Manuale d’uso / di manutenzione del prodotto RM7800E del fabbricante Honeywell
Vai alla pagina of 16
INST ALLATION INSTRUCTIONS 66-1085-04 SIL 3 Capable RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES Relay Modules APPLICATION The Honeywell RM7800/R M7840 Relay Modules ar e microprocessor-based integrated burner control s for automatically fired gas, oil, or combination fuel single burner applications.
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 66-1085—0 4 2 WARNING Electrical Shock Hazard. Can cause ser ious injury or d eath. Disconnect the power suppl y before beginning installation. More than one power supply disconnect may be required.
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 3 66-1085—04 a. Do not run high voltage ignition transfo rmer wires in the same conduit with the flame detector , Data Controlbus Module™, or Remote Reset Module wiring.
RM7800E,G ,L,M; R M7840E,G ,L,M 7800 SERIES RELAY MODULES 66-1085—0 4 4 Fig. 1. Internal block diagram of the RM7800L/RM7840L (See Fig. 2, 3, 4 or 5 for individual det ailed wiring instructions).
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 5 66-1085—04 T able 2. Rec ommended Grounding Practices. T able 3. T erminal Ra tings. . a The relay module must have an earth groun d providing a c onnecti on between the subbase a nd the control panel or the equipment.
RM7800E,G ,L,M; R M7840E,G ,L,M 7800 SERIES RELAY MODULES 66-1085—0 4 6 T able 4. Combin ations for T erminals 8, 9, 10 and 21. T able 5. Explan ation of Each Combination.
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 7 66-1085—04 Fig. 2. Wiring subbase and sequ ence for RM7800E,L/RM7840E,L. RM7800/RM7840E,L POWER 00 OPERATING CONTROLS AND INTERLOCKS BURNER.
RM7800E,G ,L,M; R M7840E,G ,L,M 7800 SERIES RELAY MODULES 66-1085—0 4 8 Fig. 3. Wiring subbase and sequence for RM78 00G/RM7840G . M12260B G L2 3 4 5 6 7 8 9 10 F (L1) 13 14 15 16 17 18 19 20 21 22 12 RUNNING INTERLOCKS (INC.
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 9 66-1085—04 Fig. 4. Wiring subbase and sequen ce for RM7800M/RM7840M. M12262A G L2 3 4 5 6 7 8 9 10 F (L1) 13 14 15 16 17 18 19 20 21 22 12 .
RM7800E,G ,L,M; R M7840E,G ,L,M 7800 SERIES RELAY MODULES 66-1085—0 4 10 Fig. 5. RM7800/RM7840 Re lay Module exploded view. SAFETY SHUT DOWN Safety Shut down (Lockout) occurs if any of the followin g occur during the indicated period: 1. INITIA TE Peri od: a.
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 11 66-1085—04 g. Lockout Interlock opens during PREPURGE (RM7840E,L). h. Ignition/pilot valve/intermitt ent pilot valve terminal is energized. i. Main valve terminal is energized. j. Internal system fault occurred.
RM7800E,G ,L,M; R M7840E,G ,L,M 7800 SERIES RELAY MODULES 66-1085—0 4 12 terminal 21. The RM780 0/RM7840G has an interrupted or intermittent pilot valve, terminal 21, depending on the selection of configuratio n jumper 2. The RM7800/RM78 40E,L has a fifteen-second interrupted pilot valve, terminal 21.
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 13 66-1085—04 • Lockout information (Lockout, Faul t Code, Message and Sequence). The extreme right side o f the firs t line is either b la.
RM7800E,G ,L,M; R M7840E,G ,L,M 7800 SERIES RELAY MODULES 66-1085—0 4 14 T able 7. Site Con figurable Jumper Optio ns. a Pilot V alve /First S tage Oil V alve (V alve/S tart) T erminal 21. b A 30 second MFEP can be accomplished by addi ng a jumper wire between T erminals 19 and 5.
RM7800E,G ,L,M; RM7840E,G ,L,M 7800 SERIES RELAY MODULES 15 66-1085—04 T able 8. Static Checkout. T est No. RM7800/ RM7840 Models Te s t Jumpers V oltmeter Normal Operatio n If Operation is Abnormal, Check the Item s Listed Below 1 All None 4-L2 Line voltage at T erminal 4.
RM7800E,G ,L,M; R M7840E,G ,L,M 7800 SERIES RELAY MODULES Automation and Co ntrol Solutions Honeywell Internationa l Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Honeywell RM7800E è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Honeywell RM7800E - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Honeywell RM7800E imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Honeywell RM7800E ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Honeywell RM7800E, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Honeywell RM7800E.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Honeywell RM7800E. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Honeywell RM7800E insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.