ST ANDBY GENERA T OR O WNER'S MANU AL This manual should remain with the unit. A ne w standar d of reliability Serial Number 1.6L 20/25/30 kW Models N ot i nt ended for us e i n c r i t i c al l i f e s uppor t appl i c at i ons. ONL Y QU ALIFIED ELECTRICIANS OR CONTRA CT ORS SHOULD A TTEMPT INST ALLA TION! DEADL Y EXHA UST FUMES.
Standby Generator Sets T able of Contents SECTION P AGE SAFETY RULES ................................................ 1-1 INTRODUCTION ..................................................... 1-3 Read this Manual Thoroughly ..............................
Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reli- ably only if it is properly installed, operated and maintained.
• Before performing any maintenance on the gen- erator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step.
1-3 I NTRODUCTION Thank you for purchasing this model of the standby generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written.
I DENTI F ICA TION REC ORD D A T A LA BE L Every generator set has a DA T A LABEL that contains important information pertinent to the generator . The data label, which can be found attached to the ge.
E QUIPM ENT DE SCRI PTION This equipment is a revolving field, alternating cur - rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units.
ENGI N E P RO TECTIVE DEVICE S The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm.
F U E L SYST E M FUE L RE QUIRE MEN T S The standby generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing .
SP E CI F ICA TIONS GEN ERA T OR T ype ............................................................................. Synchronous Rotor Insulation .................................................................... Class F Stator Insulation ..........
COLD WEA THER KIT F or cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: • Battery W armer • 4” Junction Box with hardware • 6 qt. pack 5W -30 synthetic oil (engine) R E C ON FIGU R I NG TH E FU EL SY S TEM NOTE: All models are configured to run on natural gas from the factory .
GEN ER A T OR AC LEAD C ONN ECTIONS See “V oltage Codes”. This generator may be rated at any one of three voltages, either single -phase or three -phase. The electrical wires in the unit ’s AC con- nection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application.
I NS T ALLA TION Refer to the separate “Installation Guide” supplied with the unit. P R EP AR A TION B EFOR E ST ART -UP The instructions in this section assume that the standby generator has been properly installed, ser - viced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor .
• Battery charger connection to 120 V AC. • Communication wires connected between transfer switch and generator (HTS only). • Unit secured to pad. S T ART -U P CH E CKLIS T Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position.
GEN ER A T OR CONTROL AND OP ER A TION Refer to the appropriate control panel operator’s manual for this unit. OP ER A TING U N IT WITH MAN UAL TR ANSF ER SWIT CH If the generator was installed in conjunction with a transfer switch capable of manual operation only , the following procedure applies.
MAI NTENANCE P ER FOR M ED B Y SERVICE F ACI LITIES Before working on the generator , ensure the fol- lowing: The AUTO/OFF/MANU AL switch is in the OFF position. The 15A fuse has been removed from the con- trol box. The 120V AC supply to the battery charger is switched OFF .
Figure 10.1 - Oil Dipstick and Oil Fill Cap OIL FILL CAP OIL DIPSTICK B A TTE R Y FL UID Check battery electrolyte fluid based on the Maintenance Schedule. Fluid should cover separa- tors in all battery cells. If fluid level is low , add dis - tilled water to cover tops of separators.
CHANGI NG ENGIN E OI L Refer to maintenance performed by service facilities for engine oil and filter change frequencies. Drain the oil while the engine is still warm from run- ning . This means warm up the engine, shut it down and drain immediately as follows: 1.
M IS CELL AN E OUS MAI NTENANCE CLEAN ING TH E GEN ER A T OR Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance. P eriodically clean generator exterior surfaces.
SERVICE S CH EDU LE The following is a recommended maintenance schedule for small standby and residential generator sets. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application.
Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp . Required Comp . to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- monthly Initials) Break-in Initials) annually Initials) Annually Initials) 10 Hrs.
Maintenance Level 1 Level 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp . Required Comp . to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- monthly In itials) Break-in Initials) annually Initials) Annually Initials) 10 Hrs.
TROU B LE SHOO TI NG GU I DE P ROB LEM CAUSE C OR R E CTION Engine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse. 2. Loose or corroded or defectiv e 2. Tighten, clean or replace battery cables. batter y cables as necessary . 3. Defectiv e star ter contactor .
Standby Generator Sets Notes.
Standby Generator Sets Notes.
Standby Generator Sets Notes.
Standby Generator Sets Notes.
.
1 0G4827 1 ASSY RTR 104 KD1 HI EFF ( 18KW) 0 G2927 1 RTR-102-20.0AD1 CPL (2006) (20KW) 0 G2827 1 ASSY RTR 25KW 2P (2006) (25KW) 0G34 51C 1 RTR 102 30KD2 (20 06) CPL CHI ( 30KW) 2 0G0820A 1 HO USING BLOWE R LG PILOT 3 0G4452 1 BLOWER HOUSING SCREE N 4 020746 4 SCREW PPHM M5-0.
.
1 N/A N/A UL BREAKER BQ2 A 0D5543 1 CB 0090A 2P 240V S BQ2 LL 0D5544 1 CB 0100A 2P 240V S BQ2 LL 0A2077 1 CB 0125A 2P 240V S BQ2 LL B 0G 44 99 1 CB COVER 20-25K 1P (BQ 2) C 0C2265 2 SCREW PHTT M4- 0.7 X 12 ZYC D 0C2264 2 WASHER LOCK # 8-M4 E 0E7890 1 BRKT CB M TG BACK F 0G4497 1 CIRCUIT BREAKE R SUPPORT (BQ) G 05 2619 2 SCREW HHC M 5-0.
.
C O M PO N EN T S IN CL UD ED IN 0 G 4 5 77 E 1 0 F 1 8 2 3A 1 EN C L H SB C O N T R OL P A N EL 2 0F 307 8 1 C O V E R C ON T R O L PA N E L 3 0F 260 6 1 H IN G E C O N TIN U O U S H -P A N E L 4 03 62 6 1 6 R IV E T P O P .
.
1 0G3418 1 RADIATOR SUPPORT LH SID E 1.6L 2 0G3421 1 VENTU RI 1.6L 3 0G3419 1 RADIATOR SUPPORT RH SID E 1.6L 4 0E9837B 1 RADIATOR 1 .6L CHY 5 0G3553 1 FAN COOL 450MM DIA 7 BL ADE 6 0E 3257 2 S CREW HWHTF M6-1.0 X 16 7 0G4080 1 HOSE LOWE R RADIATO R 1.
.
1 0G33 43 1 M OUNTING BASE 1 .6L 2007 C1 2 02748 2 2 WASHE R SHAKEP ROOF EXT 5/16 STL 3 07093 6 2 DAMPE NER VIBR ATION 4 07093 6C 2 VIB. ISO. 7 0-75 DURO 5 03925 3 8 SCREW HHC M8-1. 25 X 20 G 8.8 6 02214 5 1 2 WASHER FL AT 5/16 ZINC 7 02212 9 1 2 WASHER LO CK M8-5/ 16 8 04577 1 4 NUT HEX M8-1.
.
1 0F3 408C 1 BATTERY T RAY, C1 & C2 2 0F3411 1 STRAP BATTERY RETAI NMENT 3 025507 1 WASHE R SHAKEPROOF EX T 7/16 STL 4 059980 1 SCREW HHC M10-1.5 X 25 G10.9 5 046526 1 WASHE R LOCK M10 6 077483 REF BATTERY 12VDC 75-A H 26 7 050331A REF BATTERY P OST COVER RED + 8 050331 REF BATTERY POST COVE R BLK - 9 0 38805J 1 CA BLE BATTERY BLAC K #1 X 30.
.
1 0G0207 REF ENGINE GEN ERAC 1. 6L NG 2 0G0834 1 ENGINE PL ATE 1.6L 3 0G0820 REF HOUSING BLOWER MAC HINED 1.6L 4 0E 9747 1 S TARTER 12 VOLT 5 0G0839 2 ENGINE M OUNTING FOO T STAMPING 6 0G0781 1 EX HAUST MANIFOLD 1. 6L MACHINED 7 0G0722 1 INT AKE MANIFOLD MA CHINED 1.
.
1 098290 1 ASM MOTO R STEPPER 2 098941A 1 HOUSING GOVE RNOR CON NECTOR 3 098958A REF CONNEC TOR INTERFA CE ASSEMBLY 4 098942A 1 COVER CO NNECTOR HOUSI NG 5 098225 2 SCREW FHM #2 X 5/8 SELF TAP 6 043146 3 SCREW HHC M6-1.0 X 1 0 G8.8 7 022097 5 WASHE R LOCK M6-1/ 4 8 084543A 1 SCREW PHM M3- 0.
.
1 026812 2 ELBOW 90D 3/4 NPT 2 075580 1 FLANGE FUEL INLET 3 0G1397A 1 FUEL REG. RE WORK 1.6L 3600 '07 (3600RPM) 0G1397B 1 FUEL REG. REWORK 1.6L 1800 '07 (1800RPM ) 4 039253 2 SCREW HHC M8-1.25 X 20 G8.8 5 022145 2 WASHER FLAT 5/16 ZINC 6 022129 4 WASHER LOCK M8-5/ 16 7 045771 2 NUT HEX M8-1.
.
(1) 1 0G3337 1 R OOF 1.6L C1 (1) 2 0G3336 1 R EAR INTAKE W RAP 1.6L C1 (2) 3 077992 16 NUT HEX L OCK M6-1.0 SS NY INS (1) 4 0G3341 2 R IGHT SIDE DOO R 1.
.
1 0F7366 1 M UFFLER C1 2 0F7647 1 M UFFLER SADDLE 3 0F8095 1 P IPE EXHAUST O UTLET 4 0G3576 1 EX HAUST PIPE L OWER 1.6L 5 0E3257 4 S CREW HWHTF M 6-1.0 X 1 6 6 0F7644 2 M UFFLER STR AP 7 0C6119 1 BOLT U 5/16-1 8 X 2-1/4 8 036434 3 BOLT U 5/16- 18 X 2.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
BackPg001 Re v . A 04/07.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Generac Power Systems 25 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Generac Power Systems 25 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Generac Power Systems 25 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Generac Power Systems 25 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Generac Power Systems 25, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Generac Power Systems 25.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Generac Power Systems 25. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Generac Power Systems 25 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.