Manuale d’uso / di manutenzione del prodotto CPLM 12KE-B-410 del fabbricante Amcor
Vai alla pagina of 15
PORT ABLE AIR CONDITIONER GB Portable air conditioner CPLM 9KE-B-410 12KE-B-410 15KE-B-410.
2 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference.
3 • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer , its service agent or a qualified person in order to avoid a hazard.
4 Slide bar connector Active carbon filter T elescopic slide bar Exhaust hose W ater container Remote control with LCD PA R T S 1 2 3 4 10 6 5 8 7 9 3 1. Air outlet 2. Control panel 3. C arrying handle 4. Caster wheels 5. Grill housing 6. Upper air inlet 7.
5 CON TROL P ANEL Mode Increase Decrease Swing ON / OFF Fa n Timer Sleep mode Sensor remote control Clock/ Cooling Sleep Timer mode T emperature F an Timer settings GB.
6 INS T ALL A TI ON WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another . In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles.
7 ON/OFF Press to switch the unit on or to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash.
8 Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00.
9 Air flow On the moment the air conditioner is connected to the mains, the louvres open and close and stay closed. • When the ON-button is pressed, the louvres open to maximum and return to an angle of 75° above the upper plane of the louvres housing.
10 The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function.
11 This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air , which includes a. A screen filter , to remove dust particles. b. An active carbon filter , to remove odours. 2.
12 EMP T YING THE INTER NAL W A TER CONT AINE R Under high humidity conditions it may be necessary to empty the internal water container . When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically .
13 Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property . Problem Cause Solution The air conditioner does not function. No power supply . Connect to a functioning outlet and switch on.
14 Reminder: W aste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. TECHNI CA L DA T A Model CPLM 9KE-B-410 CPLM 12KE-B-410 CPLM 15KE-B-410 Cooling capacity measured conform EN 14511 BTU/h 7500 9900 11300 kW 2.
0 7 1 4 2 1 3 1 9 N / P - M L P C Hong Kong China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Amcor CPLM 12KE-B-410 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Amcor CPLM 12KE-B-410 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Amcor CPLM 12KE-B-410 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Amcor CPLM 12KE-B-410 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Amcor CPLM 12KE-B-410, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Amcor CPLM 12KE-B-410.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Amcor CPLM 12KE-B-410. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Amcor CPLM 12KE-B-410 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.