Manuale d’uso / di manutenzione del prodotto COSMO-I35 del fabbricante Heat & Glo LifeStyle
Vai alla pagina of 40
1 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Models: Cosmo-I30 Cosmo-I35 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________.
3 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 4 B. Limited Lifetime W arranty.
5 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 B. Limited Lifetime W arranty (continued).
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 6 C. BTU Speci fi cations MODELS: Cosmo-I30, Cosmo-I35 LABORA TOR Y : Underwriters Laboratories, Inc.
7 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 8 C. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
9 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 I. Before Lighting Fireplace Before operating this fi replace for the fi rst time, have a quali fi ed technician : • V erify all shipping materials have been removed from inside and/or underneath the fi rebox.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 10 J. Lighting Instructions (IPI) The IPI system may be operated with four AA-cell batteries. When using batteries, unplug the transformer . T o prolong bat- tery life, remove them when using the transformer .
11 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Initial Break-in Procedure • The appliance should be run three to four hours continuously on high. • T urn the appliance off and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 12 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
13 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 V enting Frequency: Seasonally By: Homeowner T ools needed: Protective gloves and safety glasses. • Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow , debris, etc.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 14 Burner Ignition and Operation Frequency: Annually By: Service T echnician T ools needed: Protective gloves, vacuum cleaner , whisk broom, fl ashlight, voltmeter , indexed drill bit set, and a manometer .
15 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual VERTICAL TERMINA TION CAP (SECTION 8.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 16 B. Design and Installation Considerations Heat & Glo gas inserts are designed for installations into solid fuel masonry or factory built fi replaces that have been installed in accordance with the National, Provin- cial, State and local building codes.
17 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 5 5 F ireplace Size Requirements Figure 5.1 Fireplace Opening In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 18 B. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
19 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ..................
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 20 7 7 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation.
21 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 B. V enting Components CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 22 Figure 8.2 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE • T rim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2). • Place 3/8 inch bead of 300º F silicone on fl ue tile top.
23 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 F . Installing Adaptor and T ermination Cap For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 8.4) . T o install adaptor see Figure 8.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 24 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a quali fi ed technician (NFI certi fi ed or factory-trained) using Hearth & Home T echnologies speci fi ed and approved parts.
25 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 26 Figure 10.2 Fan Wiring Diagram BLOWERS BLOWER RECEPT ACLE BLK GRN BLK BLK GRN BLK WHT GRN BLK BLK GRN WHT BLK BLK BLK BLK PLUG.
27 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 PLUG 120V EXISTING OUTLET GRN (2) BLK (2) BLK (2) GRN (2) BLK (2) STEPS 3 & 4 WHT (2) BLOWER SPEED CONTROL (RHEOST A T) SE.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 28 1 1 11 Finishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as speci fi ed. Framing or fi nishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.
29 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 A. Remove Glass Assembly See Section 12.F . B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity .
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 30 G. Air Shutter Setting Air shutter settings should be adjusted by a quali fi ed ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run.
31 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 1 3 13 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 32 IntelliFire Plus™ Ignition System (continued) Symptom Possible Cause Corrective Action 4.
33 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 1 4 14 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 34 B. V ent Kits Components Direct V ent Flex Liner Kits (see Figure 14.2) LINK-DV -30B or (LINK-DV -30): Masonry 3 inch fl ex liner kit. Expands to 30 feet. Includes: two liners, termination cap, fl ashing, and link adapter .
35 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 C. Service Parts COSMO-I30 Beginning Manufacturing Date: June 2010 Ending Manufacturing Date: ______ Part number list on following page.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 36 C. Service Parts List COSMO-I30 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
37 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 C. Service Parts Beginning Manufacturing Date: June 2010 Ending Manufacturing Date: ______ COSMO-I35 Part number list on following page.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 38 C. Service Parts List COSMO-I35 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
39 Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 Service Parts COSMO-I30, COSMO-I35 Beginning Manufacturing Date: June 2010 Ending Manufacturing Date: ______ 3 4 5 6 7 8 9 10 11 12 13 14 1 2 #12 IPI V alve Assembl y IMPORT ANT : THIS IS DA TED INFORMA TION.
Heat & Glo • Cosmo-I30, Cosmo-I35 • 2239-900 Rev . H • 1/1 1 40 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat & Glo LifeStyle COSMO-I35 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat & Glo LifeStyle COSMO-I35 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat & Glo LifeStyle COSMO-I35 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat & Glo LifeStyle COSMO-I35 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat & Glo LifeStyle COSMO-I35, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat & Glo LifeStyle COSMO-I35.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat & Glo LifeStyle COSMO-I35. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat & Glo LifeStyle COSMO-I35 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.