DS04-27801-1E FUJITSU SEMICONDUCT OR DA T A S H E E T ASSP F or P o wer Management Applications (Mobile Phones) P o wer Mana g ement IC f or GSM Mobile Phone MB3891 ■ ■ ■ ■ DESCRIPTION MB3891 is intended to be used in future GSM-phones, Dual Band phones and Dual Mode phones .
MB3891 2 ■ ■ ■ ■ PIN ASSIGNMENT (TOP VIEW) (FPT-64P-M03) N.C. : 49 N.C. : 50 SW2-OUTPUT : 51 SW2-INPUT : 52 SW1-ON : 53 SW2-ON : 54 SW3-ON : 55 CONT3 : 56 CONT5 : 57 OUT5 : 58 GND5 : 59 VBAT3 : 60 VBAT3 : 61 VBAT3 : 62 N.C. : 63 N.C. : 64 N.C.
MB3891 3 ■ ■ ■ ■ PIN DESCRIPTION (Continued) Pin No. Symbol I/O Descriptions 1, 2 N.C. Non connection. 3, 4 OUT3 O LDO3 output pin. 5G N D 3 LDO3 ground pin. 6, 7 OUT2 O LDO2 output pin. 8, 9, 10, 11 VBAT1 Battery voltage input pin for LDO1 and LDO2.
MB3891 4 (Continued) Pin No. Symbol I/O Descriptions 42, 43 VBAT4 Supply voltage for LDO4. 44 CONT4 I OUT4 output voltage selection (“L”=2.8 V,“H”=2.5 V). 45 SW1-OUTPUT O Output of general purpose switch number 1 (Drain). 46 SW1-INPUT I Input of general purpose switch number 1 (Source).
MB3891 5 ■ ■ ■ ■ BLOCK DIA GRAM 14 16 53 54 55 44 22 33 20 8 9 10 11 12 13 17 18 19 15 + − 6 7 46 45 52 51 48 60 61 42 43 62 3 5 4 47 40 41 39 21 34 35 36 37 38 27 28 26 CONT1 CONT6 CONT2 SW.
MB3891 6 ■ ■ ■ ■ ABSOLUTE MAXIMUM RA TINGS * : The packages are mounted on the dual-sided epo xy board(10 cm × 10 cm) W ARNING: Semiconductor de vices can be per manently damaged by application of stress (v oltage, current, temperature , etc.
MB3891 7 ■ ■ ■ ■ ELECTRICAL CHARA CTERISTICS (Ta = + 25 ° C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V) * : Standard design v alue (Continued) P arameter Symbol Pin No.
MB3891 8 (Ta = + 25 ° C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V) (Continued) Pa r a m e t e r Sy m b o l Pin No. Conditions Va l u e Unit Min. T yp. Max. LDO1 (OUT1) Output voltage V O 12, 13 − 50 µ A > OUT1 > − 120 mA 2.000 2.100 2.200 V Line regulation Line 12, 13 3.
MB3891 9 (Ta = + 25 ° C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V) (Continued) P arameter Symbol Pin No. Conditions Va l u e Unit Min. T yp. Max. LDO3 (OUT3) Output voltage V O 3, 4 − 50 µ A > OUT3 > − 100 mA 2.700 2.800 2.900 V Line regulation Line 3, 4 3.
MB3891 10 (Ta = + 25 ° C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V) (Continued) P arameter Symbol Pin No. Conditions Va l u e Unit Min. T yp. Max. LDO6 (V-BACKUP) Output voltage V O 21 − 10 µ A > V-BA CKUP > − 250 µ A 2.000 2.100 2.200 V Line regulation Line 21 3.
MB3891 11 (Ta = + 25 ° C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V) (Continued) P arameter Symbol Pin No. Conditions Va l u e Unit Min. T yp. Max. VSIMOUT chargepump Ripple rejection ∆ VCC-VSIM/ ∆ VSIMOUT R.R 29 f = 217 Hz 30 dB Output current I O 29 3.
MB3891 12 (Continued) (Ta = + 25 ° C, VBAT1 to VBAT4 = VCC-VSIM = 3.6 V) P arameter Symbol Pin No. Conditions Va l u e Unit Min. T yp. Max. SIM interface 5 V (SIMPROG = H) Output voltage V OH 36 RST (max.) = − 20 µ A VSIMOUT − 0.7 VSIMO UT V V OL 36 RST (max.
MB3891 13 ■ ■ ■ ■ TYPICAL CHARA CTERISTICS (Continued) 400 350 300 250 200 150 100 50 0 012 345 Ta = + 25 ° C CONT1 = “L” CONT2 = “H” CONT3 = “H” CONT4 = OPEN CONT5 = OPEN CONT6 =.
MB3891 14 0 − 20 − 40 − 60 − 80 − 100 10 100 1 k 10 k 100 k 1 M Ta = + 25 ° C VBAT = 3.6 V OUT1 = 1 µ F OUT1 = 18 Ω CONT1 = “L” CONT6 = OPEN 0 − 20 − 40 − 60 − 80 − 100 10 100 1 k 10 k 100 k 1 M Ta = + 25 ° C VBAT = 3.6 V OUT1 = 1 µ F CONT1 = “L” CONT6 = OPEN 0.
MB3891 15 (Continued) 4 3 2 1 0 2 1 0 0 50 100 150 200 250 300 350 400 450 500 Ta = + 25 ° C OUT1 = No load CONT1 = “L” CONT6 = OPEN VBAT OUT1 4 2 0 2 1 0 0.
MB3891 16 (Continued) 2.0 1.5 1.0 0.5 0.0 2 1 0 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 OUT1 = − 120 mA 0 A V C OUT1 Ta = + 25 ° C VBAT = 3.6 V CONT1 = “L” CONT6 = OPEN VBAT = 3.6 V VREF = 1.225 V LDO1 OUT1 1 µ F 120 mA 4 V 0 V V C 3.0 2.5 2.
MB3891 17 (Continued) 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 01234 56 7 Ta = + 25 ° C VFIL = 0.1 µ F 1.24 1.23 1.22 1.21 1.20 1.19 − 40 − 20 0 20 40 60 80 100 VBAT = 3.6 V Ta = + 25 ° C VBAT = 3.6 V VSIM-ON = “H” SIMPROG = “H” VSIMOUT = 510 Ω VSIMOUT = No load 100000 10000 1000 100 10 1 012 345 Ta = + 25 ° C VBAT = 3.
MB3891 18 (Continued) 3.00 2.99 2.98 2.97 2.96 2.95 2.94 2.93 2.92 2.91 2.90 0 − 5 − 10 − 15 − 20 VCC-VISM = 5.5 V VCC-VISM = 3.1 V VCC-VISM = 3.6 V Ta = + 25 ° C VSIM-ON = “H” SIMPROG = “L” 5.00 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 0 − 5 − 10 − 15 − 20 VCC-VISM = 5.
MB3891 19 (Continued) 100 90 80 70 60 50 40 30 20 10 0 3.0 3.5 4.0 4.5 5.0 5.5 Ta = + 25 ° C VSIM-ON = “H” SIMPROG = “L” ILOAD = − 10 mA ILOAD = − 1 mA 100 90 80 70 60 50 40 30 20 10 0 3.
MB3891 20 (Continued) SIMPROG VSIMOUT Ta = + 25 ° C VBAT = VCC-VSIM = 3.6 V VSIMOUT = 510 Ω VSIM-ON = “H” 0.0 0.5 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 1.0 10 5 0 5 4 3 2 1 0 SIMPROG VSIMOUT Ta = + 25 ° C VBAT = VCC-SIM = 3.6 V VSIMOUT = 510 Ω VSIM-ON = “H” 0.
MB3891 21 (Continued) 5 4 3 2 1 0 0.0 0.5 1.0 1.5 2.0 2.5 SIMPROG = "H" SIMPROG = "L" Ta = +25 ° C VBAT = VCC-VSIM = 3.6 V VSIM-ON = "H" CONT1 = "L" CONT6 = OPEN 2.5 2.0 1.5 1.0 0.5 0.0 012 345 Ta = +25 ° C VBAT = VCC-VSIM = 3.
MB3891 22 (Continued) 3.10 3.05 3.00 2.95 2.90 2.85 2.80 − 40 − 20 0 20 40 60 80 100 VBAT = VCC-VSIM = 3.6 V VSIM-ON = “H” SIMPROG = “L” 5.
MB3891 23 ■ ■ ■ ■ FUNCTIONAL DESCRIPTION (1) MAIN UVLO/B A CKUP UVLO T ransient po w er-on surge states or sudden drops in supply v oltage (VBA T2) can cause an IC to operate abnor- mally , leading to destruction or damage to system elements.
MB3891 24 (8) LDO5 The LDO5 circuits uses the ref erence voltage supply and generates an output v oltage (2.8 V typ .) at the OUT5 ter minal (pin 57) when the OUT1 terminal (pin 12,13) is in output state and an “H” le v el signal is input at the CONT5 ter minal (pin 57).
MB3891 25 ■ ■ ■ ■ OPERA TION TIMING CHART VBAT1 to VBAT4, VCC-VSIM CONT1 CONT6 CONT5 CONT2 CONT3 SW1-ON VSIM-ON SIMPROG REF-OUT OUT6 OUT1 XPOWERGOOD OUT5 OUT2 OUT3 (OUT4) SW1-OUTPUT VSIMOUT SW2-OUTPUT (SW3-OUTPUT) SW2-ON (SW3-ON) delay 2.
MB3891 26 ■ ■ ■ ■ APPLICA TION EXAMPLE C1 1 µ F C12 1 µ F C11 1 µ F C2 0.033 µ F C3 1 µ F C4 1 µ F C5 1 µ F C6 1 µ F C7 1 µ F C8 0.1 µ F C10 0.
MB3891 27 ■ ■ ■ ■ USA GE PRECA UTIONS • Printed cir cuit boar d gr ound lines should be set up with consideration for common impedance. • T ake appropriate static electricity measures. • Containers f or semiconductor materials should ha v e anti-static protection or be made of conductive material.
MB3891 ■ ■ ■ ■ P A CKA G E DIMENSION 64-pin plastic LQFP (FPT-64P-M03) Note : Pins width and pins thickness include plating thickness. Dimensions in mm (inches) . C 1998 FUJITSU LIMITED F64009S-3C-6 "A" 33 32 17 16 1 64 49 48 INDEX 12.
MB3891 FUJITSU LIMITED All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Fujitsu MB3891 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Fujitsu MB3891 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Fujitsu MB3891 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Fujitsu MB3891 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Fujitsu MB3891, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Fujitsu MB3891.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Fujitsu MB3891. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Fujitsu MB3891 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.