Cycle Detection and Luer Lock Outlet Sho wn 332089B EN Operation - Maintenance Dispensit 1092 P atented meter and dispense system for precise one-component micr o-dispensing.
2 332089B Contents W arnings ................................. 3 Isocy anate Conditions ...................... 5 Material Self-ignition ....................... 5 Moisture Sensitivity of Isocy anates ............ 5 Changing Materials ..................
Warnings 332089B 3 W arnings The f ollowing w ar nings are f or the setup , use, grounding, maintenance , and repair of this equipment. The e xclama- tion point symbol aler ts you to a general w arning and the hazard symbol refers to procedure-specific risk.
Warnings 4 332089B ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper g rounding, setup , or usage of the system can cause elec- tric shock. • T ur n off and disconnect pow er cord before servicing equipment. • Use only grounded electrical outlets.
Isocyanate Conditions 332089B 5 Isocy anate Conditions Material Self-ignition Moisture Sensitivity of Isocy anates ISO will react with moisture (such as humidity) to f or m small, hard, abrasiv e cr ystals, which become sus- pended in the fluid. Eventually a film will f or m on the sur- f ace and the ISO will begin to gel, increasing in viscosity .
Grounding 6 332089B Gr ounding This product must be grounded. In the e vent of an elec- trical shor t circuit, grounding reduces the risk of electr ic shock b y providing an escape wire f or the electr ic cur- rent. Metering valve: attach g round wire from grounding lug to true ear th ground.
Optional Cycle Detection Sensors 332089B 7 Optional Cyc le Detection Sensor s The sensors are magnetic reed s witches and must be connected to an electrical control package. The sensors wires are #24 awg and ha v e 9 f oot (2.7 meters) flying leads. An LED on the sensor illuminates to indicate a change in state.
Component Identification 8 332089B Component Identification T ypical System Configurations F IG .1 R GREEN GREEN YELLOW YELLOW 0 TIMER DISPENSE Liquid Control R PRESSURE SYSTEM REG-1 REG-2 AUXILIARY P.
Component Identification 332089B 9 T ypical Feed System Components F IG .2 DO NOT SERVICE WITHOUT REMOVING AIR PRESSURE AND WEARING SAFETY GLASSES. WARNING F 200 psi 0 20 oz Car tridge Feed with Mount.
Component Identification 10 332089B T ypical Feed System Components (continued) F IG .3 R 0 12 8 4 psi 30 22 19 15 26 R 0 12 8 4 psi 30 22 19 15 26 5 Gallon T ank with Diaphragm Pump and Stand 5 Gallo.
Component Identification 332089B 11 Metering V alve F IG .4 GREEN GREEN YELLOW YELLOW 04 3 2 18 72 1 0 9 6 5 9 8 7 35 6 4 Key: A Material Inlet C Grounding Lug D Spool E Metering Rod F Oil Cup Retaini.
Setup 12 332089B Setup NO TE: See T ypical Installation diagram. 2. 3. P erform Setup procedure for f eed system compo- nents. See f eed system manual(s). 4. Place an in-line air pressure regulator , air-water separator/filter , and shut-off/bleed v alv e between the air supply and the control solenoids.
Setup 332089B 13 V alve Mounting Diagram As desired, use the f ollowing diagr am to mount the metering valv e. F IG .6 GREEN GREEN GREEN MODEL 1092-10A YELLOW YELLOW GREEN GREEN YELLOW YELLOW 2 = 1&qu.
Startup 14 332089B Star tup 1. Lubricate the meter ing rod por t in the oil cup retain- ing bloc k and fill the spool v alve ports with compati- ble lubricant such as mesamoll or silicone oil. 2. Pressurize the f eed systems connected to the metering valv e to prime the system.
Adjusting the Shot Size 332089B 15 Adjusting the Shot Size 1. Rotate the shot size loc king ring counterclockwise to loosen. 2. Rotate the shot size adjuster to adjust shot siz e. 3. Rotate the shot size loc king ring clockwise to tighten. 4. Dispense into waste container to test shot siz e.
Operation 16 332089B Operation The operation of the 1092 metering valv e is controlled by an e xter nal source. If a 4104A Control Bo x was pur- chased, see the 4104A Control Bo x manual f or opera- tion instructions.
Pressure Relief Procedure 332089B 17 Pressure Relief Pr ocedure 1. Retract the metering rods. See the 4104A Control Bo x manual. 2. Close the fluid shut-off v alve . 3. Remov e needle. 4. Dispense 5 shots. Shots should be at least 75% of the full stroke .
Troubleshooting 18 332089B T r oubleshooting Schematics For standard mac hines, the schematics will be included in the 4104A P ar ts manual. For custom machines, the schematics will be included in the assembly dr awings man ual. P erform Pressure Relief Procedure bef ore perf or m- ing any troub leshooting procedure.
Rebuild 332089B 19 Reb uild Disassembl y Ref er to F IG . 8 for part references in the f ollowing proce- dure. 1. For models with cyc le detection sensors, discon- nect the electrical power from the cycle detection sensors. Note the position of the sensors , then remov e them b y loosening the set screws and slid- ing them out carefully .
Rebuild 20 332089B 8. Remov e the Scre ws, that hold the Needle Bloc k Assembly to the Inlet Bloc k. The Needle Block Assembly ma y look different than the illustration as it ma y hav e multiple needles . If the needle is a remov ab le #10-32 or Luer Lock type consider removing it to protect it.
Rebuild 332089B 21 Build the Div orced Section and Mount to the Main Body 5. Place lubricated U-cup Seal (8) lip side up into the Div orced Section (10).
Electrical Requirements (Cycle Detection Option) 22 332089B Electrical Requirements (Cyc le Detection Option) F IG .9 MODEL 1092-10A GREEN YELL OW WHITE (SIGNAL) BROWN (+24DC) WHITE (SIGNAL) BROWN (+2.
Technical Data 332089B 23 T echnical Data NO TE: See f eed system manuals f or dimensions, w eights, and wetted parts lists for those components . Dimensions, weights , and wetted par ts f or components not cov ered in component f eed system manuals and f or combined assem- blies are listed belo w .
All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/patents.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 332089B è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 332089B - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 332089B imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 332089B ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 332089B, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 332089B.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 332089B. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 332089B insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.