Manuale d’uso / di manutenzione del prodotto 96A637 del fabbricante Graco
Vai alla pagina of 30
Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001 W ALL MOUNT OR FLOOR ST AND 4:1 Ratio, Glutton r Circulation Packages For heavy–duty , medium–volume circulation of fluids.
2 310564 T able of Contents List of Models 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Component Identification 5 . . . . . . . . . . . .
310564 3 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
4 310564 W ARNING MOVING P ARTS HAZARD Moving parts, such as the air motor piston, can pinch or amputate your fingers. D Keep clear of all moving parts when starting or operating the pump. D Before servicing the equipment, follow the Pressure Relief Procedure on page 10 to prevent the equipment from starting unexpectedly .
310564 5 Component Identification TI0957 Fi g . 1 Model 96A637 Shown KEY A Pump Inlet B Fluid Gauge and Dampener C Fluid Gauge Ball V alve D Fluid Filter E Filter Ball V alve F Fluid Drain V alve G Ai.
6 310564 Setup W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10. Site Preparation Fig. 1. Relieve system pressure. For installing any one of the packages listed in this manual, select a site with at least 5 ft (1.
310564 7 Setup W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10. W all Mount installation of the Circulation Package Fig. 1. The circulation package consists of the pump mounted on the wall mount frame.
8 310564 Setup Connect the Fluid Lines Fig. 1. Connect system fluid supply line to the circula- tion package at fluid supply inlet (A). Close filter ball valves (E) to isolate the circulation package from the main fluid supply line. Connect circulation package to the system fluid return line at fluid return outlet (T).
310564 9 Setup Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the circulation pack- age, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 4. 1. Pump: use the ground wire and clamp (A, sup- plied).
10 310564 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally .
310564 11 Operation TI0957 Fi g . 4 Model 96A637 Shown Side View 23 Ref 5 14 Ref BB AA CC DD W Y 23 14.
12 310564 Operation Starting and Adjusting the Pump 1. Fig. 4. Open all fluid shutoff valves (5–two). Make sure Air Regulator (CC) is fully closed. 2. Open the spray gun at the last gun station and keep it open while starting the pump. 3. Open the bleed-type master air valves (W , AA).
310564 13 Maintenance Preventive Maintenance Schedule The operating conditions of your particular system determine how often maintenance is required. Estab- lish a preventive maintenance schedule by recording when and what kind of maintenance is needed, and then determine a regular schedule for checking your system.
14 310564 Maintenance Air Filter Service 1. Fig. 4. Every day , drain contaminants from the bowl before reaching the baffle level by opening the drain at the bottom of the bowl (BB). W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10.
310564 15 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure (page 10).
16 310564 Parts Right Hand Mount Model: 96A637 4:1 Ratio, Glutton Pump TI0957 11 13 14 14 5 4,3 24 5,4,3 14 19 53,21,20 12,4,3 22 13 51 7 35 50 36 45 43 4,3,2 1 15 16 17 23 3,4 14 Ref Ref 5 Detail A D.
310564 17 Parts Right Hand Mount Model: 96A637 4:1 Ratio, Glutton Pump Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 618216 FRAME, wall/floor stand mount 1 2 618217 MANIFOLD, sur.
18 310564 Parts Left Hand Mount Model: 96A638 4:1 Ratio, Glutton Pump TI0958 11 13 14 14 5 3,4 24 3,4,5 14 19 20,21,53 3,4,12 22 13 51 7 35 50 36 45 43 2,3,4 1 15 16 17 23 3,4 14 Ref 5 Ref Detail A De.
310564 19 Parts Left Hand Mount Model: 96A638 4:1 Ratio, Glutton Pump Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 618216 FRAME, wall/floor stand mount 1 2 618217 MANIFOLD, surg.
20 310564 Parts Right Hand Mount Dual Filter Model: 96A938 4:1 Ratio, Glutton Pump TI0959 11 13 14 14 5 4,3 24 5,4,3 14 19 53,21,20 12,4,3 22 13 51 7 35 50 36 45 43 4,3,2 1 15 16 17 23 3,4 14 Ref Ref .
310564 21 Parts Right Hand Mount Dual Filter Model: 96A938 4:1 Ratio, Glutton Pump Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 618380 FRAME, wall/floor stand mount, rh 1 2 6182.
22 310564 Parts Left Hand Mount Dual Filter Model: 96A939 4:1 Ratio, Glutton Pump TI0960 11 13 14 14 5 3,4 24 3,4,5 14 19 20,21,53 3,4,12 22 13 51 7 35 50 36 45 43 2,3,4 1 15 16 17 23 3,4 14 Ref 5 Ref.
310564 23 Parts Left Hand Mount Dual Filter Model: 96A939 4:1 Ratio, Glutton Pump Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 618381 FRAME, wall/floor stand mount, lh 1 2 61821.
24 310564 Parts Single Mount Floor Stand, Model 618613 Model 618613 9/16 in. (4) places 3/8 in. (8) places TI0999.
310564 25 Parts Dual Mount Floor Stand, Model 618314 Model 618314 9/16 in. (4) places 3/8 in. (8) places TI1000.
26 310564 T echnical Data 4:1 Ratio Glutton Pumps Category Data Maximum Fluid Working Pressure 2.4 MPa, 24.5 bar (350 psi) Air Operating Range 0.17–0.6 MPa, 1.7 – 6.2 bar (25 – 90 psi) Fluid Flow at 60 Cycles per Minute 21.2 liter/min (5.6 gpm) Cycles Per Liter (gallon) 2.
310564 27 Notes.
28 310564 Dimensions Mount the circulation package so the top of the bracket is 5 to 6 ft (1.5 to 1.8 m) above the floor . 1 Ensure that there is 5 ft (1.5 m) overhead clearance for wall mounted systems and at least 7 ft (2.1 m) for floor mounted systems.
310564 29 Mounting Hole Layout 1 Check th at th e wal l fr ame is level before bolting it to the wall. 2 Mount the wall frame so the top edge is 5 to 6 ft (1.5 to 1.8 m) above the floor . 2 27.0 in. (685.8 mm) W all Frame 618313 1 3/8 in. (8) places 0.
30 310564 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 96A637 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 96A637 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 96A637 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 96A637 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 96A637, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 96A637.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 96A637. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 96A637 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.