System Installation Guide GS-SR195V 1U Rack Mount Server Intel ® Pentium Xeon Processor Serverboard Rev. 1.1.
2 GS-SR195V Rack Mount Server T able of Content Safety, Care and Regulatory Information ................................................ 4 Introduction .............................................................................................. 8 Contents Packages .
3 T able of Content Chapter 5 BIOS Setup .......................................................................... 2 8 Main ........................................................................................................... 3 0 Advanced .....
4 GS-SR195V Rack Mount Server Safety, Care and Regulatory Information Important safety information Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use.
5 Safety Information * T o reduce the risk of fire, use only No. 26 A WG or larger telecommunications line cord. * Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.
6 GS-SR195V Rack Mount Server Y our telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.
7 Safety Information NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading.
8 GS-SR195V Rack Mount Server ; Chassis ; GA-9IVDPC Motherboard (Installed) ; Power Supply (Installed) ; GC-REIU (PCI-E Riser Card) ; F AN Duct x 1 ; CPU Heat Sink x 2 ; Silm type CD-ROM drive (Instal.
9 Feature Summary Motherboard GA-9IVDPC Processor Supported Dual socket 604 for Intel ® Xeon(Nocona/Irwindale) processor suopprts 3.6 GB and upper Intel ® Xeon (Nocona/Irwindale) CPUs su.
10 GS-SR195V Rack Mount Server SCSI Controller: Controller Adaptec AIC- 7901X chipset RAID Supported Supports Host RAID RAID 0, 1 and 10 data protection Features Mirroring supports automat.
11 GS-SR195V Rack Mount Server Server Management Functions: BMC Chip NS IPMI 1.5 controller Failure Detection IPMI 1.5 specification of Server management Event Logging 32KB Nonvolatile Memory to Log System Failure Events Remote Management Follow the IPMI 1.
12 GS-SR195V Rack Mount Server Please observe the safety information in chapter “Important Safety Information” Do not expose the server to extreme environmental conditions. Protect it from dust, humidity, and heat. Step 2-1: Chassis Removal and Installation Step 1 Loosen thscrew from the top cover.
13 Hardware Installation Process Step 2-2: CPU Installation Please make sure the CPU type and speed that are supported by the motherboard. Step 1 Step 2 Step 1 Raise the locking bar on the socket. Step 2 Aligning the pins of the processor with the socket, insert the processor into the socket.
14 GS-SR195V Rack Mount Server Step 2-3: Heat Sink Installation Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember to apply the thermal conductivity compound on the CPU. Step 2 Seat the heat sink with the four screws.
15 Hardware Installation Process Step 2-5: PCI Expansion Card Installation GS-SR195V provides expansion riser slot for one PCI-X 64/66MHz slot; and one with PCI-E x8 and x4 slots. T o install the peripheral, please go through the following steps. Note: Before installing the PCI expansion card, please check the card size limitation.
16 GS-SR195V Rack Mount Server Step 2-6: Hard Disk Drive Installation Step 1 Press the release button and pull the blank out of the drive bay. Step 2 Remo ve t he h ard disk blank. Slide hard disk into blank and secure it with screws. Step 3 Slide the drive into the cage until it clicks, locking the drive into place.
17 Hardware Installation Process Step 2-8: ZCR Installation and Removal (Optional Device) Step 1 Aling a ZCR on the module such that the notch on the ZCR exactly match the notches in the module. Step 2 Push the card in untill it clicks. Then, press down the card vertically.
18 GS-SR195V Rack Mount Server 3-1: Front View of GS-SR195V Chapter 3 Appearance of GS-SR195V M O R - D C e p y T m i l S r o t c e n n o C B S U s D E L s D D H I S C .
System Appearance 19 3-2: Rear View of GS-SR195V s r o t c e n n o C 2 / S P s r o t c e n n o C B S U ) 5 4 J R ( t r o P 1 N A L ) 5 4 J R ( t r o.
20 GS-SR195V Rack Mount Server 3-3: Switch and LED Indicators Introduction Power NMI LAN1/2 Activities ID BTN&LED Name Power SYS (System) HDD LAN1 Activity LAN2 Activity ID (Identification) System.
21 LED Description 3-4: LAN LED Description Color Condition Description Green O N LAN Link / no Access Green BLINK LAN Access - O F F Idle Y ellow O N 1Gbps connection Green O N 100Mbps connection - O.
22 GS-SR195V Rack Mount Server 3-5 : Connector Icon Description n o c I t s e g g u Sn o i t p i r c s e D d r a o b y e K A G V e s u o M N A L t r o P l a i r e S B S U.
23 Motherboard Layout 4-1: GA-9IVDPC Motherboard Layout Chapter 4 Motherboard Layout & Jumper Setting 1 COM2 7 1 7 1 7 1 1 P C I-E_ 1 BAT 1 DDR -A 1 / 11 S M 1 - 2 111 84 - 1 0R E C 4 C 11 0 C 11 .
24 GS-SR195V Rack Mount Server A CPU 0 M DDR A2 B CPU1 N DDR B2 C Intel MCH E7320 O DDR A3 D A TI Rage-XL P DDR B3 E Intel 6300ESB Q DDR A4 F Broadcom ® BCM5705 R DDR B4 G Broadcom ® BCM 5721 S IPMI.
25 Motherboard Layout 4-2: DDR DIMM Slot Population n o i t a r u g i f n o C M M I D1 M M I D2 M M I D3 M M I D4 M M I D k n a R e l g n i S 1y t p m Ey t p m Ey t p m Ek n a R e l g n i S k n a R l .
26 GS-SR195V Rack Mount Server 1 COM2 7 1 7 1 7 1 1 PC I-E_ 1 BAT 1 DDR -A 1 / 11 SM 1- 2 111 84 -1 0R EC 4 C 11 0 C 11 9 DDR -B 1 DDR -A 2 DDR -B 2 C1 33 C 11 2 DDR -B 3 DDR -A 4 2 1 DDR -B 4 4-3: Jumper Setting CLR_CMOS ( (Clear CMOS Function) Y ou may clear the CMOS data to its default values by this jumper .
27 Jumper Setting BIOS_WP (BIOS Werite Protect Function) 1 COM2 7 1 7 1 7 1 1 PC I-E_ 1 BAT 1 DDR -A 1 / 11 SM 1 -2 111 84 - 1 0R EC 4 C 11 0 C 11 9 DDR -B 1 DDR -A 2 DDR -B 2 C1 33 C 11 2 DDR -B 3 DDR -A 4 2 1 DDR -B 4 1 1 2-3 close: BIOS writable.
28 GS-SR195V Rack Mount Server < Ç > Move to previous item < È > Move to next item < Å > Move to the item in the left hand < Æ > Move to the item in the right hand <Esc&.
29 BIOS Setup z z z z z Main This setup page includes all the items in standard compatible BIOS. z z z z z Adva nced This setup page includes all the items of AMI special enhanced features. (ex: Auto detect fan and temperature status, automatically configure hard disk parameters.
30 GS-SR195V Rack Mount Server Syste m Ti me The time is calculated based on the 24-hour military time clock. Set the System Time (HH:MM:SS) Syste m Date Set the System Date. Note that the “Day” automatically changed after you set the date.
31 BIOS Setup IDE Cha nnel 0 Ma ster , Slave / Cha nnel 1 M aster , Slave, Seri al A T A The category identifies the types of hard disk from drive C to F that has been installed in the computer. There are two types: auto type, and manual type.
32 GS-SR195V Rack Mount Server System Information This category includes the information of Processor Type, Speed, Extended memory, BIOS Version, BIOS Date, System Product Name, System serial number, System version, System UUID, Main Board ID, and Main Board Serial number.
33 BIOS Setup Figure 2: Advanced Adva nced About This Section: Advanced With this section, allowing user to configure your system for basic operation. User can change the processor options, chipset configuration, PCI configuration and chipset control.
34 GS-SR195V Rack Mount Server PCI Configuration Figure 2-1: PCI Configuration Embedded Video Controller Onboard VGA Control Enabled Enable onboard VGA device.
35 BIOS Setup Embedded NIC (Gbit #1 / 2) Onboard LAN Control Enabled Enable onboard LAN 1 / 2 device. (Default value) Disabled Disable this function. Option ROM Scan Enabled Enableing this item to initialize device expansion ROM.
36 GS-SR195V Rack Mount Server Advanced Chipset Control Figure 2-2: Advanced Chipset Control USB Controller This item allows users to enable or disable the USB device by setting item to the desired value. Enabled Enable USB controller.
37 BIOS Setup For ce Complia nce Mode This option allows user to function PCI-E Compliance mode by setting item to desired value. Enabled Enables PCI-E Force Compliance mode. (Default V alue) Disabled Disables this function.
38 GS-SR195V Rack Mount Server Memory Frequency Determine the specifiy memory frequency. 266MHz Select 266MHz as memory frequecncy for system. 333MHz Select 333MHz as memory frequecncy for system. Auto Auto determine memory frequency for system.
39 BIOS Setup Advanced Processor Option Figure 2-3: Advanced Processor Option Hyper Threa ding T echnology Enabled Enables Hyper-Threading T echnology Feature when using Windows XP operating systems that are optimized for Hyper-Threading technology.
40 GS-SR195V Rack Mount Server Thermal Ma nagerment 2 Select between TM1 and TM2. Enabled Select Thermal Management 2 function.
41 BIOS Setup Peripheral Configuration PhoenixBIOS Setup Utility Peripheral Configuration Item Specific Help Serial Port A [Enabled] Base I/O address/IRQ [3F8/IRQ4] Serial Port B [Enabled] Base I/O ad.
42 GS-SR195V Rack Mount Server Serial Port B This allows users to configure serial prot B by using this option. Disabled Disable the configuration. Enabled Enable the configuration (Default value) Base I/O Address/IRQ 3F8/IRQ4 Set IO address to 3F8.
43 BIOS Setup Seri al A T A Enabled Enable Serial A T A device. (Default value) Disabled Disable the Serial A T A. Native Mode Operation This option allows user to set the native mode for A T A function.
44 GS-SR195V Rack Mount Server Extended Me mory T esting Determine which type of tests will be performed extended memory. (above 1M) Enabled Enable Extended Memory T esting.
45 BIOS Setup Hardware Monitor Figure 2-5: Hardware Monitor CPU 1&2/ System/ W83792d 1/2/3 T emperatur e Display the current CPU1/2 temperature, System, and W83792d 1/2/3 ambient temperature. V oltage: VCORE 1&2/ 3.
46 GS-SR195V Rack Mount Server Security Figure 3: Security * * * * * About This Section: Security In this section, user can set either supervisor or user passwords, or both for different level of password securities. In addition, user also can set the virus protection for boot sector.
47 BIOS Setup Set User Password Y ou can only enter but do not have the right to change the options of the setup menus. When you select this function, the following message will appear at the center of the screen to assist you in creating a password.
48 GS-SR195V Rack Mount Server Server Figure 4: Server PhoenixBIOS Setup Utility Main Advanced Security Server Boot Exit Console Redirection Item Specific Help Halt On [Mid] Clear Mem.
49 BIOS Setup Com Port Address If this option is set to enabled, it will use a port on the motherboard. On-board COMA Use COMA as he COM port address. On-board COMB Use COMB as he COM port address. Disabled Disable this function.
50 GS-SR195V Rack Mount Server Halt On The category determines whether the computer will stop if an error is detected during power up. NO Errors The system boot wil l not stop for any error that may be detected and you will be prompted.
51 BIOS Setup Boot * * * * * About This Section: Boot The “Boot” menu allows user to select among four possible types of boot devices listed using the up and down arrow keys. By applying <+> and <Space> key, you can promote devices and by using the <-> key, you can demote devices.
52 GS-SR195V Rack Mount Server Exit Figure 6: Exit * * * * * About This Section: Exit Once you have changed all of the set values in the BIOS setup, you should save your chnages and exit BIOS setup program. Select “Exit” from the menu bar, to display the following sub-menu.
53 BIOS Setup Exit Saving Cha nge s This option allows user to exit system setup with saving the changes. Press <Enter> on this item to ask for the following confirmation message: Pressing ‘Y’ to store all the present setting values tha user made in this time into CMOS.
54 GS-SR195V Rack Mount Server Discard Cha nge s This option allows user to load previos values from CMOS for all setup item. When you press <Enter> on this item, you will get a confirmation dialog box with a message as below: Save Cha nge s This option allows user to save setup dat ato CMOS.
Appexdix 55 Acronyms Meaning ACPI A d v anced Configuration and Power Interface A P M Advanced Power Management A G P Accelerated Graphics Port A M R Audio Modem Riser A C R Advanced Communications Ri.
56 GS-SR195V Rack Mount Server Acronyms Meaning I / O Input / Output IOAPIC I n p u t O u t p u t Advanced Programmable Input Controller I S A Industry Standard Architecture L A N Local Area Network L.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Intel GS-SR195V è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Intel GS-SR195V - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Intel GS-SR195V imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Intel GS-SR195V ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Intel GS-SR195V, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Intel GS-SR195V.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Intel GS-SR195V. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Intel GS-SR195V insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.