1 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Models: 350TRSI-AUF 350TRSILP-AUF Owner ’ s Manual Installation and Operation • DO NOT USE OR STORE FLAMMABLE MA TERIALS NEAR THIS APPLIANCE. • DO NOT SPRA Y AEROSOLS IN THE VICIN- ITY OF THIS APPLIANCE WHILE IT IS IN OPERA TION.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 2 M O D E L S: 3 50 T RS I -A UF , 35 0T RS IL P- AU F ARE SAI GLOBAL APPROVED FOR NA TU RAL GAS, PRO P ANE OR BUT ANE AS A BALANCED FLUE HEA TER. Refer to the appliance data plates for gas consumptions and pressures.
3 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: _____.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 4 FOR YOUR SAFETY This appliance is designed to operate on LPG IF YOU SMELL GAS: • T urn off as supply at bottle • Exti.
5 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 6 = Contains updated information. B. IntelliFire Plus™ Ignition System Wiring . . . . . . . . . . . . . 54 C. Optional Accessories Requirements . . . . . . . . . . . . .
7 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 AUSTRALIAN W ARRANTY INFORMA TION W arranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below .
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 8 W arranty Period Heat & Glo Manufactured Appliances and V enting Components Covered Parts Labor Gas Wood Pellet EP A .
9 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 • Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing replace system in which an insert or a decorative gas appliance is installed.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 10 A. Appliance Certication 1 Listing and C ode Approv al s MODELS: 350TRSI-AUF , 350TRSILP-AUF LABORA TORY : SAI Global TYPE: Gas Space Heating Appliance ST ANDARD: AS4553:2008 C.
1 1 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate replace before read - ingand understandingoperating instructions.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 12 D. Clear Space W ARNING! DO NOT place combustible objects in front of the replace or block louvers. High temperatures may start a re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
13 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 I. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait ve (5) minu tes to cle ar out any gas.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 14 Not e: If t he module is in LOCK- OUT mode, reset ting the cir cuit br eaker to the app lianc e will al so reset t he mod ule.
15 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 K. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the replace off and allow it to completely cool.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 16 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle xed glass assembly with care.
17 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 B. Maintenance T asks-Qualied Service T echnician The following tasks must be performed by a qualied ser- vice technician.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 18 A. T ypical Appliance System NOTICE: Illustrations and photos reect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale.
19 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to op - erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside of the building.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 20 5 F raming and C learances A. Selecting Appliance Location Whe n sel ect ing a loca tio n for th e app lia nce it is imp ort an t to con sid er the r equ ire d c lea ra nce s t o w all s (se e F igu re 5.
21 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 22 Figure 5.3 Clearances to Combustibles NOTE: FRAME OPENING HEIGHT IS GREA TER THAN PLASTER OPENING HEIGHT . E 1 in. (25 mm) H G J F I C B D A * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 in.
23 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 D. Mantel and W all Projections W AR NI NG! R isk o f F ir e! Co mp ly w it h al l m in imu m cle ar - an ces a s spe ci ed.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 24 A. V ent T ermination Minimum Clearances Figure 6.1 Minimum Height From Roo f T o Lowest Discharge Opening 6 T er mination Locations Fire Risk. Maintain vent clearance to combustibles as specied.
25 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 6.3 Minimum Clearances for T ermination NOTES: 1. All distances are measured vertically or horizontally along the wall to a point in line with the nearest part of the terminal.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 26 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP and SLP venting systems. Refer to Section 16.B for vent component information.
27 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 7.4 T op V ent - Horizontal T ermination Note: A 6 in. (152 mm) section of straight ue must be attached to the heater before a 90° elbow . Fire Risk. Explosion Risk.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 28 T op V ent - Horizontal T ermination - (continued) Figure 7.5 T wo Elbows V 1 Minimum H 1 + H 2 Maximum Elbow only Not allowed 6 in. 152 mm 1 ft. 305 mm 1 ft. 305 mm 2 ft.
29 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 T op V ent - Horizontal T ermination - (continued) Figure 7.6 Three Elbows V 1 Min. H 1 Max. V 2 Min. H 2 Max. 6 in. 152 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm 1 ft. 305 mm 2 ft.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 30 T op V ent - V ertical T ermination This model is approved to use DVP or SLP Series ue pipe components. A DVP-TVHW or SLP-TVHW vertical Termination Cap must be used to terminate ue systems in a vertical position.
31 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 7.9 Flue Components and T erminations MODEL 350TRSI-AUF 350TRSILP-AUF FLUE TERMINA TION APPROV ALS DVP-TRAP2 HORI.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 32 Figure 7.10 T wo Elbows V 1 H 1 Maximum V 2 V 1 + V 2 Min. Elbow only Not allowed * * * 6 in. 152 mm 2 ft. 610 mm * * * 1 f t. 305 mm 4 ft. 1.22 m * * * 2 ft. 610 mm 6 ft.
33 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 7.1 1 T op V ent - V ertical T ermination - (continued) Three Elbows V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 34 Rear V ent - Horizontal T ermination Figure 7.13 No Elbow One 45º Elbow H 1 H 1 Minimum H 1 Maximum 6-1/2 in. (165 mm) 18 in. (457 mm) Do not use a 45º elbow in corner installations.
35 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.14 Figure 7.15 Three Elbows USE DVP SERIES COMPONENTS ONL Y USE DVP SERIES COMPONENTS ONL Y H 1 H 2 V 1 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 6 in.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 36 Rear V ent - V ertical T ermination One Elbow Figure 7.16 T wo Elbows Figure 7.17 V 1 H 1 IN ST AL LED HO RI ZO NT AL L Y H 1 H 2 V 1 USE DVP SERIES COMPONENTS ONL Y USE DVP SERIES COMPONENTS ONL Y V 1 Minimum H 1 Maximum 1 ft.
37 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 38 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
39 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 C. Install the Ceiling Firestop A ceiling restop MUST be used between oors and attics. • DVP pipe only - Frame an opening 10 in. x 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/oor (see Figure 8.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 40 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
41 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 42 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. N OT ICE : Onc e the sea l cap has be en remo ved it CAN NO T be reattached.
43 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 9.16 Proper Positioning and Securing of an Appliance NAILING TABS (BOTH SIDES) PILOT HOLES Figure 9.14 Non-combustible Board C. Installing the Non-combustible Board The fac tor y suppl ied non -co mbu sti ble boa rd must be used.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 44 Figure 9.17 Fixed Glass Assembly GLASS ASSEMBL Y LA TCHES (BOTH BOTTOM AND TOP) E. Covers Removal For Servicing Control Compartment Access Door • Lift the lower door up and out to access the gas controls.
45 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 1 0 Installing V ent Pipe ( D V P and SL P P ipe ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Not e: T he end of the pi pe sec tio ns with the la nced tabs w ill fac e toward th e applia nce.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 46 B. Assemble V ent Sections (SLP Pipe Only) T o attach the rst vent component to the starting collars of the appliance: • Lock the vent components into place by sliding the pipe section onto the collar .
47 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Di sa ss emb le V e nt S ect io ns • Rotate either section (see Figure 10.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 48 10 in. (254 mm) 12 in. (305 mm) INTERIOR WALL SHIELD G. Install Firestops For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the ue passes.
49 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 10.15 Ceiling Firestop (Ceiling Side) Figure 10.16 Attic Firestop CEILING CEILING FIRESTOP RAFTER NAILS (4 REQUIR.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 50 J. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.19) to determine the length of pipe to extend through the roof. • Slide the roof ashing over the pipe sections extending through the roof as shown in Figure 10.
51 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 CAULK K. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 52 1 1 Gas Informat ion A. Gas Pressure Requirements W ARNING! Risk of Explosion! An in-line regulator MUST be installed if the gas pressure exceeds 3.7 kPa. Failure to install a regulator could damage valve.
53 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Figure 1 1.1 The gas is introduced to the appliance on the left hand side. See Figure 1 1.1. After the gas pipe installation is complete, check carefully all ga s conn ect ions for lea ks wit h a comm erci all y-av aila ble , noncorrosive leak check solution.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 54 1 2 Elec tr ical Information Figure 12.1 IPI Wiring Diagram /RC300AU C. Optional Accessories Requirements • This appliance may be used with a wall switch, wall mounted thermostat and/or a remote control.
55 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 BLUE BROWN GREEN/ YELLOW Figure 12.2 D. Blower These heaters have a factory installed fan and electrical junction cord. These components are located behind the lower door .
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 56 Hearth & Home T echnologies disclaims any responsibility for , and the warranty will be voided by , the following actions: • Installation and use of any damaged system component.
57 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 5. Close the housing door . See Figure 12.7. 4. Pla ce rem ote co ntr ol in sid e h ous ing .
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 58 Figure 12.7 Mounting Remote Control Housing AUX300CE Module Installation • In ser t t he 4 h ol e h ar nes s f ro m t he AUX 30 0CE mod ul e i nt o the 4 pin pl ug on th e c ont rol mo du le.
59 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 FIREPLACE ST A TUS THERMOST A T THERMOST A T DESIRED TEMP SETTING FLAME HEIGHT F AN SPEED ADJUST ABLE AUXILIARY ADJUST A.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 60 About ON Mode • All functions can be accessed when the remote control is in the ON mode. • Only active functions will be displayed when the remote control is in the ON mode.
61 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Adjusting Thermostat • Press the MENU button to activate the menu. • Using the UP and DOWN arrows highlight the THERMO icon and press SELECT . • Use the UP and DOWN arrows to turn the THERMO ON or OFF , then press SELECT (the SET TEMP will start blinking).
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 62 Frequently Asked Questions/T roubleshooting Symptom Possible Cause Corrective Action Remote control will not transmit Batteries V erify batteries are functional and installed correctly .
63 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 1 3 Finis hing A. Mantel and W all Projections W AR NI NG! R isk o f Fir e! C om ply w ith a ll m in imu m cl ea r - an ces as sp ec ie d.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 64 A. Remove Fixed Glass Assembly See Section 9.E. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the rebox.
65 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 E. Log Placement Instructions Log Assembly: LOGS-350CE-D 1 2 3 4 5 6 Carefully remove the logs from the packaging. CAUTION: Logs are fragile! LOG #1 (SRV327-701): Place log #1 at the rear of the unit, with the left edge behind the tab on the pilot bracket.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 66 LOG #3 (SRV705-703): Rest log #3 against the right front grate corner and place its slot over the right burner tab. LOG #4 (SR V530-716): Place the left end of log #4 in the groove on log #2 and the right end on log #1 as shown.
67 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 6 6 LOG #6 (SR V540-704): Place log #6 against the second and third grate tines. If sooting occurs, the logs might need to be repositioned slightly to avoid excessive ame impingement.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 68 1 5 T roublesho oting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
69 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 T roubleshooting (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot ame has been lit, ame rectication has not occurred.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 70 1 6 Reference Materials A. Appliance Dimension Diagram Di men si on s a re a ct ua l a pp li anc e di men si on s. Us e for r ef ere nc e onl y . F or fr am in g d im en sio ns a nd cl ea ran ce s ref er t o S ec ti on 5.
71 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 B. Maintenance T asks Inspect Maintenance T asks Doors 1. Inspect for scratches, dents or other damage and repair as necessary . 2. V erify no obstructions to airow . 3.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 72 C. V ent Components Diagrams Figure 16.3 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 .
73 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 C. V ent Components Diagrams ( continued ) Figure 16.4 DVP vent components DVP-TRAP2 DVP-TRAP2 Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 74 DVP-TRAPFL Flashing DVP-HRC-SS DVP-HRC-ZC-SS Horizontal T ermination Cap Fire Risk. • When using DVP-HRC-SS and DVP-HRC-ZC- SS termination caps on top vented fireplaces, a 6 inch (152 mm) minimum vert ical vent section is require d before installing first elbo w .
75 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 B. V ent Components Diagrams (continued) Figure 16.6 SLP Series V ent Components 8-3/4 in.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 76 SLP-TVHW V ertical T ermination Cap SLP90 SL-2DVP DVP-FBHT DVP-FBHT SLP-TRAP2 Horizontal T ermination Cap 15-1/8 in. (384 mm) Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
77 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 D. Service Parts Beginning M anufacturing Date: July 2010 Ending M anufacturing Date: ______ 350TRSI-AUF , 350TRSILP-AUF Log Set Assembly IMPORT ANT : THIS IS DA TED INFORMA TION.
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 78 Service Parts Beginning M anufacturing Date: July 2010 Ending M anufacturing Date: ______ 350TRSI-AUF , 350TRSILP-AUF #17 V alve Assembly IMPORT ANT : THIS IS DA TED INFORMA TION.
79 Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 Service Parts List 350TRSI-AUF , 350TRSILP-AUF IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • 350TRSI-AUF , 350TRSILP-AUF • 2089-980 Rev . o • 6/12 80 E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , please visit www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Heat & Glo LifeStyle 350TRSI-AUF è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Heat & Glo LifeStyle 350TRSI-AUF - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Heat & Glo LifeStyle 350TRSI-AUF imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Heat & Glo LifeStyle 350TRSI-AUF ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Heat & Glo LifeStyle 350TRSI-AUF, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Heat & Glo LifeStyle 350TRSI-AUF.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Heat & Glo LifeStyle 350TRSI-AUF. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Heat & Glo LifeStyle 350TRSI-AUF insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.