Manuale d’uso / di manutenzione del prodotto MS2321 del fabbricante Honeywell
Vai alla pagina of 60
MS2321 / MS2 322 Stratos H ™ Scanner Installation and User’s Guide.
Disclaimer Honeywell Int ernational I nc . (“HII”) r es erves the right t o make changes in s pec ifications a nd other inform ation contai ned in this document without prior notic e , and the reade r s hould in all cas es consult HI I to determine wheth er any such chan ges have been m ad e.
ii T ABLE OF C ONTENTS I NTRODUCTION Manual Scope ........................................................................................................................................................................................ 1 Product Overview .
iii T ABLE OF C ONTENTS Cable Install ation (Seco ndary Honey well Scanner) .............................................................................................................................. 24 EAS Deactivation ............................
1 I NTRODUCTION M ANUAL S COPE This guide p rovides inf ormation on th e installatio n, setup and operat ion of the Strat os H ™ MS23 21 and MS23 22 scan ner models .
2 I NTRODUCTION M ODEL N UMBER D ESIGNATION M ODEL N UMBER D ESIGNATION Figure 1 . Model Number Designation B ASE K IT C OMPONENTS B AS E K IT C OMPONENTS Part # Description MS2 3 21* / MS 2322 * Stratos H Serie s Scanner * See model number d esignation ab ove for detai led informat ion on interfa c e t ype and windo w type.
3 I NTRODUCTION O PT I O N AL A CCE SSORIES Part # Description AC to DC Power Transformer - Regulated Output: +5 V @ 4A +12V @ 1 .5 A 46 - 46812 120V U nited Stat es and C anada 46 - 46813 220V – 24.
4 I NTRODUCTION G ENERAL P RECAUT IONS The follo wing list includes ge neral precaut ions to rem ember when ha ndl ing the Strat os H . D O N OT T URN the unit upsi de down with the pl at ter in place. D O N OT P RESS on the windo w i n the placement plat ter or the verti cal windo w frame.
5 I NTRODUCTION MS2 321 / MS2322 S CANNER D ESIGN S PECI FICATIONS Design Specif ications Operational Light Source: VLD 650 nm Peak Laser Power: <2.2 mW Embedde d Laser: M ax Optical Power: 10 mW Wavelength: 650 nm Horizontal Depth of Field: 0 mm - 152 mm (0"- 6") for 0.
6 B ASE M ODEL C HARACTERI STICS MS2321 Scanner Components Figure 6. MS2321 Components Components I TEM N O . D ESCRIPTION OF I TEM 1 Blue and White LED Indicators ( see page 30 ) 2 Vol ume/T one Mult.
7 B ASE M ODEL C HARACTERI STICS MS2321 Scanner Dimensions Figure 7. MS2321 Dimensions Connector Panel Figure 8. MS2321 Connector Panel Scale ready M S2321 models supply addit io nal connect or s for scale and di splay communi cation cabli ng .
8 B ASE M ODEL C HARACTERI STICS MS2321 Scanner Caution and Serial Number Labels Figure 9. MS2321 Label Locations (Top) and Examples (Bottom) Caution: To maintain complianc e with applicable standards, all circui ts connected to the scanner must meet the requirements fo r SELV (Safet y Extra L ow Voltag e) according to EN/IEC 60950 -1.
9 B ASE M ODEL C HARACTERI STICS MS2322 Scanner Components Figure 10. MS2322 Components Components I TEM N O . D ESCRIPTION OF I TEM 1 Blue and White LED Indicators ( see page 30 ) 2 Volume/T one Mult.
10 B ASE M ODEL C HARACTERI STICS MS2322 Scanner Dimensions Figure 11. MS2322 Dimensions Connector Panel Figure 12. MS2322 Connectors Specifications are subject to change wi thout notice.
11 B ASE M ODEL C HARACTERI STICS MS2322 Scanner Caution and Serial Number Labels Figure 13. MS2322 Label Locations (Top) and Examples (Bottom) Caution: To maintain complianc e with applicable standards, all circui ts connected to the scanner must meet the requirements fo r SELV (Safet y Extra L ow Voltag e) according to EN/IEC 60950 -1.
12 I NSTALLATIO N Q UICK I NSTALLATION O UTL INE The follo wing is a quick prev i ew of the steps required for f ir st time inst all at ions. Each ite m is discusse d in detail later i n this section. • Determine cle arance, venti lation and ser vice access req uirements.
13 I NSTALLATIO N U NPACKING THE U NIT 1. Make sure the s hipping box is t op - side up before ope nin g. 2. Remove the ac cessories bo x and check the bo x’s c ontent for t he following it ems : • Product Manua ls • Power Supply • Communicati on Cables 3.
14 I NSTALLATIO N I NSTALLING THE U NIT IN THE C OUNTER MS2321 Mounting Diagr am (Two Point Support) Figure 18. MS2321 Mounting Dia gram, Two Point Support Specifications are subject to change wi thout notice.
15 I NSTALLATIO N I NSTALLING THE U NIT IN THE C OUNTER MS2321 Mounti n g Di ag r am (Three Point Support) Figure 19. MS2321 Mounting Diagram, Three Point Support Specifications are subject to change wi thout notice.
16 I NSTALLATIO N I NSTALLING THE U NIT IN THE C OUNTER MS2322 Mounting Diagr am (Two Point Support) Figure 20. MS2322 Mounting Dia gram, Two Point Support.
17 I NSTALLATIO N I NSTALLING THE U NIT IN THE C OUNTER MS2322 Mounti n g Di ag r am (Three Point Support) Figure 21. MS2322 Mounting Diagram, Three Point Support Specifications are subject to change wi thout notice.
18 I NSTALLATIO N C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) RS232 The follo wing steps describe h ow to properl y i nstall the cabl es for an RS23 2 Stratos H appl ication . T he scanner must then be configured to match the host’ s RS232 paramet ers.
19 I NSTALLATIO N C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) RS232 xxx * Specifies international connec tion. See Optional Access ories in the Introduction section of this guide for a complete listi ng. See power source caution s tatement on page 11 of this manual.
20 I NSTALLATIO N C ABLE I NSTA LLATI ON (I NTERFACE S PECIFIC ) F ULL S PEED USB The follo wing steps describe h ow to properl y i nstall the cabl es for a Full Spe ed USB Stratos H applicat ion. The sc anner must t hen be configured to match the host’ s USB par amet er s .
21 I NSTALLATIO N C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) F ULL S PEED USB Step 8 is f or USB Ser ial Emulation Mode or Key board Emulation Mo de only.
22 I NSTALLATIO N C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) RS485 The follo wing steps describe h ow to properl y i nstall the cabl es for an RS48 5 Stratos H application. T he scanner must then be configured to match the host’ s RS485 paramet ers.
23 I NSTALLATIO N C ABLE I NSTALLATION (I NTERFACE S PECIFIC ) RS485 xxx * Specifies international connec tion. See Optional Access ories in the Introduction section of this guide for a complete listi ng. See power source caution s tatement on page 11 of this manual.
24 I NSTALLATIO N C ABLE I NSTALLATION (S ECONDARY H ONEYWELL S CANNER ) The follo wing steps describe h ow to properl y i nstall the cabl es bet ween a secondary Hon eywell scann er and the Strat os H . T he Stratos H and t he secondar y sc ann er must then b e configured t o communicate pro perly.
25 I NSTALLATIO N C ABLE I NSTALLATION (S ECONDARY H ONEYWELL S CANNER ) † See Aux power notes on page 24 S ee power source caution s tatement on page 11 of this manual.
26 I NSTALLATIO N EAS D EACTIVATION SW1 and SW2 ar e t he switch banks i nside the Chec k p oint d evic e that set the de ac t ivation range. The follo wing is a list of Chec kp oint recommended s witch bank se t tings.
27 S CANNER O PERATION S CAN Z ONE Figure 28. Checker-Side (13 mil) Figure 29. Horizontal Left/Right (13 mil) Specifications are subject to change wi thout notice.
28 S CANNER O PERATION S CAN Z ONE Fig ure 30. Horizontal Direct (13 mil) Figure 31. Vertical Direct (13 mil) Specifications are subject to change wi thout notice.
29 S CANNER O PERATION IR A CTIVATION A REA (IR LED O UT PUT ) The Strat os H ’s default po wer save mode † is Dual Ac t ion Power S ave Mode #2 (see pag e 34 ) . T his power save mod e † turns the laser OFF after a confi gur ed period of non - use then tur ns the motor OFF after thirty - minute inter vals .
30 Figure 33. LEDs S CANNER O PERATION I NDICATOR D ESCRIPT IONS Audible When in operat ion the Stratos H provide s aud ible feedback t hat indicates t he status of t he unit and the cu rrent scan . Eight settings are availabl e for the tone of t he beep (norma l , six alternate tones a nd no tone) plus t hree volume set tings.
31 S CANNER O PERATION I NDICATOR D ESCRIPT IONS Visual Steady Whit e and Blue After a succes s f ul scan, the scann er transmit s t he data to the host d evice. Some com m unication mod es require t hat the host inform the scanner when data is ready to be rec eived.
32 S CANNER O PERATION I NDICATOR D ESCRIPT IONS Diagnosti c I ndicator Disp l ay There is a t wo - digit error code displ ay located under the platt er near the end of the scann er farthest f rom the vertical window (see fig ure be lo w) . Figure 34.
33 S CANNER O PERATION I NDICATOR D ESCRIPT IONS Diagnosti c I ndicator Disp l ay E RROR C ODE D ESCRIPTION 11 SWIT CH ERROR – The switch used f or volume selec t ion or sleep mode is detected in e rror (always cl osed) . The c ondition is self - correcting if possible .
34 S CANNER O PERATION P OWER S AVE M ODES The Strat os H has five config urable po wer s av e modes. Refe r t o the MetroSelect Configura tion Guide ( PN 00 - 0240 7 x ) for additiona l i nformation on Power Save Modes . 1. Blink Pow er Save Mode: Blinks the laser OFF & ON after a conf igured per iod of non - use.
35 S CANNER O PERATION B EEPER O PTIONS AND B UTTO N F UNCTIONS Changing the Beeper Tone Beeper tones m a y be configured inc r ementall y usi n g the follo wing bar code. T he ne w tone will be hear d f ollowed by a s hort pause. Two more new t ones will be heard s i gnifying t he new setting has been stored in m emory.
36 S CANNER O PERATION S TARTU P When the scan ner first receives po wer the white LE D will flash, t he blue LED will tur n on and the scann er will beep on ce ( the white LED will remain on f or the duration of the beep ). The sc anner is now read y to scan.
37 M AINTENANCE P LATTER / H ORIZONTAL S CAN W INDOW R EPLACEMENT Figure 39. Platter/Hori zontal Scan Window Replacement* * See replacement parts on page 3.
38 M AINTENANCE V ERTICAL S CAN W INDO W R EPLACEMENT ( PN 46 - 46889 ) Figure 40. Vertical Scan Wi ndow Replacement D AILY M AINTENANCE Smudges and dirt can interfere with the proper s c anning of a bar cod e. Therefore, t he horizonta l and vertic al out p ut windo w s will need occasional c le aning.
39 T ROUBLESHOOTING The follo wing guide is for ref erence purposes only. Contact a customer service repr esentati ve to preserve t he l im ited warrant y terms. Symptom Possible Cause(s) Soluti on All Interfaces No LEDs, beep or motor spin. No po wer is being suppli e d to the scanner.
40 T R OUBLESHOOTING Symptom Possible Cause(s) Soluti on All Interfaces Scanner beeps at some bar codes and NOT for others of the same bar code symbology. Check the char acter length lock. Check if it is a ch eck digi t , character or bor der problem.
41 T ROUBLESHOOTING Symptom Possible Cause(s) So lution Aux Port Operat i on W ith Any Int er face The secondar y s canner is not functionin g. Refer to the us er’s guide pr ov ided with the s e condary scan ner. The secondar y s canner powers up but dat a is not relayed to the host.
42 S CANNER AND C ABLE T ERMINATIONS S CANNER P INOUT C ONNECTIONS The Strat os H scanner termina te s to 10 - pin modu lar jacks lo cated on the bot tom of the unit . The serial num ber label indic at es the model number and i nterfa ce of t he scanner.
43 S CANNER AND C ABLE T ERMIN ATIONS S CALE R EADY MS2321 M ODELS – A DDITIO NAL P I NOUT C ONNECT IONS There are four additional 10 - pi n modular jack s located on th e bottom of the of the MS2321 Stratos H model s that may be used f or an integrated sca le applicati on and the use of a remote displa y .
44 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C ONFIGURATIONS The follo wing cables are exa mples of some of t he standard c ables that may be ship ped with the S tratos H sc ann er. Please keep in mind that every a pplication is unique and th e c ables received with the Strat os H may be cust om cables that ar e not shown below.
45 S CANNER AND C ABLE T ERMINATIONS C ABLE C ONNECTOR C O NFIGURA TIONS Aux Port Confi guration Cabl e *, PN 57 - 57008 x -N-3 Pin Function ** 9-Pin D- Type Connector 1 No Connect 2 Output from Scann.
46 R EGULATORY C OM PLIANCE S AFETY ITE Equipment IEC 60950 -1 Sec on d Edition EN 60950 -1 Sec ond E dition Laser Laser Class 1: IEC 60825 - 1: Se cond Edition 2007 EN 60825 - 1: Secon d E dition 200.
47 R EGULATORY C OM PLIANCE EMC Emissions FCC Part 15, I CE S - 003, CISPR 22, EN 55022 Immunity CISPR 24, EN 550 24 Note : Immunit y performanc e i s not guarante ed for scanner cables great er t han 3 meters in len gth when fully e xte nded.
48 R EGULATORY C OM PLIANCE EMC Changes or modif ications not expressly a ppr oved by the pa r ty responsible for compliance could void t he user’s aut hor i t y to operate the equipment . Class B Devices The follow ing is applicabl e w hen the scanner cab l e is less than 3 meters (9.
49 L IMITED W ARRANTY Honeywell Int ernat ional Inc. ("HI I ") warrants its products and option al accessories to be free from defect s in material s an d workmanship and t o conform to HII ’s published specif ications applicable to t he products purchased at the time of shipment.
50 I NDEX A AC ............................................................................. see pow er application .............................................................................. 32 audible .............................................
51 I NDEX T test ......................................................................................... 36 tone .......................................................................... 6, 9, 30, 35 transformer ....................................
52 C USTOMER S UP PORT T ECHNICAL A SSISTANCE If you need assi s t ance install in g or troublesh ooting your dev ice, pleas e contact us b y using one of the met hods belo w: Knowledg e Base: www.hsmkno wledgebase.c om Our Knowledg e B as e provides t housands of immedi ate solut i ons .
53.
.
.
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00 - 02270 Rev G 8 /12.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Honeywell MS2321 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Honeywell MS2321 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Honeywell MS2321 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Honeywell MS2321 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Honeywell MS2321, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Honeywell MS2321.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Honeywell MS2321. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Honeywell MS2321 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.