Manuale d’uso / di manutenzione del prodotto FVR-C9S-2UX Drive Series del fabbricante GE
Vai alla pagina of 40
1 FVR-C9S-2UX Instruction Manual FVR-C9S-2UX Drive Series Three-phase 230 V AC Input T ype.
2 FVR-C9S-2UX CAUTION • Make sure that you r ead this instruction manual thoroughly before installing, wiring, operating and inspecting this drive. • Please make sure that this instruction manual accompanies the drive to the end user .
3 FVR-C9S-2UX Thank you for pur chasing the Fuji “FVR-C9S” drive, marketed by GE Fuji Drives USA, Inc. This instruction manual is included with the drive and equipment and is pr ovided for the convenience of the end user . Please be sure it accompanies the drive.
4 FVR-C9S-2UX 0. Safety Precautions Before carrying out installation, wiring, mainte- nance or inspection of the drive, read this in- struction manual thoroughly to gain a full under - standing of the correct operation pr ocedures. Make sure that you have r ead all product details, safety information, warnings and cautions before use.
5 FVR-C9S-2UX CAUTION: Do not touch the cooling fins, as they become hot during drive operation. Because it is relatively easy to set the drive to high speed operation, be sure to check the capacity of the motor and the equipment being operated before changing the drive function setting.
6 FVR-C9S-2UX UL/CSA W ARNING / A VERTISSEMENT Hazard of electrical shock. Disconnect incoming power before working on this contr ol. Risque de choc electrique. Couper l’alimentation avant le depannage de sette commande. More than one live cir cuit.
7 FVR-C9S-2UX 1. T ype 2. Phase: 3PH - thr ee-phase 3. V oltage range: 200V - 230V - AC200V Series 4. Frequency: 50/60Hz 5. Rated output capacity 6. Rated output curr ent 7. Output frequency range: 1- 120 Hz 8. Serial No. 2. Part Names 1. Drive Cover 2.
8 FVR-C9S-2UX Type (FVR _ _ _ C9S-2UX) F12 F25 F50 001 002 003 005 Applicable motor output 1 [Hp] 1/8 1/4 1/2 1 2 3 5 Rated capacity 2 [kVA] 0.28 0.56 1.0 1.6 2.8 4.0 6.6 Voltage [V] Three-phase 200-230V 50/60 Hz (Output voltage is proportional to input voltage) Output Rating Rated current [A] 0.
9 FVR-C9S-2UX Type (FVR _ _ _ C9S-2UX) F12 F25 F50 001 002 003 005 Applicable motor output 1 [Hp] 1/8 1/4 1/2 1 2 3 5 Frequency setting Key operation: Setting with UP/DOWN keys Potentiometer: Terminal for 1-5K ohm VR is provided Analog signal: 0-5 VDC 0-10 VDC (input resistance = 22k ohm) Display Run mode Output frequency is displayed.
10 FVR-C9S-2UX 5. External Dimensions 3.15 (80) 2.64 (67) 2 - 0.20 X 0.24 (2 - 5 X 6.2) 0.26 (6.5) .06 (1.5) 0.26 (6.5) 4.72 (120) 1.97 (50) 2.76 (70) DWG 1: FVRF12C9S-2UX to FVROO1C9S-2UX 0.20 (5) 0.39 (10) 4.33 (110) 3.94 (100) 0.20 (5) 0.39 (10) 2.
11 FVR-C9S-2UX 3.86 (98) 2 - dia. 0.20 (2 - dia. 5) 0.24 (6.2) 0.18 (4.5) 0.24 (6.2) DWG 2: FVR002C9S to FVR003C9S-2UX 0.24 (6) 0.45 (11.5) TERMINAL M3.5 D1 0.24 (6.2) 0.24 (6.2) D D2 0.24 (6.2) 4.65 (118) 4.21 (107) 4.33 (110) 5.12 (130) 0.20 (5) 1.97 (50) 3.
12 FVR-C9S-2UX 5.04 (128) 2 - dia. 0.20 (2 - dia. 5) 0.24 (6.2) 0.71 (18) 0.24 (6.2) FVR005C9S-2UX 0.24 (6.2) 0.45 (11.5) TERMINAL M4 3.37 (85.5) 0.24 (6.2) 0.24 (6.2) 5.45 (138.5) 2.87 (73) 0.24 (6.2) 5.61 (168) 5.18 (157) 5.51 (140) 7.09 (180) 0.20 (5) 2.
13 FVR-C9S-2UX 6. Installation Instructions Installation Conditions Install the drive in a location which meets the following requir ements: • The ambient temperature should be be- tween -10 ° C and +50 ° C. • The humidity should be between 20 and 90% RH.
14 FVR-C9S-2UX CN 1 8. 8. 8. Connect CN 2 CN 2 Guide Pin 1 2 Side view of inverter 4) Arrange the main cir cuit and the control circuit wiring as follows. 1. Motor coast-to-stop 2. Reset signal 3. Reverse-direction operation command 4. Forwar d-direction operation command 5.
15 FVR-C9S-2UX 1) Keypad Panel Operation From the factory , the drive is set for fr equency control by means of the potentiometer contr ol knob on the keypad panel. The RUN/STOP function of the drive is contr olled by the RUN/ STOP keys on the keypad panel.
16 FVR-C9S-2UX 2) External Signal Operation Ensure that the connection is as shown below when operating the drive by means of an exter - nal frequency setting potentiometer or contact signal.
17 FVR-C9S-2UX Applicable motor output [Hp] 1/8 1/4 1/2 1235 Drive type FVRF12 FVRF25 FVRF50 FVRF001 FVRF002 FVRF003 FVRF005 C9S-2UX C9S-2UX C9S-2UX C9S-2UX C9S-2UX C9S-2UX C9S-2UX Output rated capacity [kVA] 0.
18 FVR-C9S-2UX Terminal Function Explanation Classi- fication Terminal Code Terminal Name Explanation of Function Main Circuit L1, L2, L3 Commercial power supply input terminals For connection of 3-Ph.
19 FVR-C9S-2UX Terminal Function Explanation Classi- fication Terminal Code Terminal Name Explanation of Function Output for Motor FM Analog Monitor Outputs + 10VDC between FM and CM terminals. When frquency setting is equal to the maximum frequency setting, outputs + 10VDC at 150% current when monitoring output current.
20 FVR-C9S-2UX RUN STOP T ime Frequency Forward Reverse FWD-CM REV-CM ON ON Frequency 11. Operation Pre-Operation Inspection • Check for wiring errors. • Check that all loose wire stands, metal chips and unnecessary scr ews, etc. have been removed.
21 FVR-C9S-2UX Selecting Operation Method With the FVR-C9S Series, the following methods can be selected to input the RUN/STOP signals and for fr equency setting.
22 FVR-C9S-2UX 12. Keypad Panel Part Names and Functions Digital monitor: In program mode, the key- pad displays the various function codes and data values. During operation, it displays the output fre- quency , curr ent, voltage, etc. If a fault occurs, the causes of the problem will be dis- played as a code.
23 FVR-C9S-2UX 4) Function setting method Method Operation Procedure Display 1 PRG/RESET Press this key to switch to the program setting mode. 60 . 0 F0 0 2 UP/DOWN Press UP key or DOWN key to select function code F0 1 3 FUNC/DATA Press this key to display function code.
24 FVR-C9S-2UX Function Code Tables Function Code Function Date Code Range Unit Min. Set. Factory Setting Change During Operation F00 Data protection 0: Data change possible 1: Data change not possibl.
25 FVR-C9S-2UX Function Code Tables Function Code Function Date Code Range Unit Min. Set. Factory Setting Change During Operation F15 Motor Running Sound 0 - 5 (code) — — 5 Yes F16 Fault Memory Th.
26 FVR-C9S-2UX F 0 0 Data Protection The set data can be locked so that it will not be changed by mistake. 0 Data change possible 1 Data change not possible To change data simultaneously press the STOP key and either the UP/DOWN key. F 0 1 Frequency Command Either of the following two frequency setting methods can be selected.
27 FVR-C9S-2UX F 0 7 Torque Boost Can be set from among 32 different levels in accordance with the type of load, the characteristics of the motor, etc. 0 1 2 Low 3 1 High 8 Set to match this when using a Fuji FV motor designed for use with a drive. F 0 8 Electronic Thermal Overload Relay Either of the following two can be selected.
28 FVR-C9S-2UX Derating characteristics for the continuously allowable current 1) For a standard 4-pole motor _ _ 1 2) for a forced-air cooled motor _ _ 2 110 - 100 - 90 - 80 - 70 - 60 - 50 - 40 - 30 .
29 FVR-C9S-2UX F 1 0 Restart After Momentary Power Failure It is possible to select whether or not to restart operation when power supply is resumed after momentary power failure. 0 Inactive While stopped: Stopped condition is maintained even after power supply has been restored.
30 FVR-C9S-2UX F 1 4 Starting Frequency The starting frequency can be set in increments of 1 Hz within a range of 1 to 6 Hz. Note that stopping will also occur at the frequency set by this function. 1 1 Hz 6 6 Hz Set to 2 Hz when using a high speed motor.
31 FVR-C9S-2UX F 1 7 Data Initialization Reset the data for all of the functions to the value set at the factory. 0 Inactive 1 Resets to the value set at the factory. From the _ _ 0 display, by simultaneously pressing STOP and UP, the display will change to _ _ 1.
32 FVR-C9S-2UX F 2 4 High Limiter F 2 5 Low Limiter The upper and lower and lower limits of the output frequency can be set. 0 Set as a percentage of the maximum frequency in increments of 1% within a.
33 FVR-C9S-2UX F 2 9 Multistep Speed Setting 1 (Speed 1) F 3 0 Multistep Speed Setting 2 (Speed 2) F 3 1 Multistep Speed Setting 3 (Speed 3) Multistep speeds can be set within a range of 0 to 120 Hz only by changing the contact signal from outside. (X1-CM X2-CM).
34 FVR-C9S-2UX F 3 2 FM Terminal Output Level Calibration Adjust the level of the voltage output to terminal FM for the frequency meter. 0 Approximate DC 6.5V at full scale 99 Approximate DC 10.3V at full scale Note: The FM terminal output is a pulse output of which frequency is constant (38.
35 FVR-C9S-2UX Function Explanation Display Alarm Output Momentary Overcurrent Protection OC1 OC2 OC3 Yes Overvoltage Protection Detects overvoltage of DC intermediate circuit and stops drive. OU Yes Undervoltage Protection Detects undervoltage of DC intermediate circuit and stops drive.
36 FVR-C9S-2UX 15. W arranty Parts and Service The purpose of the following section to provide specific instructions to the user of the FVR-C9S-7UX drive r egarding warranty administration and how to obtain assistance on both in-warranty and out-of-warranty equipment.
37 FVR-C9S-2UX In-Warranty Failure Checklist To assist with warranty troubleshooting, the following information is required. This data is needed to evaluate the cause in an effort to eliminate any further failures.
38 FVR-C9S-2UX Notes:.
39 FVR-C9S-2UX Notes:.
40 FVR-C9S-2UX INR-Si47-0461 b-E Printed in Japan GE Fuji Drives USA, Inc. 1501 Roanoke Blvd. Suite 435 Salem, V A 24153 1-800-543-6196 Internet Address: http://www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GE FVR-C9S-2UX Drive Series è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GE FVR-C9S-2UX Drive Series - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GE FVR-C9S-2UX Drive Series imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GE FVR-C9S-2UX Drive Series ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GE FVR-C9S-2UX Drive Series, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GE FVR-C9S-2UX Drive Series.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GE FVR-C9S-2UX Drive Series. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GE FVR-C9S-2UX Drive Series insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.