Manuale d’uso / di manutenzione del prodotto SL-550TRSI-AUE del fabbricante Heat & Glo
Vai alla pagina of 40
1 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 MODEL: SL-550TRSI-AUE AUSTRALIAN GAS ASSOCIA TION APPROVED Approval Number 5666 THIS MANUAL MUST BE USED FOR INST ALLA TION AND RET AINED BY HOMEOWNER FOR OPERA TION AND MAINTENANCE. HEA T & GLO, a brand of Hearth & Home T echnologies Inc.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 2 IMPORT ANT : Read all instructions carefully before starting inst allation. Failure to follow these installation instructions may result in a possible fire hazard and will void the warranty .
3 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 T ABLE OF CONTENTS 1.0 Installation Instructions ......................................................................................... 5 1. 1 Introduction ..........................
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 4 Figure 1. Diagram of SL-550TRSI-AUE 25-3/4 i n . (653m m) 12-7 /8 in. (327m m) 15-7/8 i n . (402m m) 16-3 /8 i n. (414m m) 8- 3/4 in . (223m m) Ø 8 2 in. (20 3m m) 36-3 /8 in . (92 4m m) GAS LI N E ACCESS 6 in.
5 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 2. Fireplace Dimensions, Locations, and Space Requirements Minimum Clearances from the Fireplace to Combustible Materials Inches mm Glass Front ..................................
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 6 Figure 3. Framing Dimensions Framing should be constructed of 2 X 4 lumber or heavier . The framing headers may rest on the fireplace stand-offs. AB C D * E * 37 in. 33-1/4 in. 16-1/2 in.
7 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal. 2. Prohibited area below electricity meter or fuse box extends to ground level.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 8 TABLE 1 1.2 FLUE SYSTEM APPROV ALS These models have flue starting collars on both the top and the back of the unit. Depending upon the installa- tion, decide which ONE set of starting collars will be used to attach the flue system.
9 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 NOTE: PIPES OVERLAP 32mm A T EACH JOINT . D V P 9 0 S T 319mm 286 mm 184 mm 32mm T Y P 13mm TYP 217mm DVP36 DVP48 1219mm 610 mm 914 mm 102mm 152m m DVP4 DVP6 305mm DVP12 51mm MIN. DVP12A 310 mm MAX.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 10 Figure 7. SL D-Series Balanced Flue Component Specifications (4-inch (102mm) inner pipe / 6 5/8-inch (168mm) outer pipe) NOTE: PIPES OVERLAP 1 3/8 INCHES (35mm) A T EACH JOINT .
11 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 VERTICAL FLUEING V FT . (M) 36' MAXIMUM (10.97M) Figure 9. USE SL D-SERIES COMPONENTS ONL Y .
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 12 Figure 1 1. V H FT . (M ) FT . (M ) 1' MIN.(0.30M) 2' MAX.(0.61M) 2' MIN.(0.61M) 4' MAX.(1.22M) 3' MIN.(0.91M) 8' MAX.(2.44M) 4' MIN.(1.22M) 10' MAX.
13 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 13. V H FT . (M) FT . (M ) 1' MIN.(0.30M) 2' MAX.(0.61M) 2' MIN.(0.61M) 4' MAX. (1.22M) 3' MIN.(0.91M) 6' MAX. (1.83M) 4' MIN.(1.22M) 8' MAX.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 14 V H H 1 Figure 14. USE DVP-SERIES COMPONENTS ONL Y . FLUEING WITH TWO (2) 90° ELBOWS V H H + H 1 1´ MIN. (0.30M) 1´ MAX. (0.30M) 2´ MAX. (0.61M) 2´ MIN. (0.61M) 2´ MAX. (0.61M) 4´ MAX.
15 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 FLUEING WITH THREE (3) 90° ELBOWS V H H + H 1 FT . ( M) FT . ( M) FT . ( M) 2' MIN.(0.61M) 2' MAX.(0.61M) 4' MAX.(1.22M) 3' MIN.(0.91M) 3' MAX.(0.91M) 6 ' MAX (1.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 16 Figure 16. FLUEING WITH THREE (3) 90° ELBOWS 1´ MIN. (0.30M) 1´ MAX. (0.30M) 3´ MAX. (0.91M) 2´ MIN. (0.61M) 2´ MAX. (0.61M) 5´ MAX. (1.52M) 3´ MIN. (0.91M) 4´ MAX. (1.22M) 8´ MAX.
17 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 17. WARNING: F AILURE TO REMOVE INSULA TION IN THE SET OF COL- LARS YOU ARE USING COULD CAUSE A FIRE. WARNING: THE REAR FLUE COL- LAR SEAL CAP MUST REMAIN A T - T ACHED T O THE REAR FLUE COL- LARS IF THE FLUE SYSTEM IS A T - T ACHED T O THE TOP ST ARTING COLLARS.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 18 ! W ARNING: ENSURE THA T THE HEA TER GASKET SUPPLIED WITH THE HEA TER SEALS BETWEEN THE FIRST FLUE COMPO- NENT AND THE OUTER HEA TER WRAP . Fire Risk Exhaust Fumes Risk Impaired Performance of Appliance • Overlap pipe slip sections at least 38 mm.
19 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 2. Continue Adding Flue Components T o continue adding flue components in accordance with the pre-planned flue system configuration: • Ensure that each succeeding flue component is se- curely fitted and locked into the preceding compo- nent in the flue system.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 20 For V ertical Runs The flue system must be supported every eight (8) feet (2.4 M) above the heater flue outlet by wall brackets.
21 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 ! Figure 26. Ceiling Firestop (Ceiling Side) If the area above the ceiling IS an attic, position and secure the firestop on top of the previously framed hole.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 22 For V ertical T erminations - T o locate the flue and install the flue sections: • Locate and mark the flue centerpoint on the under- side of the roof, and drive a nail through the centerpoint.
23 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 30. IGN IT IO N MOD ULE (6V) ON/OFF WA LL S W IT C H VA LV E FLAME SP ARKER/ SENSO R ANT .
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 24 Figure 31. NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE 105 • C RA TED WIRE.
25 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 Figure 33. 1.6 FINISHING The minimum clearance to combustibles are 0 from the sides, floor , back and top (these clearances are defined by the standoffs). The minimum distance to the perpendicular side wall extending past the appliance front is 2-inches (51mm).
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 26 Figure 34. Figure 35. MAKE SURE THE FLAMES ARE STEADY—NOT LIFTING OR FLOA TING . Inst alling the T rim Combustible materials may be brought up to the specified clearances on the side and top front edges of the fireplace, but MUST NEVER overlap onto the front face.
27 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 CAUTION: Logs are fragile! Carefully remove the logs from the packaging. LOG #1 (SRV550-715): Place log #1 onto the log grate so that the notches in the bottom of the log fit on the right three grate bars.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 28 LOG #4 (SRV278-705): Position log #4 between log #1 and the locating tab on the fourth grate bar .
29 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 LOG #7 (SRV484-703): Place log #7 on the groove in log #2 with its rear top on log #1 and front top resting on log #5. LOG #8 (SRV347-701): Hook log #8 on the right hand corner grate bar and rest its rear on log #1 as shown.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 30 ! ! Figure 36. 2.0 OPERA TING INSTRUCTIONS This appliance is a balanced flue heater and is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases ex- pelled to the outside of the building.
31 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 2.1 SAFETY & LIGHTING INFORMA TION Follow SAFETY INFORMA TION and LIGHTING IN- STRUCTIONS to light the appliance. By design, the flame pattern will not be identical from unit to unit.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 32 ! 2.2 F AN OPERA TION The accessory fan is wired in series with a speed con- trol switch and a temperature sensor switch. Set the speed control to an "ON" position and light the heater .
33 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 3.1 REMOV AL OF COVERS FOR SERVICING A . Control Compartment Door • Rotate the lower door down to access the gas controls. B . Dress Guard and Glass Door • Lift the front dress guard up and out away from the appliance side surrounds.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 34 I nspect Mai n tenance T asks Doors 1. I n spect for scrat ch es, den t s or ot h er damage an d r e pai r as n ecessar y . 2. V e r i f y n o o bs t r u c t i on s t o a i r f l ow . 3.
35 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 3.6 TROUBLESHOOTING With proper installation and maintenance, your new Gas Heater should provide years of trouble-free service. If you do experience a problem, refer to the T rouble Shooting Guide below .
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 36 Electronic Ignition System - (continued) Sym pt om P o s s ib le C a u s e s Co rrect ive A cti o ns 10. G lass soot s. a. Fl ame impin gemen t on lo g s . A d just the lo g s e t s o that the fla me d o e s not i mp i ng e o n i t .
37 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 (NG , LP) Exploded Parts Diagram Service Parts SL-550TRSI-AUE Beginning Manufacturing Date: 6/06 Ending Manufacturing Date: ______ 22.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 38 SL-550TRSI-AUE Service Parts List IMPORT ANT : When ordering, supply serial and model numbers to ensure correct service parts.
39 Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 LIMITED 10 YEAR WARRANTY HEAT & GLO, a brand of Hearth & Home Technologies Inc.
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev . B • 7/06 40 For Service or Replacement Part s Cont act: Melbourne Jetmaster 444 Swan S treet Richmond 3121 (03) 9429-5573 Perth Fireplace Corner .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat & Glo SL-550TRSI-AUE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat & Glo SL-550TRSI-AUE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat & Glo SL-550TRSI-AUE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat & Glo SL-550TRSI-AUE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat & Glo SL-550TRSI-AUE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat & Glo SL-550TRSI-AUE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat & Glo SL-550TRSI-AUE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat & Glo SL-550TRSI-AUE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.