Manuale d’uso / di manutenzione del prodotto (A)BCG385T500-8N del fabbricante American Water Heater
Vai alla pagina of 40
1 Service Handbook PRINTED IN THE U . S .A 0510 318664-000 SERVICING SHOULD ONL Y BE PERFORMED BY A QUALIFIED SER VICE AGENT . COMMERCIAL GAS W A TER HEA TERS INST ALLA TION CONSIDERA TIONS - PRE SERVICE CHECKS - W A TER HEA TER CONSTRUCTION - OPERA TION & SERVICE - TROUBLESHOOTING P.
2 Servicing should only be performed by a Quali fi ed Service Agent INTRODUCTION ............................................................3 Qualifications ........................................................... 3 Service W arning..............
3 Servicing should only be performed by a Quali fi ed Service Agent INTRODUCTION INTRODUCTION This Service Manual is designed to be an aid in servicing and troubleshooting American models (A)BCG385T500-8N/8P Series 120/121 commercial water heaters.
4 Servicing should only be performed by a Quali fi ed Service Agent REQUIREMENTS REQUIREMENTS INSTRUCTION MANUAL Have a copy of the instruction manual that came with the water heater on hand for the model being serviced. Instruction manuals can be obtained at the American W ater Heaters web site (www .
5 Servicing should only be performed by a Quali fi ed Service Agent INST ALLA TION CONSIDERA TIONS INST ALLA TION CONSIDERA TIONS Installation information given in this service manual IS NOT a complete installation instruction. Installation information covered in this service manual has a limited focus as it applies to servicing.
6 Servicing should only be performed by a Quali fi ed Service Agent INST ALLA TION CONSIDERA TIONS AIR REQUIREMENTS Carefully review the requirements for combustion and ventilation air in the instruction manual that came with the water heater .
7 Servicing should only be performed by a Quali fi ed Service Agent INST ALLA TION CONSIDERA TIONS Insufficient Make-up Air , Negative Air Pressure, and Downdrafts A lack of combustion and ventilation air can create a negative ambient air pressure in the installed space.
8 Servicing should only be performed by a Quali fi ed Service Agent INST ALLA TION CONSIDERA TIONS Make-up Air: Direct Communication with Outdoors A fresh supply of make-up air for combustion can be supplied to the water heater through make-up air ducts, which directly communicate with the outdoors.
9 Servicing should only be performed by a Quali fi ed Service Agent INST ALLA TION CONSIDERA TIONS Contaminated Air Carefully review the warnings concerning contaminated combustion and ventilation air in the instruction manual that came with the water heater .
10 Servicing should only be performed by a Quali fi ed Service Agent INST ALLA TION CONSIDERA TIONS T able 2 MINIMUM CLEARANCES T O COMBUSTIBLE SURF ACES “A” - Right Side “B” - Left Side “C” - Back 5” (12.7 cm) 5” (12.7 cm) 5” (12.7 cm) A, B, and C clearances to non-combustible surfaces is “0” inches.
11 Servicing should only be performed by a Quali fi ed Service Agent INST ALLA TION CONSIDERA TIONS VENTING The (A)BCG385T500-8N/8P water heater is classified by ANSI as a Category I (non- condensing, negative pressure venting) appliance. It is approved for type B vent.
12 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE OPERA TION AND SER VICE SEQUENCE OF OPERA TION 1. Call for heat is activated when temperature sensed from Thermistor Probes falls below the Thermostat setting.
13 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE ELECTRICAL SEQUENCE 1. Switch Power on to unit. 2. Thermostat calls for heat. 3. Ignition Control Board performs diagnostic check on system components. 4. On completion of diagnostics check, the Ignition Control Board energizes the Blower (Draft Inducer).
14 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE WIRING DIAGRAM THERMOST A T IGNITION BOARD UPPER PROBE/ PROBE THERMOPLASTIC OR EQUIV ALENT . MUST BE REPLACED USE ONL Y TYPE 105 C IF ANY OF THE ORIGINAL WIRE AS SUPPLIED BOARD , DIGIT AL THERMOST A T AND CONTROLS.
15 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE OPERA TING SEQUENCE - FLOW CHART Figure 1 1 Po wer On C a ll for Heat S elf diagnos t ic c hec k is perf or.
16 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE GAS CONTROL V AL VE This gas valve is a 24 volt AC combination-step opening valve. It includes two valves assembled in parallel, connected by a wiring harness.
17 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE Manifold Pressure Adjustment The main gas regulators are found beneath the silver or black cap screws. (Natural Gas valves have silver caps; Propane valves have a black caps).
18 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE GAS CONTROL V AL VE/BURNER AREA VIEW Honeywell Gas Va l v e Main Burner Shield Rollout Shield Radiation Shield Main Burner with Hot Surface Igniter (HSI) mounted Figure 14 T able 3 HOT SURF ACE IGNITER (HSI) V olts AC Nominal 80 V AC Ohms Resistance 1 1.
19 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE BLOWER PROVER SWITCH - SETTINGS V ent Connection Exhaust/Outlet Blower Prover Switch Blower (Draft Inducer) Optional Hot W ater Outlet Figure 15 T able 4 BLOWER PROVER SWITCH T ABLE Model Pressure Setting to Close Switch (Inches W .
20 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE THERMOST A T AND IGNITION CONTROL BOARD VIEW Figure 16.
21 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE WHITE RODGERS INTEGRA TED CONTROL - THERMOST A T Figure 17 WHITE RODGERS IGNITION CONTROL BOARD Figure 18 Display LED Label Display LEDs T o Upper T emp. Probe T o Ignition Control Board T o Lower T emp.
22 Servicing should only be performed by a Quali fi ed Service Agent OPERA TION AND SERVICE PRE-SER VICE CHECKLIST Use the following checklist BEFORE you begin servicing the water heater .
23 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TROUBLESHOOTING IGNITION CONTROL BOARD: ERROR CODES The White Rodgers ignition control board will display a flashing error code with an LED light located on the upper left corner of the Ignition Control Board (Figure 18) when there is a problem.
24 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING 3 FLASHES Blower prover (air pressure) switch failed to close its normally open contacts after blower (draft inducer) was energized. Blower will run indefinitely , waiting for the blower prover switch circuit to close.
25 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING 4 Check molex plug connector between igniter/flame sensor assembly and control board; Also check flame sense (12 pin) plug connection at control board. 8 FLASHES Igniter not sensed and/or water heater not grounded.
26 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING INTEGRA TED HEA TER CONTROL: DISPLA Y LIGHTS Power Energy Cut Off Status Call for Heat Reset Status LED ST A TUS INDICA TION ACTION Calling for heat Normal status. No action required.
27 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 1: 120 V AC T O HEA TER CHECK Conditions: • No Green Display “Power” LED on. • Plugs are in receptacles. • Supply power breaker is not open. • On/Off heater switch is on.
28 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 2: POLARITY CHECK Conditions: No hot water • Green “Power” LED is on. • T ank is more than 5° F below temperature dial setting. • Red ignition control board diagnostic LED is flashing 6 times between pauses.
29 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 3: CONTINUITY CHECK OF HIGH LIMIT (ECO) Conditions: Power On – No Hot W ater • Red, heater control “Call for Heat” LED – on • Red ignition control board diagnostic LED – 4 Flashes • Note LED Flash Code before resetting water heater control.
30 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 4: UPPER TEMPERA TURE PROBE CONTINUITY CHECK Conditions: Power On - W ater below temperature set point. • Red, water heater control “Reset Status” LED-OFF • “Call For Heat” LED off.
31 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 5: CALLING FOR HEA T - NO BLOWER OPERA TION Conditions: Power on • Plugs in Receptacles • Red “ Call for Heat” LED - ON • Blower (Draft Inducer) off • Note flash code on ignition control board diagnostic LED.
32 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 6: BLOWER ON, NO IGNITION Conditions: Power on • Plugs in receptacles • Blower (Draft Inducer) operating • No power to Hot Surface Igniter (HSI). Note LED flash code.
33 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 7: BLOWER ON, BLOWER PROVER SWITCH CLOSED, NO IGNITER OPERA TION Conditions: Power on, but no power to ignite.
34 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 8: IGNITER HEA TS, NO MAIN BURNER 24 V . E1 Plug to Pin 9 E1 Plug to Pin 12 Figure 27 TEST 8 IGNITER HEA TS......NO MAIN BURNER IF ......... then............ short heat up time of igniter check control box grounding.
35 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 9: IGNITER HEA TS, NO MAIN BURNER Conditions: T est 8 completed • T urn off power • Disconnect wires from.
36 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 10: MAIN BURNER IGNITION FOR LESS THAN FIVE SECONDS Conditions: Power On; plug connected • Main Burner ignites for approximately five seconds, then goes out. • T ests 8 and 9 completed • Note the flash code on the ignition board LED.
37 Servicing should only be performed by a Quali fi ed Service Agent TROUBLESHOOTING TEST 1 1: W A TER HEA TER SHUTTING OFF BELOW SETTING Conditions: Main burner ignited • Stored water is below temperature setting more than 5° F (T ank Average).
38 Servicing should only be performed by a Quali fi ed Service Agent NOTES.
39 Servicing should only be performed by a Quali fi ed Service Agent NOTES.
Copyright © 2010 American Water Heater Company . All rights reserved. P .O. Box 1597, Johnson City , TN 37605 Phone: 800-456-9805 • Fax: 800-999-5210 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il American Water Heater (A)BCG385T500-8N è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del American Water Heater (A)BCG385T500-8N - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso American Water Heater (A)BCG385T500-8N imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul American Water Heater (A)BCG385T500-8N ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il American Water Heater (A)BCG385T500-8N, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del American Water Heater (A)BCG385T500-8N.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il American Water Heater (A)BCG385T500-8N. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo American Water Heater (A)BCG385T500-8N insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.