AD-115ES II Installation Manual For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 T elephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry .
Retain This Manual In A Safe Place For Futur e Refer ence American Dryer Corporation products embody advanced concepts in engineering, design, and safety . If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation.
W ARNING UNDER NO CIRCUMST ANCES should the dryer door switch, lint door switch, or the heat safety circuit ever be disabled. IMPOR T ANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE G.
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer .
Table of Contents SECTION I IMPOR T ANT INFORMA TION ............................................................................... 3 A. Receiving and Handling ..........................................................................................
SECTION VI ROUTINE MAINTENANCE .................................................................................. 4 5 A. Cleaning .........................................................................................................................
3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage.
4 B. SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
5 7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust ductwork, and inside the dryer . The frequency of inspection and cleaning can best be determined from experience at each location. W ARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard.
6 SECTION II SPECIFICA TIONS/COMPONENT IDENTIFICA TION A. SPECIFICA TIONS * Refer to the Electrical Service Specification chart on page 25 for detailed electrical information. ** Refer to the Electrical Service Specification chart on page 26 (60 Kw oven), page 27 (72 Kw oven).
7 NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. Specifications ADG-1 15ES II (Gas) ADE-1 15ES II (Electric) ADS-1 15ES II (S team).
8 B. COMPONENT IDENTIFICA TION 1. Dryer Front V iew Illus. No. Description 1 Microprocessor Control and Keyboard (touch pad) Panel Assembly (controls) 2 Control (top access) Door Assembly 3 Main Door .
9 2. Dryer Rear V iew Illus. No. Description 1 Basket (tumbler) Drive Motor Assembly 2 Blower Motor Mount Assembly 3 Impellor (fan/blower) Assembly 4 Idler Bearing Mount Assembly 5 Basket (tumbler) Be.
10 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.
11 CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up. IMPOR T ANT: Dryer must be installed in a location/environment, which the ambient temperature remains between 40º F (4.
12 2. The V -belts are disconnected from the basket drive motor for shipping. Reconnect V -belts before starting the dryer . a . T o reconnect V -belts 1) Remove hardware holding back (belt) guard and remove guard from dryer .
13 4. Exhaust T ransition Piece a . Inside the basket (tumbler) of this dryer is an exhaust transition piece that must be installed on the outlet of the exhaust before any further venting is connected: 1) Remove the exhaust transition piece from the basket (tumbler) and place it on the exhaust outlet.
14 C. DR YER ENCLOSURE REQUIREMENTS It is recommended that the rear of the dryer be positioned approximately 3 feet (0.91 meters) from the nearest obstruction (i.e., wall) for ease of installation, maintenance, and service. Bulkheads and partitions should be made of noncombustible materials.
15 IMPOR T ANT : Make-up air must be provided from a source free of dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components. NOTE: Component failure due to dry cleaning solvent fumes will VOID THE W ARRANTY .
16 E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back p.
17 a . Outside Ductwork Protection 1) T o protect the outside end of the horizontal ductwork from the weather , a 90° elbow bent downward should be installed where the exhaust exits the building.
18 b. V ertical V enting When possible, it is suggested to provide a separate exhaust duct for each dryer . The exhaust duct should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible.
19 IMPOR T ANT : For extended ductwork runs, the cross section area of the duct can only be increased to an extent. When the ductwork approaches the maximum limits as noted in this manual, a professional heating, venting, and air conditioning (HV AC) firm should be consulted for proper venting information.
20 The main duct may be any shape or cross-sectional area, so long as the minimum cross section area is provided. The illustration on page 21 shows the minimum cross section area for multiple dryer round or square venting. These figures must be increased 10 square inches (64.
21.
22 c . V ertical V enting If it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may be channeled into a “common main duct.” The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of airflow and should be spaced at least 46-1/8” (1 17.
23 NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around).
24 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes.
25 2. Electrical Service Specifications *A WG Stranded W ire T ype...size wire as per National Electrical Code or local codes. (Motor lead wire is recommended.) ** 3-wire available. IMPOR T ANT : The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel behind top/access control door .
26 IMPOR T ANT : The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel behind top/access control door . In the case of 208 V AC or 240 V AC, the supply voltage must match the electric service specifications of the data label exactly .
27 IMPOR T ANT : The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel behind top/access control door . In the case of 208 V AC or 240 V AC, the supply voltage must match the electric service specifications of the data label exactly .
28 3. Electrical Connections NOTE: A wiring diagram is included with each dryer and is affixed to the rear upper right guard panel of the dryer . The only electrical input connections to the dryer are the 3-phase (3ø) power leads (L1, L2, and L3), GROUND, and in the case of 4 wire service, the neutral.
29 4. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO.
30 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
31 2. T echnical Gas Data a . Gas Specifications * Measured at outlet side of gas valve pressure tap when gas valve is on . b. Gas Connections: Inlet connection ................... 1 ” N.P .T . Inlet supply size ................... 1” N.P .T . (minimum) Btu/hr input (per dryer) .
32 3. Piping and Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.
33 NOTE: The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.
34 H. STEAM INFORMA TION It is your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that the installation is adequate and conforms to local and state regulations or codes.
35 a . The pressure of the condensate in the steam supply will cause water hammer and subsequent heat exchanger (steam coil) failure. The steam supply connection into the main supply line must be made within a minimum 12-inch (30.48 cm) riser . This will prevent any condensate from draining towards the dryer .
36 4. S team Damper Air System Connections The ADS-1 15ES is manufactured with a pneumatic (piston) damper system, which requires an external supply of compressed air . The air connection is made to the steam damper solenoid valve, which is located at the rear inner top area of the dryer just above the electric service relay box.
37 6. S team Damper Air Piston (Air Control) Operation Adjustment Although the damper operation was tested and adjusted prior to shipping at 80 PSI (5.51 bar), steam damper operation must be checked before the dryer is put into operation. Refer to page 36 for instructions to check system damper system operation.
38 I. PREP ARA TION FOR OPERA TION AND ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ W ARNING ,” and “ DIRECTION ” labels attached to the dryer .
39 J. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory . However , a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
40 2) The dryer is equipped with a Direct Spark Ignition (DSI) system, which has internal diagnostics. If ignition is not established after the first attempt, the heat circuit DSI module will “LOCKOUT” until it is manually reset. T o reset the DSI system, open and close main door and restart dryer (press the “ENTER/ST AR T” key).
41 b. Dual T imer Dryers 1) Spin and dwell (stop) times are adjustable at the reversing timer . BASKET (TUMBLER) COA TING The basket (tumbler) is treated with a protective coating.
42 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency , or gas supplier .
43 SECTION V WARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass.
44 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c . Date of dryer installation. d. Date of part failure. e . Specify whether the part(s) being returned is for a replacement, a credit, or a refund.
45 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location.
46 STEAM DRYERS Clean the steam coil fins. W e suggest using compressed air and a vacuum cleaner with brush attachment. W ARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straighten by using a fin comb, which is available from local air conditioning supply houses.
47 B. ADJUSTMENTS 7 DA YS AFTER INST ALLA TION AND EVER Y 6 MONTHS THEREAFTER Inspect bolts, nuts, screws (bearing setscrews), grounding connections, and nonpermanent gas connections (unions, shutoff valves, and orifices). Motor and drive belts should be examined.
48 SECTION VII TROUBLESHOOTING IMPOR T ANT : YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y OR THE STEAM SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO A.
49 C. Drive motor (r eversing) operates in one (1) direction only ...stops and restarts in same direction... 1. Failed drive motor contactor (relay). 2. Failed arc suppressor (A.S.) board. 3. Failed microprocessor controller (computer). D . Drive motor operates okay for a few minutes and then stops and will not restart.
50 H. Both drive motor and blower motor run a few minutes and then stop...microprocessor controller (computer) display continues to read time or percent of extraction and ALL indicator dots are off... 1. Fault in main door switch circuit... a . Failed main door switch.
51 2. Failed microprocessor controller (computer). L . Microprocessor controller (computer) will only accept certain keyboard (touch pad) entries... 1. Failed keyboard (touch pad) label assembly . 2. Failed microprocessor controller (computer). M . Microprocessor controller (computer) locks up and light emitting diode (L.
52 P . No heat (for Gas Models ONL Y)...ignitor sparks, burner goes on and off right away ... 1. Direct Spark Ignition (DSI) ignitor or flame-probe is out of adjustment...reposition closer to the flame area. 2. Sail switch is fluttering... a . Lint screen is dirty .
53 S. Dryer operates but is taking too long to dry ... 1. Exhaust ductwork run too long or is undersized...back pressure must be no less than 0 and cannot exceed 0.3 inches (0.74 mb) water column (W .C.). 2. Restriction in exhaust ductwork... a . Customer furnished exhaust back draft damper is sticking partially closed.
54 U . Dryer is making scraping noise at basket (tumbler) area... 1. Check for object caught in basket (tumbler) or wrapper area. 2. Basket (tumbler) is out of proper alignment... a . Check both vertical and lateral alignment. b. Check gap between front panel and basket (tumbler).
55 When contacting American Dryer Corporation , certain information is required to insure proper service/parts information from ADC . This information is on the data label located on the left side panel behind top/access control door . When contacting ADC , please have the model number and serial number available.
56 THE DA T A LABEL 1. MODEL NUMBER The model number is an ADC number , which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer .
57 SECTION IX REVERSING TIMER SPIN/DWELL ADJUSTMENTS Dual timer models with “reversing option” have an electric reversing timer in the electric service box, which is located in the upper rear area of the dryer .
58 SECTION X PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer . b. Start the drying cycle.
59 e . Open main door . The dryer must stop and ALL indicator lights on the back side of the microprocessor controller (computer) board must go out. (Refer to the illustration on the previous page.) f . T ry to restart the dryer with the main door open.
60 3. For Direct Spark Ignition (DSI) System Models Manufactured W ith ADC M odule Part No. 882627 a. Upon completing installation of the replacement DSI module, reestablish power to the dryer . b. Starting the drying cycle. c . The ignition DSI module’ s light emitting diode (L.
61 SECTION XI BURNER AND BASKET (TUMBLER)/LINT CHAMBER MANUAL RESET HI-LIMIT INSTRUCTIONS I M P O R T A N T MANUAL RESET HI-LIMIT INSTRUCTIONS FOR TIMER OR PHASE 5 WITHOUT HEA T F AUL T (GAS MODELS ONL Y) This dryer was manufactured with a burner and basket (tumbler)/lint chamber* manual reset hi-limit thermostat.
62 I M P O R T A N T MANUAL RESET HI-LIMIT INSTRUCTIONS FOR TIMER OR PHASE 5 WITHOUT HEA T F AUL T (ELECTRIC OR STEAM MODELS ONL Y) This dryer was manufactured with a basket (tumbler)/lint chamber* manual reset hi-limit thermostat.
ADC 113155 1 - 07/27/00-25 2- 01/02/01-25 3* 03/27/01-25 4- 04/26/01-25 5* 07/17/01-25 6 * 11/28/01-25 7 - 03/11/02-25 8 - 09/16/02-25 9 * 02/28/03-25.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il American Dryer Corp. AD-115ES II è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del American Dryer Corp. AD-115ES II - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso American Dryer Corp. AD-115ES II imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul American Dryer Corp. AD-115ES II ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il American Dryer Corp. AD-115ES II, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del American Dryer Corp. AD-115ES II.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il American Dryer Corp. AD-115ES II. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo American Dryer Corp. AD-115ES II insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.