Manuale d’uso / di manutenzione del prodotto P300 del fabbricante Giant
Vai alla pagina of 16
Series P 300 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: page 2 Pump Specifications: pages 3-7, 10 Exploded View: page 8 Parts L.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
4 Specifications Model P316 U.S. (Metric) 1450 RPM Ratings (Continuous) .................................... 4.4 GPM @ 3000 PSI ..... (16.7 LPM @ 200 bar) Ratings (Intermittent) .................................... 4.4 GPM @ 3500 PSI ..... (16.7 LPM @ 240 bar) 1750 RPM Ratings (Continuous) .
5 Specifications Model P317 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
NPSHR (FT -HEAD) 50 68 86 104 122 140 158 176 194 212 230 0 F 69.0 66.0 62.3 59.0 56.8 52.5 49.2 46.0 43.0 39.3 36.0 33.0 30.0 26.2 1 7 3 0 R P M 6 . 2 2 G P M 1 4 2 0 R P M 5 1 G P M P318 NPSHR Chart P318 HORSEPOWER REQUIREMENTS RPM GPM 750 PSI 1000 PSI 1500 PSI 1750 PSI 2000 PSI 810 3.
P319 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI* 3000 4.2 4.3 5.8 7.2 8.7 3200 4.5 4.7 6.2 7.8 9.3 3450 4.8 5.0 6.6 8.3 9.9 7 Specifications Model P319 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
8 Exploded View - P300 Series.
9 P300 SERIES PAR TS LIST ITEM PART NO. DESCRIPTION QTY. 1 08326 Crankcase 1 2 06773 Dipstick Assembly 1 3 08410B Crankcase Cover, Short 1 3 08410-LG Crankcase Cover, Extended 1 3 A 07190 Oil Drain Pl.
P340 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI 3500 PSI 4000 PSI* 745 1.5 1.6 2.1 2.6 3.1 3.6 4.1 1025 2.0 2.1 2.8 3.4 4.1 4.8 5.5 1340 2.7 2.8 3.7 4.7 5.6 6.5 7.4 1450 2.9 3.0 4.0 5.0 6.0 7.0 8.0 1750 3.5 3.6 4.8 6.0 7.2 8.
11 Position Item# Description T or que Amount 3 B 08410/07190 Oil Drain Plug w/ Gasket 222 in.-lbs. 6 07188/1196 Screw 43 in.-lbs 1 0 7225 Screw with Lock W asher 85 in.-lbs. 1 6 C 08456 or 08450 T ension Screw , Plunger 220 in.-lbs. 3 4 08363 Hex Head Cap Screw , V alve Casing 222 in.
PUMP SYSTEM MALFUNCTION 12 PUM P SYST EM M A L FUNC TION S MALFUN CTION CAU SE REM EDY The Pressu re and/ or t he Deliver y Dro p s W orn pac k ing se als Re pl ac e pac k ing se als Brok en valve spr.
13 REPAIR INSTRUCTIONS - P300 SERIES NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.
14 11. Inspect o-rings (#21 and 22) and replace as necessary. 9. Remove the pressure rings (#24) and grooved seals (#23) from the valve casing (#26). Inspect parts for wear and replace if necessary. For P318 only, the spacers (#23A) can now be removed.
15 Reassembly sequence of the P300 Series pump REPAIR INSTRUCTIONS - P300 SERIES 14. If the oil seals (#19) were removed, replace them with the primary seal lip (grooved side) towards the crankcase and the dust lip (tapered end) towards the valve casing (#26).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Giant P300 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Giant P300 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Giant P300 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Giant P300 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Giant P300, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Giant P300.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Giant P300. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Giant P300 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.