49-7419-1 11-01 JR Air Con di t i o n ers Safety Instr uctions . . . . . . . . . . .2 Operating Instr uctions Controls—Dip Switches . . . . . .3–5 Controls—T erminal Connections . . . . . . . . . . . . . .6, 7 On/Off Switch . . . . . . . . . . .
Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING.
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 3 Controls–dip switches. GEAppliances.com The dip switch controls are located behind the front case panel, through an opening on the front of the unit.
Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 4 Controls–dip switches. Freeze Sentinel (Requires room air sensor kit–RA VRMS) When this switch is enabled (UP) , it turns OFF the freeze sentinel protection feature.
5 Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support GEAppliances.com T emperature Limiting (Requires room air sensor kit–RA VRMS) T emperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating.
6 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Controls—terminal connections. Controls–T erminal Connections The terminal connections are located behind the front case panel through an opening on the front of the unit.
Remote Thermostat The unit will be controlled by a remote thermostat. IMPORT ANT : The Zoneline thermostat connections provide 24V AC only . If using a digital/electronic wall thermostat, you must set it to the 24V AC setting. See the Installation Instructions for the wall thermostat.
8 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Other features of your Zoneline. About Heat Pumps (on some models) Heat pumps can reduce operating costs by exchanging heat from the outside air—even when the outside temperature is below freezing— and releasing that heat indoors.
Indoor/Outdoor Coils The exhaust coils on the Zoneline should be checked regularly . If they are clogged with dirt or soot, they may be professionally steam cleaned by your GE service center . Y ou will need to remove the unit from the case to inspect the coils because the dirt build-up occurs on the exhaust side.
BEFORE YOU BEGIN Installation Zoneline Air Instructions Conditioners Read these instr uctions completely and carefully . • IMPORT ANT – Save these instructions for local inspector’ s use. • IMPORT ANT – Obser ve all governing codes and ordinances.
11 Installation Instructions ELECTRICAL REQUIREMENTS 230/208 VOL T ELECTRICAL SUPPL Y T andem 15 Amp 230/208 volt receptacle configuration Perpendicular 20 Amp Large T andem 30 Amp • Use ONLY the wiring size recommended for single outlet branch circuit.
REMOVE JUNCTION BOX COVER • Remove the junction box cover by taking out the front two screws. 1 Junction box Installation Instructions 12 DIRECT CONNECT APPLICA TIONS W ARNING: FOR 265 VOL T DIRECT .
13 Installation Instructions DIRECT CONNECT APPLICA TIONS MAKE WIRE LEAD CONNECTIONS INSIDE THE JUNCTION BOX 1. Make all wire connections by using appropriate UL-listed electrical connectors and techniques. 2. Be sure that all wire leads are inside the junction box and not pinched between the box and the unit.
Installation Instructions 14 ZONELINE COMPONENTS Case Zoneline unit Front Case Panel REQUIRED ACCESSORIES (Check the “Essential Elements” label on the unit.
Installation Instructions 15 TYPICAL UTILITY CLOSET AND DIMENSIONS (FOR REFERENCE ONL Y).
Installation Instructions 16 UTILITY CLOSET CONNECTION LOCA TIONS IMPOR T ANT : Plan and locate plenum, wall plug, drain and thermostat carefully to avoid interference.
Installation Instructions 17 RETURN AIR GRILLE INST ALLA TION OPTIONS The room return air grille may be installed toward the front or either side of the unit. Improper return air arrangements will cause per formance problems. There are three indoor Return Air Grille Installation options.
BUILD AND INST ALL THE ZONELINE BASE PLA TFORM 1. Construct a 23 1 ⁄ 4 ″ min. x 23 1 ⁄ 4 ″ min. square platform. NOTE: The platform must have a load-bearing capacity of 175 lbs.
INST ALL THE DRAIN An exter nal or an inter nal drain must be attached to the drain connector . Exter nal Drain Attach a 90° PVC elbow to the unit’ s female 3/4 ″ NPT drain connector . Use the other end of the elbow to run a 3/4 ″ Sch.40 PVC pipe through the knockout holes of both the wall plenum and the architectural louver to the outside.
INST ALL AND CONNECT THE CASE 1. Remove the front case panel and pull the unit out of the case. Place the empty case onto the platform in the closet with the outdoor side facing the wall plenum opening. Align the case to the plenum opening and attach with six screws.
.
Installation Instructions SER VICING W ARNING: Before servicing, switch power off at the ser vice panel and lock the area to prevent power from being switched on accidentally . When the area cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support Before Y ou Call For Service… GEAppliances.com T roubleshooting T ips Problem Possible Causes What T o Do Zoneline does The unit is • Make sure the Zoneline plug is pushed completely not start unplugged.
Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 24 Normal Operating Sounds Y ou may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high.
25 General Electric Company W ar ranty Registration Depar tment P .O. Box 32150 Louisville, KY 40232-2150 Please place in envelope and mail to: ✁ Cut here.
26 Consumer Pr oduct Ownership Registration Important Mail T oday! General Electric Company Louisville, Kentucky GEAppliances.com First Name Mr . ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Y ear Zip Code Apt.
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support 27 V ertical Zoneline W arranty . For The Period Of: GE Will Replace: One Y ear Any part of the Zoneline which fails due to a defect in materials or workmanship.
Printed in China Consumer Support. GE Appliances W ebsite GEAppliances.com Have a question or need assistance with your appliance? T r y the GE Appliances W ebsite 24 hours a day , any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il GE 7500 SERIES è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del GE 7500 SERIES - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso GE 7500 SERIES imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul GE 7500 SERIES ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il GE 7500 SERIES, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del GE 7500 SERIES.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il GE 7500 SERIES. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo GE 7500 SERIES insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.