Manuale d’uso / di manutenzione del prodotto 1010ESG del fabbricante Alto-Shaam
Vai alla pagina of 33
Combitherm ® Combination Ov en / Steamer E S GAS COM B IT OUCH ™ S ERI ES 6•10 ES G 10•10 ES G 7•14 ES G 10•20 ES G 12•18 ES G 20•20 ES G • I N ST ALLA T I O N W164 N9221 W ater Street • P .O. Box 450 • Menomonee Falls, W isconsin 53052-0450 USA PHONE: 262.
i Delivery .......................................................................... 1 Unpacking ..................................................................... 1 Safety Procedur es and Precautions .............................. 2 Installation Installation Codes and Standards .
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 1. THE INFORMATION CONTAINED IN THIS MANUAL IS IMPORTANT FOR THE PROPER INSTALLATION OF THIS OVEN. PLEASE READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE. IMPROPER CONNECTION OF THIS APPLIANCE WILL NULLIFY ALL WARRANTIES.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 2. CAUTION Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 3. INSTALLATION SITE INSTALLATION INSTALLATION CODES & STANDARDS The following codes and standards ar e required for installation of this oven: AIR SUPPL Y , ELECTRICAL CONNECTIONS, W A TER CONNECTIONS, AND W ASTE W A TER DISCHARGE.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 4. MINIMUM CLEARANCE REQUIREMENTS LEFT SIDE 6” (152mm) MINIMUM 18” (457mm) SERVICE ACCESS RECOMMENDED 20” (508mm) FROM HEAT PRODUCING E.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 5. INSTALLATION SITE INSTALLATION POSITIONING REQUIREMENTS q In order to ensur e proper ventilation, a minimum distance of at least 6-inches (152mm) must be kept from the contr ol panels side (left) of the oven and any adjoining surfaces.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 6. INSTALLATION COMMON SPECIFICATIONS q CombiGuard™ BWS Blended W ater System FI-28727 (INCLUDES 50 GALLON T ANK, 1 MEMBRANE & 3 FIL TE.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 7. 6 • 10 ES G B C D 2-15/16" (74mm) 2" (50mm) 47-5/16" (1201mm) 42-1/16" (1068mm) 40-1/8" (1018mm) 37" (939m.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 8. 10 • 10 ES G 21-11/16" (550mm) 5-3/16" (131mm) 42-1/16" (1068mm) 40-1/8" (1018mm) 37" (939mm) 34-5/16" (87.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 9. 7 • 14 ES G D A B Water Drain (Bottom) (650mm) 8-1/2" (216mm) 42" (1066mm) 5-1/8" (130mm) 31-3/4" (805mm) 33-1/8&quo.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 10. 10 • 20 ES G 45-3/16" (1148mm) 42-7/16" (1077mm) 22-11/16" (575mm) 12-13/16" (325mm) Water Drain (Bottom) 2-3/16&qu.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 11. 12 • 18 ES G 25-5/8" (650mm) 33-1/8" (840mm) 45-3/16" (1148mm) 42-7/16" (1077mm) 22-11/16" (575mm) 12-13/16&qu.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 12. 20 • 20 ES G [A,B] 4-3/8" (110mm) [D] 4-9/16" (116mm) [C] 3-9/16" (89mm) Water Drain (Side Back) [D] 4-5/8" (116mm).
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 13. INSTALLATION ELECTRICAL An electrical wiring diagram is located behind the control panel on the left side of the oven. This appliance must be branch circuit pr otected with proper ampacities, in accordance with the wiring diagram.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 14. INSTALLATION MOBILE EQUIPMENT RESTRAINT The gas Combitherm must use a connector that complies with The Standard for Connectors for Movable Gas Appliances , ANSI Z21.69 CSA 6.16 and addenda Z21.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 15. INSTALLATION VENTILATION REQUIREMENTS An adequate ventilation system is requir ed for commercial cooking equipment. Information may be obtained by writing to the National Fire Pr otection Association, Batterymarch Park, Quincy , MA 02269.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 16. INSTALLATION GAS SUPPLY & INSTALLATION The Alto-Shaam gas Combitherm has been set to operate with either natural gas or propane as indicated on the identification name plate. Make certain the gas supply matches the nameplate information.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 17. INSTALLATION GAS SUPPLY & INSTALLATION Remove any tape or compound residue on all external thread connections before proceeding.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 18. INSTALLATION GAS SUPPLY & INSTALLATION The minimum size requir ement for gas piping or a flexible connector is 3/4 - inch (19mm). For long runs of gas piping, the pipe diameter must conform to the tables in the National Fuel Gas Code, ANSI/NFP A Z223.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 19. INSTALLATION GAS SUPPLY & INSTALLATION LEAK TESTING If a pressure leak test above 1/ 2 psi is to be performed on the building supply .
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 20. INSTALLATION WATER SUPPLY & INSTALLATION WARNING T O PREVENT W A TER PIPES OR HOSES FROM B URSTING, INCOMING W A TER SUPPL Y SHOULD BE TURNED OFF WHEN THE APPLIANCE IS NOT IN USE. WARNING W A TER SUPPL Y MUST BE OPEN WHEN CLEANING PROGRAM IS A CTIV A TED.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 21. INSTALLATION WATER SUPPLY & INSTALLATION WATER REQUIREMENTS TWO (2) COLD WATER INLETS - DRINKING QUALITY ONE (1) TREATED WATER INLET: 3/4” NPT* ONE (1) UNTREATED WATER INLET: 3/4” NPT* LINE PRESSURE: 30 to 90 psi 2.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 22. INSTALLATION 1-1/2” (41mm) diameter connection requir ed Condensate Pan Clean Out The oven must discharge thr ough an indirect waste pipe by means of an air gap. The drain fitting is supplied with a 1-1/2-inch (41mm) NPT thread.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 23. COMBITOUCH™ CHECKLIST Use this list as a final check of oven installation conformance. Damage directly attributed to improper set up, installation, or cleaning can invalidate warranty claims.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 24. INSTALLATION CombiTouch ERROR CODES This section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unauthorized service personnel.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 25. INSTALLATION CombiTouch ERROR CODES Error Code Error call out in Display Description of Error Possible reason E13 Boiler T emperature High Boiler temperature overheats — Scale build up inside steam generator.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 26. INSTALLATION CombiTouch ERROR CODES Error Code Error call out in Display Description of Error Possible reason E34 Steam Generator Drain Pump Fault W ater level in steam generator does not drop during cleaning program — Scale build up inside the steam generator drain pump.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 27. see motor control error char t o n next p a g e INSTALLATION CombiTouch ERROR CODES Error Code Error call out in Display Description of Error Possible reason E57 No rinse water During rinse no water fl ow is detected through solenoid valve — Water supply is shut off.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 28. INSTALLATION Type of Error Indication Release of Error Undervoltage LED fl ashing sequence, with 1 fl ash per period. Voltage of intermediate circuit is less than 250V Overvoltage LED fl ashing sequence, with 2 fl ashes per period.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 29. INSTALLATION ERROR CODES When the oven malfunctions, an error code will appear in the display . PRESS THE ST AR T ICON TO ACKNOWLEDGE THE ERROR. The icons that begin to flash repr esent operational modes that are still usable.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 30. ORIGINAL EQUIPMENT LIMITED WARRANTY Alto-Shaam, Inc. warrants to the original purchaser that any original part that is found to be defective in material or workmanship will, at Alto-Shaam’s option, subject to provisions hereinafter stated, be replaced with a new or rebuilt part.
COMBITOUCH TM ESG SERIES • GAS INST ALLA TION MANUAL • 31. W164 N9221 W ater Street • P .O. Box 450 • Menomonee Falls , Wisconsin 53052-0450 • U.S.A. PHONE: 262.251.3800 • 800.558-8744 USA/CANADA F AX: 262.251.7067 • 800.329.8744 U.S.A. ONL Y www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Alto-Shaam 1010ESG è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Alto-Shaam 1010ESG - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Alto-Shaam 1010ESG imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Alto-Shaam 1010ESG ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Alto-Shaam 1010ESG, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Alto-Shaam 1010ESG.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Alto-Shaam 1010ESG. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Alto-Shaam 1010ESG insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.