Combitherm ® Combination Ov en / Steamer E S GAS COM B IT OUCH ® S ERI ES 6•10 ES G 10•10 ES G 7•14 ES G 10•20 ES G 12•18 ES G 20•20 ES G • I N ST ALLA T I O N W164 N9221 W ater Street • P .O. Box 450 • Menomonee Falls, W isconsin 53052-0450 USA PHONE: 262.
i Delivery .......................................................................... 1 Unpacking ..................................................................... 1 Safety Procedur es and Precautions .............................. 2 Installation Installation Codes and Standards .
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 1. THE INFORMATION CONTAINED IN THIS MANUAL IS IMPORTANT FOR THE PROPER INSTALLATION OF THIS OVEN. PLEASE READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE. IMPROPER CONNECTION OF THIS APPLIANCE WILL NULLIFY ALL WARRANTIES.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 2. CAUTION Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 3. INSTALLATION SITE INSTALLATION INSTALLATION CODES & STANDARDS The following codes and standards ar e required for installation of this oven: AIR SUPPL Y , ELECTRICAL CONNECTIONS, W A TER CONNECTIONS, AND W ASTE W A TER DISCHARGE.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 4. INSTALLATION SITE INSTALLATION NOTE: Note dimensions required for doorways and aisles for access of the oven and pallet to the installation site. Transport the oven in an upright and level position only.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 5. INSTALLATION SITE INSTALLATION POSITIONING REQUIREMENTS q In order to ensure proper ventilation, a minimum distance of at least 6-inches (152mm) must be kept from the control panels side (left) of the oven and any adjoining surfaces.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 6. SITE INSTALLATION Lifting Ins tructions Do not lift in this area! Damage t o the components will r esult. Cent er of Gra vity Front View T op View (Fron t) Leg 24” Spacer Board Remov e banding befor e lift ing.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 7. INSTALLATION COMMON SPECIFICATIONS q CombiGuard™ BWS Blended W ater System FI-28727 (INCLUDES 50 GALLON T ANK, 1 MEMBRANE &.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 8. 6 • 10 ES G B C D 2-15/16" (74mm) 2" (50mm) 47-5/16" (1201mm) 42-1/16" (1068mm) 40-1/8" (1018mm) 3.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 9. 10 • 10 ES G 21-11/16" (550mm) 5-3/16" (131mm) 42-1/16" (1068mm) 40-1/8" (1018mm) 37" (939mm) 34-5.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 10. 7 • 14 ES G D A B Water Drain (Bottom) (650mm) 8-1/2" (216mm) 25-5/8" 42" (1066mm) 5-1/8" (130mm) 31-3.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 11. 10 • 20 ES G 45-3/16" (1148mm) 42-7/16" (1077mm) 22-11/16" (575mm) 12-13/16" (325mm) Water Drain (Bott.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 12. 12 • 18 ES G 25-5/8" (650mm) 33-1/8" (840mm) 45-3/16" (1148mm) 42-7/16" (1077mm) 22-11/16" (575mm.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 13. 20 • 20 ES G [A,B] 4-3/8" (110mm) [D] 4-9/16" (116mm) [C] 3-9/16" (89mm) Water Drain (Side Back) [D] 4-5/8&.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 14. INSTALLATION ELECTRICAL An electrical wiring diagram is located behind the control panel on the left side of the oven. This appliance must be branch circuit pr otected with proper ampacities, in accordance with the wiring diagram.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 15. INSTALLATION MOBILE EQUIPMENT RESTRAINT The gas Combitherm must use a connector that complies with The Standard for Connectors for Movable Gas Appliances , ANSI Z21.69 CSA 6.16 and addenda Z21.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 16. INSTALLATION VENTILATION REQUIREMENTS An adequate ventilation system is requir ed for commercial cooking equipment. Information may be obtained by writing to the National Fire Pr otection Association, Batterymarch Park, Quincy , MA 02269.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 17. INSTALLATION GAS SUPPLY & INSTALLATION The Alto-Shaam gas Combitherm has been set to operate with either natural gas or propane as indicated on the identification name plate.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 18. INSTALLATION GAS SUPPLY & INSTALLATION Remove any tape or compound residue on all external thread connections before proceeding.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 19. INSTALLATION GAS SUPPLY & INSTALLATION The minimum size requir ement for gas piping or a flexible connector is 3/4 - inch (19mm). For long runs of gas piping, the pipe diameter must conform to the tables in the National Fuel Gas Code, ANSI/NFP A Z223.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 20. INSTALLATION GAS SUPPLY & INSTALLATION LEAk TESTING If a pressure leak test above 1/ 2 psi is to be performed on the bui.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 21. INSTALLATION WATER SUPPLY & INSTALLATION WARNING TO PREVENT WATER PIPES FROM BURSTING, INCOMING WATER SUPPLY SHOULD BE TURNED OFF WHEN THE APPLIANCE IS NOT IN USE. WARNING WATER SUPPLY MUST BE OPEN WHEN CLEANING PROGRAM IS ACTIVATED.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 22. INSTALLATION WATER SUPPLY & INSTALLATION WATER REQUIREMENTS WATER QUALITY MINIMUM STANDARDS TWO (2) COLD W A TER INLETS - DRINKING QUALITY ONE (1) TREA TED W A TER INLET : 3/4" NPT* ONE (1) UNTREA TED W A TER INLET : 3/4" NPT* LINE PRESSURE: 30 to 90 psi 2.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 23. INSTALLATION WATER VALVE WATER DRAINAGE s h u t - o f f v a l v e s h o w n i n t h e o f f p o s i t i o n NOTE: THE SHUT-OFF VALVE MUST BE IN THE OPEN POSITION WHEN THE OVEN IS BEING USED.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 24. Stand Pipe, 1-1/2" NPT (38mm) diameter T o Dr ain - Floor Sink - Air Gap to be within the first 12" (305mm) of the.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 25. INSTALLATION GREASE COLLECTION HOOK-UP ( i f eQuippeD w i t h t h i s featuRe ) • Grease Collection Hose Assembly is attached to the oven in the back. • Place Grease Collection Containers inside the tray of the Mobile Grease Collection Cart.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 26. COMBITOUCH® CHECKLIST Use this list as a final check of oven installation conformance. Damage directly attributed to improper set up, installation, or cleaning can invalidate warranty claims.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 27. INSTALLATION This section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unauthorized service personnel.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 28. INSTALLATION Error Code Error Call Out in Display Description of Error Possible Cause E13 Boiler Temperature High Boiler temperature overheats — Scale build up inside steam generator.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 29. INSTALLATION ERROR CODES Error Code Error Call Out in Display Description of Error Possible Cause E34 Steam Generator Drain Pump Fault Water level in steam generator does not drop during cleaning program — Scale build up inside the steam generator drain pump.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 30. see m o to r c o n t r o l e r r o r c h a rt o n n e x t pag e INSTALLATION ERROR CODES Error Code Error Call Out in Display Description of Error Possible Cause E57 No Rinse Water During rinse no water fl ow is detected through solenoid valve — Water supply is shut off.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 31. INSTALLATION Type of Error Indication Release of Error Undervoltage LED fl ashing sequence, with 1 fl ash per period. Voltage of intermediate circuit is less than 250V Overvoltage LED fl ashing sequence, with 2 fl ashes per period.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 32. INSTALLATION ERROR CODES When the oven malfunctions, an error code will appear in the display . PRESS THE ST AR T ICON TO ACKNOWLEDGE THE ERROR. The icons that begin to flash repr esent operational modes that are still usable.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 33. ORIGINAL EQUIPMENT LIMITED WARRANTY Alto-Shaam, Inc. warrants to the original purchaser that any original part that is found.
COMBITOUCH ® ESG SERIES • GAS INST ALLA TION MANUAL • MN-29246 • 34. W164 N9221 W ater Street • P .O. Box 450 • Menomonee Falls , W isconsin 53052-0450 • U.S.A. PHONE: 262.251.3800 • 800.558-8744 USA/CANADA F AX: 262.251.7067 • 800.329.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Alto-Shaam 610ESG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Alto-Shaam 610ESG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Alto-Shaam 610ESG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Alto-Shaam 610ESG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Alto-Shaam 610ESG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Alto-Shaam 610ESG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Alto-Shaam 610ESG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Alto-Shaam 610ESG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.