Roof Exhaust Fan Inst allation & Operation Owner ’ s Manual PNEG-524 Date: 04-11-07 PNEG-524.
2 PNEG-524 Roof Exhaust Fan Check List 1. All wire connections 2. Tip clearance on blade 3. Fan blade torqued to torque specs 4. Grill guard in place and tight 5. Motor rotation correct 6. Running amperage 7. Vibration 8. All fasteners tight 9. Indi cator lig ht 10.
PNEG-524 Roof Exhaust Fan 3 T able of Content s Contents Chapter 1 Safety .................... ................ ................ ................ ................ ................ ........ ............ ......... 4 Roof Damage Warning and Discl aimer .
4 PNEG-524 Roof Exhaust Fan 1. SAFETY Roof Damage W arning and Disclaimer Roof Exhauster Fan Ope ration Thank you for cho osing a GSI product. It is designed to give excellent performance and service for many years. This manual describes the operation of the GSI Roof Exhaust Fan.
PNEG-524 Roof Exhaust Fan 5 2 . S A F E T Y A L E R T D E C A L S The GSI Group, Inc. recommends contactin g your local power company, and having a representative survey your installatio n so the wiring is compatible with their system, and adequate power is supplied to your u nit.
6 PNEG-524 Roof Exhaust Fan 3. PRE INST ALLATION 18" & 24" Roof Fan Package Figure 3A An 18" Roof Exhaust Fan Your model package should contain items shown in above c hart . Note: Before starting the assembly and installation of the roof exha ust fan, check to see that all items called out on the pac king list have been received.
PNEG-524 Roof Exhaust Fan 7 4 . S P E C I F I C A T I O N S Fan Model Specifications for Roof Fans All single phase motors and the .5 HP exp losion proof three phase motor are supplied with automatic overload protection. The remaining th r ee phase motors do not have internal motor protection.
8 PNEG-524 Roof Exhaust Fan 5. INST ALLATION Standard electrical safety practices and codes should be used when working with a fan. Refer to the National Electric Code Standard Ha ndbook by the National Fire Protection Association. A qualified electrician should ma ke all wiring installations.
PNEG-524 Roof Exhaust Fan 9 5. INST ALLATION 18" Roof Fan Mounting The roof fan can be installe d in the roof sheet before assembling the roof, or a fter the roof is assembled. Locate roof fan so that inne r roof structure does not interfere with installation.
10 PNEG-524 Roof Exhaust Fan 5. INST ALLATION 24" Roof Fan Mounting and Assembly of Fan, Adaptor and Rain Hood The roof fans, adaptor and rain hood can be installed in the b in roof sheet before assembling the roof or after the roof is assembled.
PNEG-524 Roof Exhaust Fan 1 1 5. INST ALLATION 3. Drill two corner holes and bolt template in place. 4. Drill the remaining 11/32" mo unting holes identified on the template. Figure 5E The Rainhood Preassembly . 5. Mark a cutting line 3/4" inside the template .
12 PNEG-524 Roof Exhaust Fan 5. INST ALLATION 9. Form a lip up around the inside of the adaptor opening by peening up the edge of the roof sheet extending past the inn er edge of the roof adaptor. 10. Loosely bolt the rainhood to p plate, rainhood right side and rainhood left side together.
PNEG-524 Roof Exhaust Fan 13 5. INST ALLATION 24" Roof Exhauster Reinforcement Kit Figure 5J 1. Refer Page 11 for the 24" roof adapto r template and mounting, and the 30° Roof Manual PNEG-030 for the roof channel asse mbly. 2. Install the roof support channels in the ribs of the upper panel where the exhaust er is to be mounted.
1 4 P N E G -5 2 4 R o of E xh aust Fan NOTES.
PNEG-524 Roof Exhaust Fan 15 6 . P A R T S L I S T 18" Roof Exhauster Part s Figure 6A 18" Roof Exhauster Pa rts Breakdown. 18" Roof Exhauster Part s Ref # Part # Description Qty 1 F-94.
16 PNEG-524 Roof Exhaust Fan 6. PART S LIST 24" Roof Exhauster Part s Figure 6B.
PNEG-524 Roof Exhaust Fan 17 6. PART S LIST 24" Roof Exhauster Part s Ref # Part # Description Qty 1 MIS-6664 Adaptor top plate 1 2 MIS-6666 Exhauster adaptor left panel 1 3 MIS-6665 Exhauster adaptor rig ht panel 1 4 MIS-6686 2 H.
18 PNEG-524 Roof Exhaust Fan 7. ELECTRICAL INST ALLATION Electrical Inst allation of the Fan The electrical installation must be performe d by a certified electrician in accordance with the appropriate national and local electrical codes. ANY VIOLA TION OF ELECTR ICAL WIRING CODES COULD JEOP ARDIZE THE AIRSTREAM W ARR ANTY .
PNEG-524 Roof Exhaust Fan 19 7. ELECTRICAL INST ALLATION Fan Disconnect A disconnect for the fan needs to be siz ed to handle the recommended fusetron size. Example: For a 24" fan the first chart on Page 17 would be used, and the fusetron size is 30 AMP.
20 PNEG-524 Roof Exhaust Fan 7. ELECTRICAL INST ALLATION Three Phase System With the power OFF at the fan disconnect, exch ange the location of the current carrying conductors at terminal L1 and L3 (Se e Figure 7A) of the magnetic controls. The unit will then need to be rechecked for proper ro tation.
PNEG-524 Roof Exhaust Fan 21 8 . O P E R A T I N G I N S T R U C T I O N S Before St arting Fan When starting the fan for the first time, check the following: 1. With the power OFF, rotate the fan blade to make sure it revolves easily, and doe s not rub on the venturi or fan tube.
22 PNEG-524 Roof Exhaust Fan 8. OPERATING INSTRUCTIONS If the fan just hums when turned ON, c heck the following: 1. Check to make sure that all leads of your power source ha ve voltage present. If fan unit is not receiving power on all leads, check fo r a blown fuse, broken wire or loose connection.
PNEG-524 Roof Exhaust Fan 23 9 . W A R R A N T Y Warranty THE GSI GROUP, INC. (GSI) WARRANTS ALL PRODUCTS WHICH IT MANUFACTU RES TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USAGE AND CONDITIONS FOR A PERIOD OF 12 MONTHS AFTER RETAIL SALE TO THE ORIGINAL END USER.
T his equipment shall be in stalled in a ccor dance with the cur r ent installation codes and applica ble re gulations which should be ca r efully follow ed in all cases. Authorities ha v ing jurisdiction should be consulted before inst allations are made.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GSI Outdoors PNEG-524 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GSI Outdoors PNEG-524 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GSI Outdoors PNEG-524 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GSI Outdoors PNEG-524 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GSI Outdoors PNEG-524, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GSI Outdoors PNEG-524.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GSI Outdoors PNEG-524. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GSI Outdoors PNEG-524 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.