Manuale d’uso / di manutenzione del prodotto AD2078 del fabbricante American Dynamics
Vai alla pagina of 36
Model AD2078 System Keyboard Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics AD2078 System Keyboard. AD2078 Series keyboards are used with American Dynamics Matrix Switching Systems for full system control and for programming and setup functions.
The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMA TIC ELECTRONICS CORPORA TION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMA TIC. The software/firmware is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
.
CONTENTS Page DESCRIPTION................................................................................................. 1 FEA TURES ....................................................................................................... 1 INST ALLA TION .
.
DESCRIPTION The AD2078 Series keyboard is used with American Dynamics Matrix Switching Systems for full system control and for programming and setup functions.
CONNECTIONS T o connect the AD2078 keyboard to a Matrix Switching System, refer to the following text and to the T ypical System Connections illustrations at the end of this manual. Matrix Switching System Connection An 8-pin, modular RJ-45 port, located on the underside of the keyboard, is used for all AD2078 connections, both RS-232 and power .
AD2078 SETUP SETUP Communication Port T ype The keyboard interface can be set for either RS-232, RS-422, or RS-485 communications, depending on the type used by the system controller . The communications type is set by a DIP switch, labeled "COMMUNICA TIONS SWITCH", located on the bottom of the keyboard.
KEYBOARD LA YOUT AD2078 KEYBOARD LA YOUT (Refer to the following pages for definitions of keyboard display and control functions.) ST A TUS SECTION ST A TUS DISPLA Y - Shows status information from th.
OPERA TION The following information is for general use of the AD2078 keyboard. For use with a specific switching system, refer to that system's Operating Instructions manual. Keyboard control of switching system functions is, generally , "monitor oriented".
MONITOR Section Contr ols ARM The ARM button is used to arm the "called" monitor . When a monitor is armed, the camera video associated with an alarm for that monitor is displayed when that alarm is activated. This action (and the OFF button action) af fects only the monitor currently under control of the keyboard (the called monitor).
AUX/LENS Section Controls AUXILIAR Y The ON and OFF buttons in the AUXILIAR Y section control the operation of momentary and latched auxiliaries. The action of either momentary or latching auxiliaries depends on the options installed on the 1640/1680 Series Receiver at the site being controlled.
.
APPENDIX.
.
BUIL T -IN TEST The AD2078 keyboard has a built-in test capability to help identify possible faults with the keyboard's software or hardware. The built-in test has the following test procedures: 1. Speaker T est 2. LED Lamp T est 3. LED Brightness T est 4.
AD2078 BUIL T -IN TEST CAMERA Display During the movement checks, the CAMERA display also shows two message codes. These codes are displayed in the six LED positions of the CAMERA display , as shown below . CAMERA Display: The three left-most digits display a numeric value, from 0 to 255.
TYPICAL SYSTEM CONNECTIONS.
.
TYPICAL SYSTEM CONNECTIONS AD2078 TO AD1650B C-2 AD2078 * Items supplied with AD2078 keyboard **Items supplied with AD1650B system 1 5 4 6 3 2 7 8 5 4 6 3 2 7 1 8 J1 J2 Keyboard System JJ0007.
TYPICAL SYSTEM CONNECTIONS AD2078 TO AD1650B C-3 AD2078 * Items supplied with AD2078 keyboard **Items supplied with AD1650B system HP0047 TERMINAL BLOCK ** 1 2 3 45 6 7 8 JJ0007 Cable * JJ000.
TYPICAL SYSTEM CONNECTIONS AD2078 to AD1996 CPU AD2078 AD1996 1 2 34 56 7 89 10 PROG MON DATA LINE PORTS 12 120V 60HZ 1 5 4 6 3 2 7 8 5 4 6 3 2 7 1 8 J1 J2 Keyboard System JJ0007 Cable * Connection sh.
TYPICAL SYSTEM CONNECTIONS AD2078 TO AD1996 CPU 1 2 34 56 7 89 10 PROG MON DATA LINE PORTS 12 120V 60HZ AD1996 Connection shown where distances between keyboard and AD1996 are over seven feet C-5 AD20.
TYPICAL SYSTEM CONNECTIONS AD2078 to AD2150/2350 AD2078 Keyboard System JJ0007 Cable ** Connection shown where distances between keyboard and AD2150/2350 are less than seven feet AD2150/2350 C-6 * Ite.
TYPICAL SYSTEM CONNECTIONS AD2078 TO AD2150/2350 AD2150/2350 Connection shown where distances between keyboard and AD2150/2350 are over seven feet C-7 AD2078 5 4 6 3 2 7 1 8 J1 J2 HP0047 TERMINAL BLOC.
TYPICAL SYSTEM CONNECTIONS AD2078 with AD1981 Port Expander AD1996 12 3 4 5 678 9 1 0 PROG MON DATA LINE PORTS 12 120V 60HZ C-8 To CPU KBD d KBD c KBD b KBD a 5 4 6 3 2 7 1 8 J1 J2 HP0082 AD2078 5 4 6.
TYPICAL SYSTEM CONNECTIONS Built-in Test Connection Self-Test Jumper Connection C-9 AD2078 5 4 6 3 2 7 1 8 J1 J2 Keyboard JJ0007 Cable HP0082 TERMINAL BLOCK XMIT RCD Wall Transformer.
INDEX.
.
AUX/LENS Section Buttons Keyboard Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation (see also OPERA TION - AUX/LENS) . . . . 7 Built-In T est . . . . . . . . . . . . . . . . . . . . . . . . . . . . APPENDIX Joystick Calibration/Speed Check .
.
PROBLEM CHECKLIST ✘ No power to keyboard ✓ Check wall transformer and connections ✓ Check modular cable connections to keyboard and to T erminal Block J1/Keyboard jack ✘ Keyboard has power but.
.
Declaration of Conformity Manufact urer: Sensormatic CCTV Systems Division Manufact urer’s Addres s: Sensormatic CCTV Systems Division Sensormatic CCTV Systems Division 1 Blue Hill Plaza 600 Bradley.
An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River , New Y ork, 10965 Business: (914) 624-7600 T echnical Support Center: 1-800-442-2225 F AX: (914) 624-7685 OP2078F Printed in U.S.A. November , 1996 SPECIFICA TIONS Desktop Models Input: AD2078: 9 V AC, 50/60 Hz.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il American Dynamics AD2078 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del American Dynamics AD2078 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso American Dynamics AD2078 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul American Dynamics AD2078 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il American Dynamics AD2078, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del American Dynamics AD2078.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il American Dynamics AD2078. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo American Dynamics AD2078 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.