i i P P G G S S M M - - C C O O M M C C o o m m m m e e r r c c i i a a l l F F i i r r e e C C o o m m m m u u n n i i c c a a t t o o r r I I n n s s t t a a l l l l a a t t i i o o n n a a n n d d S S e e t t u u p p G G u u i i d d e e iPGSM-COM Commercial Fire Comm unicator RADIO TROUBLE LO W BA TT AC O N A C LOSS 800-04433V1 12/10 Rev.
Contents General Info rmation ............................................................................................................ ...........1 Package Contents ..................................................................................
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 1 – General Information The iPGSM-COM Co mmercial Fire Co mm unicator includes everything yo u need to upgr ade a commerci.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 2 – STEP 1 – Activate the SIM and Setup the Customer Account The communicator requires a subscriber account (customer account) to be setup with AlarmNet Dir ect. This is accomplished by registering th e communicator' s iGSM communications m odule with AlarmNet.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 3 – STEP 3 – Determine the Signal Strength and Select a Location IMPORTANT - Do Not mount this de vice outdoors. When choosing a suitable mounting location, understand that signal stren gth is very important for proper operation.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 4 – Note: Refer to the diagram on page 5, and to the Wiring Di agram on the inside of th e back cover of this manual for all wiring information. 5. Mount the Wall Outlet Box to an un-s witched facility power outlet and run a conduit to the cabinet.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 5 – iPGSM-C0M-001-V0 TB 1 6 7 8 5 10 11 9 2 3 4 1 FOR EXTERNAL ANTENNA 50 OHM MMCX ONLY PRIMARY POWER: 9 - 16.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 6 – STEP 5 – Program the Communications Module You must use the 7720P Programming tool to program the iPGSM-CO M. When using the 7720P P rogramming tool, the valu es given below are for most instal lations.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 7 – STEP 6 – Configure the Fire Panel 1. Ensure the Telco F ault on the panel is enabl ed. Then choose a setting that is no higher than 90 seconds (or as close to that) as the panel allows.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 8 – Dialer Capture Mo dule Information LED Indicator STATUS RED – Steady ON Messages exist in buffer. RED – Flashing No messages to be sent. Waiting for messages. GREEN – Steady ON Normal Indication.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 9 – PowerBoost1 Module Information LED Indicator STATUS AC (green) AC power available. ACTIVE (green) Cyclical flashing – normal communicati ons. Repetition of 3 flashes – loss of communications.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 10 – iGSM Communications Module Information TB 1 6 7 8 5 10 11 9 2 3 4 1 PRIMARY POWER: 9 - 16.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 11 – iPGSM-COM Specifications ITEM SPECIFICATION Cabinet Dimensions: Width = 12 3/4 inches Height = 14 7/8 inches Depth = 3 inches Transformer: (N8167) Primary – 120VAC, 60Hz, 0.
iPGSM-COM Commercial Fire Communicator – Installation and Setup Guide – 12 – NOTES.
Wiring Diagram The wiring diagram below is depict ed for point-to-point electrical con nection checks used for tr oubleshooting or componen t replacement. It is not intend ed to show the phys ical routing of wires. When replacing a wire or componen t, ensure the wire is route d in the same manner as the orig inal factory wire.
FCC STATEMENT Note: This equipment has been tested and foun d to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits ar e designed to prov ide reasonable pr otection against harmful i nterference when the equipment is operated in a commerci al environment.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Honeywell 800-04433V1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Honeywell 800-04433V1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Honeywell 800-04433V1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Honeywell 800-04433V1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Honeywell 800-04433V1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Honeywell 800-04433V1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Honeywell 800-04433V1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Honeywell 800-04433V1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.