T ABLE OF CONTENTS I) Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 II) Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 III) Inst allation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 2 – Thank you for purchasing this water heater . Properly inst alled and maint ained, it will provide years of trouble free service. This manual gives instructions for the proper inst al- lation, safe operation and maintenance of this water heater .
– 3 – R elief V alv e R equir ements For protection against excessive pressure and/or tempera- tures, an ASME approved T emperature and Pressure (T&P) Relief V alve must be inst alled in the opening provided and labeled near the hot water outlet.
– 4 – 610mm (24 in.) MIN. FOR SER VICING 457mm (18 in.) MIN. FLUE SEE T ABLE T OP SEE T ABLE FLUE SIZES SEE T ABLE NON-COMBUSTIBLE FLOOR COMBUSTIBLE CEILING DRAFT REGULA T OR FLUE SEE T ABLE Figur.
– 5 – Figure 2 INST ALLA TION DIMENSIONS (CENTER FLUE MODELS) J W F3 07 J W F5 07 J W F6 57 J W F307 V mm 50 8 559 6 60 50 8 in. 20 2 2 26 20 mm 22 9 229 2 54 22 9 in. 9 9 10 9 mm 45 7 457 5 24 45 7 in. 18 18 20 5/8 18 mm 69 9 660 7 75 69 9 in. 27 1/2 26 30 1/2 27 1/2 mm 128 6 14 86 16 61 12 86 in.
– 6 – Air R equir ements An adequate supply of combustion and ventilation air is required to: • Ensure proper combustion. • Reduce risk of property damage, severe bodily injury or death from possible flue gas leakage and carbon monoxide emissions.
– 7 – appliances in the enclosure, freely communicating with inte- rior areas that have in turn adequate infiltration from the out- side. It shall also have a combustion air supply opening so that the tot al air received through the opening will be at least as much as would be admitted by openings having a tot al free area of 4.
– 8 – Chimney Be sure that the chimney is suf ficiently high and large enough to meet the specifications of the burner unit inst alled. Check that there is suf ficient draf t for the proper burning of oil. At least -0.015 in. (-0.381mm) water column of over-fire draf t is recommended.
– 9 – Burning Equipment (NFP A 31)” (as applicable), local codes and the manufacturer ’ s instructions. The burner should be inst alled only by a qualified Oil-Burner T echnician.
– 10 – up of lime in the T&P valve, there are two recommendations: 1. Inst all a pressure relief (only) valve in the cold water supply line. Make sure that the discharge of this valve is directed to a drain and it is protected from freezing. or: 2.
– 11 – LINE VOL T AGE THERMOST A T OR AQUAST A T® CONTROL OIL V AL VE BURNER MOT OR IGNIT OR CAD CELL LIMIT TO REMOTE ALARM CIRCUIT JUMPER ENVIRACOM™ TERMINAL L1 LIMIT L2 V AL VE CAD CELL ALARM.
– 12 – St artup MAKE SURE THA T THE HEA TER IS FULL OF W A TER. See “Filling the W ater Heater” section. DO NOT A TTEMPT T O ST ART BURNER IF ANY OF THE FOLLOWING CONDITIONS EXIST : 1. Excess oil has accumulated. 2. The unit is full of vapours.
– 13 – Wa ter T emper a tur e Re gula tion Once inst alled, the operation will be completely automatic. The thermost at (aquast at) on the water heater is adjust able and will maint ain water at the desired temperature.
W ARNING! The temperature and pressure relief valve must be manually operated at least once a year . Caution should be t aken to ensure that: 1. No one is in front of or around the outlet of the temper- ature and pressure relief valve discharge line. 2.
– 15 – • Black water can be an indication of organic cont ami- nates in the water supply . This can be problematic in areas where the water is obt ained from surface or cont- aminated sources. Organic p articles can develop bacte- rial growth, causing potential health hazards.
– 16 – 1. Shut of f the oil supply at the t ank. 2. Shut of f the cold water supply to the heater . 3. T urn "OFF" the electrical supply to the water heater . 4. Open an up st airs hot water faucet (to relieve any pres- sure). When freezing temperatures are expected: 1.
– 17 – W A TER HEA TER 8in T O 12in MAX. HOT OUTLET EXP ANSION T ANK (OPTIONAL) MIXING V AL VE COLD INLET CHECK V AL VE (IF USED REQUIRES EXP ANSION T ANK) COLD SUPPL Y HOSE BIB (OPTIONAL) FLOW CO.
– 18 – T able 1 LISTING OF OIL BURNERS. Mode l MFGR Burn er N ozz le & P u mp P re s s . Bl ast tube No t e s BE CKE T T AFG GSW - J3 037 0.75 GPH U . S. ON LY BE CKE T T AFG GSW - J3 036 0.75 GPH MA SS . ONL Y C ARLI N E Z 19 729 7AJW 31 7 0.
– 19 – Mode l MFGR Burn er N ozz le & P u mp P re s s . Bl ast tube No t e s AE RO FA FC- 2X 0.75 GPH AE RO S V - 2X 0.75 GPH AE RO FA FC- 2X 0.75 x 8 0A 5 15/16 " AE RO S V - 2X 0.75 x 8 0A 5 15/16 " BE CKE T T AFG GSW - J5 006 0.75 GPH C ANADA BE CKE T T AFG GSW - J5 032 0.
See Rating Label Serial Number prefix for W arranty Code. Reduced warranty period applies to Newfoundland. W arranty Code: P R S T U V W Y S tandard W arranty Y ears: 3 5 6 7 8 9 10 12 Reduced W arran.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GSW JW317 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GSW JW317 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GSW JW317 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GSW JW317 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GSW JW317, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GSW JW317.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GSW JW317. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GSW JW317 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.