1 104 Form # AM-324-03 American Met al W are ® Hot W ater Boiler Inst allation, Operation & Service Manual For Models 815, 830, 850 Gas Electric S team S pecial Features After completing inst allation and set-up, the equipment owner should keep this manual for future reference.
Page 1 American Met al W are Hot W ater Boiler Electric Models 815, 830, 850 Equipped with Option 46 Automatic Refill Option 39 Low W ater Cut-Off System General Description This unit is a high temperature hot water boiler .
American Met al W are Hot W ater Boiler Page 2 TO CHECK REFILL RA TE, allow water to fill to stop/full level automatically; then turn of f master switch. Draw off 1 gallon of water from faucet. Turn master switch back on and time how long it takes for the water level to come up to stop/full mark again.
Page 3 American Met al W are Hot W ater Boiler.
American Met al W are Hot W ater Boiler Page 4 Thermost at Factory set so that knob on BREW setting holds unit at brewing temperature toward HIGH end of brew zone on thermometer dial. Then, if turned back to HOLD position, thermost at should cycle on and off and hold at LOW 'end of BREW zone on thermometer .
Page 5 American Met al W are Hot W ater Boiler Service Instructions PROBLEM: THERMOST A T DIAL TURNED T O BREW AND W A TER IN COMP ARTMENT REMAINS COLD POSSIBLE CAUSE 1. 2. PROBLEM: W A TER BOILS CONTINUOUSL Y WITH THERMOST A T DIAL ON POSITION BREW OR HOLD.
American Met al W are Hot W ater Boiler Page 6 Dual Level Control Auto Refill And Low W ater Cutoff System I) II) Dual Level Control: What it does: Description and Operation of Dual Level Control System: A. B. C. A. AUTO REFILL of the water comp artment to keep the tank filled with water .
Page 7 American Met al W are Hot W ater Boiler II) III) Quick Service Check of Dual Level Control System: Description and Operation of Dual Level Control System (continued) B.
American Met al W are Hot W ater Boiler Page 8 A) B) C) Overfilling of water tank when power is off. Overfilling of water tank only when power to unit is on.
Page 9 American Met al W are Hot W ater Boiler C) D) Auto refill fails to fill water tank (continued). Auto Refill is erratic. PROBLEM IV) T rouble Shooting Auto Refill, Low Water Cutof f, and Dual Level Control System (continued) POSSIBLE CAUSE SERVICE CHECK REMEDY 3) 4) 5) 6) 7) 8) 1) 2) 3) W ater strainer clogged.
American Met al W are Hot W ater Boiler Page 10 NOTE: The level control board works on the principle that water is conductive and with some pure water inst allations, an increased senseitivity may be required in the level control system. Consult factory if this be the case.
Page 1 1 American Met al W are Hot W ater Boiler Read installation instructions- thoroughly . Failure to comply can result in valve failure or system damage or personal injury . Do not use solenoid valves on applications or fluid media not specifically cataloged without prior approval of Alco Engineering Department.
American Met al W are Hot W ater Boiler Page 12 Diassembly Disassemble in the same general order as indicated in exploded-view illustrations except as noted in the following steps: 1. 2. 3. Notes: Do NOT Lose Nameplate, as it is extremely important if it becomes necessary to order a parts kit, coil or duplicate valve .
Page 13 American Met al W are Hot W ater Boiler Part s List 815, 830, 850 - Electric, Gas or S team Heat AMW Part # Description 522004 Aluminum Gauge Shield Only for 815 - 5/8” x 13” 522006 Alumin.
American Met al W are Hot W ater Boiler Page 14 RED HEA T FILL H H XL HI C GREEN.
Grindmaster® Coffee Grinders and Brewers • Espressimo® Espresso Machines • Crathco® Hot Beverage Dispensers Crathco® Cold and Frozen Beverage Dispensers • American Metal Ware® Coffee and Tea Systems Tel (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 P.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Grindmaster 815 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Grindmaster 815 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Grindmaster 815 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Grindmaster 815 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Grindmaster 815, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Grindmaster 815.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Grindmaster 815. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Grindmaster 815 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.