Manuale d’uso / di manutenzione del prodotto FHG 2L del fabbricante Foster
Vai alla pagina of 20
Display Case FHG 2L & FHG 3L.
1 Foster Refrigerator Environmental Manag ement Policy Product Support and Installation Contra ctors Foster Refrigerator recog nises that its activities, products and services can have an adverse impa ct upon the environment.
2 Introduction The display case are manufactured in two formats FHG 2L, 2 doors, and the F HG 3L, three doors. There are also Multiplex options that are a combi nation of two FHG 2L cases to make a FHG 4L or a combinatio n of the FHG 2L and FHG 3L to make a FHG 5L.
3 Temperature controller It is strongly advised that b efore adjusting any Serv ice Parameters a thorough understanding o f the following instructions should be obtained. Carel PB00F0HB10 Controller Display and Symbols. NOTE: When the buttons are presse d a brief audible signal is emitted; this signal can not be disabled.
4 9. Compressor: Illuminated when the co mpressor is running. Flashes when the activation of the compre ssor is delayed by safety times. 10. FAN: Illuminated when the fan starts. Flashes when the activation of the fan is prevented due to extern al disabling or proced ures in pr ogress.
5 3. Confirm by pressing . 4. The display shows the code of the first modifiable type “C” paramete r. Modifying the parameters. After having accessed the parameters, either type “C” or typ e “F”, proceed as follows.
6 Classification of Parameters The parameters, as well as being divided into type, are al so grouped into logical categories identified by the initial letters or symbols of such parameters. The following t able lists the catego rise and the corresponding letters.
7 35 c9 Enable autostart with PD operation flag 0 0 0 36 c10 Select Pd by time or pressure flag 0 0 0 37 c11 Delayed compressor delay sec 4 4 4 38 d0 Type of defrost flag 0 1 1 39 dI Interval between defrosts hours 8 6 6 40 dt1 End defrost temperature, evaporator.
8 Parameter Definitions /2 Measurement stability. Defines the coefficient used to stabili se the temperature reading. /3 Probe display rate Sets the rate at which the temperature display is updated.
9 r3 Operating mode The controller can work as a thermostat an d defrost cont roller (r3 = 0), or as a simple thermo stat in direct operation (r3 = 1), or as a simple thermostat in Reverse- cycle op eration (r3 = 2). Default setting: r3 = 0. r4 Automatic variation of the set point in night time oper ation.
10 c11 Delayed compressor delay Not used by Foster Default: c11 = 4 d0 Type of Defrost Sets the type of defrost required. Default: d0 = 0. Foster setting d0 = 1. Hot gas defrost termi nated by evaporator probe or in the event of probe failure by time (see dP1).
11 d/1 Display defrost probe. Displays the value measured by the defrost probe. Once d/1 has been selected pre ss the button to display the temperature measured by the defrost probe. d/2 Display defrost prob e 2 reading. Not used by Foster. dC Base time for defrost.
12 Default: A6 = 0. A7 External alarm detection delay . Not used by foster Default: A7 = 0. A8 Enables alarm ‘Ed1’ and ‘Ed2’. Not used by Foster. Default: A8 = 0 = alarms ‘Ed1’ and ‘Ed2’ disabled. Ado Door switch light management mode.
13 Default: H3 = 0. H4 Disable buzzer. H4 = 0 buzzer enabled. H4 = 1 buzzer disabled. Default: H4 = 0. H5 Function of relay 5 . Not used by Foster. Default: H5 = 3. H6 Lock out Butto ns. Not used by Foster. Default: H6 = 0. H7 Select Keypad. Used to select the type of keypad on the controller.
14 MCB Siemens 5SY6316 –8 TP 16 Amp 3 Pole 16240209 X X Wiring diagrams The drawings numbers for the display cases are a s follows: FHG2L - 2 door unit single pha se 00-233867-02 FHG2L - 2 door unit.
15.
FHG2L - 2 door unit single pha se 00-233867-02.
FHG2L - 2 door unit three phase 00-233868-02.
1 FHG3L - 3 door unit three phase 00-233869-02.
Foster European Operations France Foster Refrigerator France SA Tel: (33) 01 34 30 22 22. Fax: (33) 01 30 37 68 74. Email: commercial@fosterfrance.com Germany Foster Refrigerator Gmbh, Tel: (49) 2333 839375. Fax (49) 2333 8393 77. Email: info@foster-gmbh.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Foster FHG 2L è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Foster FHG 2L - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Foster FHG 2L imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Foster FHG 2L ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Foster FHG 2L, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Foster FHG 2L.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Foster FHG 2L. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Foster FHG 2L insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.