Manuale d’uso / di manutenzione del prodotto BTF-75 del fabbricante A.O. Smith
Vai alla pagina of 20
1 PRINTED IN U. S.A. 0901 P ART NO . 194643-000 Thank you for buying this energy efficient water heater from A.O. Smith W ater Products Company . We appreciate your confidence in our products. CAUTION TEXT PRINTED OR OUTLINED IN RED CONT AINS INFORMA TION RELA TIVE TO YOUR SAFETY .
2 ROUGH-IN-DIMENSIONS FOREWORD The design of model BTF-75 complies with the latest version of ANSI Z21.10.3/CSA 4.3 M98 as automatic storage or automatic circulating tank type water heaters.
3 GENERAL SAFETY INFORMA TION PRECAUTIONS DO NOT USE THIS APPLIANCE IF ANY P ART HAS BEEN UNDER W A TER. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water .
4 IF YOU EXPERIENCE AN OUT-OF-GAS SITUA TION, DO NOT TRY TO RELIGHT APPLIANCES YOURSELF . Ask your LP delivery person to relight pilots for you. Only trained LP professionals should conduct the required safety checks in accordance with industry standards.
5 The heater is design certified by the Canadian Standards for installation on combustible flooring in a closet having minimum clearances from combustible material of: 2" clearance from sides and rear , 6" from the front and 24" from the top.
6 CLOSED W A TER SYSTEM A closed system will exist if a back-flow preventer (check valve), pressure reducing valve, or other similar device is installed in the cold water line between the water heater and the street main (or well).
7 5 . The vent termination shall not be mounted directly above or within 3 feet horizontally from an oil tank vent or gas meter to avoid potential freeze-up from condensation. Plan the vent system layout so that proper clearances are maintained from plumbing and wiring.
8 PVC Materials should use ASTM D-2564 Grade Cement; CPVC Materials should use ASTM F-493 Grade Cement and ABS Materials should use ASTM D-2235 Grade Cement. NOTE: 1. For water heaters in locations with high ambient temperatures (above 100°F) and/or insufficient dilution air , it is recommended that CPVC or ABS pipe and fittings be used.
9 POWER VENT WIRING SCHEMA TIC - FIGURE 7 A. Remove two screws that secure side plate on control box and remove plate. B . Cut flexible power cord on inside of control box, as close to inside wall as possible. C . If flexible cord and strain relief are removed, then opening in box must be covered.
10 INST ALLA TION OF VENT SYSTEM, SIDEW ALL With the route of the venting system and selection of materials completed, as discussed in section of this manual titled PLANNING THE VENT SYSTEM, the throu.
11 • Rag - Cotton (Not Synthetic) • Primer and Cleaner • Solvent Cement - PVC for PVC Components and CPVC for CPVC Components • Containers - Metal or Glass to hold Primer and Cement.
12 G. Cleanup and joint movement Remove all excess cement from around the pipe and fitting with a dry cotton rag. This must be done while the cement is still soft. The joint should not be disturbed immediately after the cementing procedure, and sufficient time should be allowed for proper curing of the joint.
13 W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier ’s instructions.
14 PURGING Gas line purging is required with new piping or systems in which air has entered. CAUTION PURGING SHOULD BE PERFORMED BY PERSONS EXPERIENCED IN THIS TYPE OF GAS SERVICE. TO A VOID RISK OF FIRE OR EXPLOSION, PURGE DISCHARGE MUST NOT ENTER CONFINED AREAS OR SP ACES WHERE IGNITION CAN OCCUR.
15 HIGH TEMPERA TURE CUT-OFF SWITCH The thermostat has a built-in temperature cut-off switch (TCO), which will shut off gas to the burner in case of excessive water temperature. If the TCO functions the valve will flash 4 times and the valve must be replaced.
16 Should the main burner or burner air openings require cleaning, remove the burner and clean with a soft brush. Clean main burner orifice with a suitable soft material. CHECK FOR GOOD FLOW OF COMBUSTION AND VENTILA TING AIR TO THE UNIT . MAINT AIN A CLEAR OPEN AREA AROUND THE HEA TER A T ALL TIMES.
17 NOT ENOUGH OR NO HOT W A T ER VENT PIPE TOO HOT (ABOVE 170° F) YELLOW FLAME CONDENSA TION W ATER LEAKS LEAKING T&P V AL VE HOT W A TER ODORS OR COLOR (Refer to CA THODIC PROTECTION) PROBLEM PO.
18 OFF BRITE - DM 1 FLASH 2 FLASHES 3 FLASHES 4 FLASHES 5 FLASHES 6 FLASHES LED ST A TUS INDICA TES CHECK/REP AIR No power to system control. Normal Operation This indication shows whenever the system is powered, unless some abnormal event has occurred.
19 SV9560/SV9570 SMARTV AL VE ® W A TER HEA TER CONTROL TROUBLESHOOTING GUIDE ST ART l CHECK FOR PROPER VOL T AGE A T CONTROL HARNESS (SEE INSET A). VOL T AGE SHOULD BE 120V BETWEEN 120V COMMON AND 120V HOT . TURN ON GAS SUPPL Y PLUG HARNESS INTO SmartV alve ® CONTROL.
20 A. O. Smith Corporation, the warrantor , extends the following LIMITED W ARRANTY to the owner of this water heater. 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examin.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il A.O. Smith BTF-75 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del A.O. Smith BTF-75 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso A.O. Smith BTF-75 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul A.O. Smith BTF-75 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il A.O. Smith BTF-75, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del A.O. Smith BTF-75.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il A.O. Smith BTF-75. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo A.O. Smith BTF-75 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.