In tel ® Serv er Board S2600JF T echnical Product Specification Intel order number G 31608 -014 Revision 2.3 February 201 4.
Revision H istory Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 ii Revision History Date Revision Number Modifications December, 2011 1.0 Initial release. February, 2012 1.1 Add ed BMC sensor table and features. May, 2012 1.
Intel® Server Board S 2600JF TPS Disclaimers Revision 2.3 Intel order number G31608- 014 iii Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECT ION W ITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OT HERW ISE, TO ANY INTELLECTUAL PROPERTY RIGH TS IS GRANTED BY THIS DOCUMENT.
Table of Co ntents Intel ® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 iv Ta ble of Co ntents 1. Introduction ..................................................................................................................
Intel ® Server Board S2600JF TPS Table of Conten ts Revision 2.3 Intel order number G31608- 014 v 3.5.2 Quad Small For m-factor Pluggable (QSFP) Connector ........................................ 33 3.6 Integrated Baseboard Management Cont roller Overview .
Table of Co ntents Intel ® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 vi 4.12 BMC Basi c and Advanced Management Fea tures ............................................... 57 4.12.1 Enabling Adv anced Manageability Features .
Intel ® Server Board S2600JF TPS Table of Conten ts Revision 2.3 Intel order number G31608- 014 vii 7.2.1 Intel ® Remote M anagement Module 4 (Intel ® RMM 4 Lite) Connector .................. 130 7.2.2 IPMB H eader .................................
Table of Co ntents Intel ® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 viii 10.2.2 Standby Output .................................................................................................. 154 10.2.3 Voltage Regula tion .
Intel ® Server Board S2600JF TPS List of Figu res Revision 2.3 Intel order nu mber G31608- 014 ix List of Figures Figure 1. Intel ® Server Board S2600 JF (InfiniBand* SKU ) ........................................................... 3 Figure 2. Intel ® Server Board S2600 JF Components .
List of F igures Intel ® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 x Figure 40. Serv er Management Screen .................................................................................. 107 Figure 41. Consol e Redirection Screen .
Intel ® Server Board S2600JF TPS List of Tables Revision 2.3 Intel order number G31608- 014 xi List of Tables Table 1. Intel ® Server Board S2600 JF Feature Se t ..................................................................... 3 Table 2. Intel ® Server Board S2600 JF Features .
List of Tables In tel ® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 xii Table 40. Setup U tility – UEFI Networ k Stack Configuration Sc reen Fields ............................... 96 Table 41. Setup U tility – UEFI Option R OM Configuration Sc reen Fields .
Intel ® Server Board S2600JF TPS List of Tables Revision 2.3 Intel order number G31608- 014 xiii Table 81. PCI Ex press* Clock Source by Slot ......................................................................... 142 Table 82. VGA Ex ternal Video Connector (J4A1) .
Intel order n umber G31608 -014 Revision 2.3 xiv <This page is intentionally left blank .>.
Intel® Server Board S 2600JF TPS Introduction Revision 2.3 Intel order number G31608- 014 1 1. Intr oduction The Intel ® Server Board S2600JF is a hal f -width, dual-soc ket server board using the I.
Introduction Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 2 1.2 Server Board Use Disclai mer Intel Corpora tion server boards con tain a number o f high- density VLSI (Very Large Scale Integration) and pow er delivery components that need adequate airflow to cool.
Intel® Server Board S 2600JF TPS Server Board O verview Revision 2.3 Intel order number G31608- 014 3 2. Serv er Boar d Overview The Intel ® Server Board S2600JF is a monolithic printed circuit board (PC B) with features designed to suppor t the high performance and high density computin g markets.
Server Board Overview Intel ® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 4 Feature Description External I/O Connections DB -15 Vid eo connectors Two RJ-45 Network In terfaces for 10/100/1000 LAN One stacked two- po rt USB 2.
Intel® Server Board S 2600JF TPS Server Board O verview Revision 2.3 Intel order number G31608- 01 4 5 2.1 Server Board Conne ctor and Component Layout The follow ing illustration provides a general overview o f the server board, identi fying key feature and component locations.
Server Board O verview Intel ® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 6 2.1.1 Board Rear Connector Placement The Intel ® Server Board S2600JF has the follow ing board rear connecto r placement.
Intel® Server Board S 2600JF TPS Server Board O verview Revision 2.3 Intel order number G31608- 014 7 2.1.2 Server Board Mechanical Drawings The follow ing figure is a mechanical drawing for the Intel ® Server Board S 2600JF.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 8 3. Pr oduct Architectur e Overview The Intel ® Server Board S2600JF is a purpose-b uilt, rack-optimized serv er board used in a hi gh- density rack sy stem.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 9 Figure 5. Intel ® Server Bo ard S2600JF Functio nal Block Di agram.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 10 3.2 Processor Support The server board incl udes two Soc ket-R (LGA 2011) processo r so.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 11 Figure 7. Processor Socket ILM Variations The square ILM has a 90.5 x 90.5 mm heat sin k mounting hole pattern and is used on the In tel ® Server Board S2600 JF.
Product Arc hitecture Over view Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 12 Table 3 . M ixed Processor Configurations Error Severity System Action Processor family not identical Fatal The BIOS detects the error condition and responds as follows: Logs the error into the system event log (SEL).
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order nu mber G31608- 014 13 3.3 Processor Functio n Overview With the release o f the Intel ® Xeon ® processor E5 .
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 14 PCI express* Ato mic operation, x16 Non- Transparent Bridge (NTB) (Intel ® Xeon ® processor E5 -2600V2 on ly) Intel ® 64 OS Gui de Intel ® 64 Secure Key 3.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 15 Independent channel mode or loc kstep mode. Data burst length o f eight cycles f or all me mory organization modes. Memory DDR3 data trans f er rates of 80 0, 1066, 1333, 1600, and 1867 M T/s.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 16 3.3.2.1 Suppor ted Memory Table 4. Color Defin ition Supported and Validated Supported but not Validate TBD Table 5 .
Intel® Server Board S 2600JF TPS Product Architecture Over view Revision 2.3 Intel order number G31608- 014 17 Table 7. LRDIMM Support Guidelines Ranks Per DIMM and Data Width 1 Memory Capacity Per DIMM 2 Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and DIMM Per Channel (DPC) 3,4,5 1 Slot per Channel 1DPC 1.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 18 Table 8. Intel ® Server Boa rd S2600JF DIM M Nomenclature Processor Socket 1 Processor.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 19 If Display Logo is disabled, the BIOS displays the total syste m memory on the dia gnostic screen at the end o f POST. This total is the same as the a mount described by the first bullet above.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 20 DIMM slot location across Channel 0 and Channel 1 and across Channel 2 and Channe l 3 must be populated the same .
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 21 The follow ing sub-sections describe the server board features that are dir ectly supported by the processor IIO modul e. These include the Riser Card Slots, Ne twork Interface , and connectors for the optional I/O modules and SAS M odule.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -0 14 Revision 2.3 22 Table 9. CPU1 and C PU2 PCIe Con nectivity CPU Port IOU Width Connection CPU1 DMI2 IOU.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 23 Figure 12 . PCIe Riser for Slot 1 1U Riser for Slo t 2 with one PCIe slo t – 2 sets o f x8 signals routed to an x16 PCIe Sl ot (eight lanes for IOM Carrier).
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 24 Intel ® Xeon Phi ™ Coprocessor Ca rd – System Configuration Re quirements For best.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 25 System Managemen t Bus (SMBus*) Speci fication, Version 2.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31 608-014 Revision 2.3 26 3.4.3 Universal Serial Bus (USB) There are 14 US B 2.0 ports avai lable from Intel ® C600 PCH . All ports are high-speed, full-speed and low-speed capable.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 27 Table 11 . Intel ® RAID C60 0 Storage Upgrade K ey Op tions for S2600JF Intel ® RAID C6.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 28 The Intel ® C600 PCH su pports LPC DMA , which is simi lar to ISA DMA , t hr ough the PCH’s DM A controller. LPC DM A is handled through the use o f the LDRQ# lines from peripherals and special encoding on LAD [3:0] from the host.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 29 3.4.15 Intel ® Virtualization Technology for Direct I/O (Intel ® VT - d) The Intel ® Virtualizatio n Technology is desi gned to support multiple so ftware environmen ts sharing same ha rdware resources.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 30 Processor Presen t Indicator: The Intel ® C600 PCH looks for the processor to fetch the first instruction after reset. If the processo r does not fetch the first instruction, the PCH reboots the syste m.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 31 The NIC support s the normal RJ-45 LINK/Ac tivity speed LEDs as well as the Preset ID function . These LEDs a re powered from a Standby voltage rail.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 32 3.4.20.3 Wake- On -LAN WOL is supported on the Intel ® i350 LAN controll er for all suppor ted Sleep states. 3.4.20.4 LAN Connector Orderin g The Intel ® i350 NIC is co nnected to independent RJ-45 ports for NIC 1 and NIC 2 .
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 33 3.5.1 Device Interfaces Followi ng is a list o f major interfaces o f Mellanox* ConnectX-3* chip: Clock and Rese t signals: Include core cloc k input and chip reset si gnals.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 34 The module mee ts ESD requirements given in EN61000-4-2, criterion B test specification.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 35 Figure 19 . Integrated BMC F unctional Block Diagr am The Integrated BM C is provided by an embedded ARM9 controller and a ssociated peripheral functionality tha t is required for IPM I -based server management .
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 36 Serial general-purpo se I/O Ports (80 i n and 80 out). Three UARTs. Platform Envi ronmental Control Inte rface (PECI). Six general-purpo se timers.
Intel® Server Board S 2600JF TPS Product Architecture Overview Revision 2.3 Intel order number G31608- 014 37 DDR -2/3 memory interfa ce supports up to 256M bytes of memory Supports all di sp.
Product Arc hitecture Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 38 USB 1.1 / USB 2 .0 interface for PS2 to USB bridgin g, remote keyboard, video, and mouse. Hardware Base d Video Compression an d Redirection Log ic .
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 39 4. Pla tform Manag ement Functional Overvie w Platform mana gement functional.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 40 BMC self-test: The BMC performs initial ization and runtime sel f-tests and makes results avai lable to external entities. See also the Intell igent Platform Manage ment Interface Specification Seco nd Generation v2.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 41 Power fault analy sis. Intel ® Light-Guide d Diagnostics. Address Resolution Protocol (ARP): The BM C sends and responds to ARPs (supported on emb edded NICs).
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 42 Provisi oning and inventory enhancements: o Signed Firmw are (improved security). o Inventory data /system information export (partial SM BIOS table).
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 43 4.2 Advanced Configur ation and Power Interface (ACPI) The server board supports the follow ing ACPI states. Tabl e 16 . ACPI Power States State Supported Description S0 Yes W orki ng.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 44 4.4 BMC Internal Timestam p Clock The BM C maintains an internal times tamp clock that is u sed by various B MC subsystems, for example, for ti me stamping SEL entries.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 45 4.6.1 Channel Management Every messag ing in terface is assigned an IPMI channel ID by IPMI 2.0. Commands are provided to confi gure each channel for priv ilege levels and access modes .
Platform Manage ment Function al Ove rview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 46 Table 18 . Defau lt User Values Users User name Password Status Default Privilege Characteristics User 1 [Null] [Null] Disabled Admin Password can be changed.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 47 LAN1 or Intel ® Dedicated Server Management NIC, they are not counted as LAN1 or Intel ® Dedicated Server Management NIC IPMI channel sessions but are counted as IPMI sessions in limit calculations.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 48 4.6.4.3 Concur rent Server Management Use of Multiple Ether net Controllers .
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 49 There are tw o variants of automatic IP Address Sou rce configuration vs.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 50 1h, static addres s (manually con fig ured): Suppo rted on all management N ICs. This is the BMC’ s def ault val ue. 2h, address obtaine d by BMC runni ng DHCP: Supported on all management NICs .
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 51 unreachable val ue. The BMC returns a 0xCC (Invalid Da ta Field in Request) completion code f or de fault gateway addresses outside its subnet.
Platform Manag ement Func tional Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 52 4.6.8 Address Resolution Protocol (ARP) The BM C can receive and respond to AR P requests on BM C NICs. Gratuitous ARPs a re supported, and di sabled by default.
Intel® Server Board S 2600JF TPS Platform Manage ment Fun ctional Overview Revision 2.3 Intel order number G31608- 014 53 4.6.10 Secure Shell (SSH) Secure Shell (SSH ) connections are suppo rted for one SM ASH-CLP session to the BM C. 4.6.11 Serial-over-LAN (SOL 2.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31 608-014 Revision 2.3 54 Rese t OEM action Al erts The “Diagnostic interrupt” action is no t supported.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 55 4.7 System Event Log (SEL) The BM C implements the system ev ent log as speci f ied in the Intelligent P latform Management Interface Specificatio n, Version 2.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 56 4.8 Sensor Data Record (SDR) Repository The BM C implements the sensor data record (SDR ) repository as speci fied in the Intelligent Platform Manage ment Interface Specifica tion, Version 2.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 57 a. Receiving a Chassi s Control command to pul se the diagnostic inte rrupt. This command does not cause an ev ent to be logged in the SEL.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 58 4.12.1 Enabling Advanced Manageability Features The Advanced management features ar e to be deliv ered as part of the B MC FW image.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 59 4.12.1.2 Remote Console The Remote Consol e is the redirected screen , key board, and mouse of the remote host sy stem.
Platform Manage ment Function al Over view Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 60 4.12.1.7 Usage When the serv er is powered up, the remo te KVM session displ ays the complete BI O S boot process.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 61 If either a virtual floppy devi ce is remotely attached durin g syste m boot, the vi rtual floppy is presented as a bootable devi ce.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 62 The embedded w eb user interface suppor ts strong security (authentication, enc ryption, and firewall support) because it enables re mote server confi guration and control .
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 63 4.12.5 Local Directory Authentication Protocol (LDAP) The Lightw eight Directory Access Pro tocol (LDAP) is an appl ication protocol suppo rted by the Integrated BM C for the purpose of au thentication and autho rization.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 64 Static Closed Loop Thermal Thrott ling (Static-CLTT ): CLTT control re gisters are configured by B IOS MRC during P OST.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 65 4.12.8 Node Power On/Off Control The BM C on each node monitors its fans and temperature for a critical failure. W hen a critical failure occurs, the node will be powered down by the BM C.
Platform Manag ement Func tional Overview Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 66 4.14 Management Engin e (ME) 4.14.1 Overvi ew The Intel ® Server Platfor m Services (SPS) is a set of manageabil ity services provi ded by the firmware executi ng on an embedded ARC control ler within the IOH.
Intel® Server Board S 2600JF TPS Platform Manage ment Fun ctional Overview Revision 2.3 Intel order number G31608- 014 67 Figure 20 . Management E ngine Distribution M odel 4.
Platform Manage ment Function al Overview Intel® Server Board S 2600JF TPS Intel order n umber G31 608-014 Revision 2.3 68 BMC may be queried by the ME f or inlet tempe rature readings. 4.14.5 ME Power and Firmware Startup On Intel ® Server Board S 2600JF, the ME is on sta ndby pow er.
Intel® Server Board S 2600JF TPS Platform Manage ment Function al Overview Revision 2.3 Intel order number G31608- 014 69 4.15 Other Platfor m Management The platform suppo rts the follow ing sleep states, S1 and S5. W ithin S0, the pl atform supports additional low er power states, such as C1e and C6, for the CP U.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 70 5. BIOS Se tup Inte rface 5.1 HotKeys Supported during POST Certain HotKeys a re recognized duri ng POST.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 71 Instructions show ing hotkeys for going to Setup, goin g to pop- up Boot M enu, and starting Netw ork Boot 5.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 72 5.4.1.1 Setup Pa ge Layout The Setup pa ge layout is sectioned into functional areas. Each occupies a speci f ic area o f the screen and has dedicated functionali ty.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 73 5.4.1.2 Entering BIO S Setup To enter the B IOS Setup using a key board (or emul ated keyboard), press t he <F2> function key during boot time w hen the OEM or Intel ® logo is displ ayed.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 74 Key Option Description + Change Value The plus key on the keypad is used to change the value of the current menu item to the next value. This key scrolls through the values in the associated pick list without displaying the full list.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 75 The Help Tex t entry is the actual text that appears on the screen to acco mpany the item when the item is the one in focus (ac tive on the screen) .
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 76 Categories (Top Tabs) Second Level Screens Third Level Screens Server Management Screen (Tab) .
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 77 Table 30 . Setup Utility – Main Screen Fields Setup Item Options Help Text Comments Logged in as Information only. Displays password level that setup is running in: Administrator or User.
BIOS Setup Inte rfa ce Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 78 5.4.2.3 Advanced Screen (Tab) The Advanced screen provide s an access point to con f igure sev eral groups of options . On this screen, the use r can select the option group to be configured .
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 79 To access this screen from the M ain screen, select Adv anced > Processor Conf iguration . To move to anothe r screen, press the <Esc > key to return to the Advanced sc reen, then select the desired screen.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 80 Table 32 . Setu p Utility – Proces sor Configuration S creen Fields Setup Item Options Help Text Comments Processor ID Information only. Processor CPUID.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 81 Setup Item Options Help Text Comments Enhanced Intel SpeedStep ® Technology Enabled Disabled Enh.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 82 Setup Item Options Help Text Comments Intel ® Virtualization Technology for Directed I/O Enabled Disabled Enable/Disable Intel ® Virtualization Technology for Directed I/O (Intel ® VT - d) .
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 83 Setup Item Options Help Text Comments Extended ATR 0x03 0x01 Extended Timeout value for PCIe tuning. 0x03 = default timeout. 0x01 = extended timeout.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 84 When the user s elects a Pow er and Performance Poli cy in Setup, there is a list of complementary se ttings which are made. These can be indiv idually overridden after the pol icy setting has been selected and the profile se ttings performed.
Intel® Server Board S2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 85 BIOS Features Available Settings Performance Balanced Performance Balanced Power Power Set Fan Pro.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 86 Advanced Memory Config uration Total Memory <Total Physical Memory Installed in Syst em> E.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 87 Setup Item Options Comments Current Configuration Independent Channel Mirror Lockstep Displays on.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 88 5.4.2.7 Memo ry RAS and Performance Confi guration The Memory RAS and Performance Con figuration screen allows the user to cus tomize sev eral memory con f iguration op tions, such as w hether to use Memory M irr oring or M emory Sparing.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order nu mber G31608- 014 89 5.4.2.8 Mass S torage Controller Configura tion The Mass Stora ge Controller Configuration screen allow s the user to configure the M ass Storage controll ers that are integrated into the serv er board on which the BIOS is executing.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 90 Setup Item Options Help Text Comments AHCI HDD Staggered Spin- Up Disabled Enabled If enabled for the AHCI Capable SATA controller, Staggered Spin- Up will be performed on drives attached to it.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 91 Advanced PCI Configura tion Maximize Memory b elow 4GB Enabled / Dis abled Memory Mapped I/O abo .
BIOS Setup Inte rface Intel® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 92 Setup Item Options Help Text Comments Onboard Video Enabled Disabled On -board video controller. Warning : System video is completely disabled if this option is disabled and an add- in video adapter is not installed.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 93 5.4.2.10 NIC Configuration The NIC Con f iguration screen allows the use r to configure on-board NIC port 1 and port 2.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 94 Table 39 . Setu p Utility – N IC Configuration Scr een Fields Setup Item Options Help Text Comments W ake on LAN Enabled Disabled Enable or disable PCI PME function for Wake on LAN capability from LAN adapters.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 95 Setup Item Options Help Text Comments IO Module 1 Type IO Nodule 2 Type None Intel ® I350 Quad-P.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 96 Setup Item Options Help Text Comments NIC1 Port1 PXE NIC1 Port2 PXE NIC2 Port1 PXE NIC2 Port2 PXE IOM1 Port1 PXE IOM1 Port2 PXE Enabled Disabled Enable/disable On-board / IOM NIC Port PXE Boot.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Intel order number G31608- 014 97 5.4.2.12 UEFI Option ROM Con trol This screen all ows the user to confi gure UEFI Option ROM Settin gs.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 98 Table 42 . i350 N IC Configuratio n Screen Field s Setup Item Options Help Text Comments NIC Configuration Submenu Click to configure the network device port.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2 .3 Intel order n umber G31608 -014 99 Figure 33 . IIO PCI Express Lane Partitioning Processor PCI e Link Speed ► Socket 0 PCIe Link Sp eed ► Socke t 1 PCIe Link Sp eed Figure 34 . Processor PC Ie Link Speed Con figurati on Screen Table 43 .
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 100 By entering the sub menu screen wi ll allow the user to configure PC Ie port link speed in detail. Socket X PCI e Ports Link Sp eed Socket X, DMI Gen2 (5G T/s) / Gen1 (2.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 101 Table 45 . Setu p Utility – Serial Po rts Configuration Screen Fields Setup Item Options Help Text Serial A Enable Enabled Disabled Enable or disable Serial port A.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 102 Setup Item Options Help Text Comments USB Controller Enabled Disabled [Enabled] – All on-board USB controllers are turned on and accessible by the OS.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 103 Advanced System Acous tic and Perfo rmance Configur ation Set Throttling Mode Auto / DCLTT / SC.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 104 Setup Item Options Help Text Comments Set Fan Profile Performance Acoustic [Performance] – Fan control provides primary system cooling before attempting to throttle memory.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 105 Main Advanced Security Server Manag ement Boot Optio ns Boot Manag er Administrator Password St.
BIOS Setup Inte rface Intel® Server Board S 2600 JF TPS Intel order n umber G31608 -014 Revision 2.3 106 Setup Item Options Help Text Comments Power ON Password Enabled Disabled Enable Power On Password support. If enabled, password entry is required in order to boot the system.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 107 Main Advanced Security Server Manag ement Boot Optio ns Boot Manag er Assert NMI on SERR Enable.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 108 Setup Item Options Help Text Comments PCIe AER Support Enabled Disabled Enable or Disable PCIe AER (Advanced Error Reporting). PC Ie AER error will be masked after PCIe AER is disabled.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 109 Setup Item Options Help Text Comments Plug and Play BMC Detection Enabled Disabled If enabled, the BMC is detectable by OS es that support plug and play loading of an IPMI driver.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 110 Table 50 . Setu p Utility – C onsole Redirection Sc reen Fields Setup Item Options Help Text Console Redirection Disabled Serial Port A Console redirection allows a serial port to be used for server management tasks.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 111 Server Manag ement System Info rmation Board Part Number <Part Number display > Board Ser.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 112 To access this screen from the M ain screen, select Server Managemen t > Sy stem Information. To move to another screen , press the <Esc > key to return to the Serv er Management screen , then select the desired screen.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 113 Table 52 . Setu p Utility – B MC L AN Configuration Screen Fields Setup Item Options Help Text Comments IP source Static Dynamic Select BMC IP source.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 114 The first boot device in the specified Boo t Order that is presen t and is bootable durin g POS.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 115 Table 53 . Boot Op tions Screen Fields Setup Item Options Help Text Comments Boot Timeout 0-65535 The number of seconds the BIOS should pause at the end of POST to allow the user to press the [F2] key for entering the BIOS Setup utility.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 116 Setup Item Options Help Text Comments Reset Static Boot Order Yes No Action [Yes] – Take snapshot of current boot order to save as Static Boot Order Template.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 117 To access this screen from the M ain screen, select Boot Opt ions > Hard Disk Order . To move to another screen , press the <Esc> key to return to the Boo t Options screen, then select the desired screen.
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 118 Table 56 . Boot Op tion – F loppy Order Scre en Fields Setup Item Options Help Text Floppy Disk #1 Available Legacy devices for this Device group.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 119 Boot Optio ns BEV Device Or der BEV Device #1 <Available Hard Disk devices> BEV Device #2 <Available Hard Disk devices> Figure 49 . BEV Device Order S creen Table 58 .
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31 608-014 Revision 2.3 120 Setup Item Options Help Text Comments Select File System Available File System Select the file system from the list. Choose the file system on which this boot path resides.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 121 Main Advanced Security Server Manag ement Boot Optio ns Boot Manag er Launch EFI Shell <Boot device #1> <Boot Option #2> <Boot Option #n> Figure 52 .
BIOS Setup Inte rface Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 122 Error Manag er Save&Exit ► View Even t Log ERROR CODE SEVERITY INSTANCE <Post Code> <Major/Minor> <Instance #>> <Description> 5224 Major N/A This is an example.
Intel® Server Board S 2600JF TPS BIOS Setup Interfac e Revision 2.3 Inte l order number G31608- 014 123 Table 63 . Setu p Utility – Sav e & Exit Screen Fields Setup Item Help Text Comments Save Changes and Exit Exit the BIOS Setup utility after saving changes.
Configuration Ju mpers Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 124 6. Con figur ation Jumpers The follow ing table provides a summary and description o f conf iguration , test, and debug jumpers on the Intel ® Serv er Board S2600JF.
Intel® Server Board S 2600JF TPS Configuration Jumpers Revision 2.3 Inte l order number G31608- 014 125 Table 64 . Serv er Board Ju mpers (J6B1, J1 E2, J1E3, J1E1, and J1D5) Jumper Name Jumper Positi.
Configuration Ju mpers Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 126 11. Plug in the compu te module bac k to t he chassis. Note: Normal BM C functionality is disabled with the Force BM C Update jumper set to the enabled position.
Intel® Server Board S 2600JF TPS Configuration Jumpers Revision 2.3 Inte l order number G31608- 014 127 6.3 Password Clear (J1 B6 ) The user sets thi s 3-pin jumper to clear the password.
Configuration Ju mpers Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 128 The BIOS star ts the recovery process by first loading and booting to the recovery image file ( RML.ROM ) on the root directory o f the recovery media (USB disk).
Intel® Server Board S 2600JF TPS Configuration Jumpers Revision 2.3 Inte l order number G31608- 014 129 1. Plug out the co mpute module from cha ssis. 2. Remove the air du ct. 3. Move jumper (J1D5 ) from the default opera ting position (coverin g pins 1 and 2) to the reset/clear position (covering pins 2 and 3 ).
Connector/Heade r Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 130 7. Connect or/Header L ocations and Pin-out 7.
Intel® Server Board S 2600JF TPS Connector/Heade r Locations an d Pin- out Revision 2.3 Inte l order number G31608- 014 131 Table 73 . Bridg e Board Co nnector (J1D1) Side Even Signal Side Odd Signal.
Connector/Heade r Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 132 7.3.1 Power Button The BIOS suppo rts a front control pan el power button. Pressi ng the power bu tton initiates a request that the Integrated BM C forwards to the ACPI power state machi nes in the chipse t.
Intel® Server Board S 2600JF TPS Connector/Heade r Locations an d Pin- out Revision 2.3 Inte l order number G31608- 014 133 Table 74 . Pow er LED Indicator Stat es State ACPI Power LED Power off No Off Power on No Solid on S5 Yes Off S1 Sleep Yes ~1 Hz blink S0 Yes Solid on 7.
Connector/Heade r Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 134 Table 75 . System Status LED Color State Criticality Description Green Solid on Ok Indic ates that the System Status is “Healthy” .
Intel® Server Board S 2600JF TPS Connector/Heade r Locations an d Pin- out Revision 2.3 Inte l order number G31608- 014 135 Color State Criticality Description correctable errors is crossed within the window 1 . Amber Solid on Critical, non- recoverable Fatal alarm – system has failed or shut down: 1.
Connector/Heade r Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 136 Riser Slot 1: Riser to support PCIe x 16 add-in card or GPGPU ca rd .
Intel® Server Board S 2600JF TPS Connector/Heade r Locations an d Pin- out Revision 2.3 Inte l order number G31608- 014 137 Pin Pin Name Description Pin Pin Name Description B37 GND A37 PERxN4 Rx Lan.
Connector/Heade r Locations an d Pin- o ut Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 138 Table 78 . PCI E xpress* x1 6 Riser Slot 2 Con nector ( J1A3) Pin Pin Name Description Pin Pin Name Description B1 12V 20W 3.
Intel® Server Board S 2600JF TPS Connector/Heade r Locations an d Pin- out Revision 2.3 Inte l order number G31608- 014 139 Pin Pin Name Description Pin Pin Name Description B44 GND A44 PERxP6 Rx Lan.
Connector/Heade r Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 140 Pin Pin Name Description Pin Pin Name Description B5 SMCLK A5 3.
Intel® Server Board S 2600JF TPS Connector/Heade r Locations an d Pin- out Revision 2.3 Inte l order number G31608- 014 141 Pin Pin Name Description Pin Pin Name Description B51 GND A51 PERxN8 Rx Lan.
Connector/Heade r Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 142 Table 81 . PCI Expr ess* Clock Sou rce by Slot PCI Express Clocks Source ac.
Intel® Server Board S 2600JF TPS Connector/Heade r Locations an d Pin- out Revision 2.3 Inte l order number G31608- 014 143 Table 83 . RJ -4 5 10/100/10 00 NIC Connector Pin -out (J A6 A1 and J A5 A 1) 7.4.4 SATA Connectors The server board p rovides one SA TA port connector named SATA-1 port (J6D1) on boa rd.
Connecto r/Header Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 144 7.4.6 Storage Upgrade Key Connector The server board p rovides one SA TA/SAS storage upgrade key connector (J6C 4) on board.
Intel® Server Board S 2600JF TPS Connector/Heade r Locations and Pin- out Revision 2.3 Inte l order number G31608- 014 145 Pin Signal Name Pin Signal Name 9 Key Pin 10 NC 7.4.9 QSFP for InfiniBand* The follow ing table details the pin-out of the QSFP connector (J2B1) found on the bac k edge of the server board .
Connector/Heade r Locations an d Pin- out Intel® Server Board S 2600JF TPS Intel order n umber G31 608-014 Revision 2.3 146 rate; this rate is selected by Intel and preset by th e Fan manufacturer . This is done to stop air recirculation betw een nodes.
Intel® Server Board S 2600JF TPS Intel® Light -Guided Diagn ostics Revision 2.3 Inte l order number G31608- 014 147 8. Intel ® Light-Guided Diagnos tics The Intel ® Server Board S2600JF has several on-board diagnostic LEDs to assist in troubleshooting board -level issues.
Intel® Light -Guided Diagn ostics Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 148 Table 93 . Netw ork Link/Activ ity LED LED Color Condition What It Means LAN – Link/Activity Green On LAN link/no access Green Blink LAN access Off Idle 8.
Intel® Server Board S 2600JF TPS Intel® Light -Guided Diagn ostics Revision 2.3 Inte l order number G31608- 014 149 Figure 57 . Rear Panel Diagn ostic LEDs (Block A).
Environmen tal Limits Speci fication Intel ® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 150 9. En vir onmental Limits Specifica tion Operation of the server board at conditions beyond those show n in the following table may cause permanen t damage to the sy stem.
Intel® Server Board S 2600JF TPS Environmen tal Limits Specificat ion Revision 2.3 Inte l order number G31608- 014 151 9.1.1 Set Throttling Mode This option is used to select the desired memory thermal thro ttling mechanism. Availab le settings includ e [Auto], [DCLTT], [SCLT T] and [SOLTT].
Environmen tal Limits Specificat ion Intel ® Server Board S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 152 9.1.6 Thermal Sensor Input for Fan Speed C ontrol The BM C uses various IPMI sensors as inputs to fan speed control. Some o f the sensors are actual physical sensors and some are “v irtual” sensors de rived from calculatio ns.
Intel® Server Board S 2600JF TPS Environmen tal Limits Specificat ion Revision 2.3 Inte l order number G31608- 014 153 The follow ing diagram illustrates the fan speed con trol structure.
Power Supp ly Specification Guide lines Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 154 10. Po wer Supply Specification Gui delin es This section prov ides power supply specification guidelines recom mended for prov iding the specified server platform with stable opera ting pow er req uiremen ts.
Intel® Server Board S 2600JF TPS Power Supp ly Specification Guide lines Revision 2.3 Inte l order number G31608- 014 155 10.2.3 Voltage Regulation The power suppl y output voltages stay w ithin the following vol tage limits when operating at steady state and dynamic loading conditi ons.
Power Supp ly Specification Gu idelines Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 156 10.2.8 Residual Voltage Immunity in Standby Mode The power supply is immune to any residu al voltage placed on its outputs (Typicall y a leakage voltage throu gh the system from standby output) up to 500mV.
Intel® Server Board S 2600JF TPS Power Supp ly Specifica tion Guidelines Revision 2.3 Inte l order number G31608- 014 157 Table 101 . R ipples and Noise +12V main +5VSB 120mVp-p 50mVp-p 10.2.15 Timing Re qu irement These are the ti ming requirements for the power suppl y operation.
Power Supp ly Specification Guide lines Intel® Server Board S 2600JF TPS Intel order n umber G31 608-014 Revision 2.3 158 Figure 59 . Turn On/Off Timin g (Power Supply Sign als) AC Input Vout PWOK 12.
Intel® Server Board S 2600JF TPS Appendix A: In tegration and Usag e Tips Revision 2.3 Inte l order number G31608- 014 159 Appendix A: Integration and Usage Tips When addin g or remov ing components or peripherals from the server boar d, AC power must be remov ed.
Appendix B : Integrated BMC Senso r Tables Intel® Ser ver Board S26 00JF TPS Intel order n umber G31608 -014 Revision 2.3 160 Appendix B: Integrated BMC Sensor Tables This appendix li sts the sensor .
Intel® Ser ver Board S26 00JF TPS Ap pendix B: Integrat ed BMC Sensor Table s Revision 2.3 Inte l order number G31608- 014 161 A: Auto-rearm M: Manual rearm I: Rearm by ini t agent Default Hy steresis The hysteresis set ting applies to all threshol ds of the sensor.
Appendix B : Integrated BMC Senso r Tables Intel® Server Board S 2600JF TPS 162 Intel order n umber G3 1608-014 Revision 2.3 Table 103 . BM C Sensor T able Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix B: Inte grated BMC Sensor Table s Revision 2.3 Intel order nu mber G31608- 014 163 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix B : Integrated BMC Senso r Tables Intel® Server Board S 2600JF TPS 164 Intel order n umber G31608 -014 Revision 2.3 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix B: Inte grated BMC Sensor Table s Revision 2.3 Intel order nu mber G31608- 014 165 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix B : Integrated BMC Senso r Tables Intel® Server Board S 2600JF TPS 166 Intel order n umber G31608 -014 Revision 2.3 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix B: Inte grated BMC Senso r Tables Revision 2.3 Intel order nu mber G31608- 014 167 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix B : Integrated BMC Senso r Tables Intel® Server Board S 2600JF TPS 168 Intel order n umber G31608 -014 Revision 2.3 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix B: Inte grated BMC Sensor Table s Revision 2.3 Intel order nu mber G31608- 014 169 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix B : Integrated BMC Senso r Tables Intel® Server Board S 2600JF TPS 170 Intel order n umber G31608 -014 Revision 2.3 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix B: Inte grated BMC Sensor Table s Revision 2.3 Intel order nu mber G31608- 014 171 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix B : Integrated BMC Sen sor Tables Intel® Server Board S 2600JF TPS 172 Intel order n umber G31608 -014 Revision 2.3 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix B: Inte grated BMC Sensor Table s Revision 2.3 Intel order nu mber G31608- 014 173 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix B : Integrated BMC Senso r Table s Intel® Server Board S 2600JF TPS 174 Intel order n umber G31608 -014 Revision 2.3 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix B: Inte grated BMC Sensor Table s Revision 2.3 Intel order nu mber G31608- 014 175 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Appendix B : Integrated BMC Senso r Tables Intel® Server Board S 2600JF TPS 17 6 Intel or der number G31 608-014 Revision 2.3 Full Sensor Name (Sensor name in SDR) Sensor # Platform Applicability Sensor Type Event/ Reading Type Event Offset Triggers Contrib.
Intel® Server Board S 2600JF TPS Appendix C: BIOS Sensors an d SEL Data Revision 2.3 Inte l order number G31608- 0 14 177 Appendix C: BIOS Sensors and SEL Data The BIOS ow ns a set of IPMI-compliant Sensors. These are actual ly divided in ow nership between BIOS P OST (GID = 01) and BI OS SMI Handler ( GID = 33).
Appendix C: BIOS Sensors an d SEL Data In tel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 178 Sensor Name Sensor Number Sensor Owner (GID) Sensor Type Event/Reading Type O.
Intel® Server Board S 2600JF TPS Appendix C: BIOS Sensors an d SEL Data Revision 2.3 Inte l order number G31608- 014 179 Sensor Name Sensor Number Sensor Owner (GID) Sensor Type Event/Reading Type Of.
Appendix C: BIOS Sensors an d SEL Data In tel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 180 Sensor Name Sensor Number Sensor Owner (GID) Sensor Type Event/Reading Type O.
Intel® Server Board S 2600JF TPS Appendix C: BIOS Sensors an d SEL Data Revision 2.3 Inte l order number G31608- 014 181 Sensor Name Sensor Number Sensor Owner (GID) Sensor Type Event/Reading Type Of.
Appendix C: BIOS Sensors an d SEL Data In tel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 182 Sensor Name Sensor Number Sensor Owner (GID) Sensor Type Event/Reading Type O.
Intel® Server Board S 2600JF TPS Appendix C: BIOS Sensors an d SEL Data Revision 2.3 Inte l order number G31608- 014 183 Sensor Name Sensor Number Sensor Owner (GID) Sensor Type Event/Reading Type Of.
Appendix D: Node Manager 2.0 IPMI Integrated Sen sors Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 184 Appendix D: Node Manager 2 .
Intel® Server Board S 2600JF TPS Appendix E: PO ST Code LE D Decoder Revision 2.3 Inte l order number G31608- 014 185 Appendix E: POS T Code LED Decoder During the sy stem boot process, the B IOS executes sev eral platform con f iguration p rocess es, each of whi ch is assigned a specific hex POST code numbe r.
Appendix E: PO ST Code LE D Decoder Inte l® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 186 In the followi ng example, the BIOS sends a value o f AC h to the diagnostic LED decoder. The LEDs are decoded as follows. Table 106 .
Intel® Server Board S 2600JF TPS Appendix E: PO ST Code LE D Decoder Revision 2.3 Inte l order number G31608- 014 187 Progress Code Description 0x33 CPU PEIM (Cache Init) 0x34 CPU PEIM (BSP Select) 0.
Appendix E: PO ST Code LE D Decoder Inte l® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 188 Progress Code Description 0x9D DXE USB enable 0xA1 DXE IDE begin 0xA2 DXE IDE re.
Intel® Server Board S 2600JF TPS Appendix E: PO ST Code LE D Decoder Revision 2.3 Inte l order number G31608- 014 189 Progress Code Description BIOS Recovery 0xF0 PEIM which detected forced Recovery .
Appendix F: V ideo POST Code E rrors Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 190 Appendix F: Video POST Code Erro rs The table below lists the supported POS T Error Codes, wi th a descriptive Error Message tex t for each.
Intel® Server Board S 2600JF TPS Appendix F: Video PO ST Code Errors Revision 2.3 Inte l order number G31608- 014 191 Error Code Error Message Response 0196 Processor model mismatch detected Fatal 01.
Appendix F: V ideo POST Code E rrors Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 192 Error Code Error Message Response 852C DIMM_E1 failed test/initialization Major .
Intel® Server Board S 2600JF TPS Appendix F: Video PO ST Code Errors Revision 2.3 Inte l order number G31608- 014 193 Error Code Error Message Response 8557 DIMM_H3 disabled Major 8558 DIMM_J1 disabl.
Appendix F: V ideo POST Code E rrors Intel® Server Boar d S2600JF TPS Intel order n umber G31608 -014 Revision 2.3 194 Error Code Error Message Response 85C1 DIMM_M1 failed test/initialization Major .
Intel® Server Board S 2600JF TPS Appendix F: Video PO ST Code Errors Revision 2.3 Inte l order number G31608- 014 195 Error Code Error Message Response 85EE DIMM_T2 encountered a Serial Presence Dete.
Glossary Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 196 Glossary This glossary contains important terms used in the precedin g chapters. For ease of use, numeric entries are listed first ( f or exampl e, 82460GX) w ith alpha entries foll owing (for example, AGP 4x).
Intel® Server Board S 2600JF TPS Glossary Revision 2.3 Inte l order number G31608- 014 197 Term Definition Hz Hertz (1 cycle/second) I 2 C Inter-Integrated Circuit Bus IA Intel ® Architecture IBF In.
Glossary Intel® Server Board S 2600JF TPS Intel order n umber G31608 -014 Revision 2.3 198 Term Definition PW M Pulse-Width Modulation QPI QuickPath Interconnect RAM Random Access Memory RASUM Reliab.
Intel ® Server Board S2600JF TPS Reference Doc uments Revision 2.3 Inte l order number G31608- 014 199 Reference Documents ACPI 3.0 : h ttp://www.acpi.i nf o/spec .htm IPMI 2.0 Data Center Manag ement Interface Specification v1.0 , May 1, 2008: www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Intel HNS2600JFF è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Intel HNS2600JFF - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Intel HNS2600JFF imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Intel HNS2600JFF ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Intel HNS2600JFF, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Intel HNS2600JFF.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Intel HNS2600JFF. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Intel HNS2600JFF insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.