C US ® RT6621017r1 April 2010 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit.
PRODUCT IDENTIFICA TION 3 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN WA R N I N G T O PREVENT P OSSI BLE PERSONAL I NJURY OR DEATH DUE TO ASPHYX I ATI ON, THI S FURNACE M UST BE C AT E GOR Y I VENT ED. D O NOT VENT USI NG C ATEGORY III VEN TI NG. 1. Category I Venting is venting at a non-positive pressure.
5 PRODUCT DESIGN Accessibility Clearances (Minimum) Unobstructed front clearance of 24" for servicing is rec- ommended. SW B 1 0 36 11 * 24" clear ance f or s erviceab ility recom me nded. MINIM UM CLEARA NCE TO COMBUSTIBLE MATERIAL S - INCHES ** Si ngle Wall Vent (SW ) to be us ed only as a con ncetor.
COMPONENT IDENTIFICA TION 6 躀 Pressure Switch T ubul ar Heat E xchanger Flu e Pi pe C onnec ti o n Gas L i ne Entrance (Al tern at e) Indu ced Draf t Blowe r Gas Line En tr a nc e Gas V alve Roll o .
PRODUCT DIMENSIONS 7 AMH8 MO D EL S A B AMH 8 0 4 5 3 AX** AMH 8 0 7 0 3 AX** 14 1 2 - 1/ 2 AMH 8 0 7 0 4 BX** AMH 8 0 9 0 3 BX** AMH 8 0 9 0 4 BX** 17-1 / 2 16 A MH8 09 05C X * * A MH8 11 55C X * * 21 1 9 - 1/ 2 A MH8 140 5D X * * 24- 1 /2 23 A ll d i m e ns i o ns ar e i n in c h es .
8 PRODUCT DESIGN MODEL TRIP POINT ID BLOWER PRESSURE SWITCH ID BLOWER PRESSURE SWITCH PART # MODEL TRIP POINT ID BLOWER PRESSURE SWITCH ID BLOWER PRESSURE SWITCH PART # AMH80453A X** -0.60 B1370142 AMH80453A X** -0.60 B1370142 AMH80703A X** -0.60 B1370142 AMH80703A X** -0.
9 PRODUCT DESIGN Coil Matches: A large array of Amana ® brand coils are available for use with the AMH8 furnaces, in either upflow or horizontal applica- tions. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device).
10 PRODUCT DESIGN Thermost at s: The following Amana ® brand Thermostats are suggested for use with the AMH8 Furnace Models: Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards.
11 PRODUCT DESIGN T winComfort™ Configuration & Operation OFF ON Blower Switch to Hi Heat Operation Blower Switch to Hi Heat Operation T-Stat S atisfied T-Stat S atisfied Delay Time ( 5 Min) Del.
FURNACE SPECIFICA TIONS 12 NOTES: 1. For elevations above 2000 feet the rating should be reduced by 4% for each 1000 feet above sea level. The furnace must not be derated, orifice changes should only be made if necessary for altitude.
BLOWER PERFORMANCE SPECIFICA TIONS 13 NOTES: 1 . CFM in chart is without filters(s). Filters do not ship with this furnace, but must be provided by the installer. 2 . All furnaces ship as high speed cooling. Installer must adjust blower cooling speed as needed.
BLOWER PERFORMANCE SPECIFICA TIONS 14 30 40 50 60 70 80 90 1 10 12 0 100 13 0 140 150 100 90 80 70 60 50 40 30 20 10 OU TPUT B T U/HR x 10 00 BTU OUTPUT vs T EMPERA TURE RISE CHART TE M PE R AT U R E R ISE 600 CFM 700 900 100 0 1 100 1200 1400 1600 180 0 2000 2200 2400 CFM FORM ULA S BTU OUTPUT = C FM x 1.
15 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL TIPL E POW ER SOUR CES MA Y BE P RESENT .
16 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T A GE! DISCONNECT ALL POWER BEFORE SERVICI NG OR INST A LLING THIS UNIT . M UL TIPL E POW ER SOUR CES MA Y BE P RESENT .
17 SCHEMA TICS HI G H VO L T AG E! DISC ONNECT ALL POWER BEFORE SERVICI NG OR INST A LLIN G THIS UNIT . M UL TIPL E POW ER SOURCES M A Y BE PR ESENT . F AILURE T O DO SO MA Y CAUS E PROPERTY DAMAG E, PERSONAL I NJUR Y OR DEA TH . TYPICAL SCHEMATIC AMH8 ____** MODEL FURNACES WR 50M56-289 INTEGRATED IGNITION CONTROL .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Amana AMH* è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Amana AMH* - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Amana AMH* imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Amana AMH* ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Amana AMH*, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Amana AMH*.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Amana AMH*. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Amana AMH* insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.