Manuale d’uso / di manutenzione del prodotto PRIMERGY RX200 S6 del fabbricante Fujitsu
Vai alla pagina of 28
PRIMERGY RX2 00 S6 System configurator and order-information guid e Contents 4x or 6x 2.5" Hot-plu g HDD or SSD 8x 2.5" Hot-plug HDD or SDD Instruc tions Configuration diagram Configurator 0 System softw are I Basic unit II Processor III Memory IV Graphics V Accessible drives G-VI Drive Bay for 6x 2.
System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Instructions This document c ontains basic product and configuration information that will enable you to configure your system via PC-/SystemArchit ect.
System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Configuration diagra m PRIMERGY RX200 S6 Sy st em unit (I) board front side Memory CPU1 right side (Channe l A + B + C) A cc essible drives (V) Bank 1 (3 Modules) Bay for 5,25"x 0,5" SATA-DVD Bank 2 (3 Modules) Only with option 6x 2.
PRIMERGY - Softw are Co nfigurato rs and Release Lists Start PRIMERGY RX 200 S6 PRIMERGY RX200 S6 S tatus 201 1-10-30 SW Configurator 32 bit with OEM -Software without OEM-Softw are for PRIMERGY Serve.
PRIMERGY-Softwa re Configur ators and Release Lists Start PRIME RGY RX2 00S6 PRIMERGY RX 200 S6 Status 2011-1 0-30 SW Con figurator 64 bit (EM64T / IA6 4) w ith OEM-Softw are w ithout OEM-Softw are fo.
System c onfigurator and order-inf ormation guide Start PRIMERGY RX200 S6 PRIMERGY RX200 S6 Status 2011-10-30 Section I Basic u n it System u nit con sistin g of: * 1U Hou sin g in clu din g - power cord rack 4m len gth (PSU has to b e config ured min 1x) * Fan s - Redun dant a nd ho t plug system fans ( 6x ) * Drive s / Bays - 6x 2.
System c onfigurator and order-inf ormation guide A PRIMERGY RX200 S6 Status 2011-10-30 In terfac es at th e re ar: * 1x RS-232-C (seria l, 9 pi ns) (usable for BMC or OS or sha red) * 1x VGA (15 pin s): If Front-VGA is used , then Rear-VGA is disabl ed * 3x USB 2.
System c onfigurator and order-inf ormation guide B PRIMERGY RX200 S6 Status 2011-10-30 Rack v ersi on for 19'' rac ks w ith NO PSU incl ude d in Base Un it No Rack-mo un tin g kit i ncl ude.
System c onfigurator and order-inf ormation guide C PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F2735 -E101 S26361 -F2735 -E110 S26361 -F2735 -E111 S26361 -F2735 -E140 RMK-F1_1-2U Server RMK-P_1-2U Se.
System c onfigurator and order-inf ormation guide D PRIMERGY RX200 S6 Status 2011-10-30 Section II Processor There a re 2 pro cessor sockets available.
System c onfigurator and order-inf ormation guide E PRIMERGY RX200 S6 Status 2011-10-30 Section III Memory - There a re 6 me mory slots for m ax. 9 6GB registere d (reg) DDR3 RA M per CPU av aila ble w ith 1 6GB RDIMMs or max. 12GB u nbu ffere d (ub ) DDR3 RA M per CPU av aila ble w ith 2GB UDIMMs => max.
System c onfigurator and order-inf ormation guide F PRIMERGY RX200 S6 Status 2011-10-30 For a des cription of me mory con figu ration s refer to section "Mem ory Configu ration s" Minimum one memory modu le or memory order code per CPU = first memory Registered (reg) RDIMMs (1.
System c onfigurator and order-inf ormation guide F1 F2 PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F3284 -E1 S26361 -F3284 -E2 Spare Ch an ne l Mode I n stallati on Performan ce Mode In sta llation W.
System c onfigurator and order-inf ormation guide G1 G2 PRIMERGY RX200 S6 Status 2011-10-30 S26361 -F3284 -E3 Mirrored Cha nn el Mode In sta llation W ith thi s order code a BI OS setup for Mirrored C.
System c onfigurator and order-inf ormation guide PRIMERGY RX200 S6 Status 2011-10-30 Section IV Graphic s Graphics Control ler in tegrate d in i RMC S2 (integ rated Re mote Manag ement Con troller): .
System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 Memory Configuration PRIMERGY RX200 S6 Each CPU of fers 6 Slots fo r DDR3 Memo ry Modules organised in 2 Ba nks and 3 Channe ls. If you need m ore than 6 Slots you ha ve to configu re the 2n d CPU.
System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 Used CPU Dual-Core CPU with max. 800MHz DDR3 spee d (4.8GT/s) Xeon E5503 2C/2.00 GHz/2M/4,80GT/s (80W ) Quad-Core CPU`s with max. 800MHz DDR3 spee d (4.8GT/s) Xeon E5506 4C/2.
System co nfigurato r and orde r-informa tion guide PRIMERGY RX 200 S6 Stat us 2011 -10-30 1. Independent Channel Mode required required if 2 nd CPU is config ured Bank I Data Data Data Data Data Data.
System c onfigurator and order-inf ormation guide I PRIMERGY RX200 S6 Status 2011-10-30 Section V Accessible drives Setup RX200 S6 by ServerStart is supporte d with foll owing confi gurati ons: no Flo.
System configurator and order-infor mation guide J PRIMERGY RX 200 S6 Status 2011-1 0-30 Section G-VI Drive Bay for 6x / 8x 2.5" HD Ba sic Unit Base Unit S2636 1-K134 2-V10 1 Drive Bay w ith u p to 6x 2.5" HDDs plu s on e ba y for DVD On ly 4 HDD Po rts are conn ected to a RAID Con t roll er.
System configurator and order-infor mation guide J1 PRIMERGY RX 200 S6 Status 2011-1 0-30 J2 Section G-VIII 4x / 6x / 8x 2 .5" SA S / SAT A Ha rd disk drive s Section G- IX 4x 2.5" S ATA Ha rd disk drives For basic u n its V1x x u p to 6x SA TA / SAS 2.
System configurator and order-infor mation guide L PRIMERGY RX 200 S6 Status 2011-1 0-30 Section X External SA S Dis k Array , SAS back up drives or SCSI periphe ral device s External 8-po rt SAS-co n.
System configurator and order-infor mation guide M PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XI Fibre Chan nel Fibre Chan nel Controller for externa l storage sy stems S263 61-F33 06-E2 01 S263 61.
System configurator an d order-information gu ide N PRIMERGY RX 200 S6 Statu s 2011-10-30 Section XII Communicat ion / Network 2x 1GBit on-b oard LAN Cont roller Teaming: Failov er, Load Balancing Gig.
System configurator an d order-information gu ide N1 PRIMERGY RX 200 S6 Statu s 2011-10-30 F) InfiniBan d HCA's S26361-F4475-E102 S26361-F4475-L102 IB HCA 40Gb 1 port QDR for loo se deli very IB HCA 1x 40Gb PCIe 2.
System configurator and order-infor mation guide O PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XIII System Mana gemen t Products (Re moteView) S263 61-F17 90-E2 41 iRM C S2 (in t egrated Remote M an.
System configurator and order-infor mation guide P PRIMERGY RX 200 S6 Status 2011-1 0-30 Section XVI Energy Star S263 61-F33 01-E4 01 RX200 S6 E-Star Fa m1 Limits con figu ration in accorda n ce wi th E ne rgy Star requ iremen ts max.
System configurator and order-infor mation guide PRIMERGY RX 200 S6 Status 2011-1 0-30 Change Report Date Order number Changes 2011-1 0-30 S26361 -F4541-Ex00 new SAS SSD with 100 , 200, 400 GB add ed .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Fujitsu PRIMERGY RX200 S6 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Fujitsu PRIMERGY RX200 S6 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Fujitsu PRIMERGY RX200 S6 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Fujitsu PRIMERGY RX200 S6 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Fujitsu PRIMERGY RX200 S6, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Fujitsu PRIMERGY RX200 S6.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Fujitsu PRIMERGY RX200 S6. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Fujitsu PRIMERGY RX200 S6 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.