Manuale d’uso / di manutenzione del prodotto 2180206H del fabbricante HP (Hewlett-Packard)
Vai alla pagina of 36
Installation and operating instructions Combi HP Thermostatic mixer shower T00219 2180206H March 2007 I nstallers please note these InstructIons are to be left wIth the user.
Combi HP thermostatic mixer shower Introduction 1 Safety warnings 1 Main components 2 Siting requirements 3 T ypical suitable installations 4 Preparing the mixer valve 6 Siting of the shower 6 Fitting.
1 Combi HP thermostatic mixer shower INTRODUCTION SAFETY WARNINGS C-006-A INTRODUCTION T his book contains all the necessary fitting and operating instructions for your T riton high pressure thermostatic mixer shower . Please read them carefully . Please read through the whole of this book before beginning your installation.
2 Combi HP thermostatic mixer shower 1. Inlet nuts and olives 2. Inlet elbows 3. V alve housing 4. Outlet adaptor 5. Outlet nut and olive 6. Outlet blanking plug 7. Cartridge assembly 8. Flow knob 9. T emperature knob 10. Knob trim 11. Max. temperature override button 12.
3 Combi HP thermostatic mixer shower SITING REQUIREMENTS D-003-A SITE REQUIREMENTS The installation must be in accordance with W ater Regulations/Bylaws. Minimum running water pressure: 1 bar . Maximum running water pressure: 5 bar . Maximum static water pressure: 10 bar .
4 Combi HP thermostatic mixer shower a) Instantaneous gas-heated showers, e.g. combination boilers (fig.2) The shower control MUST be installed with a multipoint gas water heater or combination boiler of a fully modulating design (i.e. where the water draw-off rate indirectly controls the gas flow to the burner).
5 Combi HP thermostatic mixer shower packages with a cold take off after the pressure reducing valve to the cylinder . The layout and sizing of pipework must be such that nominally equal inlet supply pressures are achieved and the effects of other draw-offs are minimised.
6 Combi HP thermostatic mixer shower Height of showerhead and shower to suit user ’ s requirement. Shower can be mounted either side of the riser rail T00225 Before starting the installation, make sure all the openings on the valve are carefully covered to prevent ingress of any debris etc.
7 Combi HP thermostatic mixer shower Exposed Note: The outlet of the shower must not be connected to anything other than the hose and showerhead supplied. DO NOT use jointing compounds on any pipe fittings for the installation. DO NOT solder fittings near of the shower unit, as heat transfer can damage components.
8 Combi HP thermostatic mixer shower T00022 Hose end (flat) Pipe end (chamfered) screws are slack allowing the inlet elbows to rotate to the correct position and move freely in and out of the valve housing (fig.8) . Place the valve housing centrally between the two pipes, and mark the two diagonal fixing holes (figs.
9 Combi HP thermostatic mixer shower If installing a riser rail, fit the outlet adaptor into the bottom outlet hole in the valve housing. The adaptor is sealed with an ‘O’ ring. Make sure the adapter is fitted with the pipe end in the valve housing (fig.
10 Combi HP thermostatic mixer shower Rear entry supplies Note: The final separation between pipe centres needs to be about 153 mm but absolute accuracy is not essential as the inlet elbows are adjustable between 146 mm and 160 mm (fig.
11 Combi HP thermostatic mixer shower Remove the valve. Drill and plug the holes using the wall plugs supplied. Using two hexagonal nuts (supplied), refit the valve to the pipework. Make sure the hot inlet port (marked with the letter ‘H’ on the valve housing) is connected to the hot pipework which must be on the left.
12 Combi HP thermostatic mixer shower where it is required i.e. bottom outlet for fixed head, top outlet for a hose (fig.20) . Fit the inlet blanking trims on the underside of the cover (fig.28) . Fit the outlet trim over the outlet adaptor and slide the cover on (fig.
13 Combi HP thermostatic mixer shower FITTING THE SHOWER TO THE WALL - BUIL T -IN FITTING THE SHOWER TO THE WALL Opening needs to be at the bottom if using a bulkhead 200 m m 10 - 12.5 m m 48 m m 50 mm 35 m m 77.5 m m 65 mm 220 mm T00249 Fig.29 T00250 Fig.
14 Combi HP thermostatic mixer shower T00251 T00253 Seal tight up to shroud T00252 Fig.31 Fig.32 Fig.33 shower from the top (falling), the bottom (rising) or the rear .
15 Combi HP thermostatic mixer shower Where this is not possible refer to the ‘flushing procedure’ on page 20. Refit the valve to the mounting bracket/wall surface and pipework (fig.
16 Combi HP thermostatic mixer shower Fit the flush mount cover (fig.37) . Locate the lugs on the trim ring in the holes on the cover (fig.38) and twist clockwise. Complete the fitting of your shower accessories. Hollow wall The wall mounting bracket supplied with the shower is suitable for use on a plasterboard wall of 9.
17 Combi HP thermostatic mixer shower washer . Make sure the inlet elbows are positioned the correct way . Offer the valve up to the mounting bracket and secure using the screws provided (fig.42) . Complete the pipework to the shower marking off the length to enter the elbows.
18 Combi HP thermostatic mixer shower T00253 Seal tight up to shroud drill and plug the holes. Note: If fitting to plasterboard, use suitable cavity fixings. Break off the alignment tabs on the flush mount plate (fig.36). Place a ring of silicon sealant round the plate so that the plate seals against the wall.
19 Combi HP thermostatic mixer shower correct way . Offer the valve up to the mounting bracket and secure using the screws provided. Secure the mounting bracket together with the valve to the panel using two bolts in the innermost fixing holes (fig.46) .
20 Combi HP thermostatic mixer shower Removal and/or fitting of check valves for maintenance IMPORT ANT : It is preferable to flush the pipework before installing the valve. Where this is not possible, the procedure using a flushing cartridge should be followed.
21 Combi HP thermostatic mixer shower FITTING THE T AMPERPROOF FIXED HEAD - EXPOSED FITTING THE T AMPERPROOF FIXED HEAD (Exposed option only) Complete the outlet pipework from the valve and cut the pipe to required length. Place the fixed head unit on top of the pipe work and mark the position of the three fixing holes (fig.
22 Combi HP thermostatic mixer shower FITTING THE T AMPERPROOF FIXED HEAD - BUIL T -IN FITTING THE T AMPERPROOF FIXED HEAD (Built in option only) Complete outlet pipework from the valve ending in a ½” BSP female threaded fitting (not supplied) (fig.
23 Combi HP thermostatic mixer shower FITTING THE FIXED HEAD - BUILT -IN FITTING THE FIXED HEAD (Built in option only) The outlet pipe should protrude from the surface of the wall between 50 mm and 65 mm (fig.65) . Mark four fixing hole positions by using the fixed arm as a template.
24 Combi HP thermostatic mixer shower T00081 Appropriate fitting (Riser rail option only) Complete the outlet pipework ending in a ½" x 15 mm female thread fitting (fig.68) . Note: This fitting is not supplied as variations in installations needs the selection of the most suitable fitting.
25 Combi HP thermostatic mixer shower Make sure all plumbing supplies are connected and turned on. Starting the shower T o start the shower , turn the outer knob (flow control) anti-clockwise (fig.74) . Adjusting the shower temperature T o adjust the temperature, turn the inner knob — temperature control (fig.
26 Combi HP thermostatic mixer shower T00297 0D[LPXPWHPSHUDWXUHVWRSPHFKDQLVP 'HFUHDVHVWRSSRVLWLRQ,QFUHDVHVWRSSRVLWLRQ 7 5 ,.
27 Combi HP thermostatic mixer shower T00298 1. HP valve cartridge (built-in valve) 83304970 2. HP cartridge and brass housing (exposed valve) 83304960 3. Outlet adaptor chrome 7031462 gold 7031463 4. Inlet elbow assembly 83303810 5. Outlet blanking plug 7031460 6.
28 Combi HP thermostatic mixer shower T00299 SP ARE P ARTS 14. Bulkhead assembly white 83303780 chrome effect 83303770 gold effect 83303790 − T rim disc (use with flush gold effect) 7051451 15. Inlet & outlet nuts 83303660 16. Spanner 7011766 − Flow regulator 22003530 17.
29 Combi HP thermostatic mixer shower X-006-A T urn the control knob anti-clockwise. T urn the control anti-clockwise. Reduce the simultaneous demand from supply — make sure a dedicated supply to mixer . Contact Customer Service for advice on flow regulators.
30 Combi HP thermostatic mixer shower FAUL T FINDING Problem/Symptom Cause Action/Cure X-006-A T urn t h e contro l k no b anti-c l oc k wise. T urn the control anti-clockwise. Reduce the simultaneous demand from supply — make sure a dedicated supply to mixer .
31 Combi HP thermostatic mixer shower.
32 Combi HP thermostatic mixer shower.
33 Combi HP thermostatic mixer shower.
T riton Showers T riton Road Nuneaton W ar wickshire CV11 4NR T riton is a division of Norcros Gr oup (Holdings) Limited TRITON reserve the right to change product specification without prior notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il HP (Hewlett-Packard) 2180206H è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del HP (Hewlett-Packard) 2180206H - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso HP (Hewlett-Packard) 2180206H imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul HP (Hewlett-Packard) 2180206H ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il HP (Hewlett-Packard) 2180206H, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del HP (Hewlett-Packard) 2180206H.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il HP (Hewlett-Packard) 2180206H. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo HP (Hewlett-Packard) 2180206H insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.