Manuale d’uso / di manutenzione del prodotto THX9421 del fabbricante Honeywell
Vai alla pagina of 28
THX932 1 /942 1 Pr estig e ® IA Q and R F EIM With wir eless accessories ® U.S . Registered T rademark. Copyright © 2011 Honeywell International Inc.
Syst em Installa tion Guide 2 6 9 - 24 9 0 — 0 3 Y ou r Honey well advant age RedLINK™ Compatible Increaseyour contentand profitper jobby including RedLINK™accessories that meet yourcustomers comfort andconvenience needs.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 3 6 9 - 24 9 0 — 0 3 MCR29241 MCR32386 Install thermostat 1 • THX9421: Mountthe thermostat andwire toC and Rterminals of the Equipment InterfaceModule (EIM), orto a separate24 volt transformer (not provided).
Syst em Installa tion Guide 4 6 9 - 24 9 0 — 0 3 M32940 [If no wireless accessories are used, skip to Section 4.] Portable Comfort Control Install 2 fresh AAA alkaline batteries Install 3 fresh AA a.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 5 6 9 - 24 9 0 — 0 3 MCR32941 CONNECT CONNECTED S2 S2 S1 S1 Link th ermost at to the wir eless net work (if use d with an EIM or T r ueZONEW ireles s Adapter) 4 Next, linkall components andRedLINK ™ accessories tothe wirelessnetwork.
Syst em Installa tion Guide 6 6 9 - 24 9 0 — 0 3 MCR32943 MCR32942 CONNECT WIRELESS SETUP MCR32935 MCR32934 While theAdd Device screenis displayed on thethermostat, press and r elease the CONNECT buttonon each wirelessdevice, as described below .
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 7 6 9 - 24 9 0 — 0 3 Ins tall opt ional sen sors 1 Mount thesensor on avertical exterior wall,at least 6inches below any overhang.Choose a location protectedfromdirect sunlight.
Syst em Installa tion Guide 8 6 9 - 24 9 0 — 0 3 Setu p Inst aller opti ons ( ISU ) 7 Press CREA TE SETUP to set all system settings oneby one.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 9 6 9 - 24 9 0 — 0 3 5080 Return Air Sensor T ype B 5090 T er minals Wired to Discharge Air Sensor B 5100 Discharge Air Sensor T ype B 5110 A-C.
Syst em Installa tion Guide 10 6 9 - 24 9 0 — 0 3 T ypicalwiring of aconventional system with upto 3-stage heatand 2-stage cool with onetransformer .
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 11 6 9 - 24 9 0 — 0 3 EI M wiring gu ide — heat pum p systems T ypicalwiring of aheat pump system withup to four -stage heatand two-stage cool withone transformer .
Syst em Installa tion Guide 12 6 9 - 24 9 0 — 0 3 EI M wiring gu ide — geot hermal r adiant he at T ypicalwiring for geothermalradiant heat, geothermal for ced-air , and backup heat withone transformer . 1 2 3 U1, U2 or U3 terminals must be used for geothermal radiant heat (ISU 2010).
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 13 6 9 - 24 9 0 — 0 3 Thermo stat wirin g guide s — Prest ige THX932 1 T ypicalwiring of a2-heat / 2-cool con- ventional.
Syst em Installa tion Guide 14 6 9 - 24 9 0 — 0 3 Prest ige TH X932 1 or EI M : Usin g univers al relays to co ntrol he ating o r cooling Powering universalrelaywith separate heating.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 15 6 9 - 24 9 0 — 0 3 Wiring g uide — IAQ equip ment ( EIM or t hermos tat ) "U" terminalscan be usedfor humidification, dehumidificationor ventilation. With po wer supply Without pow er supply T yp ica l hoo ku p of non - pow er ed hu mid ifi er.
Syst em Installa tion Guide 16 6 9 - 24 9 0 — 0 3 Economizer Module wiri ng guides T ypicalwiring of aW7220 Economizer Module fora heat pumpsystem, using a PrestigeTHX9321 thermostator Equipment Interface Module.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 17 6 9 - 24 9 0 — 0 3 Economizer Module wiri ng guides T ypicalwiring of aW7213/W7214 Economizer Module fora heat pumpsystem, using aPrestigeTHX9321 thermostat or EquipmentInterface Module.
Syst em Installa tion Guide 18 6 9 - 24 9 0 — 0 3 The Economizercan greatlyreduceenergy costs if configur ed properly .In some climates thecooling system mayrun hundredsof hours, whenit may not be requir ed tomaintain indoor comfort.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 19 6 9 - 24 9 0 — 0 3 Heat pu mp with o utdoor tempe ratur e lockouts Heat pu mp and ba ckup heat op erati on Outdoor temperatur e lockoutsare optional.See Installer Setup options (ISU3120).
Syst em Installa tion Guide 20 6 9 - 24 9 0 — 0 3 Backu p heat dif ferent ial an d upst age tim er Bas ic and Advan ced T em peratu re Contr ol Opt ions ( ISU 3 0 1 0 ) A backupheat differ .
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 21 6 9 - 24 9 0 — 0 3 Humidification The thermostatcan be setto controlhumidification in allmodes (Heat, Off,Cool [ISU 8060]).A discharge airsensor is requir ed tohumidify in thecool mode.
Syst em Installa tion Guide 22 6 9 - 24 9 0 — 0 3 Commercial dehumidification Dehumidification EquipmentOptions: (ISU 9000) • A/C withLow Speed Fan • A/C with.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 23 6 9 - 24 9 0 — 0 3 Southern Dehumidification Aw ay Mode This featur e lowersthe temperatureup to 3° Fbelow the setpointas needed to preventexcessive humiditywhile the home isunoccupied.
Syst em Installa tion Guide 24 6 9 - 24 9 0 — 0 3 Indoor sensor oper ation Wireless indoor sensor T emperature control The thermostatcan be setto respondto its internal temperaturesensor , or to anoption- al r emote indoorsensor .
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 25 6 9 - 24 9 0 — 0 3 Delta T Fault Sensitivity is adjustab le in the Installer Setup (ISU 13180) Delta T diagnostics is only for non-zoned f orced air systems.
Syst em Installa tion Guide 26 6 9 - 24 9 0 — 0 3 Replacing s ystem components T o replace an Equipment In terface Module ( E IM ) or thermostat Follow stepsbelow to disconnect the thermostat andRedLINK accessories. See pages 5-6to re-link devices.
T H X9 3 21/9 4 21 P r e s t i g e ® IAQ a nd RF EI M 27 6 9 - 24 9 0 — 0 3 Specifications & replacement part s Operating Ambient T emperature Thermostat: 32 to120° F (0to 48.9°C) Portable Comfort Control: 32to 120°F (0to 48.
Regulator y inform ation FCC Compliance Statement ( Part 1 5. 1 9 ) (USA only) This device complies with P art 15 of the FCC Rules. Oper ation is subject to the following two conditions: 1 This device.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Honeywell THX9421 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Honeywell THX9421 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Honeywell THX9421 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Honeywell THX9421 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Honeywell THX9421, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Honeywell THX9421.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Honeywell THX9421. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Honeywell THX9421 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.