 50 20 Controls Identifier Table 50 21 Hot-Swap LED (DS11) 52 22 Interrupt Assignments 53 23 Power States and Targeted System Power 56 24 Reset Request 58 25 Reset Actions 59 26 Health LED 64 27 OOS LED (DS9) 64 28 IDE Drive Activity LED 65 29 User Programmable LEDs 65 30 GPIO Pin Connections 65 31 Network Link LEDs 66 32 Network Speed LEDs 66 33 Ethernet Controller Port State LED 67 34 Fibre Channel Port State LED (DS2, DS3) 67 35 CMM Commands for FRU Control Options 67 36 Returned Values from the Get Message Command 69 37 LED Descriptions 73 38 Connector Assignments 73 39 Power Distribution Connector (Zone 1) P10 Pin Assignments 74 40 Data Transport Connector (Zone 2) P23 Pin Assignments 76 41 USB Connector (J12) Pin Assignments 77 42 Serial Port Connector (J17) Pin Assignments 78 43 Fibre Channel SFP Copper Transceiver Module (AMP, J34, J35) 80 44 Fibre Channel SFP Pin Assignments 81 45 PMC Connector Pin Assignments - 32 Bit 82 46 PMC Connector Pin Assignments - 64 Bit 83 47 IDE Connector Pin Assignments 84 48 Configuration Address Register Bit Assignments 85 49 Configuration Data Register Bit Assignments 86

Page 9 of the Intel MPCBL0001 user manual — Contents
Pagina 9 · clicca per ingrandire
Pagina 9

Contents

50 I/O Address Cross-References 86 51 Memory Map 87 52 SMBus Addresses 88 53 Environmental Specifications 97 54 Reliability Estimate Data 97 55 Total Measured Power 98 56 Supervisor and User Password Functions 105 57 Function Key Escape Code Equivalents 105 58 BIOS Setup Program Menu Bar 106 59 BIOS Setup Program Function Keys 106 60 Main Menu 107 61 Advanced Menu 108 62 CPU Configuration Submenu 109 63 IDE Configuration Submenu 109 64 Primary IDE Master/Slave Submenu 111 65 Floppy Configuration Submenu 112 66 SuperIO Configuration Submenu 113 67 ACPI Configuration Submenu 114 68 Advanced ACPI Configuration Submenu 115 69 System Management Configuration Submenu 116 70 Event Logging Configuration Submenu 117 71 Fibre Channel Routing (PICMG) Submenu 118 72 Remote Access Configuration Submenu 119 73 USB Configuration Submenu 120 74 USB Mass Storage Device Configuration 121 75 PCI Configuration Submenu 122 76 Boot Menu 122 77 Boot Settings Configuration Submenu 123 78 Boot Device Priority Submenu 124 79 Hard Disk Drive Priority Submenu 124 80 OS Load Timeout Timer Submenu 125 81 Security Menu 125 82 Exit Menu 126 83 BIOS Error Messages 127 84 Bootblock Initialization Code Checkpoints 128 85 POST Code Checkpoints 129 87 ACPI Runtime Checkpoints 131 86 DIM Code Checkpoints 131 88 BIOS Beep Codes 131 89 Error Message 133 90 J18 Pin Assignments 135 91 J16 Jumper Assignments 135 92 J37 Jumper assignments 135 93 J40 Jumper Assignments 136 94 Hardware Monitoring Components 137 95 Main Components 139 96 MPCBL0001 Product Code Summary 143 97 IPMI 1.5 Supported Commands 163 98 PICMG 3.0 IPMI Supported Commands 165

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 9 Technical Product Specification

Page 10 of the Intel MPCBL0001 user manual — Revision History
Pagina 10 · clicca per ingrandire
Pagina 10

Contents

Figures

1 Intel NetStructure® MPCBL0001 SBC Block Diagram 15 2 Memory Ordering 20 3 Hardware Management Block Diagram 27 4 IPMC Firmware Code Process 45 5 Upgrade via Remote Management Node 46 6 Hot-Swap Process 51 7 Interrupt Signals 54 8 Power Good Map 59 9 Reset Chain 61 10 Watchdog Timers 62 11 Flow Diagram for Graceful Reboot Command 68 12 Diagnostic Interrupt Command Implementation 69 13 MPCBL0001 SBC Connector Locations 70 14 MPCBL0001NXX SBC Front Panel 71 15 MPCBL0001FXX SBC Front Panel 72 16 Power Distribution Connector (Zone 1) P10 74 17 Data Transport Connector (Zone 2) J23 75 18 Serial Port Connector (J17) 78 19 DB9 to RJ-45 Pin Translation 79 20 Intel NetStructure® MPCBL0001 Component Layout 90 21 Intel NetStructure® MPCBL0001 Component Layout 91 22 MPCBL0001 SBC Front Panel Dimensions – FC SKU (PMC and Connectors) 93 23 MPCBL0001 SBC Front Panel Dimensions – FC SKU (Screws and LEDs) 94 24 MPCBL0001 SBC Front Panel Dimensions – Non FC SKU (PMC and Connectors) 95 25 MPCBL0001 SBC Front Panel Dimensions – Non-FC SKU (Screws and LED) 96 26 Low Voltage Intel® Xeon™ Processor Heatsink 99 27 Jumper/Connector Locations 134 28 Connecting Digital Ground to Chassis Ground 136 29 Power vs. Flow Rate 138

Revision History

DateRevisionDescription July 2005007Added Table 7. Modified tables 3, 9, 13, 14, and 53; Fig. 21; and Section 10.5. April 2005006New text in sections 3.2.9, 6.5, 10.3.1, and tables 2, 3, and 6. February 2005005New text, figures; added Section 18, “Agency Information—Class B”. November 2004004Changes to figures 12, 13; changes to table 2, 3, 48, 77 and 81; added example to Section 3.2.5. June 2004003SRA Release - changed from release 002 to current. January 2004002Pre-SRA Release. October 2003001Initial public release of this document
Page 15 of the Intel MPCBL0001 user manual — Features Overview
Pagina 15 · clicca per ingrandire
Pagina 15

Features Overview

Figure 1. Intel NetStructure ® MPCBL0001 SBC Block Diagram

Intel MPCBL0001 — Features Overview diagram (page 15)
Fig. 1 · Features Overview

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 15 Technical Product Specification

Page 72 of the Intel MPCBL0001 user manual — Connectors
Pagina 72 · clicca per ingrandire
Pagina 72

Connectors

Figure 15. MPCBL0001FXX SBC Front Panel

Intel MPCBL0001 — Connectors diagram (page 72)
Fig. 2 · Connectors
Network Link LEDsL2 Ethernet Controller Port State: L1
Network Link LEDsL6 Ethernet Controller Port State: L5
Page 78 of the Intel MPCBL0001 user manual — Table 42. Serial Port Connector (J17) Pin Assignments
Pagina 78 · clicca per ingrandire
Pagina 78

Connectors

Figure 18. Serial Port Connector (J17)

Intel MPCBL0001 — Connectors diagram (page 78)
Fig. 3 · Connectors

Table 42. Serial Port Connector (J17) Pin Assignments

Intel MPCBL0001 — Table 42. Serial Port Connector (J17) Pin Assignments diagram (page 78)
Fig. 4 · Table 42. Serial Port Connector (J17) Pin Assignment…
Page 79 of the Intel MPCBL0001 user manual — Connectors
Pagina 79 · clicca per ingrandire
Pagina 79

Connectors

Figure 19. DB9 to RJ-45 Pin Translation

Intel MPCBL0001 — Connectors diagram (page 79)
Fig. 5 · Connectors
Intel MPCBL0001 — Connectors diagram (page 79)
Fig. 6 · Connectors

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 79 Technical Product Specification

Page 93 of the Intel MPCBL0001 user manual — Specifications
Pagina 93 · clicca per ingrandire
Pagina 93

Specifications

Figure 22. MPCBL0001 SBC Front Panel Dimensions – FC SKU (PMC and Connectors)

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 93 Technical Product Specification

Page 94 of the Intel MPCBL0001 user manual — Specifications
Pagina 94 · clicca per ingrandire
Pagina 94

Specifications

Figure 23. MPCBL0001 SBC Front Panel Dimensions – FC SKU (Screws and LEDs)

Page 95 of the Intel MPCBL0001 user manual — Specifications
Pagina 95 · clicca per ingrandire
Pagina 95

Specifications

Figure 24. MPCBL0001 SBC Front Panel Dimensions – Non FC SKU (PMC and Connectors)

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 95 Technical Product Specification

Page 96 of the Intel MPCBL0001 user manual — Specifications
Pagina 96 · clicca per ingrandire
Pagina 96

Specifications

Figure 25. MPCBL0001 SBC Front Panel Dimensions – Non-FC SKU (Screws and LED)

Page 138 of the Intel MPCBL0001 user manual — Figure 29. Power vs. Flow Rate
Pagina 138 · clicca per ingrandire
Pagina 138

Thermals

Thermals 12

The pressure drop curves versus the flow rate in Figure 29 represents flow impedance of the slot This information is provided in accordance with Section 5 of the PICMG 3.0 Specification. It will aid the system integrator in using the MPCBL0001 SBC in various AdvancedTCA shelves.

Figure 29. Power vs. Flow Rate

Intel MPCBL0001 — Figure 29. Power vs. Flow Rate diagram (page 138)
Fig. 7 · Figure 29. Power vs. Flow Rate
Page 147 of the Intel MPCBL0001 user manual — 17.7 Australia, New Zealand
Pagina 147 · clicca per ingrandire
Pagina 147

Agency Information—Class A

17.5 Japan VCCI Class A

Intel MPCBL0001 — Agency Information—Class A diagram (page 147)
Fig. 8 · Agency Information—Class A

17.6 Korean Class A

Intel MPCBL0001 — 17.6 Korean Class A diagram (page 147)
Fig. 9 · 17.6 Korean Class A

17.7 Australia, New Zealand

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 147 Technical Product Specification

Page 150 of the Intel MPCBL0001 user manual — 18.6 Australia, New Zealand
Pagina 150 · clicca per ingrandire
Pagina 150

Agency Information—Class B

18.5 Korean Class B

Intel MPCBL0001 — Agency Information—Class B diagram (page 150)
Fig. 10 · Agency Information—Class B

18.6 Australia, New Zealand

Page 152 of the Intel MPCBL0001 user manual — 19.1 Mesures de Sécurité
Pagina 152 · clicca per ingrandire
Pagina 152

Safety Warnings

Caution: System environmental requirements: Components such as Processor Boards, Ethernet Switches, etc., are designed to operate with external airflow. Components can be destroyed if they are operated without external airflow. External airflow is normally provided by chassis fans when components are installed in compatible chassis. Never restrict the airflow through the unit's fan or vents. Filler panels or air management boards must be installed in unused chassis slots. Environmental specifications for specific products may differ. Refer to product user manuals for airflow requirements and other environmental specifications.

Caution: Lithium batteries. There is a danger of explosion if a battery is incorrectly replaced or handled. Do not disassemble or recharge the battery. Do not dispose of the battery in fire. When the battery is replaced, the same type (CR2032) or an equivalent type recommended by the manufacturer must be used. Used batteries must be disposed of according to the manufacturer's instructions.

19.1 Mesures de Sécurité

Veuillez suivre les mesures de sécurité suivantes pour éviter tout accident corporel et ne pas endommager ce produit ou tout autre produit lui étant connecté. Pour éviter tout danger, veillez à utiliser le produit conformément aux spécifications mentionnées.

Lisez toutes les informations de sécurité fournies dans les manuels de l'utilisateur des produits composants et veillez à bien comprendre les mesures associées aux symboles de sécurité, aux avertissements écrits et aux mises en garde avant d'accéder à certains éléments ou emplacements de l'unité. Conservez ce document comme outil de référence.

Page 154 of the Intel MPCBL0001 user manual — 19.2 Sicherheitshinweise
Pagina 154 · clicca per ingrandire
Pagina 154

Safety Warnings

ventilateur ou les conduits de l'unité. Des boucliers ou des panneaux de gestion de l'air doivent être installés dans les connecteurs inutilisés du châssis. Les spécifications environnementales peuvent varier d'un produit à un autre. Veuillez-vous reporter au manuel de l'utilisateur pour déterminer les exigences en matière de flux d'air et d'autres spécifications environnementales.

Attention : les batteries au lithium. Celles-ci peuvent exploser si elles sont incorrectement remplacées ou manipulées. Veillez à ne pas désassembler ni à recharger la batterie. Veillez à ne pas jeter la batterie au feu. Lors du remplacement de la batterie, utilisez le même type de batterie (CR2032) ou un type équivalent recommandé par le fabricant. Les batteries usagées doivent être mises au rebut conformément aux instructions du fabricant.

19.2 Sicherheitshinweise

Lesen Sie bitte die folgenden Sicherheitshinweise, um Verletzungen und Beschädigungen dieses Produkts oder der angeschlossenen Produkte zu verhindern. Verwenden Sie das Produkt nur gemäß den Anweisungen, um mögliche Gefahren zu vermeiden.

Lesen Sie alle Sicherheitsinformationen in den Benutzerhandbüchern der zu dem Produkt gehörenden Komponenten und machen Sie sich mit den Hinweisen zu den Sicherheitssymbolen, schriftlichen Warnungen und Vorsichtsmaßnahmen vertraut, ehe Sie Teile oder Stellen des Geräts anfassen. Bewahren Sie dieses Dokument gut auf, um später darin nachlesen zu können.

SICHERHEITSWARNUNG FÜR WECHSELSTROM UND/ODER GLEICHSTROM: Die Stromversorgung des Gerätes wird über das Wechselstrom- und/oder Gleichstromkabel unterbrochen und muss daher jederzeit leicht zugänglich sein. Zusätzliche Ein-/Aus-Schalter für Wechselstrom und/oder Gleichstrom und/oder Leistungsschalter dienen lediglich der Steuerung der Stromversorgung (NICHT ABER DER UNTERBRECHUNG DER STROMVERSORGUNG).

Wechselstromsysteme: Verwenden Sie nur ein Stromkabel mit geerdetem Stecker und verbinden Sie dieses immer nur mit einer geerdeten Steckdose. Jedes Stromkabel muss an einen eigenen Stromkreis angeschlossen werden.

Gleichstromsysteme: Dieses Gerät basiert auf dem im Gebäude installierten Schutz vor Kurzschlüssen (Netzüberlastung). Stellen Sie sicher, dass für alle stromführenden Leiter eine zertifizierte Sicherung oder ein Leistungsschalter mit nicht mehr als 72V Gleichstrom, 15A verwendet wird. Für Geräte, die ständig angeschlossen sind, sollte in der Gebäudeverkabelung ein leicht zugänglicher Trennschalter installiert werden. Für eine permanente Verbindung verwenden Sie Kupferdraht der im Benutzerhandbuch des Systems angegebenen Stärke.

Page 156 of the Intel MPCBL0001 user manual — 19.3 Norme di Sicurezza
Pagina 156 · clicca per ingrandire
Pagina 156

Safety Warnings

19.3 Norme di Sicurezza

Leggere le norme seguenti per prevenire lesioni personali ed evitare di danneggiare questo prodotto o altri a cui è collegato. Per evitare qualsiasi pericolo potenziale, usare il prodotto unicamente come indicato.

Leggere tutte le informazioni sulla sicurezza fornite nella guida per l'utente relativa al componente e comprendere le norme associate ai simboli di pericolo, agli avvisi scritti e alle precauzioni da adottare prima di accedere a componenti o aree dell'unità. Custodire il presente documento per usi futuri.

AVVISO DI SICUREZZA RELATIVO ALL'ALIMENTAZIONE IN C.A. E/O C.C. Il cavo di alimentazione in c.a. e/o c.c. rappresenta il dispositivo principale per interrompere l'alimentazione in c.a. e/o c.c. dell'unità e deve sempre essere facilmente accessibile. Gli interruttori di accensione/spegnimento ausiliari per l'alimentazione in c.a. e/o c.c. hanno l'unico scopo di controllare l'alimentazione (NON INTERROMPONO L'ALIMENTAZIONE PRINCIPALE).

Per i sistemi CA, usare solo un cavo di alimentazione con una spina provvista di una messa a terra e collegarsi sempre a prese provviste di una messa a terra. Ogni cavo di alimentazione deve essere collegato ad un circuito derivato dedicato.

Per i sistemi CC, la presente unità può usufruire dell'eventuale installazione integrata nell'edificio per la protezione contro i cortocircuiti (sovratensione). Assicurarsi della presenza di un fusibile o di un circuito derivato non superiore a 72 V c.c., 15 A, certificato e conforme alla normativa in vigore, in tutti i conduttori portanti. Per gli apparecchi collegati in modo permanente, è necessario inserire nel circuito dell'edificio un interruttore ad accesso immediato. Per i collegamenti permanenti, usare il filo di rame del diametro specificato nella guida per l'utente relativa al sistema.

Il materiale fornito comprende un perno per il collegamento della messa a terra. Assicurare il collegamento della messa a terra prima di alimentare l'unità o prima di collegarla alle periferiche e non scollegare mai la messa a terra quando l'unità è alimentata o collegata a periferiche.

Per ridurre il rischio di scariche elettriche da parte della linea telefonica o dalla rete Ethernet*, collegare l'unità all'alimentazione principale prima di effettuare tale collegamento. Rimuovere i collegamenti prima di togliere l'alimentazione principale all'unità.

Page 157 of the Intel MPCBL0001 user manual — Safety Warnings
Pagina 157 · clicca per ingrandire
Pagina 157

Safety Warnings

NORME DI SICUREZZA PER LE UNITÀ MONTATE IN UN RACK. Questa unità può essere alloggiata in modo permanente in un rack. Il montaggio in rack deve essere conforme ai requisiti di resistenza fisica delle norme NEBS GR-63-CORE e NEBS GR 487.Prima di installare o rimuovere l'unità da un rack, rimuovere tutte le fonti di alimentazione e i collegamenti esterni.

Prima di effettuare il montaggio, è possibile ridurre il peso complessivo del sistema togliendo tutte le apparecchiature sostituibili a caldo. Montare il sistema in modo da garantire una distribuzione uniforme del peso nel rack. Una distribuzione irregolare del peso può essere pericolosa. Avvitare fino in fondo tutti i bulloni durante l'installazione dell'unità in un rack.

Avvertenza: evitare sovraccarichi elettrici, calore diretto, scosse e possibili cause di incendio. Collegare il sistema solo ad una rete elettrica la cui tensione nominale corrisponda al valore indicato nella guida per l'utente. Non collegarlo a fonti di alimentazione con valori di tensione esterne a quanto specificato per il sistema. Per ulteriori informazioni sul corretto collegamento, consultare la guida per l'utente del prodotto.

Attenzione: rispettare i requisiti ambientali del sistema. I componenti come le schede di processore, i commutatori Ethernet, ecc., sono progettati per funzionare in presenza di un flusso di aria proveniente dall'esterno, in assenza del quale rischiano di danneggiarsi irrimediabilmente. In genere, il flusso di aria esterno viene generato da appositi ventilatori installati contemporaneamente ai componenti nello chassis compatibile. Non ostacolare mai il flusso di aria convogliato dal ventilatore e dai condotti dell'unità. I pannelli di copertura o le schede per il controllo dell'aria devono essere installati negli alloggiamenti vuoti dello chassis. I requisiti ambientali possono variare a seconda del prodotto. Per ulteriori informazioni sui requisiti del flusso di aria e sugli altri requisiti ambientali, consultare la guida per l'utente del prodotto.

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 157 Technical Product Specification

Page 159 of the Intel MPCBL0001 user manual — Reference Documents
Pagina 159 · clicca per ingrandire
Pagina 159

Reference Documents

  • Low Pin Count (LPC) Interface Specification ( <a href="http://developer.intel.com/design/chipsets/" rel="nofollow noopener" target="_blank">http://developer.intel.com/design/chipsets/</a> industry/lpc.htm )
  • Intel ® Boot Agent. ( <a href="http://www.intel.com/support/network/adapter/pro100/bootagent/" rel="nofollow noopener" target="_blank">http://www.intel.com/support/network/adapter/pro100/bootagent/</a> manual.htm )
  • Intel’s AdvancedTCA product line <a href="http://developer.intel.com/technology/atca/" rel="nofollow noopener" target="_blank">http://developer.intel.com/technology/atca/</a>
Page 160 of the Intel MPCBL0001 user manual — List of Supported Commands (IPMI v1.5 and PICMG 3.0)
Pagina 160 · clicca per ingrandire
Pagina 160

List of Supported Commands (IPMI v1.5 and PICMG 3.0)

List of Supported Commands (IPMI v1.5 and PICMG 3.0) B

Table 97. IPMI 1.5 Supported Commands (Sheet 1 of 3)

Intel MPCBL0001 — List of Supported Commands (IPMI v1.5 and PICMG 3.0) diagram (page 160)
Fig. 11 · List of Supported Commands (IPMI v1.5 and PICMG 3.0)

Intel NetStructure® MPCBL0001 High Performance Single Board Computer 163 Technical Product Specification

Page 161 of the Intel MPCBL0001 user manual — List of Supported Commands (IPMI v1.5 and PICMG 3.0)
Pagina 161 · clicca per ingrandire
Pagina 161

List of Supported Commands (IPMI v1.5 and PICMG 3.0)

Table 97. IPMI 1.5 Supported Commands (Sheet 2 of 3)

Intel MPCBL0001 — List of Supported Commands (IPMI v1.5 and PICMG 3.0) diagram (page 161)
Fig. 12 · List of Supported Commands (IPMI v1.5 and PICMG 3.0)
Page 163 of the Intel MPCBL0001 user manual — List of Supported Commands (IPMI v1.5 and PICMG 3.0)
Pagina 163 · clicca per ingrandire
Pagina 163

List of Supported Commands (IPMI v1.5 and PICMG 3.0)

Fai una domanda su Intel MPCBL0001

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Intel MPCBL0001

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Intel MPCBL0001 manuale in PDF

166 pagine·1.5 MB·Computer portatile·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…