Manuale d’uso / di manutenzione del prodotto TE923W del fabbricante Honeywell
Vai alla pagina of 49
HONEYWELL PROFESSIONAL WEA THER ST A TION WITH REMOTE CONTROL TE923W USER MANUAL.
2 T able of Contents Introduction 3 Standard Package Contents 4 Installation 5 Before you begin 6 Ultraviolet (UV) Sensor 6 Remote Thermo-Hygrometer Sensor 9 Rain Gauge 1 1 Anemometer (wind sensor) 13.
3 Introduction Thank you for selecting the Honeywell Professional Weather Station with Remote control. This compact and easy-to-use product features a wide variety of time and weather data, such as pr.
4 Standard Package Contents Picture Components Main Unit Remote Control AC/DC 7.5V power adaptor UV Sensor consists of: Sensor Unit U-Shaped Sensor holder Circular Ground Stand Stake Base W all-Mounti.
5 4 screws for securing rain gauge to the flat surface; 4 screws for securing anemometer to vertical surface Mounting hardware 2m (6ft) USB cable PC connection cable Installation The Honeywell Profess.
6 Before you begin • We recommend using alkaline batteries for the remote weather sensors and the main unit when temperatures are above 32°F (0°C). W e recommend using lithium batteries for the remote weather sensors when te mperatures are below 32°F (0°C).
7 A. LED INDICA TOR • Flashes once when the remote sensor transmits a reading to the main unit • Flashes twice when battery power is low B. BA TTERY COMP ARTMENT SCREW Holds battery compartment door in place C. U-SHAPED SENSOR HOLDER Holds UV sensor in upright position D.
8 screwdriver • Insert two 2 “AA” size 1.5V batteries (not included) matching the polarities shown in the battery compartment. • Replace the battery compartment door and secure the screw • Screw the UV sensor unit lid back Mounting There are three different options available fo r mounting the UV sensor: ground stand, stake and wall mount.
9 Placement tips: The UV sensor should be mounted in the area free of sunlight shadows or reflections from the nearby objects. Remote Thermo-Hygrometer Sensor FEATURES • Remote data transmission to .
10 • Replace the battery compartment door and secure the screws. • Secure the thermo-hygrometer remote sensor in the desired location. Mounting • The remote thermo-hygrometer sensor can be place.
11 Rain Gauge FEATURES • Precipitation measurement • Remote transmission of the rainfall data to the main unit via 433 MHz signal • 100 feet (30 meters) operating range without interference • Built-in installation level • Non-corrosive protective screen A.
12 Secure battery compartment cover G . Built-in level with bubble Ensures level rain gauge mounting for proper operation H . Bucket see-saw mechanism Collects the rainfall in one of its containers and self-empties once f ull I.
13 Anemometer (wind sensor) FEA TURES • Wind speed, wind gust and wind direction measurement • Measures the temperature at the place of anemometer • Remote wind speed, wind gust and wind direction data transmission to the main unit via 433 MHz signal • Operating range 100 feet (30 meters) • W all or pole mount A.
14 E. WIND CUPS SHAFT Holds wind cups on the anemometer arm F . BA TTER Y COMP ARTMENT Holds 2 AA-si ze batteries G. W ALL MOUNT SCREW OPENINGS Allows securing the anemometer in place H. BA TTER Y C OVER Secures battery compartment on the anemometer base Assembly • Slide the wind cups on to the anemometer rotating shaft.
15 nearby trees, buildings or other structures. • For optimal performance, mount the anemometer at 33 feet (10meters) above the ground in unobstructed area.
16 • Wind direction • Rainfall amount with minimum and maximum memory • UV intensity with daily and weekly highs and lows • 200 weather records without PC connection • PC software (included).
17 Operation Once the main unit is powered, the display will show all available LCD segments for 2 seconds. IMPORT ANT : All of the display functions will be lo cked, allowing setting your local altitude and pressure parameters .
18 Buttons and Controls Most of the handheld remote control buttons are corresponding to the main unit controls. T o expose the main unit control buttons, press the OPEN button o n the upper right corner of the main unit and the controls’ cover door will open.
19 -When depressed and hold in pressure and forecast mode, allows viewing of the different bar charts H. CHANNEL -Changes the temperature and humidity channel -Enables the temperature and humidity channel auto-scan mode I. LIGHT/SNOOZE -Enables a backlight for 5 seconds -Snoozes the alarms Main unit only J.
20 Forecast Button Rain Button -Selects the Rain Mode Sunrise/Sunset Button -Selects the Sunrise/Sunset Mode Clock and Alarm Button -Selects the Clock and Alarm Mode Button -Selects 24 hours History C.
21 using the switch, located on the back panel. NOTE : For an automatic control function the main unit must be plugged into the wall power outlet via the AC/DC adaptor provided. Connecting W eather Station to a Personal Computer T o collect and manipulate data from your weather station you may connect the main unit to the computer via USB cable.
22 Navigating through the modes The main unit has seven (7) different modes (Win dows ) each displaying the separate data category . When a specific mode (Window) is sele cted the corresponding icon will start flashing. Press UP button on the main unit or the handheld remote control to cycle through the modes clockwise or DOWN anti-clockwise.
23 • US Atomic Time clock and calendar • Single alarm, weekday alarm and pre-alarm Sunrise/Sunset Window Displays: • Sunrise and sunset times • Longitude and Latitude T emperature and Humidity.
24 Rain Window Displays: • Current amount of precipitation as well as for the last hour , last day , yesterday , last week and last month • Rainfall alert • Remote rain gauge battery status Wind.
25 Customizing your W eather Station T o use your station, you will have to complete the steps identified under INITIA L SETUP while this section of the manual will provide you with additional operati.
26 or radio station, etc). Accessing Pressure and W eather Forecast Window From the main unit: Press UP or DOWN until the weather forecast icon on the upper left of the display starts flashing.
27 • Set the pressure units by pressing the UP or DOWN arrow buttons • Press MEMOR Y button to confirm your selection • Press and hold SET button until the local pressure digits will fla sh. • Set the sea level pressure by pressing the UP or DOWN buttons to adjust the pressure value.
28 • T o exit, press MEMORY button. Understanding W eather Foreca st Icons Display Weather Forecast Sunny Partly Cloudy Cloudy or Light Rain or Heavy Rain Unstable Weather Snow Note: The weather forecast ac curacy is approximately 70%. Display shows forecasted, not current conditi ons.
29 The current UV intensity is indicated by the numerical value and more intuitive display , by categorizing it into the levels “ LOW”, “ MED ”, HIGH ”, V. H I G H ” an d EXTREME . It is also represented by a comfort icon that corresponds to different levels.
30 Press UP or DOWN button until the clock icon next to the time/date display will flash. From the handheld remote control: Press button. Programming your locatio n IMPORT ANT : There are two options available for programming a location – an auto and manual .
31 Time Zone setting mode (the Tim e Zone data is provided on P .) • Set the T ime Zone by pressing UP or DOWN arrow button to adjust the time in 30 min intervals.
32 • Press ALARM/CHART button to confirm your selection After programming is completed, the display will return to the alarm selection screen. NOTE : Ice W arning Alarm ( PRE-AL ) cannot be set if weekday alarm ( W ) or single alarm( S ) is not enabled.
33 Once the time signal has been successfully received, the time and date will be up dated automatically. T o enable or disable the atomic time receiver: • Press and hold UP - if atomic time reception is activated, a triangular tower icon will start flashing next to the clock icon.
34 displayed in Sunrise/Sunset Window along with the city code. • If you wish to enter the geographical coordinates yourself, select the “USR” (user) as a city code.
35 FULL Sunrise for the previous day FULL Sunset on the following day or later - - - - No sunrise for the whole day - - - - No sunset for the whole day T emperature and Humidity Window The weather station supports up to 5 remote t hermo hygrometers, corresponding to a separate channel of the temperature and relative humidity display .
36 Accessing T emperature and Humidity Mode From the main unit: Press UP or DOWN until the IN icon on the upper right will flash. From the remote control: Press . Viewing Re mote (Channel ) T emperature and Humidity Static Display : In T emperature and Humidity Window , p ress the CHANNEL button every time to recall a different channel.
37 alarm selection screen Viewing Remote T emperature and Humidity Max/Min Readings In the T emperature and Humidity W indow press the MEMOR Y button recalling: • Current temperature and humidity • Minimum temperature and humidity • Maximum temperature and humidity at the remote location.
38 • Rain for the last hour • Rain for the last 24 hours, • Y esterday rain • Last week • Last month. Tip: Fo r the rain rate estimate the Last Hour rainfall value is understood as “inch/hr” or “mm/hr”. Programming Rainfall Amount Units In the Rain Window , press and hold SET button to program the rainfall units in mm or inches.
39 Operating Win d Window In the Wind Wind ow press the SET button to recall: • Wind chill temperature with wind direction in bearings • Wind chill temperature with a wind direction in compass poi.
40 Memory Reset Procedure These steps will completely reset all of the parameters stored in memory . • On the main unit press and hold SNOOZE and UP buttons for 4 seconds until the backlight will flash • Press SET button clearing the memory -the main unit will start beeping with 1 second delay .
41 precipitation measurements. • Detach the protective screen and lid. • Clean with soapy water and a damp cloth, removing dirt, leaves or debris • Clean small holes and parts with Q-tips or pipe-cleaner . • W atch out for spiders or insects that might have crawled into the funnel.
42 few precautions: • Do not immerse the units in water. • Do not clean the units with abrasive or corrosi ve materials. They may scratch the plastic parts and corrode the electronic circuits.
43 Appendix - City Codes US and Canadian Cities City Code Zone DST City Code Zone DST Atlanta, Ga. ATL -5 SU Memphis, Tenn. MEM -6 SU Austin, TX AUS -6 SU Miami, Fla. MIA -5 SU Baltimore, Md. BWI -5 SU Milwaukee, Wis. MKE -6 SU Birmingham, Ala. BHM -6 SU Minneapolis, Minn.
44 Barcelona, Spain BCN 1 SE Dublin, Ireland DUB 0 SE Beijing, China BEJ 8 NO Durban, South Africa DUR 2 NO Belgrade, Yugoslavia BEG 1 SE Frankfurt, Germany FRA 1 SE Berlin, Germany BER 1 SE Glasgow, .
45 DST (Daylight Savings Time) defi niti ons : SA = Australian DST . SB = South Brazilian DST . Changes annually . SC = Chile DST SE = Standard European DST .
46 Humidity (Indoor) Operating Range: 0% to 99% Resolution: 1% Accuracy: 5% Sampling Interval: 10 seconds Humidity (Outdoor) Operating Range: 0% to 99% Resolution: 1% Accuracy: 5% Sampling Interval: 1.
47 Memory size: Ram 128 MB or more Hard disk size: 100 MB free space or more Optical Device: 2 x CD-Rom drive Power Main unit: 4 x UM-3 or AA 1.5V battery; 7.5V AC/DC power adaptor (200mA; center pin positive) Remote Thermo Hygrometer: 2 x UM-3 o r AA 1.
48 protection against harmful interference in a residential installation. This equipment, installed and used in accordance with the instructions, may cause harmful interference to radio communication s. There is no guarantee that interference will not occur in a particular installation.
49 Online Product Registration under the Customer Service menu. Should you require assistance with this product and its operation, please contact o ur Customer Service 1(866) 443 3543.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Honeywell TE923W è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Honeywell TE923W - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Honeywell TE923W imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Honeywell TE923W ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Honeywell TE923W, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Honeywell TE923W.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Honeywell TE923W. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Honeywell TE923W insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.