Manuale d’uso / di manutenzione del prodotto 225 del fabbricante Graco
Vai alla pagina of 34
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2004, Graco Inc. is r egistered to I. S. EN ISO 9001 Installation and Operation Fire-Ball ® 225, 300, and 425 Oil Pumps For non-corr osive and non-abrasive oils and lubricants onl y . Mini Fire-Ball 225, 3:1 Parts 246775 and 248097 540 psi (3.
Contents 2 Installation and Operation Contents Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 P ackages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Manual Con ventions . . . . . . . . . . . . . .
Packages Installatio n and Operation 3 Pa c k a g e s Model/ P acka ge No. Pump Description Hose/ Fitting Kit Cover /Bung Adapter Dispense Kit Air Regulator Fire-Ball 225 Packages 248230 246775 Univ e.
Manual Conventions 4 Installation and Operation Man ual Con ventions W a rning Caution Note WARNING A warning aler ts you to possib le serious injury or death if you do not f ollow instructions. Symbols, such as fire and e xplosion (s hown), alert you to a specific hazard and direct y ou to read the in di- cated hazard warnings beginning on page 4.
Warning Installatio n and Operation 5 W ARNING SKIN INJECTION HAZ ARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce ski n. This may look lik e just a cut, but it is a serious injur y that can result in amputation. Get immediate su rgical treatmen t.
Installati on 6 Installation and Operation Installation The typical stationar y insta llation shown in is only a guide f or selecting and insta lling a pump; it is not an actual system d esign. Cont act your Graco distr ibutor f or assistance in designing a system to meet y our needs .
Installati on Installatio n and Operation 7 Mounting the Pump • Select a location th at allows the oper ator easy access to the pump an d air controls , sufficient room to change supply containe rs, and a secur e mount- ing platf orm.
Installati on 8 Installation and Operation Universal Pump Fire-Ball 225 Model 248230 Fire-Ball 300 Model 225852 Fire-Ball 425 Model 225853 1. Apply thread sealant to the male th reads of th e 3/8 npt s wiv el union (2d). Scre w the union into the pump air inlet (D).
Installati on Installatio n and Operation 9 16-Gallon (60 Liter) Gear Lube Dispenser Fire-Ball 225 Model 246903 Fire-Ball 300 Model 225728 1. Assemb le the base (5) as sho wn in F IG . 4. Place an opened 16-gallo n (60 liter) drum on the base and secure it with the hold-do wn clamps .
Installati on 10 Installation and Operation 16-Gallon (60 Liter) Drum Cover Pump Fire-Ball 225 Model 246904 Fire-Ball 300 Model 225094 1. Set the co ve r (4) on a 16-gallon (60 liter) drum and secure with the thumbscrews (Q).
Installati on Installatio n and Operation 11 55-Gallon (208 Liter) Drum Cover Pump Fire-Ball 225 Model 246906 Fire-Ball 300 Model 225642 Fire-Ball 425 Model 225782 1. F or 24690 6 cut the e xtension tub e (P) at a 45° a ngle to a length appropriate f or the size of the drum.
Installati on 12 Installation and Operation 55-/275-Gallon (2 08 Liter) Drum, Bung-Mount Pump Fire-Ball 225 Model 246907 Fire-Ball 300 M odels 225640 and 225931 1. Scre w the bu ng adapter (M) into the bung hole of the drum. See F IG . 7. 2. F or 24690 7 cut the e xtension tub e (P) at a 45° angle to a length appropriate f or the size of the drum.
Installati on Installatio n and Operation 13 Mobil Mounting Mobil Mounting Lay out Plan the la y out f or easy operator access to th e pump air controls , sufficient space to change drums, and a secure mounting platf or m. Drum Mounting 1. Place the dr um in the desired loca tion.
Installati on 14 Installation and Operation Closed Bung-T ype-Drum, Sturdi-Clamp-Mounted Pumps 1. Remo ve the adjustab le bun g adapter fro the pump e xtension tube . 2. Scre w the bung a dapter (HH) into the b ung hole . 3. Loosen the wing nuts (EE) and slide th e clamp (DD) onto the pump e xtension tube, up to th e base.
Operation Installatio n and Operation 15 Operation See F IG . 1 to identify r efer ences shown in parentheses , i.e.,(A). Reliev ing Pressure 1. Close the p ump air regulator ( C) and the b leed-type master air v alv es (A) ( required in y our system).
Parts 16 Installation and Operation Pa r t s Univer sal Pump P ac kage Fire-Ball 225 Model 248230 Fire-Ball 300 Model 225852 Fire-Ball 425 Model 225853 2b 2a 2d 2c 1.
Parts Installatio n and Operation 17 P art s List Ref. No. P ar t No. Description Qty . 1 246775 PUMP , Mini-Fire-Ball 225 3: 1, univ ersal; (f or 248230, see 3098 69 for pa r ts ) 1 203876 Pump, Fire.
Parts 18 Installation and Operation 16-gallon (60 Liter) Gear Lube Dispenser Fire-Ball 225 Model 246903 Fire-Ball 300 Model 225728 1 3c 3d 3b 3d 2a 2b 5 4 3a.
Parts Installatio n and Operation 19 P art s List Ref. No. Pa rt No. Description Qty . 1 248097 PUMP , Mini-Fire-Ball 225 3:1, multi-length ; (f or 246903, see 309869 f or parts) 1 203872 PUMP , Fire-.
Parts 20 Installation and Operation 16-gallon (60 Liter) Drum Co ver Pump Fire-Ball 225 Model 246904 Fire-Ball 300 Model 225094 2b 2a 2d 2c 1 3d 3b 3d 3c 4 3a.
Parts Installatio n and Operation 21 P art s List Ref. No. Pa rt No. Description Qty . 1 248097 PUMP , Mini-Fire-Ball 225 3:1, multi-length ; (f or 246904, see 309869 f or parts) 1 203872 PUMP , Fire-.
Parts 22 Installation and Operation 55-gallon (208 Liter) Drum Co ver Pump Fire-Ball 225 Model 246906 Fire-Ball 300 Model 225642 Fire-Ball 425 Model 225782 2b 2a 2d 2c 1 3d 3b 3d 3a 3c 4.
Parts Installatio n and Operation 23 Ref. No. Pa rt No. Description Qty . 1 248097 PUMP , Mini-Fire-Ball 225 3:1, multi-length ; (f or 246906, see 309869 f or parts) 1 203857 PUMP , Fire-Ball 300 5:1;.
Parts 24 Installation and Operation 55-/275-gallon (208 Liter) Drum Bung-Mount Pump Fire-Ball 225 Model 246907 Fire-Ball 300 Model 225640 Fire-Ball 300 Model 225931 Fire-Ball 425 Model 225786 2b 2d 1 .
Parts Installatio n and Operation 25 P art s List Ref. No. Pa rt No. Description Qty . 1 248097 PUMP , Mini-Fire-Ball 225 3:1, multi- length; (f or 2469 07, see 309869 f or par ts) 1 204254 PUMP , Fir.
Parts 26 Installation and Operation 16-gallon (60 Liter) Drum Co ver , T ruc k Mounted Pump Fire-Ball 300 Model 222086 P art s List 2a 2b 2c 2d 3 4 Ref. No. Pa rt No. Description Qty . 1 203872 PUMP , Fire-Ball 300 5:1; (See 309869 f or parts) 1 2 222063 HOSE AND FITTING KIT Includes items 2a -2d 1 2a 22 0591 • HOSE, fluid; nitrile; 1/2 in.
Parts Installatio n and Operation 27 55-gallon (208 Liter) Drum Co ver , T ruc k Mounted Pump Fire-Ball 300 Model 206655 Fire-Ball 425 Model 206656 P art s List 2a 2b 2c 2d 3 4 Ref.
Parts 28 Installation and Operation 55-gallon (208 Liter) Bung Adapter , T ruck Mounted Pump Fire-Ball 300 Model 204264 Fire-Ball 425 Model 222067 2c 3 5 1 4 2a 2b 2d.
Parts Installatio n and Operation 29 P art s List Ref. No. Pa rt No. Description Qty . 1 204254 PUMP , Fire-Ball 300 5:1; (F or 204264, see 30 9869 f or par ts) 1 222095 PUMP , Fire-Ball 425 10: 1; (F.
Technical Data 30 Installation and Operation T echnical Data Fire-Ball 225 (3:1) Fluid to air ratio ................. ................ ............. ........... 3:1 Cycles/gallon (cy cles/liter) ......... ............. ...... 43.5 (11.4) Fluid flow @80 cpm (g pm/lpm) .
Dimensions Installatio n and Operation 31 Dimensions Fire-Ball 225 grounding screw 1/2 in. npt(f) fluid outlet 3/8 in. npt(f) air inlet 8.9 in. (20 cm) 40.68 in. (103.33 cm) drop tube is cut to length Model 246775 Universal Overall Length: 18.9 in. (48 cm) Model 248097 Variable length Overall Length: 59.
Dimensions 32 Installation and Operation Fire-Ball 300 M o d e l 203857 55-gal. (400 lb) drum size, cover mount Overall Length: 45.6 in. (115.8 cm) Model 203872 16-gal. (120 lb) drum size, cover mount Overall Length: 38. 1 in. (96.8 cm) Model 204254 55-gal.
Dimensions Installatio n and Operation 33 Fire-Ball 425 45_ M o d e l 205626 Universal Mounting Hole Layout 3/4 in npt muffler port 1/2 in. npt air inlet 3/4 in. npt fluid outlet 06035 Four 0.406-in. (1.03 cm) diameter holes on 7-in. (17. 8 cm) bolt circle Note: For sealed tank mounting use gasket 192658.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. MM 309868 Graco Headquarters: Minneapo lis International Offices: Belgium, China, Japan, Korea GRACO INC.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Graco 225 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Graco 225 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Graco 225 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Graco 225 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Graco 225, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Graco 225.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Graco 225. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Graco 225 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.