Manuale d’uso / di manutenzione del prodotto 69-2072-05 del fabbricante Honeywell
Vai alla pagina of 24
Owner ’ s Guide True IAQ ® Di gita l I A Q Co ntr o l 69-2072-05 69-2072_C.indd 1 7/31/2008 2:04:24 PM.
User Information About T rueIAQ ® .............................. 1 Operation .................................... 2 Display screen reference ........... 3 Adjusting IAQ setting s Changing humidifier settings ..... 4 Changing dehumidifier settings ...
1 69-2072—05 The T rueIAQ ® monitors and automatically adjusts operation of your whole-house humid- ifier , dehumidifier , ventilator , or bath fan. Maintaining proper indoor humidity minimizes the potential for unhealthy airbor ne pol- lutants to grow .
69-2072—05 2 T rueIAQ ® can be used to control the humidity levels in your home, and control fresh air intake in accordance to industry recommendations (ASHRAE 62.2). Operat ion 68 40 55 12 15 : 76 % % In Out PM M24931 Comfort Settings: Feedback on your indoor IAQ conditions.
3 69-2072—05 Dry: Indoor humidity levels are below 20% relative humidity (RH.) Display screen reference 68 40 55 12 15 : 76 % % In Out PM M24932 W et: Indoor humidity levels are above 60% RH. Window Frost: The control is protecting your home against too much humidity based on outdoor conditions.
69-2072—05 4 Outdoor T emp. Sett ing -20°F (-29°C) 15% 0°F (-18°C) 25% 20°F (-7°C) 35% Changi ng humidi fier set tin gs Note: These items will appear only if a humidifier is installed on your system. 1. Set humidifier by pressing UP/DOWN arrows.
5 69-2072—05 2. Press “More” to enter Window Frost Protection. Use the UP/DOWN arrows to set frost protection level. Changi ng humidi fier set tin gs M24830 12345678 9 LESS HUMIDITY LOOSE HOME/S.
69-2072—05 6 Note: These items will appear only if a dehumidifier is installed. If both a humidifier and dehumidifier are installed, these settings will appear after pushing “More” from the humidifier operation style screen. Changi ng dehu midifier an d ventilat ion set tin gs 1.
7 69-2072—05 1. Press “More.” Adjust hour using the the UP/DOWN arrows. 2. Press “More.” Adjust minutes using the UP/DOWN arrows. 3. Press “Done” to save settings.
69-2072—05 8 Installation 1. T urn system power off. 2. Choose a location. T rueIAQ ® can be mounted to a wall or directly to the return duct. CA UTION: EL ECT RIC AL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before beginning installation.
9 69-2072—05 Installation 3. Loosen the cover screw . 4. Separate the front housing from the base. M24814 5. For wall mounting, run wires through the back hole to the terminals. Wire size for all connectors: 2 x 18 AWG to 1 X 22 AWG. Install the mounting plate using two screws.
69-2072—05 10 Pin Pin description Pin capacity R 24V supply . Must be common to G output. 24V ac±20% 1.5 amp max C 24V supply common. 24V ac±20% Sensor Communication and supply bus to remote sensors (sensor pins not polarized). 24Vdc 64mA max out Sensor Switch Override switch input.
11 69-2072—05 Wiring Wiring T rueIAQ ® with a non-powered humidifier . HV AC THERMOST AT M27340 68 40 55 12 15 : 76 % % In Out PM R C W Y G R C SENSOR SENSOR SWITCH W G VENT VENT DEHUM DEHUM HUM HUM 24V TRANSFORMER HE225 BYP ASS HUMIDIFIER TrueIAQ + – 69-2072_C.
69-2072—05 12 Wiring HV AC THERMOST AT HUM HUM 24V 24V G Y W RR c G Y W RC 24V 24V HUM HUM C GT R RT GF EXT RECOMMENDED PRESSURE SWITCH M27341 TrueSTEAM - INTERNAL NOTE: IF PRESSURE SWITCH IS USED, ENSURE DIP 5 IS IN ON POSITION. FA CTORY INST ALLED JUMPER 68 40 55 12 15 : 76 % % In Out PM Tr ueIAQ Wiring T rueIAQ ® with a powered humidifier .
13 69-2072—05 Wiring M27390 68 40 55 12 15 : 76 % % In Out PM R C SENSOR SENSOR SWITCH W G VENT VENT DEHUM DEHUM HUM HUM TrueIAQ EARD-6 TH81 10 U Y W RR c OUTDOOR SENSOR (PROVIDED) HV AC R C W Y G CG DH90 DEHUMIDIFIER GRA Y DAMPER CONTROL (NOT USED) RED +24 VA C POWER YELLOW COMPRESSOR CONTROL COMM.
69-2072—05 14 Wiring M27391 68 40 55 12 15 : 76 % % In Out PM R C SENSOR SENSOR SWITCH W G VENT VENT DEHUM DEHUM HUM HUM Tr ueIAQ TH81 10U Y W RR c OUTDOOR SENSOR (PROVIDED) HV AC R C W Y G CG RED B.
15 69-2072—05 Wiring Wiring T rueIAQ ® with a non- powered humidifier , ventila- tion damper , and an auxiliary exhaust fan. 2 IF A THERMOST AT OTHER THAN A TH51 10, TH5220, TH5320, TH61 10, TH6220, TH6320, TH81 10, TH8320 OR TH8321 IS USED, A RELA Y MA Y BE REQUIRED TO ISOL AT E THE G WIRE.
69-2072—05 16 Mounting t he outdoor se nsor 1. Do not mount on the south side of the house or in direct exposure to sunlight. 2. Keep at least 4 feet away from exhaust vents. 3. If in an air intake, place 1 foot closer to outside wall. 4. Place at least 6 inches higher than possible snow buildup.
17 69-2072—05 Advanced H V AC i nstaller setup in str uctio ns 1. Press and hold the UP/ DOWN arrows for 3 seconds. M24823 2. Press “More” to advance to the next setup option. See table on next page. 3. Use the UP/DOWN arrows to select options. See table on next page.
69-2072—05 18 Adv anced programming Setup functions Se t ti ng s & O pt i on s (factor y default in bold ) 10 T emperature Display 1=Fahrenheit; 2=Celcius 15 Frost Protection 0=Not installed 1=F.
19 69-2072—05 Adv anced programming Setup functions Se t ti ng s & O pt i on s (factor y default in bold ) 85 Hum Service Timer 0 ,1,3,6,12 (months intermittent) 90 Hum Water Filter Service 0 ,1.
69-2072—05 20 Adv anced programming Setup functions Se t ti ng s & O pt i on s (factor y default in bold ) 150 ASHRAE: CFM Setting 3=30 CFM; 4=40 CFM, up to 20=200 CFM 155 Maximum V ent 00 ; 30%–95%.
21 69-2072—05 T rueIAQ ® Control and Outdoor Sensor • Operating/Storagetemp: -40°F to 120°F (-40°C to 50°C) • CondensationProtection: 0-100% • OperatingRH%: 0% to 99%non- condensing (T rueIAQ). Outdoor sensor protected from condensation.
Honeywell Inter national Inc. 1985 Douglas Drive North Golden Valley , MN 55422 http://yourhome.honeywell.com ® U .S. Registered T rademark. © 2008 Honey well International Inc. Patents pending. 69 -2072 — 0 5 M .S . R ev. 07-0 8 Automa tio n an d Cont r ol So lut ions Printed in U.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Honeywell 69-2072-05 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Honeywell 69-2072-05 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Honeywell 69-2072-05 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Honeywell 69-2072-05 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Honeywell 69-2072-05, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Honeywell 69-2072-05.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Honeywell 69-2072-05. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Honeywell 69-2072-05 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.