Manuale d’uso / di manutenzione del prodotto 309868D del fabbricante Graco
Vai alla pagina of 18
For non-corrosive and non-abrasive oils and l ubricants onl y . For pr of essional use only . Not for use in e xplosive atmospheres. . Model No. 246775, Se ries B, Universal Model No. 248097, Series B, Variable Length 540 psi (3.7 MP a, 3 7 bar) Maxim um W orking Pressure 180 psi (1.
Warnings 2 309868D Wa r n i n g s The f ollowing warnings are f or the setup , use, gr ounding, maintenance , and repair of this equipment. The e xclama- tion point symbol alerts you to a gener al warning and the hazard symbol ref ers to procedure-specific risk.
Warnings 309868D 3 MO VING P ARTS HAZARD Moving par ts can pinch or amputa te finger s and othe r body p ar ts. • K eep clear of moving parts. • Do not oper ate equipment with protectiv e guards or cov ers remov ed. • Pressurized equipme nt can star t without w arning.
Installation 4 309868D Installation The typical stationar y installation shown in F IG . 1 is only a guide for selecting and inst alling a pump . It is not an actual system desig n. Contact y our Graco distrib utor f or assistance in designing a system to meet y our needs .
Installation 309868D 5 Mounting the Pump • Select a location that allows the op erator ea sy access to the pump an d air controls , sufficient room to change supply containe rs, an d a secure mounting platf orm.
Operation 6 309868D Operation See F IG . 1 to identify ref erences shown in parentheses , i.e., (A). Pressure Relief Pr ocedure 1. Close the pump air regulator ( C) and the b leed-type master air v alve (A), require d in your system.
Troubleshooting 309868D 7 T r oubleshooting Check all other possib le problems and solutions bef ore disassemb ling the pump . Bef ore y ou troub le- shoot prob lems using the tab le below , relie ve the pressure and disconnect t he pump fluid line . If the pump star ts when the air is turned on again, the fluid line, dispe nsing va lve , etc.
Air Motor and Throat Service 8 309868D Air Motor and Thr oat Ser vice Bef ore Y ou Star t • Be sure you hav e all necessar y par ts on hand. Pump Repair Kit 246918 in cludes repair parts for the pump and air motor . Use all the pa r ts in the k it f or the best results .
Air Motor and Throat Service 309868D 9 12. Remov e the o–ring (18*) from the ai r motor piston (34). 13. Clamp the displacement r od upright in the vice b y closing the vice ja ws on the flats of the displa ce- ment rod. 14. Use a screwdriver to push down on the tr ip rod yo ke (2 3) to snap the togg le assemb lies (L) down.
Air Motor and Throat Service 10 309868D 9. Align the holes in the v alve n u ts (24*) and the slot s on the stems of the inle t valv e po ppets (32*). Drop the loc k wires (25*) through th e holes in the v alve nuts and into t he slots in the stems of the in let v alve poppets.
Air Motor and Throat Service 309868D 11 16. Pull t he tr ip rod (40) so it is sticking up out of the air motor cylinder (35). 17. Grip the trip rod (40) with padded pliers , screw the cylinder cap nut ( 39) onto the trip rod, push the cyl- inder cap n ut down, and screw it into the top of the cylinder .
Displacement Pump Service 12 309868D Displacement Pump Service Be sure you hav e all necessar y par ts on hand. Pump Repair Kit 2 46918 includes repair par ts f or the pump and air motor .
Displacement Pump Service 309868D 13.
Parts 14 309868D Pa r t s 39 15 35 25* 24* 17* 24* 32* 105 29 34 18* 26 10 40 23 38 20 37 36 13* 19 46 28a 9 47 7 28 16* 103* 100 107 102* 104* 27 31* 30 108 101 106 1 1 Lips f ace down.
Parts 309868D 15 Model No. 246775, Series B, Universal Model No. 248097, Series B, V a riable Length Air Motor Pump *Included in Pump Repair Kit 246918 . ** Use gap adjustment tool 15E796 (also included in Repair Kit 246918) to ensu re correct gap sett ing f or poppets .
Technica l Data 16 309868D T echnical Data (Data measured with 10 weight oi l at 70°F (21°C) Fluid to air ratio ............. ............. ................ ............. .. 3 :1 Cycles/gallon (cy cles/liter) ... ................ ......... 43.5 (11.
Dimensional Drawings 309868D 17 Dimensional Dra wings 4.250 in. (10.8 cm) bolt circle 0.281 in. (7 .1 mm) dia meter cle arance holes Mounting Hole La y out 4.250 in. (10.8 cm) bolt circle 0.266 in. (6.7 mm) dia meter clear ance holes Pump Base Order gasket 15R881 f or sealed tank/drum mounting.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. T his manual contains English.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 309868D è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 309868D - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 309868D imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 309868D ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 309868D, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 309868D.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 309868D. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 309868D insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.