Manuale d’uso / di manutenzione del prodotto 40170 del fabbricante Hunter
Vai alla pagina of 33
Ele c tr on ic/M e chani c al er most a t Mo d el 40170 ins t allat ion and op erat ion manual 42998-01 01-19-2007.
2.
3 T able of Contents Important Information.................................................. 5 T ools ............................................................................ 6 Uninstalling the Existing Unit ...................................... 9 Installing the T hermostat .
4 Congratulations! T hank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year -round energy savings . Please read this manual before beginning installation and save this booklet for complete operation instructions .
5 T his thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – F ired Boilers Gas – Millivolt Systems Oil – F ired .
6 T his thermostat includes two #8 slotted screws and two w all anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ........................................................................
7 NO TICE! Do not disconnect the wir es fr om the existing thermostat before r eading these instructions . The wires must be labeled prior to r emoval to ensur e proper r econnection.
8 UNINST ALLING THE EXISTING UNIT Y RC G W Y RC G W.
9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV A C system OFF at the main power panel or at the furnace . 2. Remove the existing thermostat cover to access the wires from the w all. (Some thermostats may have multiple covers , screws or other locking devices that must be removed or disengaged.
10 UNINST ALLING THE EXISTING UNIT , CONT . if your existing thermostat is marked ... label the wire with this sticker: G / F G G W / H W W Y / C* / M Y Y RC / VC RC RC RH / R / VR / 4 RH RH 24 V olt .
11 4. Using the provided stick ers , label each wire according to the chart. (If the terminals are not labeled, contact a qualified HV A C technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification.
12 T op Cover T hermostat.
13 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the top cover from the new thermostat by pulling the two halves apart..
14 W RC Y G.
15 2. P osition the new thermostat on the w all and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter w all plate , or if there are no existing holes , level the thermostat and mark the w all for two holes .
16 INST ALLING THE THERMOST A T , CONT . G RC RH Y W B O R H R C W G B O Y.
17 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove , the terminal screws . Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper .
18 INST ALLING THE THERMOST A T , CONT . HG HE HP STD HE/HG Switch HP/STD Switch.
19 A TT A CHING THE THERMOST A T 1. Locate the HE/HG switch on the w all plate . Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces . (T he switch has no effect when the system is set to cooling mode .) 2.
20 INST ALLING THE THERMOST A T , CONT ..
21 3. Insert two fresh AA alkaline batteries . 4. Align the top cover with the the w all plate , and snap the two halves together . 5. Restore power at the electrical panel or furnace .
22 AUT O ON COOL OFF HEA T SYSTEM 9 0 0 7 0 6 0 5 8 0 F an Switch System Switch Set T emperature Slider.
23 OPERA TION 1. Set the Set Temperature slider to the desired temperature . 2. T he System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. T he Fan Switch should normally be located in the Auto position. T o run the fan continuously , slide the Fan Switch to the On position.
24 INDICA TORS AND ADUSTMENT 0 5 0 6 0 7 8 0 9 0 T hermometer Battery Indicator.
25 INDICA TORS AND ADUSTMENT 1. T he Thermometer indicates the room temperature . 2. T he Battery Indicator displays two battery conditions . T he first w arning is the Weak Battery Warning , indicated by the Battery Indicator flashing once approximately every three seconds .
26 SP AN Span Adjust SP AN.
27 INDICA TORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o mak e your system run LONGER, turn the Span Adjust clockwise . 3. T o mak e your system run SHOR TER, turn the Span Adjust counter clockwise . 4. Reattach the top cover to the thermostat.
28 1. My heating or cooling will not turn on or off . 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b . W ait. T here may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit break ers and switches to ensure there is enough power to the system.
29 Is there help on the web? Y es . V isit http://www .hunterfan.com for more information. ............................................................................................. Can’t I just call someone? Sure . Our T echnical Support Group is av ailable from 8 am to 5 pm CST .
30 G Rc Rh W Y F an Relay Heat/C ool 24V Supply Cool Contactor Heat Rela y or V alve X Jumper 4-wire Heat/C ool System G Rc Rh F an Relay He at 24V Supply W Heat Relay or V alve Y Cool Contactor 5-wir.
31 WIRING DIAGRAMS Reversing V alve Compressor Contactor X F an Relay Heat/C ool 24V Supply Single-stage Heat P ump System Cool Mode Heat Mode OR W G Rc Rh O B Y X Jumper Rc R h W Heat 24V or Millivol.
32 G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh Y Coo.
33 © 2007 Hunter F an Company.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Hunter 40170 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Hunter 40170 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Hunter 40170 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Hunter 40170 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Hunter 40170, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Hunter 40170.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Hunter 40170. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Hunter 40170 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.