Manuale d’uso / di manutenzione del prodotto Ventila del fabbricante GE
Vai alla pagina of 12
Use and Care of Recirculation Hood Models JN322, JN334, JN335, JMW, & JN635 and Ventilating Hood Models JV322, JV324, JV332, JV334, JV335, JV624, JV634, & JV635 — IMPORTANT SAFETY C. When cutting or drilling into wall or ceiling, INSTRUCTIONS do not damage electrical wiring and other hidden utilities.
2 If You Need Service... ● Do not attempt to repair or replace any part of 1 your hood unless it is speciikxdly recommended in this book. All other servicing should be referred to a qualified technician. ● Disconnect hood circuit breaker or fuse before performing any service.
To Operate —Vents (“JN” models only) Lamp switch Fan switch Trim Lamp Switch Models: JN322, JV322 & JV332 Press for OFF and ON. Lamp Stitch All other models. CENTER position OFF, LE~ position NIGHT LIGHT, RIGHT position BRIGHT LIGHT. Fan Switch CENTER position OFF, LEFT position LOW SPEED, RIGHT position HIGH SPEED.
Installation Instructions for General Electric Hood Models: JN322, JN334, JN335, JN634, JN635, JV322, JV324, JV332, JV334, JV335, JV624, JV634, JV635 Important-save for the local electrical inspector% use Power supply connection box on underside of hood.
1. PREPARATION OF WALL CABINET AND WALL FLUSH OR RECESSED BOITOM CABINET NOTE: For easier installation make all hood and vent cutouts in the cabinet and wall before cabinet is permanently fastened in place. It is recommended that the power supply be brought into the hood from the wall below the cabinet as shown in Fig.
2. DUCT INSTALLATION T@e “B” Models: See Figs. 4 and 9. The hood exhaust has been designed to mate with standard 7“ round duct. (A round damper kit may be ordered. Order GE model number JXDA22.)* A. If a rectangular duct is desired, a round-to-rectangular adapter must be used.
3. POWER SUPPLY A. CIRCUIT VOLTAGE: This hood must be connected to a supply circuit of the proper voltage and frequency as specified on the rating plate. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for hoods of this rating.
IMPORTANT: After installation, peel off the transparent protective film stripping from the decorative trim on the front of the hood. (See Fig. 12.) B. ELECTRICAL CONNECTION 1. Be sure the power supply is disconnected before making electrical connections.
Lamp Replacement Remove the lamp and replace with an ordinary screw- base lamp bulb NOT MORE THAN 60 WATTS. Models JN334, JN335, JN634, To remove the lamp cover, if desired: JN635, JV324, JV334, JV335, ● Press the sides with 2 fingers until the side prongs JV624, JV634, JV635 have a are released.
Questions? Use This Problem Solver PROBLEM POSSIBLE CAUSE FAN DOES NOT ● A fuse may be blown or a circuit breaker tripped. Replace fuse or reset circuit breaker. OPERATE WHEN THE SWITCH IS ON FAN FAILS TO . Fan blade striking the hcmd sheI1. CIRCULATE AIR s Excessively soiled filter should be checked and corrected before using the hood again.
Help Us Help You... Write down the model and serial numbers. You’ll find them on a label on the back wall of the hood. These numbers are also on the Consumer Product Ownership Registration Card that came with your hood.
YOUR RANGE HOOD Staple sales slip or cancelled check WARRANTY here. Proof of original purchase date is needed to obtain service I — under warranty. WHAT IS COVERED FULL ONE-YEAR WARRANTY For one yea.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GE Ventila è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GE Ventila - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GE Ventila imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GE Ventila ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GE Ventila, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GE Ventila.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GE Ventila. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GE Ventila insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.