PO WER SY STEMS, INC. ® Owner’ s Manual GTS “W” T ype A utomatic T ransfer Switc h 200 Amp, 250 V olts Model Nos. 004635-1 004635-2 This manual should remain with the unit.
Generac ® Pow er Systems, Inc. Generac cannot possibly anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive.
T able of Cont ents Generac ® Pow er Systems, Inc. 1 Safety Rules..........................................Inside Front Cover Section 1 — General Information ..................................2 1.1 Introduction .....................................
2 Generac ® Pow er Systems, Inc. Section 1 — General Information Generac GT S “W” T ype T ransfer Switch 1.1 I NTRODUCTION This manual has been prepared especially for the purpose of familiarizing personnel with the design, application, installation, operation and servicing of the applicable equipment.
Generac ® Pow er Systems, Inc. 3 2.1 I NTRODUCTION T O I NST ALLA TION This equipment has been wired and tested at the fac- tory . Installing the switch includes the following pro- cedures: • Mounting the enclosure. • Connecting utility and generator power source leads.
4 Generac ® Pow er Systems, Inc. Solderless, screw-type terminal lugs are standard. The conductor size range is as follows: Conductor sizes must be adequate to handle the max- imum current to which they will be subjected; based on the 75°C column of tables, charts, etc.
Generac ® Pow er Systems, Inc. 5 3.1 F U NCTIONAL TE S T S AN D ADJ US TM ENT S Following transfer switch installation and intercon- nection, inspect the entire installation car efully . A competent, qualified electrician should inspect it. The installation should comply strictly with all appli- cable codes, standards, and r egulations.
6 Generac ® Pow er Systems, Inc. 3. When certain that UTILITY supply voltage is cor- rect and compatible with transfer switch ratings, turn OFF the UTILITY supply to the transfer switch. 4. On the generator panel, set the A UTO - OFF - MANU AL switch to MANU AL position.
Generac ® Pow er Systems, Inc. 7 Failure to do so may r esult in damage to cer- tain rotary equipment. 8. Set the generator’s main circuit breaker (CB1) to its OFF or OPEN position. 9. Set the Auto/Off/Manual switch to the OFF posi- tion to shut down the generator .
8 Generac ® Pow er Systems, Inc. Section 4 — Mounting Dimensions Generac GT S “W” T ype T ransfer Switch Mounting Dimensions – Drawing No. 0D3 7 1 4-B 180 514 612 490 430 V alues are in Millimeters Note: Diameter of Mounting holes (A) is 6.
Generac ® Pow er Systems, Inc. 9 - OPEN SWITCH TO TEST - 2 A @ 2 50 Vac MIN. S WITCH TYPE , SPST E LECTRICAL RATINGS , NO TE : I F THERE ARE NO MATCHING TERMINAL CONNECTIONS FOR LOAD 1 ( T1 ) AND L OAD 2 ( T2 ) IN THE GENERATOR CONTROL PANEL DO NOT CONNECT THESE W IRES , FAILURE OF THE CONTROL BOARD WILL OCCUR IF CONNECTED.
B2 A2 B1 A1 C 6 9 TR 1 7 TR E1 E1 N2A N2A N1A E2 2 05 12 6 TR 2 3 1 94 2 3 1 94 N2A LE G EN D G T S N O TE S: A LL CO NTA C T S S H O WN WIT H TRAN S FER S WIT C H IN U TILIT Y P OS ITI O N .
Generac ® Pow er Systems, Inc. 11 TR G T S T1 E1 N1 T2 E2 N2 B1 B2 A2 A1 N1A N1A 12 6 E2 E1 N2A 2 05 N1A 2 05 E1 E1 A 7 1 B 9 3 T1 T2 N1A N2A 12 6 2 05 N1A N1A N1A N1A F2 F1 23 19 4 T S U TILITY 2 U .
B2 A2 B1 A1 C 6 9 TR 1 7 TR E1 E1 N2A N2A N1B E 2 2 05 12 6 TR 2 3 1 94 2 3 1 94 N2A LE G EN D G T S N O TE S: 1. ) ALL CONTACTS SHOWN WIT H TRAN S FER S WIT C H IN U TILIT Y P OS ITI O N .
Generac ® Pow er Systems, Inc. 13 TR G T S T1 E1 N1 T2 E2 N2 B 1 B2 A2 A1 N1B N1B 12 6 E2 E1 N2A 2 05 N1B 2 05 E1 E1 A 7 1 B 9 3 6 T1 T 2 N1B N2A N 3 E 3 T 3 2 1 8 7 3 4 5 6 12 6 2 05 N2A N2A N2A N1B.
S WIT C H I S F O R US E WITH CO NTR O L M O D U LE A SS EMBLY # 079844 , #075595 , AND #083494 T RAN S FER S WIT CH W AUKESHA WI , 53187 G ENERA C P O WER S Y S TEM S 0 E4 3 1 3 3 4 23 14 LO AD 2 LO .
Generac ® Pow er Systems, Inc. 15 Section 6 — Exploded Views and P arts List Generac GT S “W” T ype T ransfer Switch 200 A, 2P ole Switch Assembly – Drawing No. 0E2868$-D ITEM P ART NO . QTY . DESCRIPTION 1 0C8884 1 XFER SW -W 200A600V2P 20 A 99 4 9 6 LUG SLDLSS 400-#4X1/4-20 CU7AL 3 0C48 9 6 6 SCREW FHM M8-1.
16 Generac ® Pow er Systems, Inc. A9949 - S A9949S 0 A 99 4 9 - S C 7 90 7D- S 0 D4 5 4 5 C7907DS 0C8885 -L S 0A9949 - S 0A9949S 7 39 40 RATED VOLTAGE 600 VA C CS A 480 VA C U L XXXXXX A1 CS3-8X16T C.
Generac ® Pow er Systems, Inc. 17 ITEM P ART NO . QTY . DESCRIPTION 1 0C8885 1 XFER SW -W 200A600V3P 20 A 99 4 99 LUG SLDLSS 400-#4X1/4-20 CU7AL 3 0C48 9 6 9 SCREW FHM M8-1.25 X 20MM CR 4 067 9 8 99 NUT LOCK FL M8-1.25 YEL CHR 5 026 9 02 7 SCREW HHTT #8-32 X 1/4 CZ 6 0C7 9 07D 2 CO VER LUG 3P 150/200AMP 7 045771 1 NUT HEX M8-1.
Part No. 0E4334 Revision C (05/05/05) Printed in U.S.A. Section 7 — W arranty Generac GT S “W” T ype T ransfer Switch GENERA C PO WER SYSTEMS ST AND ARD TWO-YEAR LIMITED W ARRANTY FOR GENERA C TRANSFER SWITCH SYSTEMS NO TE: ALL UNITS MUST HA VE A ST ART -UP INSPECTION PERFORMED BY AN A UTHORIZED GENERAC DEALER.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Generac Power Systems 004635-2 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Generac Power Systems 004635-2 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Generac Power Systems 004635-2 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Generac Power Systems 004635-2 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Generac Power Systems 004635-2, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Generac Power Systems 004635-2.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Generac Power Systems 004635-2. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Generac Power Systems 004635-2 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.