Manuale d’uso / di manutenzione del prodotto 54015 del fabbricante Hunter Fan
Vai alla pagina of 17
www .HunterF an.com 1.888.830.1326 PA G E 7 PA G E 13 PA G E 10 PA G E 5 PA G E 6 30 inches 7 feet PA G E 2 What to Expect with Y our Installation Ceiling Br acket Ladder PA G E 3 T ools Needed Wiring.
www .HunterF an.com 1.888.830.1326 M0074-01 • 05/14/14 • © Hunter F an Company 1.888.830.1326 1.888.830.1326 What t o Expec t with Y our Installation Know your wiring If you are unfamiliar with wiring , use a qualied electrician. Y ou may need a friend to help you .
www .HunterF an.com 1.888.830.1326 T ools Needed Ladder Po wer Drill (optional) 9/64” Drill Bit (optional) Screwdrivers Pliers Wire Strippers If mounting to a support structure, you will also need these tools .
www .HunterF an.com 1.888.830.1326 4 M0074-01 • 05/14/14 • © Hunter F an Company 1.866.268.1936 If you ha ve an angled ceiling: 1. Y ou will need a longer downrod (sold separately) . 2. If your ceiling angle is greater than 34°, y ou will also need an Angled Mounting Kit (sold separately) .
www .HunterF an.com 1.888.830.1326 1.888.830.1326 www .HunterF an.com C eiling Bracket 5 Refer to warning w .1 on pg. 2 T o av oid possible elec trical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
www .HunterF an.com 1.888.830.1326 1.888.830.1326 www .HunterF an.com Prepar ation D I S C A R D K E E P ! Remove the shipping blocks fr om the motor . Sav e the screws . They will be needed for blade iron installation. Note: Some fans will hav e a shipping ring instead of shipping blocks.
1.888.830.1326 Downrod Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold Separately Included Longer Downrod for angled ceilings or ceilings 10’ or higher Shorter Downrod for fans installed close to ceiling St.
KEEP! 8” 3/8” C U T & S T R I P (not to scale) Remove the pr e-installed setscrew so that the downrod can be inserted. Hand tighten the downrod (at least 4-5 full turns) until it stops. The wires can be cut, but leave at least 8” extending from the top of the downr od.
1.888.830.1326 9 M0074-01 • 05/14/14 • © Hunter F an Company www .HunterF an.com Downrod (c ontinued) DO NO T PICK THE F AN UP BY THE CANOPY OR WIRES. Place the downrod ball into the slot in the ceiling bracket. Put the wires and do wnrod through the canopy .
www .HunterF an.com 1.888.830.1326 Wiring T urn the splices upward and push them carefully back through the hanger bracket into the outlet box. Spread the wires apart, with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet bo x.
www .HunterF an.com 1.888.830.1326 11 M0074-01 • 05/14/14 • © Hunter F an Company Canop y Lift the canopy into place so that the screw holes are aligned . Position the canop y so that, when lifted into place , the canopy ts into the hanging bracket as shown.
www .HunterF an.com 1.888.830.1326 M0074-01 • 05/14/14 • © Hunter F an Company Blades Y our blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. F or cleaning the fan, use soft brushes or cloths to prevent scratching .
www .HunterF an.com 1.888.830.1326 F eed the wire plug through the center hole of the upper switch housing , then wrap keyhole slots around the screws and twist counterclockwise. Screw two housing assembly screws from the hardware bag halfwa y into the motor housing .
www .HunterF an.com 1.888.830.1326 S witch Housing (continued) Make sure the lower switch housing is securely attached to the upper switch housing. F ailure to properly secur e all three assembly screws could result in the switch housing falling . Connect the plugs from the upper and lower switch housings .
www .HunterF an.com 1.888.830.1326 Within 3 minutes of rest oring power to the fan, press both the F an Off button and the High button f or at least 4 seconds. Y our fan will turn on low to indicate succ essful syncing. If it does not, turn off power to y our fan, wait 1 minute then try again.
www .HunterF an.com 1.888.830.1326 16 M0074-01 • 05/14/14 • © Hunter F an Company 16 F or cleaning the fan, use sof t brushes or cloths to prevent scr atching.
www .HunterF an.com 1.888.830.1326 M0074-01 • 05/14/14 • © Hunter F an Company 17 T roubleshooting F an doesn’ t work • Make sure power switch is on. • Pull the pull chain to make sure it is on. • Push the motor r eversing switch rmly left or right to ensure that it is engaged.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hunter Fan 54015 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hunter Fan 54015 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hunter Fan 54015 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hunter Fan 54015 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hunter Fan 54015, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hunter Fan 54015.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hunter Fan 54015. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hunter Fan 54015 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.