C US ® *NOTE: Please contact your distributor or our website for the applicable S pecification Sheets referred to in this manual. RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. A TTENTION INST ALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Inst allation Manual.
2 W ARNIN G I NSTALLATION AN D REP AIR OF THIS UNI T SHO ULD BE PERFO RMED ON L Y BY IN DIVI DUALS MEE T I NG THE REQUIREMENTS OF AN “E NTRY L EVEL T ECHNICIAN ” AS SPECIFIED BY THE A IR -C OND ITI ONI NG , H EATI NG , AN D R EFR IGE RAT IO N I NST ITUT E (AHR I).
3 “Product Registration” located on the left side of the Warranty page and complete the forms in the manner indicated on the Product Registration page. Product limited warranty certificates for models currently in production can be viewed at www .
4 The information on the rating plate is in compliance with the FTC & DOE rating for single phase units. The three phase units in this series are not covered under the DOE certified program.
5 Rooftop Installation R OOF C URB I NSTALLATIONS O NLY NOTE: Sufficient structural support must be determined prior to locating and mounting the curb and package unit. Curb insulation, cant strips, flashing and general roofing material are furnished by the contractor .
6 Remov e these c overs for hor iz o ntal duct applic ations Remove these panels for do wnflow duct applicat ions Supply Return Duct Cover Installation Down Discharge Applications Cut insulation around bottom openings and remove panels from the bottom of the unit, saving the screws holding the panels in place.
7 WIRING NOTE: All wiring should be made in accordance with the National Electrical Code. Consult your local Power Company to determine the availability of sufficient power to operate the unit. Check the volt age, frequency , and phase at the power supply to ensure it corresponds to the unit’s RA TED VOL T AGE REQUIREMENT .
8 BRANCH CIRC UIT A MPA CITY 15 20 25 30 35 40 45 50 SUPPLY WI RE LENGTH - FEET 2 0 0 64443322 1 5 0 86644433 1 0 0 1 0 8866644 5 0 1 4 1 2 1 0 1 0 8866 2. Wire size based on 60° C rated wire insulation and 30° C Ambient T emperature (86° F). 3. For more than 3 conductors in a raceway or cable, see the N.
9 Crankcase Heater This item is “ON” whenever power is supplied to the unit and the crankcase heater thermostat is closed. Crankcase heater thermostat closes at 67° and opens at 85°. It warms the compressor crankcase thereby preventing liquid migration and subsequent compressor damage.
10 supplementary heat for all heat pump installations in areas where the temperature drops below 45° F . It is also a good practice to provide sufficient supplementary heat to handle the entire heating requirement should there be a component failure of the heat pump, such as a compressor , or refrigerant leak, etc.
11 0.1 0. 2 0.3 0.4 0. 5 0.6 0.7 0. 8 CFM 1122 1078 1032 972 915 804 687 558 W A TTS 338 330 321 310 300 283 264 250 CFM 1387 1331 1264 1209 1119 1041 935 748 W A TTS 456 440 428 412 399 382 363 330 C.
12 S PEED T AP A DJUSTMENTS F OR I NDOOR B LOWER M OTOR PSC Motor Adjust the CFM by changing the speed tap of the indoor blower motor at the EBTDR “COM” connection with one of the speed taps on “M1” or “M2”. (Black-High S peed, Blue-Medium S peed, Red- Low S peed.
13 Un it Mod el Nu mb er 5 8 10 15 2 0 G PH13 24M 41 ** M (F ) M (F ) M (F ) HN A G PH13 30M 41 ** M (F ) M (F ) M (F ) HN A G P H /G PC1 336M41* * MM H (F ) H (F ) NA G PH13 42M 41 ** MM H (F ) H (F .
14 TROUBLESHOOTING CHART SYMPTOM High head - low suct ion a. Restr i c ti on i n li qui d li ne or f lowr ato r a. Remov e or r epl ace wi th pr ope r s iz e f l o wr a t or . High head - hi gh or nor ma l s ucti on a. Dirt y c ondense r c oil a. Cle an c oi l.
15 APPENDIX UNIT DIMENSIONS BLOWE R ACCESS P ANEL ? ? 2 34 51 47 SUP PL Y 1 3/8 A RETURN POW ER WI RE ENT RANCE 4 1/8 2 1/8 6 ½ 16 16 5 ½ B B CONTROL WI RE ENT RANCE CONDENSA TE DRA I N CONNECTION 3.
16 MINIMUM CLEARANCES RECOMMENDED FIL TER SIZES 3" MI N 12 " M IN 36 " M I N (FOR SER VICE) . 48 " M IN 12 " M IN 36 " M IN (F O R SE RVIC E) NOTE: Roof overhand should be no more than 36” U N I T 2 ton 2 -1 /2 ton 3 to n 3 -1 /2 to n 4 to n 5 ton M i n.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Goodman Mfg IO - 395 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Goodman Mfg IO - 395 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Goodman Mfg IO - 395 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Goodman Mfg IO - 395 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Goodman Mfg IO - 395, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Goodman Mfg IO - 395.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Goodman Mfg IO - 395. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Goodman Mfg IO - 395 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.