Manuale d’uso / di manutenzione del prodotto Triplex Ceramic Plunger Pump LP350 del fabbricante HP
Vai alla pagina of 12
Models LP350, LP400, LP450 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: page 2 Pump Specifications: pages 3-5 Exploded View: page.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 Specifications Model LP350 Volume ................................................................................................... Up to 22.6 GPM Discharge Pressure .................................................................................
4 Specifications Model LP400 Volume ................................................................................................... Up to 15.1 GPM Discharge Pressure .................................................................................
5 Specifications Model LP450 Volume ................................................................................................... Up to 19.7 GPM Discharge Pressure .................................................................................
6 LP350, LP400, LP450 - EXPLODED VIEW.
7 ITEM # PART # DESCRIPTION QTY 1 07759 Crankcase 1 2 13000 Oil filler plug assy. 1 4 06085 Crankcase Cover 1 5 07104 O-ring, Crankcase cover 1 6 07186 Oil Sightglass with Gasket 1 8 06086 Oil Dipstic.
8 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace .
9 REPAIR INSTRUCTION - LP350, LP400, LP450 T O CHECK V AL VES 4) Inspect valve seats (46A) and valve plates (46B) for damage and replace if needed. Check valve casing (43) surfaces for damage. Replace o-rings (44A) and reinstall valve assemblies (46) into valve casing.
10 9) Remove seal case (37) from seal sleeve (35). 10) Check plunger surface (25 and 29B) for wear and pit- ting. If none is found, pro- ceed to step twelve. 11) If plunger (29B) is worn, re- move tension screw (29C) with a 17mm wrench. Clean tension screw with wire brush to remove any old locktite.
11 DISASSEMBLY OF CRANKCASE 1) Remove valve casing (43) and plunger pipe (29B), drain oil. 2) Screw off gear cover (4) and bearing cover (14). 3) Remove connecting rod screws (24) and push the front of connecting rod forward as far as possible. Remove back halves of connecting rods, note which position from which they came from.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il HP Triplex Ceramic Plunger Pump LP350 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del HP Triplex Ceramic Plunger Pump LP350 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso HP Triplex Ceramic Plunger Pump LP350 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul HP Triplex Ceramic Plunger Pump LP350 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il HP Triplex Ceramic Plunger Pump LP350, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del HP Triplex Ceramic Plunger Pump LP350.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il HP Triplex Ceramic Plunger Pump LP350. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo HP Triplex Ceramic Plunger Pump LP350 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.