Manuale d’uso / di manutenzione del prodotto Blood pressure monitor BP5 del fabbricante iHealth
Vai alla pagina of 17
iHealth™ Wireless Blood Pressure Monitor (BP5) OWNER’S MANUAL Table of Contents INTRODUCTION ................................................................................................................................. 2 PACKAGE CONTENTS .....
2 INTRODUCTION Thank you for selecting the iHealth Wireless Blood Pressure Monitor. The iHealth Wireless Blood Pressure Monitor is a fully automatic arm cuff blood pressure monitor that uses the oscillometric principle to measure your blood pressure and pulse rate.
3 CONTRAINDICATION It is not recommended for people with serious arrhythmia to use this Wireless Blood Pressure Monitor. PARTS AND DISPLAY INDICATORS SET UP REQUIREMENTS The iHealth Wireless Blood Pre.
4 Connect to iOS Device via Bluetooth • Apply the cuff or press the START/STOP button, the Bluetooth indicator will begin flashing. • Turn Bluetooth "On" under the "Settings" menu on the iOS device. • Wait until the model name printed on the monitor, (i.
5 Lying Down During Measurement a. Lie on your back. b. Place your arm straight along your side with your hand palm-side up. c. The cuff should be placed at the same level as your heart. Note: Blood pressure can be affected by the position of the cuff and your physiologic condition.
6 During measurement, press the “START/STOP” button to stop measurement. Press the “START/STOP” button for 2 seconds to turn off the monitor manually. Auto Connect Option Auto connect option allows the monitor to find the last used iOS device and re-establish the connection automatically.
7 measurement 8. Memory volume: 120 times with time and date stamp (off-line measurement only) 9. Power: DC: 5.0V 1.0A, Battery: 1*3.7V Li-ion 400mAh 10. Measurement range: Cuff pressure: 0-300 mmHg Systolic: 60-260 mmHg Diastolic: 40-199 mmHg Pulse rate: 40-180 beats/minute 11.
8 device be set in Airplane mode during measurement to avoid strong magnetism interference. 6. If Irregular Heartbeat (IHB) is detected during the measurement procedure, the IHB symbol will be displayed. Under this condition, the Wireless Blood Pressure Monitor can keep functioning, but the results may be inaccurate.
9 BATTERY HANDLING AND USAGE • When the monitor is connected to the iOS device, the battery volume will be displayed on the iOS device. If the power is less than 25%, please charge the battery. The monitor will not work until the battery has enough power.
10 The cuff does not inflate properly or pressure falls quickly during test Review the cuff application instructions and retest Irregular heartbeat (arrhythmia) It is inappropriate for people with serious arrhythmia to use this monitor. Check with physician.
11 CARE AND MAINTENANCE 1. If this monitor is stored near freezing temperatures, allow it to acclimate to room temperature before use. 2. If the monitor is not used for a long time, please sure to fully charge it every month. 3. It is recommended that product performance be checked every 2 years or after each repair.
12 EXPLANATION OF SYMBOLS Symbol for “TYPE BF APPLIED PARTS” (Cuff only) Symbol for ”THE OPERATION GUIDE MUST BE READ” The sign background color: blue The sign graphical symbol: white Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste.
13 EC REP Lotus Global Co., L td. 15 Alexandra Road, L ondon U K, N W8 0 DP Tel: +0044-20-75868010 F ax: + 0044-20-79006187 ANDON HEALTH CO., LTD. No. 3 Jinping Street, Y a A n R oad, N ankai D istrict, Tianjin 300190, China Tel: 86-22-60526161 IMPORTANT INFORMATION REQUIRED BY THE FCC This device complies with Part 15 of the FCC Rules.
14 IEC 60601-1-2:2007 (Medical electrical equipment – Part 1: General requirements for safety; Collateral Standard-Electromagnetic compatibility - Requirements and tests); EN 1060-1: 1995 + A1: 2002.
15 ic discharge (ESD) IEC 61000-4-2 ± 8 kV air ± 8 kV air concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.
16 Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz 3 V/m 80 MHz to 2.5 GHz 3V 3 V/m recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance : 80 MHz to 800 MHz 800 MHz to 2.
17 portable and mobile RF communications equipment and the Wireless Blood Pressure Monitor The Wireless Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il iHealth Blood pressure monitor BP5 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del iHealth Blood pressure monitor BP5 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso iHealth Blood pressure monitor BP5 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul iHealth Blood pressure monitor BP5 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il iHealth Blood pressure monitor BP5, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del iHealth Blood pressure monitor BP5.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il iHealth Blood pressure monitor BP5. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo iHealth Blood pressure monitor BP5 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.