Manuale d’uso / di manutenzione del prodotto BFM 30 del fabbricante A.O. Smith
Vai alla pagina of 32
BFM 30 BFM 50 BFM 80 MODELS INST ALLA TION INSTRUCTIONS AND USERS MANUAL UNITED KINGDOM CLOSED COMBUSTION W A TER HEA TER.
2 INTRODUCTION Read the installation instructions before installing the water heater. Read the user-instructions before lighting the water heater. If these instructions are not followed carefully, this may lead to explosion and/or fire and can cause material damages and/or physical harm.
3 CONTENTS PAGE 1 . GENERAL 1.1 Water heater description .................................................................................................... ................. 5 1.2 Technical safety equipment ..........................................
4 Figure 1 1 ) TOP-BOX 9 ) VENTILATION FAN 2 ) AIR PROVING SWITCH 10 ) ANODE 3 ) TEMPERATURE REGULATOR 1 1) FLUE TUBES ON/OFF SWITCH 12 ) FLUE BAFFLE RESET-KNOB 13 ) DIAPHRAGM 4 ) BURNER CONTROLLER 14.
5 1. GENERAL 1.1 Description of the appliance Construction and fitting out of the storage appliance comply with the European Standard for gas fired hot water storage appliances for sanitary use (EN89). The appliance thereby satisfies the requirements of the European Directive for Gas Appliances, and is therefore entitled to bear the CE mark.
6 1.2 Technical safety equipment 1.2.1 Gas control The water heaters are equipped with a gas control valve which regulates the flow of gas to the burner. The combination gas control is equipped with a safety valve, gas control valve, pilot safety valve and burner control (on a standard natural gas setting) 1.
7 Figure 3 - Differential pressure switch Figure 2 - Positioning ventilation.
8 1. 3 Technical description 1.3.1 Measurements See figure 4 All dimensions in mm, rounded up to the nearest 5 mm. Size BFM 30 BFM 50 BFM 80 A 1995 1995 2020 B 1795 1795 1820 C 600 600 600 D 520 520 5.
9 Figure 4 I MD- 0057 -R0.
10 Description Unit BFM 30 BFM 50 BFM 80 DATA NATURAL GAS G 20 Nominal gas inlet pressure mbar 20 20 20 Burner pressure mbar 12.5 12.5 12.5 Input k W 2 9 4 7 7 5 Output to water kW 2 7 4 2 6 8 Gas consumption* m3/h 3. 0 4 .7 7. 9 Diameter main injector m m 2.
11 I MD- 0065 2 . FOR THE INSTALLER If possible, use a trolley or fork-lift truck to move the water heater. Always move the water heater in an upright position.
12 I MD- 0066 -R0 Depending on the length and insulation of the water piping and the water demand frequency, it may be necessary to install a circulation system on the drain cock. The return pipe of the circulation piping can be fitted on the top of the drain cock after the sealing plug has been removed (see figure 6).
13 I MD- 0059 Depending on the water demand pattern (e.g., small amounts frequently), it may be necessary to circulate the water in the water heater to prevent temperature stratification. Therefore, we recommend that a circulation system is installed in the event of such demand patterns (see figure 8).
14 Flue configuration / horizonal discharge BFM-unit Measurement BFM 30 BFM 50 BFM 80 min. max. min. max. min. max. A 0 7000 0 7000 0 7000 B 0 7000 0 7000 0 7000 A +B < 7000 < 7000 < 7000 All measurements are in mm. The following applies for the horizontal pipe: slope of at least 5 mm per metre of pipe to the water heater.
15 I MD- 0061 I MD-00 62 Figure 10 and 11 - Roof discharge. All measurements are in mm. The following applies for the horizontal pipe: slope of at least 5 mm per metre of pipe to the water heater. A maximum of 2 bends (45° or 90°) may be used with Flue configurations roof discharge BFM-unit Measurement BFM 30 BFM 50 BFM 80 min.
16 2.1.6 Electrical connection All electrical connections must be carried out by a registered electrical contractor to the relevant regulations. The BFM must be connected to a supply voltage by means of a permanent electric connection and have a feeder cable not less than 3 x 1,0 mm².
17 Figure 12 - Electrical connection diagram BFM I MD 0055 R1.
18 Figure 13 - Connection diagram control-column. D) Transformer 230 E) Air proving switch F) EMC single phase filter G ) RESET knob H) Thermostat frost K) Thermostat regulation L ) Switch ON/OFF M ) .
19 2. 2 Turning the water heater on 2.2.1 Filling the water heater 1. Assemble the drain-off tap and check that it is closed. 2. Open the cold water tap to the water heater and open a l l taps on hot water outlet points to vent them. The heater is filled as soon as cold water pours out of all outlet points.
20 Figure 14 - Checking the gas pressures 2. 5 Checking the gas pressures The nominal load has been set at the correct value in the factory. A further check of the pressure should be carried out during the commissioning of the unit. A dangerous situation can occur if the following instructions are not followed carefully.
21 2. 6 Conversion to another gas Important: Install a gas valve suitable for the type of gas to be used. If the water heater has to function on a gas category (LP or natural gas) other than the gas set as standard (ex works), the water heater must be converted to the applicable gas category with the associated conversion kit(s).
22 2 . 7 Maintenance The water heater must be checked and cleaned regularly (at least once a year) by an accredited installer, so that proper operation is guaranteed. The bar burners, control and safety valves must also be checked. (see figure 17). 2.
23 2.10 Condensation If the water heater has been filled with cold water or if the hot water usage has been very high, normally condensation of the flue gasses will occur on the cold sides of the combustion chamber and the flue tubes. The water drops will fall on to the burner bed which can cause a hissing sound.
24 3 . FOR THE USER 3.1. Instructions for use Installation and commissioning of the water heater should only be undertaken by a registered installer. 3.1.2 Filling the water heater 1. Assemble the drain-off tap and ensure it is closed; 2. Open the cold water tap to the water heater and open a l l taps on hot water drain-off points to vent them.
25 No or insufficient hot water. Check whether the electricity is turned on. Check whether the gas supply is turned on. Does the ON/OFF switch light up? Does the RESET switch light up? Push RESET switch up to three times Is the water heater in operation? Consult your installer.
26 4. 2 Fault finding INSTALLER Check if ON/OFF switch is in position 1 ? Put ON/OFF switch in position 1 . Problem solved yes Is the water heater in operation? Problem solved yes Is the water heater .
27 4. 3 Detailed fault finding INSTALLER no Check voltage present at connection 1 . Reinstate voltage supply no Ensure connections correct, if yes replace FILTER Ensure connections correct, if yes rep.
28 Ensure connections correct, if yes replace MAXIMUM THERMOSTAT Check voltage present at GATE 12 MAXIMUM THERMOSTAT? Check voltage present at GATE 1 BURNER AUTOMATION S4560D 1150? Check voltage prese.
29 yes yes yes yes yes yes yes yes no no no no no no no Check voltage present at GATE 12 ECO Check voltage present at GATE 11 BURNER AUTOMATION Pressure H higher then 300 PA? Pressure L less then 0 PA.
30 Re-instate gas supply and reset water heater Water heater in in operation? Gas supply present? Problem solved IONISATION PROBLEMS. Carry out 3 RESET cycles to make sure the pilot is provided with gas. Check gasconnections towards the pilot burner. Carry out one more RESET cycle.
31 5 . WARRANTY The following conditions form the guarantee agreement between A.O. Smith Water Products Company (the warrantor) and the owner of the water heater.
32 0305 664 R0.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il A.O. Smith BFM 30 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del A.O. Smith BFM 30 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso A.O. Smith BFM 30 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul A.O. Smith BFM 30 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il A.O. Smith BFM 30, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del A.O. Smith BFM 30.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il A.O. Smith BFM 30. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo A.O. Smith BFM 30 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.