For more information, visit www .fmiproducts.com MODELS P324E, VP324E, P325E(B) AND VP325E(B) NA TURAL GAS B-VENT DECORA TIVE GAS FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL FOR YOUR SAF.
www .fmiproducts.com 108794-01G 2 W ARNING: Improper installation, adjustment, al - teration, service or maintenance can cause injury or property damage. Refer to this manual for correct in - stallation and operational procedures.
www .fmiproducts.com 108794-01G 3 SAFETY W ARNING: This product con - tains and/or generates chemicals knownto theStateof California tocausecanceror birthdefects orotherreproductiveharm.
www .fmiproducts.com 108794-01G 4 1 1. K e ep th e a r e a ar o u n d yo u r f i re p l ac e clear of combustib le materials, gasoline and other ammable vapor and liquids. Do not run fireplace where these are used or stored. Do not place items such as clothing or decorations on or around replace.
www .fmiproducts.com 108794-01G 5 W ARNING: Installation of this appliance should be done by a qualied service person well trained in the installation of such appliances.
www .fmiproducts.com 108794-01G 6 PRODUCT SPECIFICA TIONS Figure 2 - Appliance Dimensions 6 7 / 8 " 2 1 / 4 " 7" 7" Alternate Gas Supply Inlet 13 1 / 4 " 32 1 / 4 " * 27 .
www .fmiproducts.com 108794-01G 7 PRE-INST ALLA TION PREP ARA TION Figure 3 - Minimum Clearances (T op V iew) 0" 0" Clearance Nailing Flange Front Face Left Side Surround Back Drywall 2 x 4 .
www .fmiproducts.com 108794-01G 8 PRE-INST ALLA TION PREP ARA TION Continued FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall covering is used to line enclosure, then all measurements must be from surface of covering.
www .fmiproducts.com 108794-01G 9 This appliance may be vented through a manufactured chimney system or a masonry chimney using a B-vent adapter or a chim - ney l iner syst em if all are listed, insp ected and approved by local codes and/or building authorities.
www .fmiproducts.com 108794-01G 10 VENTING INST ALLA TION Continued It is not recommended that this appliance be common vented with an existing gas burning appliance.
www .fmiproducts.com 108794-01G 11 FIREPLACE INST ALLA TION Figure 12 - Removing Front Refractory Access Panel (P325E/VP325E Model Shown) Figure 13 - Installing the WRC Remote Receiver Fireplace Recep.
www .fmiproducts.com 108794-01G 12 GAS LINE HOOK-UP W ARNING: Gas line hookup should be done by your gas suppli - eroraqualiedserviceperson. W ARNING: Before you pro- cee d, make sur e your gas sup ply is OFF .
www .fmiproducts.com 108794-01G 13 3" Min. (7.6 cm) Side Wall Of Appliance Incoming 1/2" Gas Line Permitted by Local Codes Sediment T rap (Not Supplied) Figure 17- Sediment Trap FIREPLACE IN.
www .fmiproducts.com 108794-01G 14 0.5" 0.5" Figure 22 - Pan and Ember Material Clearances Grate Burner Pan Pan and Ember Material EMBER AND P AN MA TERIAL PLACEMENT 1. Open bag(s) of vermiculite and ll entire burner pan until burner tube is completely covered (see Figure 20).
www .fmiproducts.com 108794-01G 15 Figure 24 - Installing Logs 3 and 4 Log 4 Log 3 FIREPLACE INST ALLA TION Continued LOGPLACEMENTFORP325E(B)/ VP325E(B)MODELS 1. Place large back log (log 1) onto grate making sure notches rest over grate (see Figure 25).
www .fmiproducts.com 108794-01G 16 FIREPLACE INST ALLA TION Continued COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left sid e of repl ace onl y . The vent can be ins tall ed through any outside wall a minimum of 3 feet belo w repla ce termi nati on cap.
www .fmiproducts.com 108794-01G 17 FIREPLACE INST ALLA TION Continued Figure 31 - Installing Optional Glass Door Spring Clip Insert Pin Into Spring Clip Insert Bottom Pivot Pin Into Pivot Plate and Swing Door Into V ertical Position Pivot Plate Slide T op Pin Into Door T rack 4.
www .fmiproducts.com 108794-01G 18 OPERA TION 1. STOP! Read safety information, column 1. 2. Turn wall switch to the OFF position. 3. Turn off all electric power to appliance. 4. Fully open glass doors if installed. 5. Remove front refractory brick access panel.
www .fmiproducts.com 108794-01G 19 TO TURN OFF GAS TO APPLIANCE 1. Turn off wall switch. 2. Turn of f all electric power to appliance if service is to be performed. 3. Fully open glass doors if installed. 4. Remove front hearth brick and control access panel.
www .fmiproducts.com 108794-01G 20 CLEANING AND MAINTENANCE W ARNING: Installation and repair should be done by a quali - ed service person. The appli - ance should be insp ecte d before each use and at least annually by a qualied service person.
www .fmiproducts.com 108794-01G 21 WIRING DIAGRAM STEP DOWN TRANSFORMER VENT SAFETY SHUTOFF SWITCH EV2 SUPPL Y INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC 120V AC 120V AC INCOMING OR BREAKER) (FUSE BOX OFF ON (SUPPLIED) WALL SWITCH GREEN BLACK WHITE 120v , 60Hz, 0.
www .fmiproducts.com 108794-01G 22 TROUBLESHOO TING Note: Before troubleshooting the system, make sure the gas shutoff valve is ON. The two most common causes of a malfunctioning gas appliance are: 1.
www .fmiproducts.com 108794-01G 23 TROUBLESHOO TING Continued W ARNING:Ifyousmellgas • Shutoffgassupply . • Donottrytolightanyappliance. • Do not touch any electrical switch; do not use any phone in your building.
www .fmiproducts.com 108794-01G 24 TROUBLESHOO TING Continued OBSERVED PROBLEM Dark residue on logs or inside of replace POSSIBLE CAUSE 1. Improper log placement 2. A ir hol es at bu rn er i nl et blocked 3 . Burner flame holes blocked 4. Impr ope r vent ing or exc es - sive blockage 5 .
www .fmiproducts.com 108794-01G 25 ACCESSORIES Purc hase thes e acc esso ries from your loca l deal er . If they can not supply thes e acc esso ries call FMI PRODUC TS, LLC at 1-866- 328- 4537 for inform ation . Y ou can also wri te to the addr ess listed on the back page of this manual.
www .fmiproducts.com 108794-01G 26 P ARTS MODELS P324E AND VP324E 33 43 41 15 19 24 14 30 26 29 3 14 12 13 23 35 16 31 32 5 5 32 38 39 40 4 34 21 20 22 44 44 37 42 1 1 36 28 25 9 2 7 17 1 1 6 27 10 1 .
www .fmiproducts.com 108794-01G 27 P ARTS MODELS P324E AND VP324E This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY NO. P ART NO. DESCRIPTION QTY .
www .fmiproducts.com 108794-01G 28 P ARTS MODELSP325E(B) ANDVP325E(B) 33 43 41 15 19 24 14 30 26 29 17 14 12 13 24-3 18 18 24-9 NG LP 24-8 24-8 24-4 24-9 24-12 24-10 24-1 1 24-6 24-2 24-5 .
www .fmiproducts.com 108794-01G 29 KEY NO. P ART NO. DESCRIPTION QTY . 1 108769-03 Extension Deector 2 2 1 1201 Nut, #8-32 Hex Zinc. 2 3 1 1 109 Screw, #8-32 x 1/2" PPH Zinc. 2 4 108425-01 Air Rod Retainer 1 5 108423-01 Panel Closure 2 6 1 1 186 Screw, #8-32 x 1" PPH Zinc.
www .fmiproducts.com 108794-01G 30 P ARTS LOG ASSEMBL Y KEY NO. P ART NO. DESCRIPTION QTY . - 109109-01 Log Set 1 105958-05 Front Log 1 2 105960-05 Rear Log 1 3 901 100-02 T op Right Log 1 4 901 102-02 T op Left Log 1 1 2 3 4 5 P324E and VP324E Models 1 4 2 3 P325E(B) and VP325E(B) Models KEY NO.
www .fmiproducts.com 108794-01G 31 _____________________________________________________ ______________________________________________________ ______________________________________________________ _.
108794-01 Rev . G 09/09 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES NewProducts Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il FMI P324E è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del FMI P324E - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso FMI P324E imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul FMI P324E ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il FMI P324E, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del FMI P324E.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il FMI P324E. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo FMI P324E insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.